Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “61 RADIATION PROTECTION AND DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quality Assurance Plan for Federal Guidance Report 16

Federal Guidance Report No. 16 will provide risk coefficients for use in projecting the probability of cancer morbidity or mortality from exposure to environmental radionuclides. The derivation of nuclide-specific risk coefficients involves multiple steps, with each step relying on the accuracy of the previous step as well as the numerical data utilized within each step. Thus, to ensure the quality of the derived risk coefficients, it is necessary to evaluate and confirm the quality and proper implementation of input data at each step of the derivation. The Oak Ridge National Laboratory (ORNL) dosimetry research team currently has two largely independent software codes for deriving radiation dose estimates, dose coefficients, and cancer risk coefficients for internally deposited radionuclides: DCAL and QCAL. The agreement of derived values based on alternate codes is an important step in quality assurance (QA) of the risk coefficients produced in this project. DCAL is an integration of the dosimetric software and numerical databases developed at ORNL over the past 25 years for the EPA’s Office of Radiation and Indoor Air (ORIA). QCAL was developed in 2015 to serve as a substitute for DCAL while DCAL was undergoing revision and to provide QA for the updated version of DCAL. The complex methodology employed in the derivation of cancer risk coefficients presents a challenge for QA, and as such, this report describes the QA steps used by the ORNL dosimetry team in this process as implemented in DCAL and QCAL for Federal Guidance Report No. 16.

61 RADIATION PROTECTION AND DOSIMETRY↗

A biokinetic model for systemic sodium

This paper describes an updated biokinetic model for systemic sodium (Na), developed for use in a series of reports by the International Commission on Radiological Protection (ICRP) on occupational intake of radionuclides. In contrast to the ICRP's previous model for intake of radio-sodium by workers, the updated model depicts realistic directions of movement of Na in the body including recycling of activity between blood and tissues. The updated model structure facilitates extension of the baseline transfer coefficients for adults to different age groups and to special exposure scenarios such as transfer of radio-sodium from the mother to the foetus or the nursing infant. Dose coefficients for 22Na and 24Na based on the updated model generally do not differ greatly from those based on the ICRP's previous Na model when both models are connected to the ICRP's latest dosimetry system. The main exception is that the updated model yields roughly twofold higher dose coefficients for endosteal bone surface than does the previous model due to the dosimetrically cautious assumption in the updated model that exchangeable Na in bone resides on bone surface.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biokinetic and Dosimetric Models [Slides]

Presentation describes internal dosimetry as an intersection of disciplines involving Physiology, Anatomy, Physics, Mathematics and Computer Science, which some people call "The art of Internal Dosimetry". The basic components for internal dose calculations are: Biokinetic (metabolic) models describing the intake, distribution, retention and excretion of radionuclides in the body, Dosimetric models describing the interaction of radiation within the several body organs and tissues, and System of dose limitation.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary analysis of TREAT free-field experiments using OpenMC

This work analyses activation calculations for dosimetry materials during a steady-state irradiation in the Transient Reactor Test (TREAT) reactor core. Hence, we developed a workflow based on the Monte Carlo code OpenMC alongside a custom depletion solver. The irradiation-induced activity as a function of time is computed, and several sensitivity studies are performed to evaluate uncertainty. This study has shown activity computations are sensitive to flux amplitude, irradiation time, atoms quantity and microscopic cross sections. Stochastic uncertainties have been propagated to evaluate the activity uncertainty for each dosimetry material. Most uncertainties are below our target of 3%, which demonstrates OpenMC as a powerful predictive and analysis tool. The precise results obtained through this newly developed computation scheme will be used in future experiments to characterize quantities of interest when operating the TREAT reactor in new configurations.

61 - RADIATION PROTECTION AND DOSIMETRY↗

Internal Radiation Dose Evaluation For An Unruptured Post Release Tristructural Istropic Fuel Particle for Advanced and Micro-reactor Applications

There are unique benefits from advanced/micro reactor designs and fuel types that offer safety features in the case of an accident that may reduce environmental consequences compared to conventional reactors and fuels. Several micro reactor designs, for both civilian and military applications, are proposed using tristructural-isotropic (TRISO) fuel. TRISO particles are a robust advanced nuclear fuel type that leads to the unique question of how unruptured, activated TRISO particles will interact with humans. Human exposure to nuclear fuel, or radionuclides, includes all pathways of exposure. However, TRISO particles are 0.9 mm in size, and that particle size restricts internal dose assessment to the ingestion pathway; eliminating the inhalation and dermal absorption pathways. Furthermore, activity of the TRISO particle was established by High Temperature Engineering Test Reactor simulations assuming the TRISO particle was one day post-release from the reactor. International Commission of Radiological Protection publications 100 and 133 were used to develop the internal dosimetry model for an unruptured TRISO particle for the International Commission of Radiological Protection reference male and female dose assessment. The rectosigmoid colon had the highest internal organ dose for both reference male (2.1 Sv) and reference female (2.3 Sv). The internal dose from ingestion of the scenario-defined TRISO particle was 0.25 Sv for the reference male and 0.29 Sv for the refence female, which exceeds the annual occupational effective dose limit of 0.05 Sv in the code of federal regulations, 10.CFR.20 Subpart C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Review of Pantex Radiation Safety Department 2020 Backup Dosimetry Processing Methodology

In the first quarter (Q1) of Calendar Year 2020, the Pantex Radiation Safety Department (Pantex) experienced various issues and failures with their dosimeter processing equipment. Efforts to repair the equipment resulted in limited functionality without the ability to process dosimeters assigned to personnel for monitoring dose. As a result of the impairments to the dosimeter processing equipment, Pantex called upon Nevada National Security Site (NNSS) for support, as their designated backup processor. In January of 2021, LLNL Subject Matter Experts in External Dosimetry started an NNSA-requested review of Pantex’s personnel doses in Q1 2020. Its focus was the technical validity of the means and methods used by Pantex and its conclusions and provide a level of confidence to National Nuclear Security Administration (NNSA) that the resulting personnel doses were reasonable, conservative, and defensible.

61 RADIATION PROTECTION AND DOSIMETRY↗

RCT: Module 2.07 Respiratory Protection [Slides]

Internal dosimetry controls require the use of engineering controls to prevent the internal deposition of radioactive and non-radiological contaminants. However, when engineering and administrative controls are not available or feasible, respiratory protection may be necessary. The RCT should know and apply the considerations used in determining the respiratory protection equipment that is most appropriate for the job. The inappropriate use of or the use of the wrong respiratory protection equipment may result in undesirable health effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fundamentals of wildlife dosimetry and lessons learned from a decade of measuring external dose rates in the field

Methods for determining the radiation dose received by exposed biota require major improvements to reduce uncertainties and increase precision. We share our experiences in attempting to quantify external dose rates to free-ranging wildlife using GPS-coupled dosimetry methods. The manuscript is a primer on fundamental concepts in wildlife dosimetry in which the complexities of quantifying dose rates are highlighted, and lessons learned are presented based on research with wild boar and snakes at Fukushima, wolves at Chornobyl, and reindeer in Norway. GPS-coupled dosimeters produced empirical data to which numerical simulations of external dose using computer software were compared. Our data did not support a standing paradigm in risk analyses: Using averaged soil contaminant levels to model external dose rates conservatively overestimate the dose to individuals within a population. Following this paradigm will likely lead to misguided recommendations for risk management. The GPS-dosimetry data also demonstrated the critical importance of how modeled external dose rates are impacted by the scale at which contaminants are mapped. When contaminant mapping scales are coarse even detailed knowledge about each animal’s home range was inadequate to accurately predict external dose rates. Importantly, modeled external dose rates based on a single measurement at a trap site did not correlate to actual dose rates measured on free ranging animals. These findings provide empirical data to support published concerns about inadequate dosimetry in much of the published Chernobyl and Fukushima dose-effects research. Furthermore, our data indicate that a huge portion of that literature should be challenged, and that improper dosimetry remains a significant source of controversy in radiation dose-effect research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary analysis of TREAT free-field experiments using openmc

This work analyses activation calculations for dosimetry materials during a steady-state irradiation in the Transient Reactor Test (TREAT) reactor core. Hence, we developed a workflow based on the Monte Carlo code OpenMC alongside a custom depletion solver. The irradiation-induced activity as a function of time is computed, and several sensitivity studies are performed to evaluate uncertainty. This study has shown activity computations are sensitive to flux amplitude, irradiation time, atoms quantity and microscopic cross sections. Stochastic uncertainties have been propagated to evaluate the activity uncertainty for each dosimetry material. Most uncertainties are below our target of 3%, which demonstrates OpenMC as a powerful predictive and analysis tool. The precise results obtained through this newly developed computation scheme will be used in future experiments to characterize quantities of interest when operating the TREAT reactor in new configurations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Chelation Model Validation: Modeling of a Plutonium-238 Inhalation Incident Treated with DTPA at Los Alamos National Laboratory

Accidental inhalation of plutonium at the workplace is a non-negligible risk, even when rigorous safety standards are in place. The intake and retention of plutonium in the human body may be a source of concern. Thus, if there is a suspicion of a significant intake of plutonium, medical countermeasures such as chelation treatment may be administered to the worker. The present work aimed to interpret the bioassay data of a worker involved in an inhalation incident due to a glovebox breach at Los Alamos National Laboratory’s plutonium facility. The worker was treated with intravenous injections of calcium salts of diethylenetriaminepentaacetic acid (DTPA) in an attempt to reduce the amount of plutonium from the body and therefore reduce the internal radiation dose. It is well known in the internal dosimetry field that the administration of chelation treatment poses additional challenges to the dose assessment. Hence, a recently developed chelation model was used for the modeling of the bioassay data. The objectives of this work are to describe the incident, model the chelation-affected and non-affected bioassay data, estimate the plutonium intake, and assess the internal radiation dose.

238Pu↗

Cutaneous and local radiation injuries

The threat of a large-scale radiological or nuclear (R/N) incident looms in the present-day climate, as noted most recently in an editorial in Scientific American (March 2021). These large-scale incidents are infrequent but affect large numbers of people. Smaller-scale R/N incidents occur more often, affecting smaller numbers of people. There is more awareness of acute radiation syndrome (ARS) in the medical community; however, ionising radiation-induced injuries to the skin are much less understood. Here, this article will provide an overview of radiation-induced injuries to the skin, deeper tissues, and organs. The history and nomenclature; types and causes of injuries; pathophysiology; evaluation and diagnosis; current medical management; and current research of the evaluation and management are presented. Cutaneous radiation injuries (CRI) or local radiation injuries (LRI) may lead to cutaneous radiation syndrome, a sub-syndrome of ARS. These injuries may occur from exposure to radioactive particles suspended in the environment (air, soil, water) after a nuclear detonation or an improvised nuclear detonation (IND), a nuclear power plant incident, or an encounter with a radioactive dispersal or exposure device. These incidents may also result in a radiation-combined injury; a chemical, thermal, or traumatic injury, with radiation exposure. Skin injuries from medical diagnostic and therapeutic imaging, medical misadministration of nuclear medicine or radiotherapy, occupational exposures (including research) to radioactive sources are more common but are not the focus of this manuscript. Diagnosis and evaluation of injuries are based on the scenario, clinical picture, and dosimetry, and may be assisted through advanced imaging techniques. Research-based multidisciplinary therapies, both in the laboratory and clinical trial environments, hold promise for future medical management. Great progress is being made in recognising the extent of injuries, understanding their pathophysiology, as well as diagnosis and management; however, research gaps still exist.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optically stimulated luminescence dosimetry on mobile phone back protective glass

Protective glasses from the back of modern smartphones were tested as potential emergency dosimeters using optically stimulated luminescence (OSL). The glasses were shown to exhibit several favorable dosimetric properties including a strong sensitivity to radiation, a linear dose-response relationship from 0.1 to 8 Gy, a 3% reproducibility, and a minimum detectable dose in the low tens of milligray, even after significant fading. The OSL signal was observed to lose ~78% and ~90% of the original intensity over 1 h and 1 week, respectively; however, a fading curve was developed to correct for any such signal loss. A dose-recovery test demonstrated that reconstructed doses were capable of accuracies within 20%.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gene expression for biodosimetry and effect prediction purposes: promises, pitfalls and future directions – key session ConRad 2021

In a nuclear or radiological event, an early diagnostic or prognostic tool is needed to distinguish unexposed from low- and highly exposed individuals with the latter requiring early and intensive medical care. Radiation-induced gene expression (GE) changes observed within hours and days after irradiation have shown potential to serve as biomarkers for either dose reconstruction (retrospective dosimetry) or the prediction of consecutively occurring acute or chronic health effects. The advantage of GE markers lies in their capability for early (1–3 days after irradiation), high-throughput, and point-of-care (POC) diagnosis required for the prediction of the acute radiation syndrome (ARS).

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Testing of Personal Dosimetry Interference from a Portable X-ray Generator

The determination of the disposition route for a legacy drum in a nuclear facility at the Y-12 National Security Complex is supported by non-destructive testing of the drum and its contents. An advanced radiation measurements organization at the Y-12 National Security Complex proposed a series of active measurements using a portable x-ray generator, imaging the drum and its contents with 360-degree visualization. In rooms near the current storage location for the drum, Criticality Accident Alarm System (CAAS) annunciation is degraded, and Personal Radiation Dosimetry Instruments (PRDI’s) are routinely worn by personnel. The Y-12 Development Organization has procured advanced radiation detection devices and a variety of radiation sources for use in active measurements. These devices are being used to support Y-12 operations and safety engineering disciplines to safely address complex challenges throughout the complex. This paper presents the results of experimental testing of the PRDI’s used at Y-12 with the x-ray generator [1], and notes the unique utilization of a decommissioned facility for this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry and cancer risk estimations for different radiation protection solutions at decommissioning a contaminated nuclear power plant site

Contaminated sediments originating from dredging activities in a nuclear power plant site were placed in a pond, which has to be taken into consideration during the future decommissioning process. The sediments have to be handled to free release the site. The radionuclides Co-60 and Cs-137 were identified and the activity concentrations (Bq/kg) were quantified in the range of 10–6000 and 5–50 Bq kg -1 , respectively. The absorbed dose rate to individuals of various ages and sex present at the site of the dry pond area was estimated. The radiological impact in terms of lifetime attributable risk (LAR) and effective dose were calculated. For a 30-year-old male exposed during one year without any action regarding the sediments in the dried out pond, the LAR was predicted to be 0.0027, which recalculated to effective dose corresponds to 7.6 mSv year -1 . The calculations show that countermeasures will be needed for the contaminated site.

61 RADIATION PROTECTION AND DOSIMETRY↗