Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACTIVATION ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon Activation Analysis at the Idaho Accelerator Center

Activation methods require minimal sample preparation and provide sufficiently high sensitivity for detecting the vast majority of the elements throughout the periodic table. In this paper we shall discuss photon activation analysis (PAA) at the Idaho Accelerator Center. The process of PAA begins with exposing a sample with photons in the energy range of 10 to 30 MeV. Many nuclides in the sample will become activated and, in turn, these radionuclides will decay by emitting characteristic radiation. These characteristic radiation decays are the telltale signatures for identifying elements which can then be measured with spectrometers such as a high-purity Germanium detector. PAA is not an 'absolute' method, as the samples under investigation must be irradiated along with a reference or calibrating material having a well-known elemental composition. The quantitative evaluation is performed through comparing the two resulting element spectra from the unknown sample and reference material. Besides the obvious advantage of being non-destructive, PAA has minimal contamination issues. Moreover, materials that are difficult to treat chemically, such as certain refractory metals, dusts, ashes, etc., offer no hindrance to the technique of PAA. A further advantage is that PAA is very well suited for investigated minute samples (sub-milligram dust particles) to very large ones (in the multi-kg range). PAA is a robust technique as there are no real limitations concerning the nature of material to be studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Activation Analysis--An Analytical Application Of High-Energy Electron Accelerators

Photon activation analysis (PAA) was introduced about contemporarily with the other activation analysis methods (neutron, NAA, and charged particle activation, CPAA). Nonetheless, for different reasons, PAA has been applied less frequently than the other techniques mentioned. The incident photon energy should exceed about 12 MeV (except in some special rare applications) so as to obtain appreciably high activity yields of the product nuclides. Thus, cyclic electron accelerators (LINACs or microtrons) are used for activation preferably. The predominant photonuclear reaction is of the ({gamma},n)-type. Thus, normally neutron-deficient nuclides are produced. These usually emit gamma rays, annihilation quanta and characteristic X-ray fluorescence, all of whom can be used for analytical evaluation. The spectrometry equipment is the same as used for the other activation techniques (semiconductor detectors, sodium iodide crystals in coincidence geometry). Being uncharged high energy photons have a large penetration power, thus do not suffer from strong matrix absorption. Although not having a detection power as large as in NAA (in the most cases), PAA offers several further convincing advantages, e.g. several elements not or hardly detectable by NAA can be analysed: Titanium, nickel, thallium, lead, bismuth and, in particular, the light elements carbon, nitrogen, oxygen, fluorine, phosphorus. Several typical applications will be described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of the linac of the IREN facility for production some radionuclides and multielemental activation analysis

The possibility to develop multielemental activation analysis and production of some radionuclides widely used for the nuclear medicine, radiobiology and ecology monitoring at the linear electron accelerator (E{sub e}- = 75 MeV) of the facility IREN (FLNP, JINR) are considered. Based on the experimental data obtained at low energy (E{sub e}-<30 MeV) electron accelerators as well as the microtron MT-25 (FLNR, JINR) with the power 0.57 kW, are estimated photonuclear reaction yields for some radionuclides for the linear electron accelerator (E{sub e}- = 75 MeV). Technical parameter of the linac will be as follow as: the electron beam current 2.8 A in 100 microsecond impulse and frequency 50 Hz, that means the electron beam power -1.1 kW in the target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LaBr 3 : Ce self-activation analysis for measuring fast neutron fields

Measurement of the fast neutron production rate in deuterium–tritium (D–T) fusion reactions is important for applications such as active interrogation, fusion diagnostics, and borehole logging. Such measurements are typically performed by neutron activation analysis of metal foils, especially copper. Copper foil activation analysis requires efficiency and energy calibrations of the detector used to measure the foil, and it relies on the detection of 511 keV gamma rays, which are prominent in the active background when neutrons are being produced. Alternatives, such as 79m Br produced by inelastic neutron scattering on 79 Br, are limited by short half-life, low-energy gamma emission, and inability to selectively measure D–T neutrons. This work describes a novel alternative approach to measure ≳10 MeV neutron fields based on self-activation analysis of a LaBr 3 :Ce detector. The activity of 78 Br, the activation product of the 79 Br(n,2n) 78 Br reaction, is used to determine the neutron flux and infer the neutron production rate. We experimentally demonstrate the method with a cylindrical LaBr 3 :Ce crystal with a diameter and height of 3.81 cm that was placed at an ~18 cm distance from the neutron production point, at a 90° angle with respect to the deuteron beam in a D–T neutron generator. Operating voltage and current of the generator were adjusted to evaluate the technique’s performance over a nominal generator output range of approximately (1 - 9) x 10 7 n/s. The neutron output obtained from LaBr 3 :Ce activation agrees to within three standard deviations of the output obtained using copper activation. The self-activation technique can be conveniently employed in a variety of applications to simplify measurements of fast neutrons produced in D–T fusion reactions.

Active interrogationLaBr3↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of radioisotope tracer and activation analysis techniques for contamination monitoring in space environment simulation chambers

Radioisotope measurement techniques and neutron activation analysis are evaluated for use in identifying and locating contamination sources in space environment simulation chambers. The alpha range method allows the determination of total contaminant concentration in vapor state and condensate state. A Cf-252 neutron activation analysis system for detecting oils and greases tagged with stable elements is described. While neutron activation analysis of tagged contaminants offers specificity, an on-site system is extremely costly to implement and provides only marginal detection sensitivity under even the most favorable conditions.

Smathers, J. B.↗

Neutronics and activation analysis of lithium-based ternary alloys in IFE blankets

Here we report that an attractive feature of using liquid lithium as the breeder and coolant in fusion blankets is that it has very high tritium solubility and results in very low levels of tritium permeation throughout the facility infrastructure. However, lithium metal vigorously reacts with air and water and presents plant safety concerns. The Lawrence Livermore National Laboratory is carrying an effort to develop a lithium-based alloy that maintains the beneficial properties of lithium (e.g. high tritium breeding and solubility) and at the same time reduces overall flammability concerns. This study evaluates the neutronics performance of lithium-based alloys in the blanket of an inertial fusion energy chamber in order to inform such development. 3-D Monte Carlo calculations were performed to evaluate two main neutronics performance parameters for the blanket: tritium breeding ratio (TBR), and the fusion energy multiplication factor (EMF). It was found that elements that exhibit low absorption cross sections and higher q-values such as lead, tin, and strontium, perform well with those that have high neutron multiplication such as lead and bismuth. These elements meet TBR constrains ranging from 1.02 to 1.1. However, most alloys do not reach EMFs greater than 1.15. Additionally, it was found that enriching lithium significantly increases the TBR and decreases the minimum lithium concentration by more than 60%. The amount of enrichment depends on how much total lithium is in the alloy to begin with. Alloys that performed well in the TBR and EMF calculations were considered for activation analysis. Activation simulations were executed with 50 years of irradiation and 300 years of cooling. It was discovered that bismuth is a poor choice due to achieving the highest decay heat, contact dose rates, and accident doses. In addition, it does not meet the waste disposal ratings (WDR). Some of the activation results for alloys with tin, zinc, and gallium were in the higher end and should be considered secondary to elements such as strontium and barium that had overall better results. The results of this study along with other considerations such as thermodynamics, and chemical reactivity will help down select a preferred lithium ternary alloy.

36 MATERIALS SCIENCE↗

Neutron activation analysis for antimetabolites

Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

Source record↗

Orbital operations study. Volume 2: Interfacing activities analysis. Part 4: Support operations activity group

The findings of the support operations activity group of the orbital operations study are presented. Element interfaces, alternate approaches, design concepts, operational procedures, functional requirements, design influences, and approach selection are presented. The following areas are considered: (1) crew transfer, (2) cargo transfer, (3) propellant transfer, (4) attached element operations, and (5) attached element transport.

Steinwachs, W. L.↗

Epithermal Neutron Activation Analysis of Some Geological Samples of Different Origin

Instrumental Epithermal Neutron Activation Analysis was used to investigate the distribution of six major elements and 34 trace elements in a set of eight igneous and metamorphic rocks collected from Carpathian and Macin Mountainsas well as unconsolidated sediments collected from anoxic zone of the Black Sea. All experimental data were interpreted within the Upper Continental Core and Mid Ocean Ridge Basalt model system that allowed getting more information concerning samples origin as well as the environmental peculiarities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Priori Method of Using Photon Activation Analysis to Determine Unknown Trace Element Concentrations in NIST Standards

Photon activation analysis detected elements in two NIST standards that did not have reported concentration values. A method is currently being developed to infer these concentrations by using scaling parameters and the appropriate known quantities within the NIST standard itself. Scaling parameters include: threshold, peak and endpoint energies; photo-nuclear cross sections for specific isotopes; Bremstrahlung spectrum; target thickness; and photon flux. Photo-nuclear cross sections and energies from the unknown elements must also be known. With these quantities, the same integral was performed for both the known and unknown elements resulting in an inference of the concentration of the un-reported element based on the reported value. Since Rb and Mn were elements that were reported in the standards, and because they had well-identified peaks, they were used as the standards of inference to determine concentrations of the unreported elements of As, I, Nb, Y, and Zr. This method was tested by choosing other known elements within the standards and inferring a value based on the stated procedure. The reported value of Mn in the first NIST standard was 403{+-}15 ppm and the reported value of Ca in the second NIST standard was 87000 ppm (no reported uncertainty). The inferred concentrations were 370{+-}23 ppm and 80200{+-}8700 ppm respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nondestructive activation analysis of sample of lunar surface material returned by Luna 16 automatic station

The composition of a sample of lunar surface material returned by the Luna 16 automatic station from the Sea of Fertility was studied, using nondestructive activation analysis. The structure of the returned surface material is inhomogeneous; the surficial material is thin, quite homogeneous, and the granularity increases with depth. Based on grain size, the sample was separated into five zones. The activation analysis was conducted on a sample taken from the friable surficial layer, zone A. The content of Al, Mn, Na, Cr, Co, Fe, and Sc was determined by nondestructive activation analysis of the sample. In determining Cr, Co, Fe, and Sc, the sample was irradiated for 24 hours and cooled for 10 days. Gamma spectra of the samples were recorded with a semiconductor Ge(Li)-detector and a multichannel analyzer, and measurement data were processed with an electronic computer.

Chayko, M.↗