Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Access Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

RCT: Module 2.10, Access Control and Work Area Setup, Course 8776

This course presents information on radiological work permits (RWPs), various types of postings used in radiological areas, radiological area setups, access controls, and releases of material from radiological areas. All of these are fundamental duties of RCTs. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Controlling accesses to a branch prediction unit for sequences of fetch groups

An electronic device is described that handles control transfer instructions (CTIs) when executing instructions in program code. The electronic device has a processor that includes a branch prediction functional block and a sequential fetch logic functional block. The sequential fetch logic functional block determines, based on a record associated with a CTI, that a specified number of fetch groups of instructions that were previously determined to include no CTIs are to be fetched for execution in sequence following the CTI. When each of the specified number of fetch groups is fetched and prepared for execution, the sequential fetch logic prevents corresponding accesses of the branch prediction functional block for acquiring branch prediction information for instructions in that fetch group.

Yalavarti, Adithya↗

High-Level Considerations for Access and Access Controls by Design

Nuclear power plants must be, by design and construction, robust structures and difficult to penetrate. Limiting access with difficult-to-penetrate physical barriers is going to be key for staffing reduction. Ideally, for security, the reactors would be sited underground, beneath a massive solid block, too thick to be penetrated by tools or explosives with all communications and power transfer lines also underground and fortified. Having the minimal possible number of access points and methods to completely block access from these points if a threat is detected will greatly help us justify staffing reduction.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Controlling accesses to a branch prediction unit for sequences of fetch groups

An electronic device handles accesses of a branch prediction functional block when executing instructions in program code. The electronic device includes a processor having the branch prediction functional block that provides branch prediction information for control transfer instructions (CTIs) in the program code and a minimum predictor use (MPU) functional block. The MPU functional block determines, based on a record associated with a given fetch group of instructions, that a specified number of subsequent fetch groups of instructions that were previously determined to include no CTIs or conditional CTIs that were not taken are to be fetched for execution in sequence following the given fetch group. The MPU functional block then, when each of the specified number of the subsequent fetch groups is fetched and prepared for execution, prevents corresponding accesses of the branch prediction functional block for acquiring branch prediction information for instructions in that subsequent fetch group.

Agrawal, Varun↗

Advance Reservation Access Control Using Software-Defined Networking and Tokens

Advance reservation systems allow users to reserve dedicated bandwidth connection resources from an advanced high-speed network. A common use case for such systems is data transfers in distributed science environments in which a user wants exclusive access to the reservation. However, current advance network reservation methods cannot ensure exclusive access of a network reservation to the specific flow for which the user made the reservation. We present here a novel network architecture that addresses this limitation and ensures that a reservation is used only by the intended flow. We achieve this by leveraging software-defined networking (SDN) and token-based authorization. We use SDN to orchestrate and automate the reservation of networking resources, end-to-end and across multiple administrativedomains, and tokens to create a strong binding between the user or application that requested the reservation and the flows provisioned by SDN.

Kettimuthu, R.↗

High-Level Considerations for Access and Access Controls by Design

Nuclear power plants must be, by design and construction, robust structures and difficult to penetrate. Ideally, for security, the reactors would be sited underground, beneath a massive solid block, too thick to be penetrated by tools or explosives with all communications and power transfer lines also underground and fortified. Limiting access with difficult-to-penetrate physical barriers is going to be key for determining response and staffing requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Level Considerations for Access and Access Controls by Design

The design and construction of a nuclear power plant must include robust structures and a security boundary that is difficult to penetrate. For security considerations, the reactors would ideally be sited underground, beneath a massive solid block, which would be too thick to be penetrated by tools or explosives. Additionally, all communications and power transfer lines would also be located underground and would be fortified against any possible design basis threats. Limiting access with difficult-to-penetrate physical barriers is a key aspect for determining response and staffing requirements. Considerations considered in a graded approach to physical protection are described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operation Request Gatekeeper: A software system for remote access control of diagnostic instruments in fusion experiments

Tokamak diagnostic settings are repeatedly modified to meet the changing needs of each experiment. Enabling the remote diagnostic control has significant challenges due to security and efficiency requirements. The Operation Request Gatekeeper (ORG) is a software system that addresses the challenges of remotely but securely submitting modification requests. The ORG provides a framework for screening all the requests before they enter the secure machine zone and are executed by performing user authentication and authorization, grammar validation, and validity checks. A prototype ORG was developed for the ITER CODAC that satisfies their initial requirements for remote request submission and has been tested with remote control of the KSTAR Plasma Control System. This paper describes the software design principles and implementation of ORG as well as worldwide test results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EPA GHG Certification of Medium- and Heavy-Duty Vehicles: Development of Road Grade Profiles Representative of US Controlled Access Highways

This report includes a detailed comparison of the TomTom national road grade database relative to a local road grade dataset generated by Southwest Research Institute and a national elevation dataset publically available from the U.S. Geological Survey. This analysis concluded that the TomTom national road grade database was a suitable source of road grade data for purposes of this study.

54 ENVIRONMENTAL SCIENCES↗

Apparatus, method and system to control accessibility of platform resources based on an integrity level

Techniques and mechanism to selectively provide resource access to a functional domain of a platform. In an embodiment, the platform includes both a report domain to monitor the functional domain and a policy domain to identify, based on such monitoring, a transition of the functional domain from a first integrity level to a second integrity level. In response to a change in integrity level, the policy domain may configure the enforcement domain to enforce against the functional domain one or more resource accessibility rules corresponding to the second integrity level. In another embodiment, the policy domain automatically initiates operations in aid of transitioning the platform from the second integrity level to a higher integrity level.

Jenkins, Chris↗