Cleaning By Blasting With Pellets Of Dry Ice

Dry process strips protective surface coats from parts to be cleaned, without manual scrubbing. Does not involve use of flammable or toxic solvents. Used to remove coats from variety of materials, including plastics, ceramics, ferrous and nonferrous metals, and composites. Adds no chemical-pollution problem to problem of disposal of residue of coating material. Process consists of blasting solid carbon dioxide (dry ice) pellets at surface to be cleaned. Pellets sublime on impact and pass into atmosphere as carbon dioxide gas. Size, harness, velocity, and quantity of pellets adjusted to suit coating material and substrate.

Fody, Jody↗

Clean then Assemble Versus Assemble then Clean: Several Comparisons

Cleanliness of manufactured parts and assemblies is a significant issue in many industries including disk drives, semiconductors, aerospace, and medical devices. Clean manufacturing requires cleanroom floor space and cleaning technology that are both expensive to own and expensive to operate. Strategies to reduce these costs are an important consideration. One strategy shown to be effective at reducing costs is to assemble parts into subassemblies and then clean the subassembly, rather than clean the individual parts first and then assemble them. One advantage is that assembly outside of the cleanroom reduces the amount of cleanroom floor space and its associated operating cost premium. A second advantage is that this strategy reduces the number of individual parts that must be cleaned prior to assembly, reducing the number of cleaning baskets, handling and, possibly, reducing the number of cleaners. The assemble then clean strategy also results in a part that is significantly cleaner because contamination generated during the assembly steps are more effectively removed that normally can be achieved by hand wiping after assembly in the cleanroom.

contamination↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

Additive Manufacturing processes allow for the manufacture of complex three dimensional components that otherwise could not be manufactured. Post treatment processes require the removal of any remnant bulk powder that may become entrapped within small cavities and channels within a component. This project focuses on several gross cleaning methods and the verification metrics associated with additive manufactured parts for oxygen propulsion usage.

Mitchell, Mark A.↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surface of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The six commonly used methods for establishing objective cleanliness acceptance limits will be discussed. Special emphasis shall focus on the use of multiple extraction, a technique that has been demonstrated for additively manufactured parts.

Welker, Roger W.↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surfaces of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The methods for establishing objective cleanliness acceptance limits will be discussed.

Mitchell, Mark A.↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surfactant/Supercritical Fluid Cleaning of Contaminated Substrates

CFC's and halogenated hydrocarbon solvents have been the solvents of choice to degrease and otherwise clean precision metal parts to allow proper function. Recent regulations have, however, rendered most of these solvents unacceptable for these purposes. New processes which are being used or which have been proposed to replace these solvents usually either fail to remove water soluble contaminants or produce significant aqueous wastes which must then be disposed of. In this work, a new method for cleaning surfaces will be investigated. Solubility of typical contaminants such as lubricating greases and phosphatizing bath residues will be studied in several surfactant/supercritical fluid solutions. The effect of temperature, pressure, and the composition of the cleaning mixture on the solubility of oily, polar, and ionic contaminants will be investigated. A reverse micellar solution in a supercritical light hydrocarbon solvent will be used to clean samples of industrial wastes. A reverse micellar solution is one where water is dissolved into a non-polar solvent with the aid of a surfactant. The solution will be capable of dissolving both water-soluble contaminants and oil soluble contaminants. Once the contaminants have been dissolved into the solution they will be separated from the light hydrocarbon and precipitated by a relatively small pressure drop and the supercritical solvent will be available for recycle for reuse. The process will be compared to the efficacy of supercritical CO2 cleaning by attempting to clean the same types of substrates and machining wastes with the same contaminants using supercritical CO2. It is anticipated that the supercritical CO2 process will not be capable of removing ionic residues.

White, Gary L.↗

Bonding-Compatible Corrosion Inhibitor for Rinsing Metals

A corrosion-inhibiting mixture of compounds has been developed for addition to the water used to rinse metal parts that have been cleaned with aqueous solutions in preparation for adhesive bonding of the metals to rubber and rubber-like materials. Prior to the development of this corrosion inhibitor, the parts (made, variously, of D6AC steel and 7075-T73 aluminum) were rinsed by deionized water, which caused corrosion in some places on the steel parts especially in such occluded places as sealing surfaces and threaded blind holes. An integral part of the particular cleaning process is the deposition of a thin layer of silicates and silane primers that increase the strength of the adhesive bond. The corrosion inhibitor is formulated, not only to inhibit corrosion of both D6AC steel and 7075- T73 aluminum, but also to either increase or at least not reduce the strength of the adhesive bond to be formed subsequently. The corrosion inhibitor is a mixture of sodium silicate and sodium tetraborate. The sodium silicate functions as both a corrosion inhibitor and a bond-strength promoter in association with the silane primers. The sodium tetraborate buffers the rinse solution at the optimum pH and functions as a secondary corrosion inhibitor for the steel. For a given application, the concentrations of sodium silicate and sodium tetraborate must be chosen in a compromise among the needs to inhibit corrosion of steel, inhibit corrosion of aluminum, and minimize cosmetic staining of both steel and aluminum. Concentrations of sodium silicate in excess of 150 parts of silicon per million parts of solution (ppm Si) have been determined to enhance inhibition of corrosion; unfortunately, because of the alkalinity of sodium silicate, even a small concentration can raise the pH of the rinse solution to such a level that aluminum becomes corroded despite the inhibiting effect. The pH of a solution that contains a high concentration of sodium silicate can be decreased by adding sodium tetraborate. On the other hand, the addition of sodium tetraborate increases the concentration of dissolved solids to such a high level that cosmetic staining becomes an issue.

Saunders, C. R.↗

True Cost of Amateur Clean rooms

This viewgraph document reviews the cost factors for clean rooms that are not professionally built, monitored or maintained. These amateur clean rooms are built because scientist and engineers desire to create a clean room to build a part of an experiment that requires a clean room, and the program manager is looking to save money. However, in the long run these clean rooms may not save money, as the cost of maintenance may be higher due to the cost of transporting the crews, and if the materials were of lesser quality, the cost of modifications may diminish any savings, and the product may not be of the same quality. Several examples are shown of the clean rooms that show some of the problems that can arise from amateur clean rooms.

Ramsey, W. Lawrence↗

Super Clean, Super Safe

The Supersonic Gas/Liquid Cleaning System (SS-GLCS) has applications ranging from cleaning circuit boards to scouring building exteriors. The system does not abrade the surface of the hardware being cleaned, and it requires much lower levels of pressure while using very little water. An alternative to CFC-based solvents, the system mixes air and water from separate pressurized tanks, ejecting the gas- liquid mixture at supersonic speeds from a series of nozzles at the end of a hand-held wand. The water droplets have the kinetic energy to forcibly remove the contaminant material. The system leaves very little fluid that must be handled as contaminated waste. It can be applied in the aerospace, automotive, and medical industries, as well as to circuit boards, electronics, machinery, metals, plastics, and optics. With a nozzle that can be oriented in any direction, the system is adjustable to allow all sides of a part to be cleaned without reorientation. It requires minimal training and is easily moved on built-in casters

Source record↗

Automatic Flushing Unit With Cleanliness Monitor

Liquid-level probe kept clean, therefore at peak accuracy, by unit that flushes probe with solvent, monitors effluent for contamination, and determines probe is particle-free. Approach may be adaptable to industrial cleaning such as flushing filters and pipes, and ensuring that manufactured parts have been adequately cleaned.

Hildebrandt, N. E.↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Funding a Just Transition Away from Coal in the U.S. Considering Avoided Damage from Air Pollution

Abstract Coal is declining in the U.S. as part of the clean energy transition, resulting in remarkable air pollution benefits for the American public and significant costs for the industry. Using the AP3 integrated assessment model, we estimate that fewer emissions of sulfur dioxide, nitrogen oxides, and primary fine particulate matter driven by coal’s decline led to $300 billion in benefits from 2014 to 2019. Conversely, we find that job losses driven by less coal plant and mining activity resulted in $7.84 billion in foregone wages over the same timeframe. While the benefits were greatly distributed (mostly throughout the East), costs were highly concentrated in coal communities. Transferring a small fraction of the benefits to workers could cover these costs while maintaining societal net benefits. Forecasting coal fleet damages from 2020 to 2035, we find that buying out or replacing these plants would result in $589 billion in air quality benefits, which considerably outweigh the costs. The return on investment increases when policy targets the most damaging capacity, and net benefits are maximized when removing just facilities where marginal benefits exceed marginal costs. Evaluating competitive reverse auction policy designs akin to Germany’s Coal Exit Act, we find that adjusting bids based on monetary damages rather than based only on carbon dioxide emissions – the German design – provides a welfare advantage. Our benefit–cost analyses clearly support policies that drive a swift and just transition away from coal, thereby clearing the air while supporting communities needing assistance.

Dennin, Luke R. (ORCID:0000000205405520)↗

US-UK fusion energy collaborations in the digital space

The US and UK share the vision for fusion as a vital part of the clean energy future. This vision is reflected in the respective national plans in the form of the Bold Decadal Vision for Commercial Fusion (BDV) in the US and the Spherical Tokamak for Energy Production (STEP) program in the UK. Digital tools such as simulation and control frameworks, design tools, AI/ML, high performance computing (HPC), and virtual reality (VR) will play an important role in developing, diagnosing, operating, and further improving burning-plasma-class fusion power plants. Therefore, a collaborative approach, involving both the public and private sectors, to developing these digital tools can accelerate the path to fusion energy commercialization. In this report we discuss previous and ongoing collaborations and opportunities to expand these collaborations into new areas. We conclude this report with near term actions and a vision of the collaboration to the Joint Coordinating Committee.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long-Range Transport of Biomass Burning Aerosols from Southern Africa: A Case Study Using Layered Atlantic Smoke Interactions with Clouds Observations

A case study of an incoming biomass burning aerosol plume at Ascension Island is analyzed for the peak of the 2017 fire season using satellites, reanalysis and in situ observations. Measurements from the Atmospheric Radiation Measurement Mobile Facility 1 reveal an abrupt change from relatively clean conditions (~70 parts per billion by volume of carbon monoxide) to a more polluted state (~150 parts per billion by volume of carbon monoxide). Corresponding changes in aerosol size reveal a broadening of size distributions toward larger optical diameters, consistent with the arrival of aged aerosols. Within a 24 h period, black carbon fraction increases ~500% from ~300 ng m e to ~1500 ng m 3 , while light absorption coefficients increase ~300%. Long-range transport of these aerosols is primarily confined between 2 and 5 km above sea level along the northwesterly trade winds. Our results show that the primary driver of increases in aerosol loading over Ascension Island is an intensification of the St. Helena high-pressure system (anticyclone) that leads to a weakening of trade winds and increases westward transport on its northern flank. A better understanding of the complex interactions between air quality, meteorology and long-range aerosol transport is important for future modeling studies focused on aerosol–cloud–radiation interactions over the open ocean and reducing its associated uncertainties.

aerosol size distribution↗