Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANSYS Fluent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor

This work studies the hydrodynamics of the seven pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. Here, the scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number Re. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of Re values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f Exp agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ±7% but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method (y + ~ 1) with the Shear Stress Transport k - ω turbulence model and the scalable wall functions (y + > 12) with the realizable k - ε turbulence model can predict f Exp within ±5% The standard wall functions (y + > 30) and nonequilibrium wall functions (y + > 30) with the realizable k - ε model can predict f Exp within ±10%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bayesian Parameter Estimation of the k-ω Shear Stress Transport Model for Accurate Simulations of Impinging-Jet Heat Transfer

Given the lack of fusion-relevant component test facilities, current estimates of the thermo-fluid performance of plasma-facing components are based for the most part on numerical simulations. A major source of uncertainty in these simulations is the semiempirical turbulence (closure) models for the Reynolds stresses appearing in the governing Reynolds-averaged Navier-Stokes equations, which involve a set of constants that depend upon the flow. The objective of this study is to evaluate Bayesian parameter estimation of turbulence closure constants in ANSYS Fluent to model heat transfer in impinging jets. The Bayesian statistical calibration produces a probability distribution for these constants from experimental data; the maximum a posteriori estimates are then taken to be the calibrated constants, or parameters. The turbulence model constants are calibrated using an experimental study of a submerged jet of air impinging on a flat heated surface at Reynolds numbers Re = O(10 4 ) and impingement distance in jet diameters H/d = 2. Numerical predictions using the calibrated model parameters are then compared with those generated using the default constants. Predictions obtained with model parameters calibrated on datasets of two different sizes are compared to evaluate the effect of the number of calibration samples. Lastly, the extrapolative ability of the calibrated model is examined by predictions at a Re beyond the calibration values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Channel Flow with Square Ribs for Blanket First-Wall Cooling: Geometry-Specific Tuning of k-ω Model Using Adjoint Method

Cooling of the plasma-facing first wall is challenging in the design of blanket components because of the high heat flux (on the order of 𝑀𝑊/𝑚2) from the plasma, especially when a low thermal mass medium like helium is chosen as the coolant. Therefore, heat transfer enhancement in which the convective heat transfer rate is augmented by the addition of turbulence-promoting structures becomes a key initiative for providing sufficient cooling capability with helium. Previously, computational fluid dynamics simulations had been performed on pipe flows with different transverse and longitudinal ribbed geometries at Oak Ridge National Laboratory to compare the enhancement performance among different ribbed geometries. Rib shape morphing had been conducted to obtain an optimized rib profile. In the work presented here, the adjoint method is adopted in the ANSYS Fluent solver for turbulence model augmentation, and the Generalized k-ω (GEKO) turbulence model is employed because of its ability of tuning the turbulence model. The Nusselt number and pressure drop obtained from the channel flow with bottom ribbed wall experiments are used as the targets. Sensitivity analysis provides information as guidance to improve the turbulence model accuracy. The augmented GEKO model is tuned for the studied ribbed channel geometry and flow conditions, providing improved predictive accuracy within this context. Extension to other configurations offers potential but may require additional tuning and validation.

Xu, Tracy [ORNL] (ORCID:0009000193700887)↗

Power handling in a highly-radiative negative triangularity pilot plant

Abstract This work explores detailed power handling solutions for a class of high-field, highly-radiative negative triangularity (NT) reactors based around the MANTA concept (Rutherford et al 2024 Plasma Phys. Control. Fusion ). The divertor design is kept as simple as possible, opting for a standard divertor with standard leg length. FreeGS is used to create an equilibrium for the boundary region, prioritizing a short outer leg length of only ∼50 cm (∼40% of the minor radius). The UEDGE code package is used for the boundary plasma solution to track plasma temperatures and fluxes to the divertor targets. It is found that for P SOL = 25 MW and n sep = 0.96 × 10 20 m −3 , conditions consistent with initial core transport modeling, little additional power mitigation is necessary. For a fixed impurity fraction of just 0.13% Ne in the plasma, the peak heat flux density at the more heavily loaded outer targets falls to 7.8 MW m −2 , while the electron temperature T e remains just under 5 eV. Scans around the parameter space reveal that even at densities lower than in the primary operating scenario, P SOL can be increased up to 50 MW, so long as a slightly higher fraction of extrinsic radiator is used. With less than 1% neon (Ne) impurity content, the divertor still experiences less than 10 MW m −2 at the outer target. Design of the plasma-facing components includes a close-fitting vacuum vessel with a tungsten inner surface as well as FLiBe-carrying cooling channels fashioned into the VV wall directly behind the divertor targets. For the seeded heat flux profile, Ansys Fluent heat transfer simulations estimate that the outer target temperature remains at just below 1550 ∘ C. Initial scoping of advanced divertor designs shows that for an X-divertor, detachment of the outer target becomes much simpler, and plasma fluxes to the targets drop considerably with only 0.01% Ne content.

Miller, M. A. (ORCID:0000000265406533)↗

Bayesian parameter estimation and evaluation of the K -ω shear stress transport model for plane impinging jets

Numerical simulations with semi-empirical turbulence models are commonly used to model impinging jets, often used for cooling solid surfaces. In this work, the constants in the k-ω shear stress transport model in ANSYS FLUENT are calibrated to experimental velocity and heat transfer data for a plane turbulent impinging air jet to determine if Kennedy-O'Hagan calibration (Kennedy and O'Hagan 2001 J. R. Stat. Soc. B 63 425–64) can improve predictions of near-surface velocities and surface Nusselt numbers for similar flows. Impinging jets have been proposed to cool the target plates of the divertor in future magnetic fusion energy reactors, where simulations are used to estimate divertor performance. The flat-plate divertor (Wang et al 2009 Fusion Sci. Technol .56 1023–7) uses a plane jet of helium issuing from a B = 0.5 mm slot to cool a surface with radius of curvature of 44 B at a distance 4 B from the slot. Predictions from the calibrated numerical model are compared with independent experimental data at different flow conditions, as well as surface temperature data for a flat plate divertor test section. The contribution of this work is evaluation of the accuracy of a calibrated turbulence model for modest extrapolations in flow geometry and flow conditions for a plane impinging jet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Pairing Directional Solar Inputs From Ray Tracing to Solar Receiver/Reactor Heat Transfer Models on Unstructured Meshes: Development and Case Studies

A novel method for pairing surface irradiation and volumetric absorption from Monte Carlo ray tracing to computational heat transfer models is presented. The method is well-suited to directionally and spatially complex concentrated radiative inputs (e.g., solar receivers and reactors). The method employs a generalized algorithm for directly mapping absorbed rays from a Monte Carlo ray tracing model to boundary or volumetric source terms in the computational mesh. The algorithm is compatible with unstructured, two and three-dimensional meshes with varying element shapes. Four case studies were performed on a directly irradiated, windowed solar thermochemical reactor model to validate the method. The method was shown to conserve energy and preserve spatial variation when mapping rays from a Monte Carlo ray tracing model to a computational heat transfer model in ansys fluent.

14 SOLAR ENERGY↗

On-Sun Testing of a High-Temperature Solar Receiver's Flux Distribution

Concentrated solar power (CSP) is a promising technology in transitioning to renewable energy because of its abundance in nature and thermal energy storage (TES) capability. Among the four types of available CSP technology, including parabolic trough, linear Fresnel, power tower, and parabolic dishes, a power tower using a central receiver has more potential to generate high-temperature heat in a scale supporting power cycles efficiency and achieve low levelized cost of energy (LCOE). Other than the conventional type of receiver design, the high-absorptive receiver concept developed and presented in this paper is novel in its design approach. The novel receiver design originated from National Renewable Energy Laboratory (NREL) consists of an array of solar flux absorb tubes. The solar absorb tubes require uniform flux distribution and in-depth flux penetration through the three different reflective sections of tubes in a hexagonal shape. To evaluate this unique receiver design and thermal performance, the flux distribution, flux uniformity, and intensity were numerically simulated using ansys fluent and SolTrace modeling program. On-sun testing has been done at NREL high flux solar testing facility, based on the computational analysis.

clean energy↗

Three-Dimensional Permeability of Thick-Section Glass Fabric Reinforced Polymer Composite by Vacuum-Assisted Resin Infusion Molding

Abstract Determination of permeability of thick-section glass fabric preforms with fabric layers of different architectures is critical for manufacturing large, thick composite structures with complex geometry, such as wind turbine blades. The thick-section reinforcement permeability is inherently three-dimensional and needs to be obtained for accurate composite processing modeling and analysis. Numerical simulation of the liquid stage of vacuum-assisted resin infusion molding (VARIM) is important to advance the composite manufacturing process and reduce processing-induced defects. In this research, the 3D permeability of thick-section E-glass fabric reinforcement preforms is determined, and the results are validated by a comparison between flow front progressions from experiments and from numerical simulations using ansys fluent software. The orientation of the principal permeability axes were unknown prior to experiments. The approach used in this research differs from those in literature in that the through-thickness permeability is determined as a function of flow front positions along the principal axes and the in-plane permeabilities and is not dependent on the inlet radius. The approach was tested on reinforcements with fabric architectures which vary through-the-thickness direction, such as those in a spar cap of a wind turbine blade. The computational simulations of the flow-front progression through-the-thickness were consistent with experimental observations.

Engineering↗

Effect of Quartz Aperture Covers on the Fluid Dynamics and Thermal Efficiency of Falling Particle Receivers

Falling particle receivers are an emerging technology for use in concentrating solar power systems. In this paper, quartz half-shells are investigated for use as full or partial aperture covers to reduce receiver thermal losses. Quartz half-shell aperture covers offer the ability to minimally interfere with incoming solar radiation from the heliostat field while obstructing thermal radiation and advection from leaving the receiver cavity. The fluid dynamics and heat transfer of a receiver subdomain and surrounding air are modeled using ANSYS®FLUENT We compare the percentage of total incident solar power lost due to conduction through the receiver walls, advective losses through the aperture, and radiation exiting the aperture. Contrary to expected outcomes, results show that quartz aperture covers can increase radiative losses and result in modest to nonexistent reductions in advective losses. The increased radiative losses are driven by elevated quartz half-shell temperatures and have the potential to be mitigated by active cooling and/or material selection. Quartz half-shell total transmissivity was measured experimentally using a radiometer and the National Solar Thermal Test Facility heliostat field with values up to 0.97 ± 0.01. Quartz half-shell aperture covers did not yield expected efficiency gains in numerical results due to increased radiative losses, but efficiency improvement in some numerical results and the performance of quartz half-shells subject to concentrated solar radiation suggest that quartz half-shell aperture covers should be investigated further.

14 SOLAR ENERGY↗

An Investigation of the Effects of Volume Fraction on Drag Coefficient of Non-Spherical Particles Using PR-DNS

Prediction of the drag coefficient is required in gas-particle multiphase flow modeling and simulation. Experimental data and correlations on the fixed-bed system of spherical particles with high volume fractions for various possible arrangements are available in the literature. However, the effect of volume fraction on the drag coefficient of non-spherical particles is not well studied. In solving the momentum equation, the volume fraction plays a vital role in determining the flow resistances. In this paper, we study the impact of volume fraction in the range of 0.069 to 0.65 on the drag coefficient using the computational fluid dynamics (CFD) simulation of air for Reynold number in the range of 10 to 10000 using particle resolved direct numerical solution (PR-DNS). Regular non-spherical particles such as a cube, tetrahedron, and spheroids are used in this study since their single particle’s drag coefficient data are available in the literature for comparison. For this work, the simulations are carried out in the Ansys Fluent using polyhedral mesh, which consumes significantly less computational time and power. The study showed the sphericity and volume fraction have significant impact on the bed pressure drop and average drag coefficient of the particles in the bed especially in high Reynolds number regime. The bed of the spheroid experiences the lowest drag being the most streamlined particle, and the particles with the edges result in a large drag coefficient due to flow separation at the discontinuity. The vector plots verify this behavior where large wake regions are observed behind the tetrahedron particle.

Mahyawansi, Pratik↗

Numerical simulation of mold filling water blown polyurethane foams: Effects of sequential pour

Batch molding of polyurethane foams is a widely used processing technique to produce crosslinked cellular structures which form to the shape of the mold. For water-blown polyurethane foams, water is reacted to form gaseous carbon dioxide resulting in a foam which expands to fill the mold completely. Batch molding typically requires an operator to coat the surface of a mold, introducing a significant lag time during the filling stage where significant asymmetric volume change can occur. The purpose of this work is to show, through simulations, that this lag time is significant when predicting flow profiles and part quality. When the mold geometry is complex enough to force bifurcation of the flow, simulations incorporating various filling lag times predicted significantly different locations of knit or weld lines where the flow fronts meet. Current simulation techniques, which assume the filling stage occurs instantaneously, are unable to predict variations in weld line locations. The introduction of a lag time, referred to herein as sequential pour, was achieved through user-defined modules incorporated into Ansys Fluent software.

36 MATERIALS SCIENCE↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

CFD Analysis of RLUOB Zone 1 HEPA Filter Plenum and Testing Manifolds

The purpose of this computational fluid dynamics (CFD) analysis is to ensure that Camfil Farr’s upstream and downstream injection and sampling manifolds can meet or exceed the requirements outlined in the ASME AG-1 1997 a(2000) Code on Nuclear Air and Gas Treatment for the testing of HEPA and adsorbent filters. This paper will present a numerical simulation of airflow in the Radiological Laboratory Utility Office Building (RLUOB) zone 1 HEPA filter plenum and testing manifolds using the commercial CFD software ANSYS FLUENT 2020R1. The CFD analysis focuses on the investigation of the air flow distribution and air-aerosol mixing uniformity. The evaluation was done for all steps of the modeling process: grid generation, physics setup, simulation, and post-processing. The mass flow rate in each section of the zone 1 injection and sampling manifolds is also reported.

42 ENGINEERING↗

Perovskite Sorbent Oxygen Separation Modeling with MFiX

This document chronicles the development and implementation of computational kinetic rate models that capture absorption and desorption characteristics of the National Energy Technology Laboratory (NETL) developed perovskite, Sr 1-x Ca x FeO 3-δ . Two paths to create accurate kinetic rates were followed: (1) an isothermal rate approach where thermogravimetric (TGA) data are recast as oxygen capacities through a pseudo-second order Lagergren equation (He et al., 2009); and (2) a more traditional Arrhenius approach where experimental data are fit with a power law model to derive associate activation energies (Bulfin et al., 2020a). For reference, the mathematics and associate experimental strategies that support these derivations are included in this report. In addition, computational fluid dynamics (CFD) models were developed to utilize both kinetic rate formulations and applied to simulate oxygen uptake and release in small scale scenarios. The program Multiphase Flow with interphase eXchanges (MFiX) was used to create: (1) discrete element method (DEM) simulations of a single tube of granular perovskite experiencing isothermal O 2 -absorption; and desorption and (2) two-fluid-model (TFM) non-isothermal simulations of perovskite O 2 -absorption and desorption tubes that share a wall. Conjugate heat transfer between steel walled tubes and the perovskite bed were managed with user-defined functions. As the project moves to simulating larger scale devices that will require more robust conjugate heat transfer methods, developed kinetic rates and associate methodologies have been recast for use in the ANSYS Fluent CFD program.

36 MATERIALS SCIENCE↗

A numerical evaluation of the ambient air temperature in the Electron-Ion Collider tunnel

The Electron-Ion Collider (EIC) is a next-generation collider-accelerator that may require consistent operating temperature conditions for the beams within the accelerator tunnels to maintain stable operation. Variations in ambient temperature within the tunnel can cause thermal expansion of beampipe and component supports and can negatively affect the tunnel equipment, impacting the stability of the beamline. Modifications will be made to the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) to create the EIC, which necessitates a temperature model that addresses these modifications. To approach this problem, the consistency of temperature changes in different tunnel sections was first evaluated by plotting RHIC tunnel temperature data at various times of the day and year. From this data, a tunnel section was selected and a 2D temperature model was created for RHIC, EIC, and EIC with added cooling configurations. Soil temperature data was analyzed to determine the maximum, average, and mode soil temperatures, which were used as boundary conditions in different temperature scenarios. Computational fluid dynamics modeling was used to create 2D temperature profiles for the configurations. From this model, the predicted temperatures indicate that further analysis is required to validate the boundary conditions and benchmark the current conditions to allow the prediction of the tunnel ambient conditions at EIC. This research can be used as a preliminary model to create an EIC tunnel cooling system that will increase the operational stability of the EIC. As a result of my work this summer, I have become familiar with computational fluid dynamics, including creating fluid dynamic simulations using ANSYS Fluent and related software. I have also learned about the project process required for planning large-scale engineering projects.

43 PARTICLE ACCELERATORS↗