Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AUDITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm{sup 3} prototype phantom that had two slots capable of holding Al{sub 2}O{sub 3}:C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all {sup 192}Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian {sup 192}Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k{sub L}= (−9.43 × 10{sup −5}× dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using {sup 60}Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian {sup 192}Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a formal RPC audit program. Trial audits of four Nucletron sources and four Varian sources revealed an average RPC-to-institution dose ratio of 1.000 (standard deviation = 0.011).Conclusions: The authors have created an OSLD-based {sup 192}Ir HDR brachytherapy source remote audit tool which offers sufficient dose measurement accuracy to allow the RPC to establish a remote audit program with a ±5% acceptance criterion. The feasibility of the system has been demonstrated with eight trial audits to date.

61 RADIATION PROTECTION AND DOSIMETRY↗

Safety Auditing and Assessments

Safety professionals typically do not engage in audits and independent assessments with the vigor as do our quality brethren. Taking advantage of industry and government experience conducting value added Independent Assessments or Audits benefits a safety program. Most other organizations simply call this process "internal audits." Sources of audit training are presented and compared. A relation of logic between audit techniques and mishap investigation is discussed. An example of an audit process is offered. Shortcomings and pitfalls of auditing are covered.

Goodin, James Ronald (Ronnie)↗

National Energy Audit Tool for Multifamily Buildings — Development Plan

The U.S. Department of Energy's (DOE's) Weatherization Assistance Program (WAP) enables low-income families to reduce their energy costs by providing funds to make their homes more energy efficient. In addition, the program funds Weatherization Training and Technical Assistance (T and TA) activities to support a range of program operations. These activities include measuring and documenting performance, monitoring programs, promoting advanced techniques and collaborations to further improve program effectiveness, and training, including developing tools and information resources. The T and TA plan outlines the tasks, activities, and milestones to support the weatherization network with the program implementation ramp up efforts. Weatherization of multifamily buildings has been recognized as an effective way to ramp up weatherization efforts. To support this effort, the 2009 National Weatherization T and TA plan includes the task of expanding the functionality of the Weatherization Assistant, a DOE-sponsored family of energy audit computer programs, to perform audits for large and small multifamily buildings This report describes the planning effort for a new multifamily energy audit tool for DOE's WAP. The functionality of the Weatherization Assistant is being expanded to also perform energy audits of small multifamily and large multifamily buildings. The process covers an assessment of needs that includes input from national experts during two national Web conferences. The assessment of needs is then translated into capability and performance descriptions for the proposed new multifamily energy audit, with some description of what might or should be provided in the new tool. The assessment of needs is combined with our best judgment to lay out a strategy for development of the multifamily tool that proceeds in stages, with features of an initial tool (version 1) and a more capable version 2 handled with currently available resources. Additional development in the future is expected to be needed if more capabilities are to be added. A rough schedule for development of the version 1 tool is presented. The components and capabilities described in this plan will serve as the starting point for development of the proposed new multifamily energy audit tool for WAP.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA Feedback to DLA Land & Maritime Moratorium on Wafer Fab Audits

On September 29, 2017 the Defense Logistics Agency (DLA), Land and Maritime, announced that on September 1, 2017 they had begun a moratorium on the auditing of wafer fabrication facilities (fabs) used in the production of semiconductor die for military (MIL) qualified integrated circuits and discrete semiconductors (transistors and diodes). The announcement said the moratorium would last for six months initially and would apply to all wafer fabs qualified to MIL-PRF-19500 (discretes) and MIL-PRF-38535 (ICs) located, onshore or offshore. The stated rationale behind this action was to give DLA time to evaluate the risk of modifying current surveillance practices across 70+ Federal Stock Classes (FSC) under the jurisdiction of the DLA Qualifying Activity (VQ). The objective was to free up the resources used in these audits so they could be redirected towards audits of other commodities which were under resourced, notably connectors. In the announcement letter, DLA-VQ requested data from the community to assist with decisions on wafer fab re-audit cycle modifications. NASA used available information on current and historical audit schedules to gather such data and analyzed it to provide an in-depth understanding of the impact of locations, part types, in-house or out-of-house fabs on those schedules over time. This presentation provides the results of NASA's data analysis and suggest some changes to auditing practices that could increase efficient use of resources without significant increases in risk.

fab audits↗

Final Draft of RACER Audit

This document describes the approach Waste and Environmental Services - Environmental Data and Analysis plans to take to resolve the issues presented in a recent audit of the WES-EDA Environmental Database relative to the RACER database. A majority of the issues discovered in the audit will be resolved in May 2011 when the WES-EDA Environmental Database, along with other LANL databases, are integrated and moved to a new vendor providing an Environmental Information Management (EIM) system that allows reporting capabilities for all users directly from the database. The EIM system will reside in a publicly accessible LANL cloud-based software system. When this transition occurs, the data quality, completeness, and access will change significantly. In the remainder of this document, this new structure will be referred to as the LANL Cloud System In general, our plan is to address the issues brought up in this audit in three ways: (1) Data quality issues such as units and detection status, which impinge upon data usability, will be resolved as soon possible so that data quality is maintained. (2) Issues requiring data cleanup, such as look up tables, legacy data, locations, codes, and significant data discrepancies, will be addressed as resources permit. (3) Issues associated with data feed problems will be eliminated by the LANL Cloud System, because there will be no data feed. As discussed in the paragraph above, in the future the data will reside in a publicly accessible system. Note that report writers may choose to convert, adapt, or simplify the information they receive officially through our data base, thereby introducing data discrepancies between the data base and the public report. It is not always possible to incorporate and/or correct these errors when they occur. Issues in the audit will be discussed in the order in which they are presented in the audit report. Clarifications will also be noted as the audit report was a draft document, at the time of this response.

AUDITS↗

Demonstration and Validation of a Virtual Energy Audit Tool for DoD Buildings

Electricity consumption has been in the spotlight as part of the battle for sustainability resulting in legislative measures to try and reduce the amount of energy used. EISA 432 and the Energy Act of 2020 are two examples that require federal facilities to investigate buildings and find saving opportunities through energy audits. EDIFES solves this problem by providing fully virtual audits. Only five inputs are needed (15-minute interval electricity consumption, location, square footage, number of stories, and building end use) to produce complete energy audits. The virtual audit is automated, making them inexpensive and the small number of inputs allows a large number of buildings to be entered quickly. During this project, EDIFES performed energy audits on hundreds of buildings to ensure proper functionality and workflow. Over 250 DoD buildings received energy audits that then had their results posted to an interactive dashboard with portfolio rankings. Several validation methods were employed. All confirmed that EDIFES's methods worked as expected and with a high degree of accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collaboration Leads to State-of-the-Art Energy Auditing Tool: Project Highlights (Fact Sheet)

This fact sheet describes the tablet-based simuwatt Audit tool, which uses NREL's advanced energy modeling framework and building energy audit processes, collaboration tools, in-app media, and private company concept3D's geometric capture software combined with real-time connections to large sets of standardized data to perform building energy audits faster than traditional methods. By integrating the NREL Building Component Library, utility rates, weather information, and energy conservation measures, the tool provides investment-grade audits that cost 75% less than traditional audits and stores the data in a consistent and reusable format.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desktop Audits: Overview, Case Studies, Guidance

The Energy Independence and Security Act (EISA) of 2007 requires that federal agencies audit 25% of their 3.1 billion square feet of covered facilities each year. Several newer, advanced options such as monitoring-based commissioning, fault detection and diagnostics, and energy management systems can help support data collection and analysis to be used for EISA compliance. The Federal Energy Management Program's (FEMP’s) Audit Decision Tree, Audit Definitions, and FEMP Guidance can be used by Agencies to determine the best approaches to evaluate their facilities. FEMP continues to develop additional resources to support agencies in meeting EISA compliance. This presentation gives an overview of desktop audits, including case studies and guidance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ideas That Work! The Midnight Audit

The midnight audit provides valuable insight toward identifying opportunities to reduce energy consumption—insight that can be easily overlooked during the normal (daytime) energy auditing process. The purpose of the midnight audit is to observe after-hour operation with the mindset of seeking ways to further minimize energy consumption during the unoccupied mode and minimize energy waste by reducing unnecessary operation. The midnight audit should be used to verify that equipment is off when it is supposed to be, or operating in set-back mode when applicable. Even a facility that operates 2 shifts per day, 5 days per week experiences fewer annual hours in occupied mode than it does during unoccupied mode. Minimizing energy loads during unoccupied hours can save significant energy, which is why the midnight audit is an Idea That Works.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology to assess “no-touch” building audit software using simulated utility data

Building audits are conducted in many commercial buildings to identify opportunities to reduce energy costs and improve building operation. Because audits require significant effort by building engineers, they are usually only affordable for larger commercial buildings. “No-touch” building audit tools have thus been developed to identify potential savings based on a simplified analysis of building energy consumption patterns via high-level energy data such as monthly utility bills. This paper presents a comprehensive and standardized methodology to evaluate the accuracy of no-touch audit tools in detecting and diagnosing building energy problems and quantifying potential energy savings. The test suite is based on output data from a well-characterized set of building energy models, and the methodology is illustrated by applying it to a representative no-touch building audit tool. Results show that the tool estimates building energy end uses with reasonable accuracy but is less accurate in identifying probably causes of high energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MO-D-213-08: Remote Dosimetric Credentialing for Clinical Trials with the Virtual EPID Standard Phantom Audit (VESPA)

Purpose: Report on implementation of a Virtual EPID Standard Phantom Audit (VESPA) for IMRT to support credentialing of facilities for clinical trials. Data is acquired by local facility staff and transferred electronically. Analysis is performed centrally. Methods: VESPA is based on published methods and a clinically established IMRT QA procedure, here extended to multi-vendor equipment. Facilities, provided with web-based comprehensive instructions and CT datasets, create IMRT treatment plans. They deliver the treatments directly to their EPID without phantom or couch in the beam. They also deliver a set of simple calibration fields. Collected EPID images are uploaded electronically. In the analysis, the dose is projected back into a virtual phantom and 3D gamma analysis is performed. 2D dose planes and linear dose profiles can be analysed when needed for clarification. Results: Pilot facilities covering a range of planning and delivery systems have performed data acquisition and upload successfully. Analysis showed agreement comparable to local experience with the method. Advantages of VESPA are (1) fast turnaround mainly driven by the facility’s capability to provide the requested EPID images, (2) the possibility for facilities performing the audit in parallel, as there is no need to wait for a phantom, (3) simple and efficient credentialing for international facilities, (4) a large set of data points, and (5) a reduced impact on resources and environment as there is no need to transport heavy phantoms or audit staff. Limitations of the current implementation of VESPA for trials credentialing are that it does not provide absolute dosimetry, therefore a Level 1 audit still required, and that it relies on correctly delivered open calibration fields, which are used for system calibration. Conclusion: The implemented EPID based IMRT audit system promises to dramatically improve credentialing efficiency for clinical trials and wider applications. VESPA for VMAT will follow soon.

60 APPLIED LIFE SCIENCES↗

Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data

This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Health and Safety Audit Design Manual

The Health and Safety Audit is an electronic audit tool developed by the Oak Ridge National Laboratory to assist in the identification and selection of health and safety measures when a home is being weatherized (i.e., receiving home energy upgrades), especially as part of the US Department of Energy (DOE) Weatherization Assistance Program, or during home energy-efficiency retrofit or remodeling jobs. The audit is specifically applicable to existing single-family homes (including mobile homes), and is generally applicable to individual dwelling units in low-rise multifamily buildings. The health and safety issues covered in the audit are grouped in nine categories: mold and moisture, lead, radon, asbestos, formaldehyde and volatile organic compounds (VOCs), combustion, pest infestation, safety, and ventilation. Development of the audit was supported by the US Department of Housing and Urban Development Office of Healthy Homes and Lead Hazard Control and the DOE Weatherization Assistance Program.

47 OTHER INSTRUMENTATION↗

Photovoltaic system criteria documents. Volume 6: Criteria for auditing photovoltaic system applications and experiments. Revision A

The criteria is defined for auditing photovoltaic system applications and experiments. The purpose of the audit is twofold: to see if the application is meeting its stated objectives and to measure the application's progress in terms of the National Photovoltaic Program's goals of performance, cost, reliability, safety, and socio-environmental acceptance. The information obtained from an audit will be used to assess the status of an application and to provide the Department of Energy with recommendations on the future conduct of the application. Those aspects are covered of a site audit necessary to produce a systematic method for the gathering of qualitative and quantitative data to measure the success of an application. A sequence of audit events and guidelines for obtaining the required information is presented.

Koenig, John C.↗

John F. Kennedy Space Center, Safety, Reliability, Maintainability and Quality Assurance, Survey and Audit Program

This document is the product of the KSC Survey and Audit Working Group composed of civil service and contractor Safety, Reliability, and Quality Assurance (SR&QA) personnel. The program described herein provides standardized terminology, uniformity of survey and audit operations, and emphasizes process assessments rather than a program based solely on compliance. The program establishes minimum training requirements, adopts an auditor certification methodology, and includes survey and audit metrics for the audited organizations as well as the auditing organization.

Source record↗

The Functional Resonance Analysis Method for a systemic risk based environmental auditing in a sinter plant: A semi-quantitative approach

Environmental auditing is a main issue for any production plant and assessing environmental performance is crucial to identify risks factors. The complexity of current plants arises from interactions among technological, human and organizational system components, which are often transient and not easily detectable. The auditing thus requires a systemic perspective, rather than focusing on individual behaviors, as emerged in recent research in the safety domain for socio-technical systems. We explore the significance of modeling the interactions of system components in everyday work, by the application of a recent systemic method, i.e. the Functional Resonance Analysis Method (FRAM), in order to define dynamically the system structure. We present also an innovative evolution of traditional FRAM following a semi-quantitative approach based on Monte Carlo simulation. This paper represents the first contribution related to the application of FRAM in the environmental context, moreover considering a consistent evolution based on Monte Carlo simulation. The case study of an environmental risk auditing in a sinter plant validates the research, showing the benefits in terms of identifying potential critical activities, related mitigating actions and comprehensive environmental monitoring indicators. - Highlights: • We discuss the relevance of a systemic risk based environmental audit. • We present FRAM to represent functional interactions of the system. • We develop a semi-quantitative FRAM framework to assess environmental risks. • We apply the semi-quantitative FRAM framework to build a model for a sinter plant.

54 ENVIRONMENTAL SCIENCES↗

SU-F-T-485: Independent Remote Audits for TG51 NonCompliant Photon Beams Performed by the IROC Houston QA Center

Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specific geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI.

60 APPLIED LIFE SCIENCES↗

Sault Tribe Building Efficiency Energy Audits

The Sault Ste. Marie Tribe of Chippewa Indians is working to reduce energy consumption and expense in Tribally-owned governmental buildings. The Sault Ste. Marie Tribe of Chippewa Indians will conduct energy audits of nine Tribally-owned governmental buildings in three counties in the Upper Peninsula of Michigan to provide a basis for evaluating and selecting the technical and economic viability of energy efficiency improvement options. The Sault Ste. Marie Tribe of Chippewa Indians will follow established Tribal procurement policies and procedures to secure the services of a qualified provider to conduct energy audits of nine designated buildings. The contracted provider will be required to provide a progress schedule to the Tribe prior to commencing the project and submit an updated schedule with their monthly billings. Findings and analysis reports will be required for buildings as completed, and a complete Energy Audit Summary Report will be required to be submitted with the provider?s final billing. Conducting energy audits of the nine governmental buildings will disclose building inefficiencies to prioritize and address, resulting in reduced energy consumption and expense. These savings will allow Tribal resources to be reallocated to direct services, which will benefit Tribal members and families.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗