AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps
Fuel compact temperatures are a crucial factor in assessing the irradiation performance of tri-structural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in the uncertainty of calculated fuel temperatures is the gas gap uncertainty due to the nub-to-shell clearance caused by a design error of AGR-5/6/7 capsules. The thermal model was revised to examine the most probable graphite offset position for six different days during the irradiation for Capsules 1 and 2. The analysis varied the offset distance and azimuthal direction at both the top and bottom of the holder. The best-fit offset was estimated based on the minimum root mean square error of the residuals (measured minus calculated) for the operational thermocouples (TCs). From these results, the following conclusions were made: (1) The holder offsets led to slightly lower average temperatures but wider temperature variations (lower minimum and higher peak fuel temperatures) for both Capsule 1 and Capsule 2. (2) During earlier cycles (162A–164B), when numerous TCs were still operational, the best-fit offset distance varied over a specific range for both the top and bottom ([0.002–0.0035 in.] for Capsule 1 and [0.003-0.004 in] for Capsule 2). In contrast, the offset azimuthal direction varied widely, especially for the offset at the bottom of the Capsule 1 holder. This is because holder movement was somewhat constrained at the top of Capsule 1 by the TC leads running through the capsule head and into the holder and by the through tubes in Capsule 2, but the Capsule 1 bottom did not have this type of constraint. (3) During later cycles, when all TCs failed, applying the maximum possible offset of 0.006 in. to the northwest direction for both the top and bottom resulted in a calculated peak fuel temperature of 1557? in Capsule 1 (i.e., a 135? increase from 1422? with zero offset on September 20, 2019 (166A)); the maximum offset of 0.0068 in. to the south for both top and bottom resulted in a calculated peak fuel temperature of 1110°C in Capsule 2 on April 20, 2020 (i.e., a 116? increase from 994? with zero offset (168A)). High peak fuel temperatures in Capsule 1 during Cycle 166A could be the cause of massive particle failure near the end of this cycle. (4) Even though the highest temperature at the tip of Type-N TCs, such as TC-1-7, slightly exceeded 1000?, the temperature along the TC wire reached as high as 1335? assuming an offset of 0.006 in. in the northwest of Capsule 1 holder near the end of Cycle 166A. This temperature significantly exceeds the temperature threshold at which TC degradation is expected to occur, ultimately contributing to considerable particle failures in Capsule 1. For eight Type-N TCs in Capsule 2, the peak TC line temperature was much lower (i.e., 1029°C for TC-2-5), assuming maximum offset of 00068 in. to the south during cycle 168A.