Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from weakly interacting massive particle (WIMP) dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C3F8 scale in accordance with a new nucleation mechanism, rather than one driven by a hot spike as previously supposed. Using this semiempirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c-2 and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c-2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design methodology: edgeless 3D ASICs with complex in-pixel processing for pixel detectors

The design methodology for the development of 3D integrated edgeless pixel detectors with in-pixel processing using Electronic Design Automation (EDA) tools is presented. A large area 3 tier 3D detector with one sensor layer and two ASIC layers containing one analog and one digital tier, is built for x-ray photon time of arrival measurement and imaging. A full custom analog pixel is 65μm x 65μm. It is connected to a sensor pixel of the same size on one side, and on the other side it has approximately 40 connections to the digital pixel. A 32 x 32 edgeless array without any peripheral functional blocks constitutes a sub-chip. The sub-chip is an indivisible unit, which is further arranged in a 6 x 6 array to create the entire 1.248cm x 1.248cm ASIC. Each chip has 720 bump-bond I/O connections, on the back of the digital tier to the ceramic PCB. All the analog tier power and biasing is conveyed through the digital tier from the PCB. The assembly has no peripheral functional blocks, and hence the active area extends to the edge of the detector. This was achieved by using a few flavors of almost identical analog pixels (minimal variation in layout) to allow for peripheral biasing blocks to be placed within pixels. The 1024 pixels within a digital sub-chip array have a variety of full custom, semi-custom and automated timing driven functional blocks placed together. The methodology uses a modified mixed-mode on-top digital implementation flow to not only harness the tool efficiency for timing and floor-planning but also to maintain designer control over compact parasitically aware layout. The methodology uses the Cadence design platform, however it is not limited to this tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-561: Energy Dependence of a Scintillation Detector

Purpose: To investigate the response and dose rate dependence of a scintillation detector over a wide energy range. Methods: The energy dependence of W1 scintillation detector was tested with: 1) 50–225 keV beams generated by an animal irradiator, 2) a Leksell Gamma Knife Perfexion Co-60 source, 3) 6MV, 6FFF, 10FFF and 15MV photon beams, and 4) 6–20MeV electron beams from a linac. Calibrated linac beams were used to deliver 100 cGy to the detector at dmax in water under reference conditions. The gamma-knife measurement was performed in solid water (100 cGy with 16mm collimator). The low energy beams were calibrated with an ion chamber in air (TG-61), and the scintillation detector was placed at the same location as the ionization chamber during calibration. For the linac photon and electron beams, dose rate dependence was tested for 100–2400 and 100–800 MU/min. Results: The scintillation detector demonstrated strong energy dependence in the range of 50–225keV. The measured values were lower than the delivered dose and increased as the energy increased. Therapeutic photon beams showed energy independence with variations less than 1%. Therapeutic electron beams displayed the same sensitivity of ∼2–3% at their corresponding dmax depths. The change in dose-rate of photon and electron beams within the therapeutic energy range did not affect detector output (<0.5%). Measurements acquired with the gamma knife showed that the output data agreed with the delivered dose up to 3%. Conclusion: W1 scintillation detector output has a strong energy dependence in the diagnostic and orthovoltage energy range. Therapeutic photon beams exhibited energy independence with no observable dose-rate dependence. This study may aid in the implementation of a scintillation detector in QA programs by providing energy calibration factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Muon Range Detector at SciBooNE

SciBooNE is a new neutrino experiment at Fermilab. The detector will undertake a number of measurements, principally sub-GeV neutrino cross-section measurements applicable to T2K. The detector consists of 3 sub-detectors; SciBar and the Electron-Catcher were both used in the K2K experiment at KEK, Japan, whilst the Muon Range Detector is a new detector constructed at Fermilab using recycled materials from previous Fermilab experiments. A description of the detector, its construction and software is presented here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sci—Fri PM: Dosimetry—05: Megavoltage electron backscatter: EGSnrc results versus 21 experiments

The accuracy of electron backscatter calculations at megavoltage energies is important for many medical physics applications. In this study, EGSnrc calculations of megavoltage electron backscatter (1–22 MeV) are performed and compared to the data from 21 experiments published between 1954 and 1993 for 25 single elements with atomic numbers from 3 to 92. Typical experimental uncertainties are 15%. For EGSnrc simulations, an ideal detector is assumed, and the most accurate electron physics options are employed, for a combined statistical and systematic uncertainty of 3%. The quantities compared are the backscatter coefficient and the energy spectra (in the backward hemisphere and at specific detector locations). For the backscatter coefficient, the overall agreement is within ±2% in the absolute value of the backscatter coefficient (in per cent), and within 11% of the individual backscatter values. EGSnrc results are systematically on the higher end of the spread of the experimental data, which could be partially from systematic experimental errors discussed in the literature. For the energy spectra, reasonable agreement between simulations and experiments is observed, although there are significant variations in the experimental data. At the lower end of the spectra, simulations are higher than some experimental data, which could be due to reduced experimental sensitivity to lower energy electrons and/or over-estimation by EGSnrc for backscattered secondary electrons. In conclusion, overall good agreement is observed between EGSnrc backscatter calculations and experimental measurements for megavoltage electrons. There is a need for high quality experimental data for the energy spectra of backscattered electrons.

60 APPLIED LIFE SCIENCES↗

Electron Velocity Moments in the Solar Wind. I. Calibration of the Wind 3DP EESA Low Detector

Calibrated measurements of electron velocity distribution functions (VDFs) are necessary to characterize fluid and kinetic processes in weakly collisional and nearly collisionless plasmas such as the solar wind. Therefore, we analyzed 3,996,051 electron VDFs observed by the Wind 3DP thermal electron detector near 1 astronomical unit (au) between January 1, 2005 and November 25, 2017. The data were calibrated for each electron VDF to produce accurate velocity moments in the solar wind. This is the first full solar cycle coverage electron velocity moment dataset in the near-Earth solar wind. Herein (Paper I) we discuss the calibration process/algorithms and the velocity moment constraints, uncertainties, and resulting public dataset. In the second paper (Paper II), we statistically analyze the electron velocity moment dataset.

plasmas↗

Investigating fusion plasma instabilities in the Mega Amp Spherical Tokamak using mega electron volt proton emissions (invited)

The proton detector (PD) measures 3 MeV proton yield distributions from deuterium-deuterium fusion reactions within the Mega Amp Spherical Tokamak (MAST). The PD’s compact four-channel system of collimated and individually oriented silicon detectors probes different regions of the plasma, detecting protons (with gyro radii large enough to be unconfined) leaving the plasma on curved trajectories during neutral beam injection. From first PD data obtained during plasma operation in 2013, proton production rates (up to several hundred kHz and 1 ms time resolution) during sawtooth events were compared to the corresponding MAST neutron camera data. Fitted proton emission profiles in the poloidal plane demonstrate the capabilities of this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Definition phase study of the grand tour missions

The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.

Simpson, J. A.↗

Development of a Telescope for Medium-Energy Gamma-ray Astronomy

Since the launch of AGILE and FERMI, the scientific progress in high-energy (Eg greater than approximately 200 MeV) gamma-ray science has been, and will continue to be dramatic. Both of these telescopes cover a broad energy range from approximately 20 MeV to greater than 10 GeV. However, neither instrument is optimized for observations below approximately 200 MeV where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. Hence, while significant progress from current observations is expected, there will nonetheless remain a significant sensitivity gap in the medium-energy (approximately 0.1-200 MeV) regime; the lower end of this range remains largely unexplored whereas the upper end will allow comparison with FERMI data. Tapping into this unexplored regime requires significant improvements in sensitivity. A major emphasis of modern detector development, with the goal of providing significant improvements in sensitivity in the medium-energy regime, focuses on high-resolution electron tracking. The Three-Dimensional Track Imager (3-DTI) technology being developed at GSFC provides high resolution tracking of the electron-positron pair from gamma-ray interactions from 5 to 200 MeV. The 3-DTI consists of a time projection chamber (TPC) and 2-D cross-strip microwell detector (MWD). The low-density and homogeneous design of the 3-DTI, offers unprecedented sensitivity by providing angular resolution near the kinematic limit. Electron tracking also enables measurement of gamma-ray polarization, a new tool to study astrophysical phenomenon. We describe the design, fabrication, and performance of a 30x30x30 cm3 3-DTI detector prototype of a medium-energy gamma-ray telescope.

Sunter, Stan↗

Development of a Telescope for Medium-Energy Gamma-Ray Astronomy

Since the launch of AGILE and FERMI, the scientific progress in high-energy (E(sub gamma) greater than approximately 200 MeV) gamma-ray science has been, and will continue to be dramatic. Both of these telescopes cover a broad energy range from approximately 20 MeV to greater than 10 GeV. However, neither instrument is optimized for observations below approximately 200 MeV where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. Hence, while significant progress from current observations is expected, there will nonetheless remain a significant sensitivity gap in the medium-energy (approximately 0.1-200 MeV) regime; the lower end of this range remains largely unexplored whereas the upper end will allow comparison with FERMI data. Tapping into this unexplored regime requires significant improvements in sensitivity. A major emphasis of modern detector development, with the goal of providing significant improvements in sensitivity in the medium-energy regime, focuses on high-resolution electron tracking. The Three-Dimensional Track Imager (3-DTI) technology being developed at GSFC provides high resolution tracking of the electron-positron pair from gamma-ray interactions from 5 to 200 MeV. The 3-DTI consists of a time projection chamber (TPC) and 2-D cross-strip microwell detector (MWD). The low-density and homogeneous design of the 3-DTI, offers unprecedented sensitivity by providing angular resolution near the kinematic limit. Electron tracking also enables measurement of gamma-ray polarization, a new tool to study astrophysical phenomenon. We describe the design, fabrication, and performance of a 30x30x30 cubic centimeters 3-DTI detector prototype of a medium-energy gamma-ray telescope.

Hunter, Stanley D.↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous investigation of parent electrons and bremsstrahlung X rays by rocket-borne detectors

Simultaneous measurements of the energy spectrum of precipitating electrons and the resulting bremsstrahlung X-ray spectrum were carried out during an auroral event on March 3, 1971, at the Churchill Research Range, Manitoba, Canada. The electron data were obtained with detectors on a Black Brant VB sounding rocket (275-km apogee), while the X-ray flux was measured by an instrument package that was boosted to 60 km on an Arcas rocket. The X-ray package was deployed on a parachute at apogee to provide a slow descent through the atmosphere. Thick-target bremsstrahlung theory is used to calculate the X-ray flux produced by the incident electrons, and a Monte Carlo method is used to predict the X-ray spectrum at various altitudes appropriate for comparison with the measured X-ray data. Satisfactory agreement between theory and experiment is obtained, and the value of the constant in the thick target theory has been estimated to be about 0.00002.

Vij, K. K.↗

Type 3 solar radio bursts

Using low frequency satellite observations, a direct comparison of the different theories is possible of the structure of the interplanetary medium. Measurements were made by satellite electron detectors in the same region of the interplanetary media where rapid drift type 3 solar radio bursts are generated. Results show, on the basis of this comparison, the general inadequacies of current type 3 burst theories and indicate a needed emphasis on formulating a new theory that is consistent with the low frequency observations. Representative observations from the RAE satellite are shown. The brightness temperature, which is a measure of the energy flux, versus frequency was plotted. Two events, a large burst and a large storm are also shown, each recorded at frequencies of 2.8 MHz and 700 KHz. High frequency curves obtained from ground-based observations are given.

Evans, L. G.↗

Intensity of primary cosmic-ray electrons of energy exceeding 8 GeV

Results are reported for measurement of the intensity and energy spectrum of primary cosmic-ray electrons with a spark-chamber-counter-emulsion detector flown at a mean altitude of 3 g/sq cm residual atmosphere. A least-squares fit to the flight data yields an electron spectrum from 8 to 80 GeV of approximately 93E to the -2.91 power electrons/sq m/sec per sr/GeV. The results are compared with those of previous experiments as well as with the spectrum obtained for galactic nonthermal radiation. It is concluded that a 'clumpy' magnetic field proportional to the square root of matter density is consistent with measurements of high-energy electrons and synchrotron radiation toward the center of the Galaxy, that a gradual steepening of the electron spectrum relative to the proton spectrum is consistent with an electron lifetime of 1 million years, and that the density of cosmic-ray nucleons and electrons should be essentially uniform throughout the Galaxy if the nucleons have the same lifetime as the electrons and if they traversed 4 to 5 g/sq cm in that lifetime.

Freier, P.↗

Integrated plan for LArTPC neutrino detectors in the US

We present an integrated R&D plan aimed at demonstrating the ability to build a very large Liquid Argon Time Projection Chamber (LArTPC), on a scale suitable for use as a Far Detector for the LBNE neutrino oscillation experiment. This plan adopts current LArTPC R&D-related activities and proposes new ones to address questions that go beyond those being answered by the current efforts. We have employed a risk evaluation strategy to identify questions that can be answered (or risks that can be mitigated) through one or more R&D steps. In summary form, the plan consists of the following pre-existing components: (1) The Materials Test Stand program, now in operation at Fermilab, addressing questions pertaining to maintenance of argon purity; (2) Existing electronics test stands at FNAL and BNL; (3) The Liquid Argon Purity Demonstrator (LAPD) now being assembled at Fermilab; (4) The ArgoNeuT prototype LArTPC, now running in the NuMI beam; (5) The MicroBooNE experiment, proposed as a physics experiment that will advance our understanding of the LArTPC technology, now completing its conceptual design phase; (6) A software development effort that is well integrated across present and planned LArTPC detectors. We are proposing to add to these efforts the following: (1) A membrane cryostat mechanical prototype to evaluate and gain expertise with this technology; (2) An installation and integration prototype, to understand issues pertaining to detector assembly, particularly in an underground environment; (3) A {approx} 5% scale electronics systems test to understand system-wide issues as well as individual component reliability. (4) A calibration test stand that would consist of a small TPC to be exposed to a test beam for calibration studies, relevant for evaluation of physics sensitivities. We have developed a timeline and milestones for achieving these goals as discussed in Section 4. The proposed activities necessary for the final design of LAr20 are complete by CD3 in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Point-spread functions for backscattered imaging in the scanning electron microscope

One knows the imaging system's properties are central to the correct interpretation of any image. In a scanning electron microscope regions of different composition generally interact in a highly nonlinear way during signal generation. Using Monte Carlo simulations we found that in resin-embedded, heavy metal-stained biological specimens staining is sufficiently dilute to allow an approximately linear treatment. We then mapped point-spread functions for backscattered-electron contrast, for primary energies of 3 and 7 keV and for different detector specifications. The point-spread functions are surprisingly well confined (both laterally and in depth) compared even to the distribution of only those scattered electrons that leave the sample again.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dopants, Isotope, Pressure and Lead Sequestration for Hybrid Perovskite Materials

Dopants, Isotope, Pressure and Lead Sequestration for Hybrid Perovskite Materials The soaring power conversion efficiency (PCE) of solution process-based organic-inorganic hybrid perovskites solar cells (PSCs) assures their membership in the competitive photovoltaic technologies. However, stability, toxicity and scalability are the three grand challenges that still impedes the market adoption of PSCs. Careful fundamental studies on how their fascinating optoelectronic properties is related to their structures may provide leads to these challenges and also spin off new applications. In this talk, I will present our recent study on the dopants, isotope and pressure effects on hybrid perovskite materials (HPMs). We discovered an interesting bipolar electron injection in LiCl-doped MAPbI 3 -based UV detectors that respond to the energy of UV photons in distinguished photocurrents polarity. We also investigated how the underline interaction between the mass of the cationic rotors and the inorganic lattice in HPMs by isotope effect. In-situ synchrotron X-ray and time-resolved photoluminescence revealed abnormal optoelectronic properties of HPMs by modulating their bond angles and bond lengths using high pressure techniques. Moreover, I will also discuss our new technology to sequestrate lead leakage on perovskite solar cells that can absorb >99% leaked Pb ions under severe device damge while without sacrificing the PCE under normal operational conditions.

Xu, Tao↗