Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D temperature modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

DiffESM: Conditional Emulation of Temperature and Precipitation in Earth System Models With 3D Diffusion Models

Earth system models (ESMs) are essential for understanding the interaction between human activities and the Earth's climate. However, the computational demands of ESMs often limit the number of simulations that can be run, hindering the robust analysis of risks associated with extreme weather events. While low-cost climate emulators have emerged as an alternative to emulate ESMs and enable rapid analysis of future climate, many of these emulators only provide output on at most a monthly frequency. This temporal resolution is insufficient for analyzing events that require daily characterization, such as heat waves or heavy precipitation. We propose using diffusion models, a class of generative deep learning models, to effectively downscale ESM output from a monthly to a daily frequency. Trained on a handful of ESM realizations, reflecting a wide range of radiative forcings, our DiffESM model takes monthly mean precipitation or temperature as input, and is capable of producing daily values with statistical characteristics close to ESM output. Combined with a low-cost emulator providing monthly means, this approach requires only a small fraction of the computational resources needed to run a large ensemble. We evaluate model behavior using a number of extreme metrics, showing that DiffESM closely matches the spatio-temporal behavior of the ESM output it emulates in terms of the frequency and spatial characteristics of phenomena such as heat waves, dry spells, or rainfall intensity.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Postulated Accident Scenarios for the Transformational Challenge Reactor

The Transformational Challenge Reactor (TCR) is a helium-cooled, yttrium-hydride-moderated reactor that was designed for the U.S. Department of Energy Office of Nuclear Energy. A key objective of the TCR was to employ advanced manufacturing techniques in a nuclear system and demonstrate their potential for revolutionizing the nuclear reactor design process. One purpose of the present work is to demonstrate the safety of the TCR under postulated accidents. Based on RELAP5-3D and COMSOL analyses, the TCR remained below all current safety limits and far below the expected failure limits for the core materials. Another purpose of this work is to provide useful insights and recommendations regarding the application of RELAP5-3D to gas-cooled or other advanced reactors. A novel approach was implemented for simultaneously modeling conduction and radiation in RELAP5-3D, which was found to provide reasonable predictions of radial core, vessel, and ex-vessel heat transfer during postulated events. A multicode approach was also applied, in which high-fidelity COMSOL calculations were used to tune the radial heat transfer parameters in RELAP5-3D. The tuned RELAP5-3D model demonstrated comparable peak temperature predictions as COMSOL, despite a coarse treatment of the core in RELAP5-3D consisting of only two lumped heat structures. This high-fidelity tuning approach enabled enhanced accuracy as well as minimal complexity within the RELAP5-3D model, even for complex fuel geometric designs as in the TCR. Finally, investigations were made into the potential for flow reversal during a pressurized loss-of-forced-flow event in the TCR. The TCR is designed with downward helium flow through the core during normal operation. The RELAP5-3D model predicted that this downward flow would persist, without flow reversal, up to several days after the circulator trip. This was attributed to natural circulation hysteresis effects as have been noted in similar thermofluidic systems. Although flow stagnation and eventual reversal did not lead to unsafe TCR conditions, interesting spatial effects were observed which may have safety relevance for other reactor system designs and coolant types that are designed for downward core flow during normal operation, warranting closer investigation of the flow reversal phenomenon.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lessons Learned from RELAP5-3D Modeling of HTTF

Modeling of HTTF using the RELAP5-3D ring model has shown an inability to predict transient temperature rise during HTTF experiments. This presentation provides an overview of the RELAP5-3D ring model, the HTTF modeling activities using the ring model, and reasons why the models failed to reproduce measured temperature rise. It also presents an overview of the path forward for RELAP5-3D modeling of HTTF to better predict the behavior of HTTF experiments

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A RELAP5-3D Model of the Lobo Lead Loop

The goal of our research is to build upon the capability of RELAP5-3D to model molten lead systems. Molten lead has several potential uses in future advanced reactors like the lead fast reactor or fusion reactors that utilize dual-coolant lead lithium blankets. This potential for use in future generations of reactors highlights the necessity to develop molten lead models to ensure that they can accurately predict the thermohydraulic behavior. We have developed a RELAP5-3D model of the Lobo Lead Loop facility, located at the University of New Mexico, to verify the accuracy of RELAP5-3D via comparison to existing computational fluid dynamics results and analytical calculations. It was found that RELAP5-3D accurately calculated radiative heat transfer (within < 1%) when compared to theoretical calculations. In addition, pressure drop calculations done in RELAP5-3D demonstrated reasonable agreement within 20 kPa, mostly within ~7-15%, when compared to the computational fluid dynamics model of the facility developed by the University of New Mexico, and captured the dependence of pressure drop on flow velocity accurately. Finally, a hypothetical loss of flow transient was imposed on the RELAP5-3D model to determine the feasibility of performing a similar experiment with the Lobo Lead Loop. It was found that such an experiment could be possible as the RELAP5-3D model indicated that the temperatures of the fluid would not exceed limiting temperatures of the structure (1658 K) nor the maximum temperature of the electromagnetic pump inlet (823 K). Although there is not experimental data to begin validation, the model will be readily available for future validation studies when the experimental data is generated, especially as the model continues to evolve over time. Furthermore, the results so far demonstrate a promising first step in the verification/validation of the RELAP5-3D model of the Lobo Lead Loop.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Combined ambient vibration and surface displacement measurements for improved progressive failure monitoring at a toppling rock slab in Utah, USA

Seismic resonance and surface displacement measurements can be implemented in tandem to improve landslide characterization and progressive failure monitoring. Crack aperture data are frequently used in rock slope stability monitoring and often exhibit recognizable trends prior to failure, such as accelerated crack opening. Alternatively, ambient resonance data offer multiple parameters including modal frequencies, damping, and polarization that can be monitored alongside crack aperture and may respond differently to environmental forcings and complex failure evolution. We analyzed data from continuous ambient vibration monitoring and concomitant crack aperture measurements at the Courthouse Mesa instability, a large toppling sandstone slab in Utah, USA. Three years of data revealed crack aperture increases of 2–4 mm/year with no clearly detectable irreversible changes in modal parameters, including frequency. Annually, frequency and displacement varied by 29% and 19% of the mean, respectively, with average and maximum daily frequency fluctuations of 6.5% and 16%, respectively. These reversible cyclic changes were primarily temperature-driven, but annually, frequency was in-phase with temperature whereas crack aperture lagged temperature changes by ~37 days. Polarization and damping also varied seasonally but were less strongly correlated with temperature. Conceptual 3D finite element modeling demonstrated consistent frequency decreases associated with crack propagation but variable changes in crack aperture measured at a single point; i.e., crack propagation did not always result in increased crack opening but always generated a resonance frequency decrease. Taken together, our data suggest a possible thermal wedging-ratcheting mechanism at the Courthouse Mesa instability, where annual thermoelastic crack closure is impeded by debris infill but the absence of downward crack propagation during the monitoring period is evidenced by no permanent resonance frequency changes. Our study demonstrates that combined seismic resonance and crack aperture data provide an improved description of rock slope instability behavior, supporting refined characterization and monitoring of changes accompanying progressive failure.

58 GEOSCIENCES↗

Frequency-domain hot-wire sensor and 3D model for thermal conductivity measurements of reactive and corrosive materials at high temperatures

High temperature solids and liquids are becoming increasingly important in next-generation energy and manufacturing systems that seek higher efficiencies and lower emissions. Accurate measurements of thermal conductivity at high temperatures are required for the modeling and design of these systems, but commonly employed time-domain measurements can have errors from convection, corrosion, and ambient temperature fluctuations. Here, we describe the development of a frequency-domain hot-wire technique capable of accurately measuring the thermal conductivity of solid and molten compounds from room temperature up to 800 °C. Therefore, by operating in the frequency-domain, we can lock into the harmonic thermal response of the material and reject the influence of ambient temperature fluctuations, and we can keep the probed volume below 1 µl to minimize convection. The design of the microfabricated hot-wire sensor, electrical systems, and insulating wire coating to protect against corrosion is covered in detail. Furthermore, we discuss the development of a full three-dimensional multilayer thermal model that accounts for both radial conduction into the sample and axial conduction along the wire and the effect of wire coatings. The 3D, multilayer model facilitates the measurement of small sample volumes important for material development. A sensitivity analysis and an error propagation calculation of the frequency-domain thermal model are performed to demonstrate what factors are most important for thermal conductivity measurements. Finally, we show thermal conductivity measurements including model data fitting on gas (argon), solid (sulfur), and molten substances over a range of temperatures.

47 OTHER INSTRUMENTATION↗

Full Scale 3D Computational Model of the Industrial -Scale Coal Fired Boiler Performance for Temperature Sensor Installation Guidance

Abstract Nearly 30% of the electricity is generated by using coal as the primary fuel in the US. One of the major concerns in coal-fired power plants is the failure of boiler tubes that leads to unscheduled maintenance and has a huge economical and societal impact. High temperature flue gas along with ash pass over the boiler tubes, which over time leads to tube failure. Therefore, developing temperature sensors for harsh environments and install them for temperature sensing and boiler tube lifetime prediction is an urgent need. On the side of sensor development, the location of the sensor installation is important for stable sensing performance and easy calibration. In this study, computational fluid dynamics and heat transfer modeling are adopted to establish a full-scale 3-dimensional model of a coal-fired boiler to investigate the flue gas temperature distribution within the boiler and identify the proper locations for sensor installation. We proposed three criteria to select the temperature sensor installation location: (1) select the boiler tube panel away from the sidewalls, (2) select the boiler tube section closer to the top wall of the boiler; and (3) select the boiler tube on the back of the boiler panel (not directly facing the flue gas flow). In these regions, the flue gas temperature is stable, providing an ideal environment for stable temperature sensing and calibration.

Gupta, Tanuj↗

Implications of rootless geothermal models: Missing processes, parameter compensation, and imposter convection

Numerical models of geothermal systems commonly capture only the top of a reservoir. Deeper areas of the reservoir are simplified to a boundary at the base of the model domain. Commonly, the basal boundary is given either a heat source or a source of mass and enthalpy. Here we developed and present simple numerical experiments which demonstrate that these approaches do not produce the correct model behavior in comparison to a model that captures the entire convecting domain with a heat flux only. We describe a variety of incorrect types of model behavior that arise directly from the choice of boundary condition, independent of the specific parameterization of the model. Heat sources are sensitive to the thickness of the domain and parameters take unphysical values to compensate for the reduced height. The combined mass/heat boundary can produce temperatures that show similarities to circulating geothermal systems, but with incorrect fluid flow and a strong boundary layer focused at the base of the simulated clay cap. These errors likely cause parameters to adjust their values to compensate for the incorrect physics. We highlight these issues and show an example from a developed reservoir model. Initial calibrations to natural state temperature were unsuitable for history matching. The 3D model required parameter adjustments to achieve a more realistic production model. Appropriate mitigation measures should be considered to reduce parameter compensation and improve decision-support models.

15 GEOTHERMAL ENERGY↗

RELAP5-3D modelling of the HTTR-GT/H 2 secondary system and turbomachinery

High Temperature Gas-cooled Reactors (HTGRs) can be used for the cogeneration of electricity and hydrogen. The JAEA-operated High-Temperature engineering Test Reactor (HTTR-GT/H 2 ) is exploring using the reactor for electricity and hydrogen production. Here, a RELAP5-3D model of the HTTR-GT/H 2 secondary system has been developed using design information. The various components and heat exchangers in the secondary system were investigated, modified, and improved where applicable. With these changes made, the model was run, and the results were compared to the design conditions. The results for the sole-power generation mode were shown to fit the design conditions very well. The largest temperature difference was on the order of 7 K, and the largest pressure difference was on the order of 0.05 MPa. The results for the hydrogen cogeneration mode did not fit the design conditions as well as the other case. The largest temperature difference was about 39 K and the largest pressure difference was about 0.27 MPa at the compressor outlet. The larger differences for the hydrogen cogeneration mode are attributed to the various complex components and the flow being split in the secondary loop. A transient reduction in heat removal capability of the secondary system was investigated. Reactor temperatures were predicted to rise as a result. The core reactivity response due to this increase in temperature is investigated and is expected to add negative reactivity to the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Significant Increase in Detection of High-resolution Emission Spectra Using a Three-dimensional Atmospheric Model of a Hot Jupiter

High-resolution spectroscopy has opened the way for new, detailed study of exoplanet atmospheres. There is evidence that this technique can be sensitive to the complex, three-dimensional (3D) atmospheric structure of these planets. In this work, we perform cross-correlation analysis of high-resolution (R ∼ 100,000) CRIRES/VLT emission spectra of the hot Jupiter HD 209458b. We generate template emission spectra from a 3D atmospheric circulation model of the planet, accounting for temperature structure and atmospheric motions—winds and planetary rotation—missed by spectra calculated from one-dimensional models. In this first-of-its-kind analysis, we find that using template spectra generated from a 3D model produces a more significant detection (6.9σ) of the planet’s signal than any of the hundreds of one-dimensional models we tested (maximum of 5.1σ). We recover the planet’s thermal emission, its orbital motion, and the presence of CO in its atmosphere at high significance. Additionally, we analyzed the relative influences of 3D temperature and chemical structures in this improved detection, including the contributions from CO and H{sub 2}O, as well as the role of atmospheric Doppler signatures from winds and rotation. This work shows that the hot Jupiter’s 3D atmospheric structure has a first-order influence on its emission spectra at high resolution and motivates the use of multidimensional atmospheric models in high-resolution spectral analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of RELAP5-3D for transient analysis of a dual coolant lead lithium fusion blanket concept

Our research aims to build a multiphysics framework for transient analysis of the Dual- Coolant Lead-Lithium (DCLL) blanket design of the proposed Fusion Nuclear Science Facility (FNSF) for all Onticipated Operational Occurrences (AOOs) using Reduced Order Models (ROMs). This paper presents an assessment of using RELAP5-3D for transient thermal-hydraulic blanket analysis of the DCLL design. Preliminary validation studies for the RELAP5-3D properties were conducted using a representative vertical flow loop model and a comparison study using experimental data from the thermal convection corrosion loops at ORNL. These studies inspected the thermal hydraulic response of Lead-Lithium Eutectic (PbLi) systems within the RELAP5-3D code; mainly pressure drop and heat transfer, as compared to analytical calculations and experimental data. The Magnetohydrodynamic (MHD) pressure drop effect for liquid metal under the effects of a uniform magnetic field was implemented into our models using an equivalent forms loss coefficient based on the phasic momentum equations. We verified our implementation of MHD pressure drop within RELAP5-3D using a systematic approach consisting of two studies. Models were developed to perform comparison studies based on experimental data from the Argonne Liquid metal EXperiment (ALEX) facility and the Magnetohydrodynamic PbLi Experiment (MaPLE) facility. Using the developed validation basis, we built a simplified DCLL channel model within RELAP5-3D, inspected MHD pressure drop and performed transient temperature analysis. The DCLL channel model used radial heating data from the International Thermonuclear Experimental Reactor (ITER) which was normalized to the FNSF design. Here, a representative startup transient was performed using a relative power curve from the initial ramp up of a long-term power pulse of the Tore Supra reactor. This study demonstrated that RELAP5-3D ROMs are capable of accurate transient analysis of the DCLL blanket. We have since utilized MCNP to develop heating profiles based on the FNSF design and are working toward implementing them into our DCLL model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-temperature effects in Hall-MHD simulations of the HIT-SI experiment

A two-temperature Hall-magnetohydrodynamic (Hall-MHD) model, which evolves the electron and ion temperatures separately, is implemented in the PSI-Tet 3D MHD code and used to model plasma dynamics in the Helicity Injected Torus–Steady Inductive (HIT-SI) experiment. The two-temperature model is utilized for HIT-SI simulations in both the PSI-Tet and NIMROD codes at a number of different injector frequencies in the 14.5–68.5 kHz range. At all frequencies, the NIMROD two-temperature model results in increased toroidal current, lower chord-averaged density, higher average temperatures, outward radial shift of the current centroid, and axial symmetrization of the current centroid, relative to the single-temperature NIMROD simulations. The two-temperature PSI-Tet model illustrates similar trends, but at high frequency operation, it exhibits lower electron temperature, smaller toroidal current, and decreased axial symmetrization with respect to the single-temperature PSI-Tet model. With all models, average temperatures and toroidal currents increase with the injector frequency. Power balance and heat fluxes to the wall are calculated for the two-temperature PSI-Tet model and illustrate considerable viscous and compressive heating, particularly at high injector frequency. Parameter scans are also presented for artificial diffusivity, wall temperature, and density. Both artificial diffusivity and the density boundary condition significantly modify the plasma density profiles, leading to larger average temperatures, toroidal current, and relative density fluctuations at low densities. As a result, a low density simulation achieves sufficiently high current gain (G > 5) to generate significant volumes of closed flux lasting 1–2 injector periods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of RELAP5-3D Code with Molten Salt Heat Transfer Experiments

The accurate thermal-hydraulic assessment of thermal storage systems is crucial for addressing the integrity and performance of the storage system design. This is particularly important for thermal storage systems using molten salts as a heat transport and storage medium, as the chemical corrosion and erosion by the high-temperature molten salts can cause serious damage to the structural components of the storage system. To understand these effects for TerraPower’s Natrium® Demonstration Reactor design, the system thermal-hydraulic analysis code, RELAP5-3D, is utilized to analyze the thermal storage system. This study evaluates two heat transfer correlations implemented in the RELAP5-3D code—the Dittus-Boelter and Gnielinski correlations—using selected benchmark cases from two molten salt heat transfer experiments conducted at Xi’an Jiao Tong University and the German Aerospace Center. The Nusselt numbers calculated using the Gnielinski correlation agree with the experimental data within ±5% of the relative deviations at 300°C and 400°C. With the increasing Reynolds numbers, the Dittus-Boelter correlation underestimates the Nusselt numbers by up to 22% compared to the Gnielinski correlation. Comparison of the RELAP5-3D calculation results with experimental data at a high temperature of 550°C revealed that the thermo-chemical characteristics of solar salt at high temperatures surpassing the decomposition temperatures of nitrate salts reduce the accuracy of heat transfer model of the RELAP5-3D code. Specifically, it has been observed that the temperatures of the wall surface and liquid near the wall can surpass the decomposition temperatures, even though the bulk temperature of molten salts remains significantly lower than these decomposition temperatures. In summary, this study recommends the use of the Gnielinski correlation for the heat transfer analysis of molten salt, rather than the Dittus-Boelter correlation.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Thermomechanical Stress and Creep-Fatigue Analysis of a High-Temperature Prototype Receiver for Heating Particles

This work presents a three-dimensional (3D) thermomechanical model of a prototype-scale enclosed light trapping solar receiver for heating particles. Results of the thermoelastic model are used to estimate receiver lifetime under maximum flux conditions. A computational fluid dynamics (CFD) model is first developed to predict the temperature fields in a multi-panel assembly under steady operating conditions. Solar flux distributions on the receiver are obtained from the software package SolTrace and applied to the 3D thermal model. The subsequent particle heating is captured through a simplified 1D energy balance. Panel reradiation is considered through a surface-to-surface radiation model and natural convection loss to the surrounding air is captured in a representative fluid domain surrounding the receiver. The resulting temperature fields from the CFD analysis are used as inputs for a thermoelastic mechanical model with representative boundary conditions. With the resultant temperature and stress fields, a creep-fatigue damage and lifetime analysis is performed using the linear damage accumulation (LDA) theory. The Manson-Coffin formula and Larson Miller correlation are used to calculate the fatigue and creep, respectively. A maximum damage (corresponding to a 30-year service life) is defined for design assessment. The model was first developed and verified in detail by comparing with published results in the literature (temperature and stress profiles and distributions, and creep/fatigue damage fractions) for tubular solar receivers with supercritical carbon dioxide as the working fluid. It was then implemented to model a planar-cavity receiver with various design parameters. Specifically, three different design geometries are considered, and the results show that a maximum temperature of approximately 1200 K could be reached for each design with the given incident solar flux, with the main difference being the distribution of these temperatures. Preliminary resulting stresses for the small-scale prototype without design optimization vary from 20 MPa to 250 MPa for each design, with the maximum stresses occurring on the front face and concave geometry on the side of the panel. In future work, the developed methodology shown here will be applied to analyze a full-scale (50-150 MWth) receiver.

concentrated solar power↗

Calculation of Critical Heat Flux Using an Inverse Heat Transfer Method to Support TREAT Experiment Analysis

Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Development of a new RELAP5-35 Model of HTTF

Previous validation studies of RELAP5-3D against HTTF data demonstrated an ability to reproduce trends in temperature but an inability to reproduce the transient temperature rise. This is hypothesized to be the result of modeling decisions made when the initial RELAP5-3D model was develop prior to the experiments. To test this hypothesis, a new RELAP5-3D model is being developed. This presentation shows results from full power steady-state and in a pressurized conduction cooldown accident using the new model and compares them to results from the legacy model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-Dimensional Heat Flux and Thermal Analysis of Angled Tungsten Samples on DIII-D

ITER-grade tungsten and dispersoid-strengthened tungsten samples with the top surface angled at ~15° towards the incident plasma flux were exposed to 9 H-mode discharges with edge-localized modes (ELMs) in the lower divertor of DIII-D tokamak using the Divertor Material Evaluation System (DiMES). Surface damage included cracking and flaking of material on the two samples farthest away from the plasma strike point, and significant melting of the two samples closest to the strike point. Heat flux and thermal analysis tools new to DIII-D have been applied to better understand this material response and to help optimize the exposure conditions for future experiments. SMITER field-line tracing simulations based on IRTV data and EFIT equilibria estimate an average inter-ELM perpendicular heat flux, 𝑞⊥,𝑖nter−𝐸LM , on the angled surfaces of 10.1 – 19.6 MW/m² for a majority of the 9 discharges, increasing to 15.6 – 24.5 MW/m² for the single, higher-power shot where samples melted. Fast camera data showed shallow intra-ELM melting and re-solidification, which transitioned to bulk inter-ELM melting with melt motion in the 𝐽⃗ 𝑥 𝐵⃗ direction. About 50% of the protruding volume of the most affected sample was displaced via melt-motion. SIERRA thermal modeling software was able to reproduce an onset time of melting consistent with fast camera data and final sample conditions, within < 200 ms. Maximum surface temperatures of 3122 K and 2787 K are estimated for the samples farthest away from the strike point, while the closest samples achieve melting at 4067 ms and 4750 ms into the ~5000 ms plasma exposure. A +10% increase in both the SMITER 𝑞⊥,𝑖nter−𝐸LM calculations and the estimated ELM heat loads 𝑞⊥, 𝐸LM was required to achieve this result, which is within the uncertainty of the diagnostic data but likely accounts for non-ideal geometry effects plus other physics uncertainties not included in this first iteration of modeling. This work provided valuable estimates of the 3D temperature evolution to help better understand the observed surface morphology and internal recrystallization of samples, which are discussed in detail in a complementary manuscript [1]. Benchmarking efforts with more diagnosed DIII-D experiments are underway to further refine the SMITER and SIERRA models for DiMES. Future use of these tools will enable researchers to precisely target heat flux exposure conditions in DIII-D to test, but not exceed, the thermomechanical limitations of novel plasma-facing materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of raised inner strike point equilibria scenario in ITER for detritiation from beryllium co-deposits

Abstract In ITER, tritium retention primarily occurs through co-deposition with beryllium. To avoid exceeding the strict tritium inventory limit, efficient tritium recovery techniques are essential. Baking is the ITER baseline for tritium recovery, but its effectiveness in removing tritium from thick beryllium layers is limited. A raised strike point scenario is considered an alternative method for removing tritium from the ITER inner vertical divertor target by heating components via plasma flux. This paper presents SOLPS-ITER code simulations conducted under various conditions, assessing the divertor performance and tritium outgassing of the raised strike point scenario. As the strike point is raised, recycled neutrals are not efficiently baffled by the dome and scrape-off layer, significantly changing the neutral trajectory and ionization source distribution. This improves detachment accessibility but worsens core-edge compatibility compared to the baseline scenario. However, in the partially detached condition, the impact of raising the strike point, perpendicular transport, and q 95 on target heat flux is not significant, as it primarily scales with the input power. Target heat flux is translated to target surface temperature using a simplified heat transfer model that considers the 3D target monoblock geometry and active cooling condition, excluding Be layer thermal properties. For partially detached divertor conditions, the bulk tungsten monoblock surface temperature remains below the baking temperature, which is insufficient for efficient tritium outgassing under the actively cooled ITER divertor condition. However, considering the potential thermal contact resistance between the beryllium and tungsten layers, which may significantly impact temperature distribution, the temperature of the beryllium layer can be raised to a level sufficient for efficient tritium outgassing. Therefore, the raised strike point scenario can be considered as an alternative in-vessel tritium removal technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗