At least 37 records · Page 2

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Ablators - From Apollo to Future Missions to Moon, Mars and Beyond

Apollo was designed to carry astronauts safely back from the Moon at return speeds exceeding 11 km/s and requireddevelopment of a new ablative thermal protection system (TPS) to protect the capsule from entry heating. Mercuryand Gemini, that preceded Apollo, were focused on Earth orbiting system demonstration and lessons learned fromthem were used in Apollo. The ablative material and associated system development for Lunar return conditionsrequired considerable ground and flight testing. Mars Viking Lander missions required a new lighter weight ablatoras entry heating was benign compared to Apollo. Pioneer-Venus and Galileo Probe missions required a new and morecapable ablator than Apollo. After two decades, Mars Pathfinder followed by Mars Exploration Rover missions,smaller than Viking but more demanding, were able to use Viking ablative TPS. At the same time, advances in manufacturing and materials technology led to development of innovative lightweight ablators. These new ablators enabled Stardust and Genesis Sample Return Missions. Around the turn of this century, NASA decided on a scaled-upversion of the Apollo capsule for human exploration of Moon and Mars and the ablative heat shield to protect the CrewExploration Vehicle ended up being the Apollo ablative TPS. The Artemis 1 mission is currently fitted with tiledsystem, different than Orion EFT-1 but with the Apollo ablative material as a result of lessons learned. NASA iscurrently planning on sample return missions from Mars, and this will require robust ablative TPS that can providehigher reliability than any other past mission. There are still unexplored high scientific value destinations in the solarsystem. In situ exploration of Uranus, Neptune, Saturn and sample return missions with return speed much higher thanStardust will require ablators capable of withstanding extreme entry that are also efficient. New ablative TPS havebeen developed in anticipation of these future missions. This paper is intended to tell the story of these ablators,illustrated through examples. We see the use of flight proven ablators was sometimes a risky proposition and newablators perceived to be higher risk have proved otherwise. The history of ablators illustrates the challenges eachmission had to address, either through the use of flight proven or new ablative TPS, to be successful.

Venkatapathy, Ethiraj↗

Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K‐Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some μg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example, variable vacuum pressure), and c) the ablation is made with hundreds of successive laser pulses. In this work, we aim to understand the effects that occur on LIBS spectra when a homogeneous rock or a mineral is ablated under high vacuum. Understanding these effects is important to define best practices for LIBS measurements and may lead to improved measurement (or possibly prediction) of the ablated volume. We will describe our laboratory approach and first results, and discuss its utility for situ absolute geochronology campaigns.

Devismes, D.↗

Ablation article and method

An ablation article, such as a conical heat shield, having an ablating surface is provided with at least one discrete area of at least one seed material, such as aluminum. When subjected to ablation conditions, the seed material is ablated. Radiation emanating from the ablated seed material is detected to analyze ablation effects without disturbing the ablation surface. By providing different seed materials having different radiation characteristics, the ablating effects on various areas of the ablating surface can be analyzed under any prevailing ablation conditions. The ablating article can be provided with means for detecting the radiation characteristics of the ablated seed material to provide a self-contained analysis unit.

Erickson, W. D.↗

Improving indirect-drive ablator performance through pulse shaping and material selection in double shell implosions

The double shell path to inertially confined volumetric thermonuclear burn relies on efficient kinetic energy transfer from an outer ablator shell to an inner shell containing DT fuel at implosion velocities near 250 km/s. In order to experimentally realize adequate compression, target imperfections and assembly features must be tightly controlled. Pulse shape and ablator material are critical design choices that impact all aspects of the implosion. In this article, we evaluate three designs: an Al ablator with single-shock radiation drive, a CH ablator with single-shock drive, and a CH ablator with reduced-adiabat 2-shock drive. All designs use the same W inner (pusher) shell overcoated with a glow discharge polymer tamper and filled with liquid-density DT. One-dimensional HYDRA simulations revealed that the plastic ablator design required the use of the 2-shock drive to match the performance of the Al design. Two-dimensional simulations resolving broadband surface roughness up to modes of several hundred placed only on the ablator showed plastic to greatly outperform Al. The plastic ablator designs did exhibit higher levels of inner shell instability growth when surface roughness was only placed at the pusher/tamper interface, which was mitigated with higher foam cushion densities. A unique and additional benefit of a plastic ablator is also discussed, where heating of the ablator by Au M-band radiation is predicted to rapidly expand the hemi-shell surfaces, closing the equatorial joint gap ahead of the first shock. Taken together, the properties of the plastic ablator for indirect-drive double shell implosions appear promising in removing several long-standing fabrication challenges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of Capsule Reentry Vehicle Heat Shield Ablation Using Naphthalene PLIF

The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield and improved understanding of the ablation process would be beneficial for design purposes. Given that ablation is a multi-physics process involving heat and mass transfer, codes aiming to predict heat shield ablation are in need of experimental data pertaining to the turbulent transport of ablation products for validation. At The University of Texas at Austin, a technique is being developed that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to visualize the transport of ablation products in a supersonic flow. Since ablation at reentry temperatures can be difficult to recreate in a laboratory setting it is desirable to create a limited physics problem and simulate the ablation process at relatively low temperature conditions using naphthalene. A scaled Orion MPCV model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel at various angles of attack in the current work. PLIF imaging reveals the distribution of the ablation products as they are transported into the heat-shield boundary layer and over the capsule shoulders into the separated shear layer and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. High concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure were observed using the naphthalene PLIF technique. The capsule shear layer was also shown to generally appear to be more turbulent at lower angles of attack. Furthermore, the PLIF signal increased steadily over the course of a run indicating that during a wind tunnel run the model heated up and the rate of naphthalene ablation increased. The shear layer showed increasing signs of turbulence over the course of a wind tunnel run as well, likely because of the combination of increased surface roughness and surface blowing rate. PLIF imaging also detected regions with a relatively low concentration of naphthalene in the capsule backshell recirculation region that are most likely the result of cross-flow-induced vortices on the capsule afterbody.

Combs, Christopher S.↗

Carbon ablator areal density at fusion burn: Observations and trends at the National Ignition Facility

For inertial confinement fusion experiments, the pusher is composed of a high-density deuterium tritium cyrogenic fuel layer and an ablator, often made of carbon. In an ideal, no-mix implosion, increasing the areal density of the pusher transfers more pressure to the hot spot and increases the hot spot confinement time. There has been a lack of knowledge about the final compressed state of the ablator for implosions at the National Ignition Facility. 14 MeV fusion neutrons inelastically scattering on the remaining carbon ablator excites a nuclear metastable state that emits a prompt 4.4 MeV gamma ray. The gamma reaction history diagnostic data, when reduced by a new data analysis technique, can isolate and measure the carbon gamma rays, which are proportional to the areal density of the ablator during fusion burn. The trends over many National Ignition Facility campaigns show that the ablator areal density is weakly sensitive to the maximum shell velocity, the cold fuel radius, the ablator mass remaining, or the laser picket intensity. Controlled parameter scans reveal that, for specific campaigns, ablator compression has a strong dependence on laser coast time, high Z dopants, and the laser drive foot duration. Using a model of the compressed ablator density profile reveals that the greatest variation of the ablator areal density comes from its thickness, with highly compressed, thin layers having high areal density values. The compression and thickness of the ablator are other metrics that designers should understand to differentiate the types of capsule degradation and maximize the inertial confinement fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

The Influence of Ablation on Radiative Heating for Earth Entry

Using the coupled ablation and radiation capability recently included in the LAURA flowfield solver, this paper investigates the influence of ablation on the shock-layer radiative heating for Earth entry. The extension of the HARA radiation model, which provides the radiation predictions in LAURA, to treat a gas consisting of the elements C, H, O, and N is discussed. It is shown that the absorption coefficient of air is increased with the introduction of the C and H elements. A simplified shock layer model is studied to show the impact of temperature, as well as the abundance of C and H, on the net absorption or emission from an ablation contaminated boundary layer. It is found that the ablation species reduce the radiative flux in the vacuum ultraviolet, through increased absorption, for all temperatures. However, in the infrared region of the spectrum, the ablation species increase the radiative flux, through strong emission, for temperatures above 3,000 K. Thus, depending on the temperature and abundance of ablation species, the contaminated boundary layer may either provide a net increase or decrease in the radiative flux reaching the wall. To assess the validity of the coupled ablation and radiation LAURA analysis, a previously analyzed Mars-return case (15.24 km/s), which contains significant ablation and radiation coupling, is studied. Exceptional agreement with previous viscous shock-layer results is obtained. A 40% decrease in the radiative flux is predicted for ablation rates equal to 20% of the free-stream mass flux. The Apollo 4 peak-heating case (10.24 km/s) is also studied. For ablation rates up to 3.4% of the free-stream mass flux, the radiative heating is reduced by up to 19%, while the convective heating is reduced by up to 87%. Good agreement with the Apollo 4 radiometer data is obtained by considering absorption in the radiometer cavity. For both the Mars return and the Apollo 4 cases, coupled radiation alone is found to reduce the radiative heating by 30 60% and the convective heating by less than 5%.

Johnston, Christopher O.↗