Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

Fault Dataset Development for VAV Terminal Units: Damper and Airflow Sensor Faults

This report analyzes field data to understand the impact of faults in variable air volume (VAV) terminal units on building indoor conditions and heating, ventilation, and air-conditioning (HVAC) system operations. The Oak Ridge National Laboratory (ORNL) team conducted field tests at the commercial building test facility known as ORNL’s Flexible Research Platform (FRP) building. Two specific faults-damper malfunctions and airflow sensor inaccuracies- were implemented, as these are common faults in VAV terminal units and can significantly impact HVAC system performance by increasing energy consumption, causing occupant discomfort, and raising operational costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Forecasting Commercial Building Electricity Consumption, Zone Airflow and Zone Temperature: Update - Development of a Generalized Machine Learning Approach

The U.S. power grid is being transformed to make it smarter, more efficient, and cleaner. This transformation is leading to the addition of a significant of energy generated by distributed, variable, and renewable resources. Because of the variable nature of renewable generation, the short- and long-term supply and demand imbalances are less predictable, and conventional approaches to mitigating the imbalances will be less efficient or cost effective. To address this challenge and to support the mission and the vision of the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) Building Technologies Office has developed a Grid-Interactive Efficient Building Strategy. The strategy focuses on simultaneously improving building energy efficiency and supporting reliability and resilience of the electric grid more efficiently and at a lower cost. In addition, EERE and DOE’s Office of Electricity created an initiative led by DOE and supported by the national laboratories under the Grid Modernization Lab Consortium structure to enhance grid modernization. The work reported in this document is part of the first set of projects funded under the initiative to design, develop, and validate scalable transactive control technologies for the commercial buildings sector. Transactive controls requires the ability of individual end-use loads to express flexibility as a function of a transactive signal (e.g., price). Empirical grey- and black-box models have been widely used to express flexibility. Although this approach is generally easy to construct and simple to use, it does not capture non-linear behavior that some end-use loads represent. Therefore, Pacific Northwest National Laboratory (PNNL) with support from Western Washington University conducted this research to explore the use of deep machine learning (ML) techniques. The work reported in this document is limited to forecasting whole building electricity consumption, the zone airflow and the zone temperature predictions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact to Cooling Airflow from Truck Platooning

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.

adaptive cruise control (ACC)↗

Impact to Cooling Airflow from Truck Platooning: Preprint

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.

47 OTHER INSTRUMENTATION↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems

An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.

42 ENGINEERING↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗