Engineering PapersSearch

SEARCH · Engineering Papers

Results for “(LIT)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The JPL Hg(sup +) Extended Linear Ion Trap Frequency Standard: Status, Stability, and Accuracy Prospects

Microwave frequency standards based on room temperature (sup 199)Hg(sup +) ions in a Linear Ion Trap (LITS) presently achieve a Signal to Noise and line Q inferred short frequency stability. Long term stability has been measured for averaging intervals up to 5 months with apparent sensitivity to variations in ion number/temperature limiting the flicker floor.

Hg+ linear ion trap frequency LITE LITS microwave

Improved Linear Ion Trap Physics Package

This paper describes the improvement in the architecture of the physics package used in the Linear-Ion -Trap-(LIT)-based frequency standard recently developed at JPL.

Linear

HDBind: encoding of molecular structure with hyperdimensional binary representations

Traditional methods for identifying “hit” molecules from a large collection of potential drug-like candidates rely on biophysical theory to compute approximations to the Gibbs free energy of the binding interaction between the drug and its protein target. These approaches have a significant limitation in that they require exceptional computing capabilities for even relatively small collections of molecules. Increasingly large and complex state-of-the-art deep learning approaches have gained popularity with the promise to improve the productivity of drug design, notorious for its numerous failures. However, as deep learning models increase in their size and complexity, their acceleration at the hardware level becomes more challenging. Hyperdimensional Computing (HDC) has recently gained attention in the computer hardware community due to its algorithmic simplicity relative to deep learning approaches. The HDC learning paradigm, which represents data with high-dimension binary vectors, allows the use of low-precision binary vector arithmetic to create models of the data that can be learned without the need for the gradient-based optimization required in many conventional machine learning and deep learning methods. This algorithmic simplicity allows for acceleration in hardware that has been previously demonstrated in a range of application areas (computer vision, bioinformatics, mass spectrometery, remote sensing, edge devices, etc.). To the best of our knowledge, our work is the first to consider HDC for the task of fast and efficient screening of modern drug-like compound libraries. We also propose the first HDC graph-based encoding methods for molecular data, demonstrating consistent and substantial improvement over previous work. We compare our approaches to alternative approaches on the well-studied MoleculeNet dataset and the recently proposed LIT-PCBA dataset derived from high quality PubChem assays. We demonstrate our methods on multiple target hardware platforms, including Graphics Processing Units (GPUs) and Field Programmable Gate Arrays (FPGAs), showing at least an order of magnitude improvement in energy efficiency versus even our smallest neural network baseline model with a single hidden layer. Our work thus motivates further investigation into molecular representation learning to develop ultra-efficient pre-screening tools. We make our code publicly available at https://github.com/LLNL/hdbind.

59 BASIC BIOLOGICAL SCIENCES

Development and characterization of the flight model spectrometer onboard LuSEE-Night

The Lunar Surface Electromagnetics Experiment - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio-quiet far side of the Moon. Here, the LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA’s Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5-50MHz band. The flight model (FM) of the four-channel spectrometer has been developed. The FM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the FM meets all the requirements for LuSEE-Night.

47 OTHER INSTRUMENTATION

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Advanced Materials and Manufacturing Technologies Nondestructive Examination Efforts at Idaho National Laboratory: Report of FY-24 Efforts

This report details FY-24 nondestructive examination (NDE) efforts at Idaho National Laboratory (INL) in support of the Advanced Materials and Manufacturing Technologies (AMMT) program. While the goal of this endeavor is to develop a multi-modal, multi-length scale workflow for nondestructive characterization of advanced manufactured (AM) nuclear reactor components, substantial development remains until this is a reality. In support of this effort X-ray computed tomography (XCT), X-ray diffraction (XRD), neutron computed tomography (nCT), neutron diffraction, lock-in thermography (LIT), multi-point lock-in thermography (MLIT), and positron annihilation spectroscopy (PAS) were all used on AM specimens to examine defects such as voids, porosity, and residual stress. In addition to summarizing the results of these NDE applications, recommendations for integrating these into a more comprehensive undertaking to promote NDE of engineering-scale components are also included.

36 MATERIALS SCIENCE

On variable hydrostatic transmission for road vehicles, powered by supply of fluid at constant pressure

Various hydrostatic power transmission systems for automotive applications with power supply at constant pressure and unrestricted flow and with a Volvo Flygmotor variable displacement motor as the principal unit were investigated. Two most promising concepts were analyzed in detail and their main components optimized for minimum power loss at the EPA Urban Driving Cycle. The best fuel consumption is less than 10 lit. per 100 kM for a 1542 kG vehicle with a hydrostatic motor and a two speed gear box in series (braking power not recovered). Realistic system pressure affects the fuel consumption just slightly, but the package volume/weight drastically. Back pressure increases losses significantly. Special attention was paid to description of the behavior and modeling of the losses of variable displacement hydrostatic machines.

Magi, M.

High Reynolds number research - 1980

The fundamental aerodynamic questions for which high Reynolds number experimental capability is required were examined. Potential experiments which maximize the research returns from the use of the National Transonic Facility (NTF) were outlined. Calibration plans were reviewed and the following topics were discussed: fluid dynamics; high lit; configuration aerodynamics; aeroelasticity and unsteady aerodynamics; wind tunnel/flight correlation; space vehicles; and theoretical aerodynamics

Mckinney, L. W.

Veiling glare reduction methods compared for ophthalmic applications

Veiling glare in ocular viewing was simulated by viewing the retina of an eye model through a sheet of light-scattering material lit from the front. Four methods of glare reduction were compared, namely, optical scanning, polarized light, viewing and illumination paths either coaxial or intersecting at the object, and closed circuit TV. Photographs show the effect of these methods on visibility. Polarized light was required to eliminate light specularly reflected from the instrument optics. The greatest glare reduction was obtained when the first three methods were utilized together. Glare reduction using TV was limited by nonuniform distribution of scattered light over the image.

Buchele, D. R.

Heads up display

A heads up aircraft display which allows the pilot to view the display without diverting his attention from the scene ahead is disclosed. The display is designed for use on propeller driven aircraft comprised of a radially disposed row of lamps embedded in the rear surface of a propeller. Measurements of flight data are made by conventional means and converted into digital signals. These digital signals are applied to graphic generators which control lamp drivers which in turn control lamps through slip rings. The lamps are lit at the appropriate times during each revolution of the propeller to display the flight data in graphic form to the pilot. The combination of graphic generators and radially disposed lamps embedded in an aircraft propeller enables the pilot to view the display without diverting his attention from the scene ahead.

Garner, H. D.

Analyzing Microchips With Dark-Field Negative Photomicrography

Inverse development process yields fine details. Photomicrographic technique produces images of integrated-circuit chips. Technique based on dark-field illumination: (chip lit with bright central spot of light and photographed by light scattered or diffracted from spot. Reveals more about microstructure patterns related to photoresist masking than more conventional bright-field method.

Suszko, S. F.

Velocity-resolved observations of water in Comet Halley

High resolution (lambda/delta lambda approx. = 3 x 10 to the 5th power) near-infrared observations of H2O emission from Comet Halley were acquired at the time of maximum post-perihelion geocentric Doppler shift. The observed widths and absolute positions of the H2O line profiles reveal characteristics of the molecular velocity field in the coma. These results support H2O outflow from a Sun-lit hemisphere or the entire nucleus, but not from a single, narrow jet emanating from the nucleus. The measured pre- and post-perihelion outflow velocities were 0.9 + or - 0.2 and 1.4 + or - 0.2 km/s, respectively. Temporal variations in the kinematic properties of the outflow were inferred from changes in the spectral line shapes. These results are consistent with the release of H2O into the coma from multiple jets.

Larson, Harold P.

The engineering of the Voyager 2 mission to Uranus

The engineers of the Voyager 2 mission to Uranus had to deal with dwindling consumables, navigational challenges unique to the Uranian system, low light-level imaging, increasing communications problems, and failed equipment onboard the spacecraft, each of which could affect the success of the mission. The techniques for coping with each of these factors are discussed in detail. For instance, steadying of the spacecraft, achieved by cancelling the momentum change imparted to it by high-rate operations of the digital tape recorder, enhanced the data quality from several instruments, particularly the cameras. A careful power management scheme made it possible to conduct a successful radio occultation experiment which yielded detailed information on the Uranian atmospheric structure, including temperature and composition. A unique picture of the back-lit ring system was obtained.

Laeser, Richard P.

A reflection ansatz for surfaces with electrically small radii of curvature

Uniform reflection coefficients are developed for two- and three-dimensional, edge-like, perfectly conducting surfaces in the deep lit region. The uniformity is with respect to the electrical size of the radii of curvature at the surface's specular point. This uniformity allows one to physically interpret the reflected field from a smooth surface as one of the radii of curvature approaches zero as a diffracted field. The coefficients are heuristically generated from the exact scattered field for a two dimensional parabolic cylinder with plane wave illumination. The significant variables in this solution are the radii of curvature at the specular point and the distance between the specular point and the incident shadow boundaries in the principal planes. The field prediction accuracy of these reflection cofficients are critically examined through comparisons with reflected fields extracted from scattered fields of canonical surfaces.

Dominek, Allen K.

Effect of pituitary hollow fiber units and thyroid supplementation on growth in the little mouse (41949)

It is shown that the implantation of encapsulated pituitary cells into heterozygous lit/+ mice inhibited the average percentage change in weight gain as compared to controls. However, homozygous lit/lit mice receiving cell-filled capsules consistently had higher percentage weight gains than their control counterparts. It was also found that thyroid-supplemented mutant mice with pituitary cell implants had significantly higher organ and carcass weights than other mutant groups.

Harkness, John E.

The scattered solar X-ray background in low earth orbit

In order to interpret X-ray observations of the sun-lit earth obtained with the IPC, a detailed model is developed that treats the radiative transfer of solar X-rays in single scattering approximation and employs the relevant scattering processes (elastic Thomson scattering and inelastic fluorescent scattering). The X-ray-bright earth, one of the strongest soft X-ray sources seen by the IPC, can then be understood in terms of solar X-rays scattered in the upper atmosphere. Using the CIRA 1972 Reference Atmosphere, it is possible to account for the observed 'bright earth' X-ray light curves under a variety of different viewing geometries. It is argued that the observed changes in hardness ratio of the scattered radiation can be interpreted as an indication of a change in the ratio of Thomson and fluorescently scattered photons as a function of zenith angle. The relevance of bright earth X-ray observations is further discussed in the context of operating X-ray telescopes in low-earth orbit, as well as in a broader astrophysical context.

Fink, H. H.

Symmetry assessment of an air-blast atomizer spray

This study represents an evaluation of the extent to which conventional and recently introduced modern diagnostics can assess the symmetry of sprays formed by three atomizers of identical design. The conventional diagnostics include sheet-lit photography, patternation, and laser diffraction. The modern diagnostic is laser interferometry (phase Doppler). Symmetry is assessed in ambient conditions for four atomizer orientations, and comparisons are made between the diagnostic techniques. The results demonstrate that conventional and modern diagnostics are consistent in the assessment of symmetry, patternation and phase Doppler are most effective in establishing symmetry of mass flux, and phase Doppler, although more tedious to employ, provides the additional information necessary to establish the sources of detected asymmetries in terms of nonuniformities in droplet velocities, size distributions, volume flux, and concentration.

Mcdonnell, V. G.