Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Recent Advances in Soft Matter Characterization Capabilities Developed at NASA GRC

In 1991, famous French scientist Pierre-Gilles de Genes was awarded Nobel prize for his impactful research in soft matter, more specifically polymers. He is defined as the founding father of soft matter. In his Nobel lecture (https://www.nobelprize.org/uploads/2018/06/gennes-lecture.pdf ) he described soft matter aka complex fluids as materials with two primary features – (a) complexity and (b) flexibility. The sub-categories of soft matter (e.g.- granular materials, polymers, foams, colloids etc.) are defined on the basis of Pierre-Gilles de Gennes’ definition. At NASA GRC, we are pushing the boundaries for fundamental study of soft matter on Lunar Surface. With regard to Lunar surface science, we are focusing on developing capabilities pertaining to granular materials and bio-soft/active matter to facilitate future efforts in ISRU and bio-ISRU capabilities. In order to achieve fundamental goals of soft matter research within the limitations of Lunar environment, the scientific capabilities need to be small, flexible, modular, off the shelf and the focus needs to be more on developing an interdisciplinary capability that leverages the recent growth in AI/ML and Computer Vision to augment our understanding of fundamental science. This strategy would allow us to reduce our resource requirement during launch, installation, and occupied real estate footprint on Lunar surface In this talk, we will go over 3 different capabilities that we have developed in house and in close collaboration – (a) Differential Dynamic Microscopy (DDM), (b) Portable In-situ Chemical Spectroscopy (PICS) and (c) Computer Vision Enabled Observation. At very high level, Differential Dynamic Microscopy (DDM) allows us to study the structure-property-process relation (microrheology) of bio-soft/active matter using optical microscope and improved image analysis capabilities. PICS uses AI/ML-based advanced signal deconvolution and analysis technique that can work with existing portable spectroscopy tools to perform materials analysis (e.g.- granular materials and bio-soft/active matter) inspection on the go. Finally, computer vision enabled analysis allows us to use simple camera images for 3D reconstruction of experimental process and tracking of objects of interest in an experiment. We expect that this detailed process will allow us reach a thorough understanding of soft matter in Lunar environment. The capabilities developed by us will help to validate and establish fundamental understanding in Lunar environment. This will, in turn, allow us to guide future space exploration missions and expand the knowledge base of the scientific and engineering communities.

Suman Sinha Ray↗

Skin Friction Measurement on a Swept NACA 0015 Wing Using Oil Film Interferometry

An application of oil film interferometry (OFI) to measure skin friction on the 3D flow over an NACA 0015 airfoil with 30° of sweep is presented. Local flow direction must be known to apply OFI to complex 3D flows such as this. A recently developed surface flow vector extraction method was integrated into the OFI analysis algorithm. Surface flow vectors were used to calculate the surface streamlines and hence provided local flow direction to the OFI analysis. After calibration using photogrammetry, the surface flow vectors also enabled decomposition of the skin friction coefficient into different components (such as chordwise and spanwise). The presented method successfully measured skin friction at locations with different flow characteristics such as high skin friction regions, strong spanwise flow regions, and 3D flow separated regions. In the current OFI analysis, multiple interferogram images acquired at different times were analyzed for the same location. The multiple interferogram analysis enabled averaging, which reduced the scatter the skin friction data. The results presented herein demonstrate the capability of the current approach, thereby extending OFI skin friction measurements to complex 3D flows.

Skin friction measurement↗

Skin Friction Measurement on a Swept NACA 0015 Wing Using Oil Film Interferometry

An application of oil film interferometry (OFI) to measure skin friction on the 3D flow over an NACA 0015 airfoil with 30° of sweep is presented. Local flow direction must be known to apply OFI to complex 3D flows such as this. A recently developed surface flow vector extraction method was integrated into the OFI analysis algorithm. Surface flow vectors were used to calculate the surface streamlines and hence provided local flow direction to the OFI analysis. After calibration using photogrammetry, the surface flow vectors also enabled decomposition of the skin friction coefficient into different components (such as chordwise and spanwise). The presented method successfully measured skin friction at locations with different flow characteristics such as high skin friction regions, strong spanwise flow regions, and 3D flow separated regions. In the current OFI analysis, multiple interferogram images acquired at different times were analyzed for the same location. The multiple interferogram analysis enabled averaging, which reduced the scatter the skin friction data. The results presented herein demonstrate the capability of the current approach, thereby extending OFI skin friction measurements to complex 3D flows.

Skin friction measurement↗

Optical Navigation for Autonomous Approach of Small Unknown Bodies

State of the practice in navigation around small celestial bodies heavily relies on ground sup- port and human skill, in particular, for perception-based operations such as optical navigation and mapping. This leads to longer duration and more complex mission operations and sub- sequently higher cost. Furthermore, it imposes limitations for certain missions such as fast fly-bys or multi-agent operations. In this work, we present an autonomous navigation strat- egy suitable for approaching small unexplored bodies. During the approach, we estimate the body’s physical properties as well as the spacecraft’s relative trajectory and associated un- certainties. The autonomous navigation strategy, which is solely based on optical measure- ments, begins as soon as the body becomes resolved in the navigation camera and terminates at the start of proximity operations, when the spacecraft makes its first trajectory correction to stay in the vicinity of the body. Our strategy uses multiple image-processing algorithms: light-curve analysis for estimating the target body’s rotation rate, Shape-from-Silhouette for reconstructing the 3D shape and estimating its rotation pole, and feature tracking tailored to Small-Body images for estimating relative navigation parameters. We used the Mission Analysis, Operations, and Navigation Toolkit Environment (MONTE) developed by the Jet Propulsion Laboratory to evaluate the feasibility of this multi-phase navigation strategy using simulated images of an approach trajectory. We used the Rosetta mission data to generate photorealistic images to characterise the performance of this approach. This work is based on the assumptions that the spacecraft attitude is known, the body is a principal-axis rotator, a-priori estimates of ephemerides and scale are available, and the body is observed from a zero sun phase only during initial approach. Preliminary results show orbit determination performance that is on par with the human navigation from the Rosetta mission; albeit with a 1% bias in spacecraft-target radial distance estimate. The bias error is likely due to the robustness and accuracy of the visual tracking under dynamic lighting conditions and per- spective changes, which decrease accuracy.

Villa, Jacopo↗

A Flexible Method for Producing F.E.M. Analysis of Bone Using Open-Source Software

This project, performed in support of the NASA GRC Space Academy summer program, sought to develop an open-source workflow methodology that segmented medical image data, created a 3D model from the segmented data, and prepared the model for finite-element analysis. In an initial step, a technological survey evaluated the performance of various existing open-source software that claim to perform these tasks. However, the survey concluded that no single software exhibited the wide array of functionality required for the potential NASA application in the area of bone, muscle and bio fluidic studies. As a result, development of a series of Python scripts provided the bridging mechanism to address the shortcomings of the available open source tools. The implementation of the VTK library provided the most quick and effective means of segmenting regions of interest from the medical images; it allowed for the export of a 3D model by using the marching cubes algorithm to build a surface mesh. To facilitate the development of the model domain from this extracted information required a surface mesh to be processed in the open-source software packages Blender and Gmsh. The Preview program of the FEBio suite proved to be sufficient for volume filling the model with an unstructured mesh and preparing boundaries specifications for finite element analysis. To fully allow FEM modeling, an in house developed Python script allowed assignment of material properties on an element by element basis by performing a weighted interpolation of voxel intensity of the parent medical image correlated to published information of image intensity to material properties, such as ash density. A graphical user interface combined the Python scripts and other software into a user friendly interface. The work using Python scripts provides a potential alternative to expensive commercial software and inadequate, limited open-source freeware programs for the creation of 3D computational models. More work will be needed to validate this approach in creating finite-element models.

gravitational physiology↗

Accurate estimation of object location in an image sequence using helicopter flight data

In autonomous navigation, it is essential to obtain a three-dimensional (3D) description of the static environment in which the vehicle is traveling. For a rotorcraft conducting low-latitude flight, this description is particularly useful for obstacle detection and avoidance. In this paper, we address the problem of 3D position estimation for static objects from a monocular sequence of images captured from a low-latitude flying helicopter. Since the environment is static, it is well known that the optical flow in the image will produce a radiating pattern from the focus of expansion. We propose a motion analysis system which utilizes the epipolar constraint to accurately estimate 3D positions of scene objects in a real world image sequence taken from a low-altitude flying helicopter. Results show that this approach gives good estimates of object positions near the rotorcraft's intended flight-path.

Tang, Yuan-Liang↗

Tomography Analysis of Orion Artemis 1 Heatshield Sample

The Orion spacecraft, under NASA's Artemis program, is an integral step in humanity's ambitions of deep space exploration, including our return to the Moon and subsequent mission to Mars. The performance of Orion's heatshield is central to ensuring the safety and success of such missions. This presentation offers a comprehensive overview of the process used in and findings derived from tomography scans of an Artemis 1 heatshield sample executed at the Lawrence Berkeley National Laboratory's Advanced Light Source. These tomography scans captured high-resolution X-Ray images of the heatshield's microstructure, allowing advanced imaging to be employed for 3D image segmentation and visualization of the sample. The Porous Media Analysis (PuMA) software stands central to our analysis, offering robust computational algorithms and methodologies to digitally compute properties of the heatshield material. The presentation discusses the following derived metrics: - Volume fractions, representing the spatial distribution and amounts of various components throughout the heatshield’s depth. - Porosity and crack distributions, offering insights into the void space within the material, critical for understanding the heatshield's structural integrity. - Fiber orientation, detailing the alignment and arrangement of fibers, significant for material orthotropy. - Permeability estimates, quantifying the passage of gas through the material, relevant for re-entry conditions and pyrolysis gasses. One distinctive feature of this study is the comparative evaluation against data obtained from tomography scans of the Exploration Flight Test-1 (EFT-1) heatshield. Such a comparison offers multiple insights, including evaluation of the consistency and repeatability of manufacturing processes as well as understanding of any evolutionary changes in heatshield design or material properties.

Micro-tomography↗

Applications of Automation Methods for Nonlinear Fracture Test Analysis

Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

Allen, Phillip A.↗

Lunar and Planetary Science XXXV: Astrobiology

The presentations in this session are: 1. A Prototype Life Detection Chip 2. The Geology of Atlantis Basin, Mars, and Its Astrobiological Interest 3. Collecting Bacteria Together with Aerosols in the Martian Atmosphere by the FOELDIX Experimental Instrument Developed with a Nutrient Detector Pattern: Model Measurements of Effectivity 4. 2D and 3D X-ray Imaging of Microorganisms in Meteorites Using Complexity Analysis to Distinguish Field Images of Stromatoloids from Surrounding Rock Matrix in 3.45 Ga Strelley Pool Chert, Western Australia 4. Characterization of Two Isolates from Andean Lakes in Bolivia Short Time Scale Evolution of Microbiolites in Rapidly Receding Altiplanic Lakes: Learning How to Recognize Changing Signatures of Life 5. The Effect of Salts on Electrospray Ionization of Amino Acids in the Negative Mode 6. Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence 7. Microbial D/H Fractionation in Extraterrestrial Materials: Application to Micrometeorites and Mars 8. Carbon Isotope Characteristics of Spring-fed Iron-precipitating Microbial Mats 9. Amino Acid Survival Under Ambient Martian Surface UV Lighting Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions 10. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods 11. Thermal Decomposition of Siderite-Pyrite Assemblages: Implications for Sulfide Mineralogy in Martian Meteorite ALH84001 Carbonate Globules 12. Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy 13. On the Possibility of a Crypto-Biotic Crust on Mars Based on Northern and Southern Ringed Polar Dune Spots 14. Comparative Planetology of the Terrestrial Inner Planets: Implications for Astrobiology 15. A Possible Europa Exobiology 16. A Possible Biogeochemical Model for Titan

Source record↗

Physiological and Molecular Changes in Various Biological Organisms Cultured under Simulated Microgravity Conditions

Microgravity is one of the most import factors in space flight where its impact on living biological organisms is concerned. Many different ailments have been reported in astronauts such as spaceflight related osteopenia, cardiovascular concerns, and loss of eye sight. In order to understand why µg causes these issues we must understand what is happening at the most basic of biological structures, the cell. The work done in this report is a culmination of contributions made to a much larger project. The project seeks to understand how cellular physiology is changing in SMG conditions and use this knowledge to feed into a follow-up study on the genetic changes that are seen in SMG environments. Cells were imaged using confocal microscopy after 20hrs and 48hrs in a 3D clinostat called the Gravite. Lengths, widths, heights, and total cell areas were measured using an image analysis software package ImageJ. There were significant differences in lengths and widths of cell nuclei, and total area of cell coverage. The report then discusses some of the problems with the testing apparatus and how 3D printing technology may be used to create better sample holders for the 3D clinostat.

cell biology↗

Coronal Polarization of Pseudostreamers and the Solar Polar Field Reversal

The reversal of the solar polar magnetic field is notoriously hard to pin down due to the extreme viewing angle of the pole. In Cycle 24, the southern polar field reversal can be pinpointed with high accuracy due to a large-scale pseudostreamer that formed over the pole and persisted for approximately a year. We tracked the size and shape of this structure with multiple observations and analysis techniques including PROBA2/SWAP EUV images, AIA EUV images, CoMP polarization data, and 3D tomographic reconstructions. We find that the heliospheric field reversed polarity in February 2014, whereas in the photosphere, the last vestiges of the previous polar field polarity remained until March 2015. We present here the evolution of the structure and describe its identification in the Fe XII 1074nm coronal emission line, sensitive to the Hanle effect in the corona.

magnetic field↗

Tracking Nonradial Outflows in Extreme Ultraviolet and White Light Solar Images

Understanding the solar corona requires knowledge of its dynamics through its various layers and subsequent connectivity to the heliosphere. This requires understanding the nature of the outflows and the physical transitions through the middle corona (∼1.5–6.0 Rs). While this region is still inaccessible to in situ measurements, remote sensing observations are available, but their interpretation can be controversial due to line-of-sight effects and the nonradial motion of outflowing structures close to the Sun (≤3.0 Rs). In this work, we describe a method to mitigate these challenges by generating nonradial height–time profiles of outflows by using advanced image processing techniques. The northern and southern boundaries of a large equatorial streamer during the 2008 solar minimum were identified in STEREO/SECCHI solar images, using two different methodologies based on thresholds of brightness and piecewise polynomial function fitting. To address line-of-sight issues, we used tomographic reconstruction of the 3D distribution of the coronal electron density based on SECCHI/COR2 images. Spectral analysis of the time series of the position angle of the streamer boundary revealed its oscillatory nature at some heights at 36–48 and 10.5–14.6 hr. Dividing the distance between the northern and southern streamer boundaries in equal parts at each height, we obtained nonradial height–time paths from which we generated nonradial profiles of corona/solar wind plasma outflow. We tracked outflows as they moved uninterruptedly from the Sun in EUVI, through COR1 and into COR2. Finally, we discuss the preliminary results of nonradial plane-of-sky velocities for a coronal mass ejection and two small-scale features.

Nathalia Alzate↗

An interactive system for analysis of global cloud imagery

Synoptic images of the global cloud pattern composited from six contemporaneous satellites provide an unprecedented view of the global cloud field. Having horizontal resolution of about 0.5 deg and temporal resolution of 3 h, the global cloud imagery (GCI) resolves most of the variability of organized convection, including several harmonics of the diurnal cycle. Although the GCI has these attractive features, the dense and 3D nature of that data make it a formidable volume of information to treat in a practical and efficient manner. An interactive image-analysis system (IAS) has been developed to investigate the space-time variability of global cloud behavior. In the IAS, data, hardware, and software are integrated into a single system providing a variety of space-time covariance analyses in a menu-driven format. Owing to its customized architecture and certain homogeneous properties of the GCI, the IAS calculates such quantities effectively. Many covariance statistics are derived from 3D data with interactive speed, allowing the user to interrogate the archive iteratively in a single session. The 3D nature of those analyses and the speed with which they are performed distinguish the IAS from conventional image processing of 2D data.

Woodberry, Karen↗

User Directed Tools for Exploiting Expert Knowledge in an Immersive Segmentation and Visualization Environment

Volumetric data sets have become common in medicine and many sciences through technologies such as computed x-ray tomography (CT), magnetic resonance (MR), positron emission tomography (PET), confocal microscopy and 3D ultrasound. When presented with 2D images humans immediately and unconsciously begin a visual analysis of the scene. The viewer surveys the scene identifying significant landmarks and building an internal mental model of presented information. The identification of features is strongly influenced by the viewers expectations based upon their expert knowledge of what the image should contain. While not a conscious activity, the viewer makes a series of choices about how to interpret the scene. These choices occur in parallel with viewing the scene and effectively change the way the viewer sees the image. It is this interaction of viewing and choice which is the basis of many familiar visual illusions. This is especially important in the interpretation of medical images where it is the expert knowledge of the radiologist which interprets the image. For 3D data sets this interaction of view and choice is frustrated because choices must precede the visualization of the data set. It is not possible to visualize the data set with out making some initial choices which determine how the volume of data is presented to the eye. These choices include, view point orientation, region identification, color and opacity assignments. Further compounding the problem is the fact that these visualization choices are defined in terms of computer graphics as opposed to language of the experts knowledge. The long term goal of this project is to develop an environment where the user can interact with volumetric data sets using tools which promote the utilization of expert knowledge by incorporating visualization and choice into a tight computational loop. The tools will support activities involving the segmentation of structures, construction of surface meshes and local filtering of the data set. To conform to this environment tools should have several key attributes. First, they should be only rely on computations over a local neighborhood of the probe position. Second, they should operate iteratively over time converging towards a limit behavior. Third, they should adapt to user input modifying they operational parameters with time.

Senger, Steven O.↗

Computer Tomography Analysis of Fastrac Composite Thrust Chamber Assemblies

Computed tomography (CT) inspection has been integrated into the production process for NASA's Fastrac composite thrust chamber assemblies (TCAs). CT has been proven to be uniquely qualified to detect the known critical flaw for these nozzles, liner cracks that are adjacent to debonds between the liner and overwrap. CT is also being used as a process monitoring tool through analysis of low density indications in the nozzle overwraps. 3d reconstruction of CT images to produce models of flawed areas is being used to give program engineers better insight into the location and nature of nozzle flaws.

Beshears, Ronald D.↗

Analysis of "Stone" Samples from C-Type Asteroid Ryugu

As a part of activities of initial analysis, we analyzed eighteen Ryugu “stone” samples of 1 ~ 8mm in size: seven stones from the 1st touch down site and eleven from the 2nd touch down site. Ryugu stones were analyzed first using X-rays, UV, visible, near-infrared, mid-infrared, and muon probes for surface reflectance spectra, internal 3D structure and element distribution, crystal structures, and bulk composition of light elements such as C, N, and O. Measurements for magnetic, thermal, and physical properties using some stones were also performed. TOF-SIMS analysis of fluid inclusions as being continued. Small particles separated from some stones were analyzed by IR-CT. Based on 3D-CT images of individual stones, objects of interests were identified, separated by pFIB cutting, and exposed by polishing on the surface of epoxy disks. FE-EPMA/FE-SEM analysis was made on ~40 polished epoxy disks for chemical composition and textural observation. FIB sections and small (~15 μm in size) fragments were separated from polished surface and analyzed by TEM, STXM,XRF, and nano-CT.

T. Nakamura↗

Rendering Three-Dimensional Solar Coronal Structures

An X-ray or EUV image of the corona or chromosphere is a 2D representation of an extended 3D complex for which a general inversion process is impossible. A specific model must be incorporated in order to understand the full 3D structure. We approach this problem by modeling a set of optically-thin 3D plasma flux tubes which we render these as synthetic images. The resulting images allow the interpretation of the X-ray/EUV observations to obtain information on (1) the 3D structure of X-ray images, i.e., the geometric structure of the flux tubes, and on (2) the internal structure using specific plasma characteristics, i.e., the physical structure of the flux tubes. The data-analysis technique uses magnetograms to characterize photospheric magnetic fields and extrapolation techniques to form the field lines. Using a new set of software tools, we have generated 3D flux tube structures around these field lines and integrated the plasma emission along the line of sight to obtain a rendered image. A set of individual flux-tube images is selected by a non-negative least-squares technique to Provide a match with an observed X-ray image. The scheme minimizes the squares of the differences between the synthesized image and the observed image with a non-negative constraint on the coefficients of the brightness of the individual flux-tube loops. The derived images are used to determine the specific photospheric foot points and physical data, i.e., scaling laws for densities and loop lengths. The development has led to Computer efficient integration and display software that is compatible for comparison with observations (e.g., Yohkoh SXT data, NIXT, or EIT). This analysis is important in determining directly the magnetic field configuration, which provides the structure of coronal loops, and indirectly the electric currents or waves, which provide the energy for the heating of the plasma. We have used very simple assumptions (i.e., potential magnetic fields and isothermal corona) to provide an initial test of the techniques before complex models are introduced. We have separated the physical and geometric contributions of the emission for a set of flux tubes and concentrated, in this initial study, on the geometric contributions by making approximations to the physical contributions. The initial results are consistent with the scaling laws derived from Yohkoh SXT data.

Gary, G. Allen↗

Imagery Integration Team

The Human Exploration Science Office (KX) provides leadership for NASA's Imagery Integration (Integration 2) Team, an affiliation of experts in the use of engineering-class imagery intended to monitor the performance of launch vehicles and crewed spacecraft in flight. Typical engineering imagery assessments include studying and characterizing the liftoff and ascent debris environments; launch vehicle and propulsion element performance; in-flight activities; and entry, landing, and recovery operations. Integration 2 support has been provided not only for U.S. Government spaceflight (e.g., Space Shuttle, Ares I-X) but also for commercial launch providers, such as Space Exploration Technologies Corporation (SpaceX) and Orbital Sciences Corporation, servicing the International Space Station. The NASA Integration 2 Team is composed of imagery integration specialists from JSC, the Marshall Space Flight Center (MSFC), and the Kennedy Space Center (KSC), who have access to a vast pool of experience and capabilities related to program integration, deployment and management of imagery assets, imagery data management, and photogrammetric analysis. The Integration 2 team is currently providing integration services to commercial demonstration flights, Exploration Flight Test-1 (EFT-1), and the Space Launch System (SLS)-based Exploration Missions (EM)-1 and EM-2. EM-2 will be the first attempt to fly a piloted mission with the Orion spacecraft. The Integration 2 Team provides the customer (both commercial and Government) with access to a wide array of imagery options - ground-based, airborne, seaborne, or vehicle-based - that are available through the Government and commercial vendors. The team guides the customer in assembling the appropriate complement of imagery acquisition assets at the customer's facilities, minimizing costs associated with market research and the risk of purchasing inadequate assets. The NASA Integration 2 capability simplifies the process of securing one-of-a-kind imagery assets and skill sets, such as ground-based fixed and tracking cameras, crew-in the-loop imaging applications, and the integration of custom or commercial-off-the-shelf sensors onboard spacecraft. For spaceflight applications, the Integration 2 Team leverages modeling, analytical, and scientific resources along with decades of experience and lessons learned to assist the customer in optimizing engineering imagery acquisition and management schemes for any phase of flight - launch, ascent, on-orbit, descent, and landing. The Integration 2 Team guides the customer in using NASA's world-class imagery analysis teams, which specialize in overcoming inherent challenges associated with spaceflight imagery sets. Precision motion tracking, two-dimensional (2D) and three-dimensional (3D) photogrammetry, image stabilization, 3D modeling of imagery data, lighting assessment, and vehicle fiducial marking assessments are available. During a mission or test, the Integration 2 Team provides oversight of imagery operations to verify fulfillment of imagery requirements. The team oversees the collection, screening, and analysis of imagery to build a set of imagery findings. It integrates and corroborates the imagery findings with other mission data sets, generating executive summaries to support time-critical mission decisions.

Calhoun, Tracy↗