Urban Air Quality Management at Low-Cost Using Micro Air Sensors: A Case Study From Accra, Ghana
Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to non-existent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of the high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was co-located at the Physics Department, University of Ghana with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of this data in identification of local sources and their behavior over time. For this study 15 weeks of data at hourly resolution with approximately 2500 data pairs are generated and analyzed (June 01, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2 ) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μgm -3 between the pre local calibration micro air sensor (i.e. out of box) and the reference-grade instrument. Following currently accepted best practice methods (see e.g., PAS4023) a domain specific (i.e. local) calibration factor was generated using a multi-linear regression model and when this factor is applied to the micro air sensor data, a reduction i.e., improvement in MAE to 1.43 μgm -3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of box, domain calibrated and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyper localized sources associated with urban areas, such as those found in major African cities.