Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “#121 Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of potassium titanate fiber on the wear of automotive brake linings

Asbestos reinforcing fiber in an automotive friction material was replaced by an experimental ingredient having better thermal stability, and the effects on wear and friction were studied. A friction materials test machine (SAE J661a) was used to determine friction and wear, under constant energy output conditions, as a function of temperature between 121 and 343 C (250 and 650 F). When potassium titanate fiber replaced one half of the asbestos in a standard commercial lining, with a 40 percent upward adjustment of phenolic resin content, wear above 204 C (400 F) was improved by 40% and friction by 30%. Tests on a full-scale inertial dynamometer supported the findings of the sample dynamometer tests. It was demonstrated that the potassium titanate fiber contributes directly to the improvement in wear and friction.

Halberstadt, M. L.↗

Study of the Printability, Microstructures, and Mechanical Performances of Laser Powder Bed Fusion Built Haynes 230

The nickel-based superalloy, Haynes 230 (H230), is widely used in high-temperature applications, e.g., heat exchangers, because of its excellent high-temperature mechanical properties and corrosion resistance. As of today, H230 is not yet in common use for 3D printing, i.e., metal additive manufacturing (AM), primarily because of its hot cracking tendency under fast solidification. The ability to additively fabricate components in H230 attracts many applications that require the additional advantages leveraged by adopting AM, e.g., higher design complexity and faster prototyping. In this study, we fabricated nearly fully dense H230 in a laser powder bed fusion (L-PBF) process through parameter optimization. The efforts revealed the optimal process space which could guide future fabrication of H230 in various metal powder bed fusion processes. The metallurgical analysis identified the cracking problem, which was resolved by increasing the pre-heat temperature from 80 °C to 200 °C. A finite element simulation suggested that the pre-heat temperature has limited impacts on the maximum stress experienced by each location during solidification. Additionally, the crack morphology and the microstructural features imply that solidification and liquation cracking are the more probable mechanisms. Both the room temperature tensile test and the creep tests under two conditions, (a) 760 °C and 100 MPa and (b) 816 °C and 121 MPa, confirmed that the AM H230 has properties comparable to its wrought counterpart. The fractography showed that the heat treatment (anneal at 1200 °C for 2 h, followed by water quench) balances the strength and the ductility, while the printing defects did not appreciably accelerate part failure.

14 SOLAR ENERGY↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medical Ceramic Oxygen Generator (M-COG) Technology Description

Medical Ceramic Oxygen Generator Technology Description is presented to ISO technical committee 121, subcommittee SC6. Operating principles of ceramic oxygen generation are described, M-COG prototype system designs are described, testing and test results are summarized, and M-COG technology applications for medical oxygen are reviewed and evaluated.

oxygen↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Radiation and thermal effects on the time-dependent response of T300/934 graphite/epoxy

Experimental studies have suggested that radiation, in conjunction with elevated temperatures, may lead to an exacerbation of the time-dependent response of such materials as T300/934 graphite/epoxy. Attention is given to the results of an investigation into such radiation/temperature effects with this composite system; creep tests were conducted on specimens of both irradiated and nonirradiated T300/934 composite and neat 934 resin specimens, at room temperature and 121 C. The radiation was of 1 MeV electrons, for a total dose of 10,000 Mrads; this simulates a 30-year exposure to radiation in geosynchronous orbit. Irradiation at elevated temperature led to a significant creep-response increase in the initial stages of loading.

Yancey, Robert N.↗

Characterization of elastic-viscoplastic properties of an AS4/PEEK thermoplastic composite

The elastic-viscoplastic properties of an AS4/PEEK (APC-2) thermoplastic composite were characterized at 24 C (75 F) and 121 C (250 F) by using a one-parameter viscoplasticity model. To determine the strain-rate effects, uniaxial tension tests were performed on unidirectional off-axis coupon specimens with different monotonic strain rates. A modified Bodner and Partom's model was also used to describe the viscoplasticity of the thermoplastic composite. The experimental results showed that viscoplastic behavior can be characterized quite well using the one-parameter overstress viscoplasticity model.

Yoon, K. J.↗

Thermoradiative energy conversion in infrared interband cascade InAs/GaSb/AlInSb/GaSb type-II superlattice diodes

Thermoradiative energy conversion presents a means for the direct conversion of thermal energy through radiative transfer to a cold scene. However, much of the study of thermoradiative principles has been based on theory and simulations, with only sparse reports on the experimental demonstration of the concept. This work studies thermoradiative energy conversion in InAs/GaSb/AlInSb/GaSb type-II superlattice cascade devices. The devices exhibit a cutoff wavelength of 3.2 μm at 300 K, corresponding to a bandgap of 0.39 eV. Testing under a temperature-controlled chamber and scene demonstrates a maximum power density of 2.9 mW/m2 at a cell temperature of 121 °C. It is consistent with expected values for device operation limited by Shockley–Read–Hall non-radiative recombination. This result is a significant step in providing an experimental demonstration of thermoradiative energy conversion and a means to characterize cell performance, providing a foundation for further development to achieve practical values for power generation.

Islam, Md Toriqul (ORCID:0000000249871320)↗

Effect of Hf Additions to Pt Aluminide Bond Coats on EB-PVD TBC Life

Small Hf additions were incorporated into a Pt aluminide coating during chemical vapor deposition (CVD) on single crystal RENE N5 substrates. Standard yttria-stabilized zirconia top coats were subsequently deposited onto the coated substrates by electron beam-physical vapor deposition (EB-PVD). The coated substrates underwent accelerated thermal cycle testing in a furnace at a temperature in excess of 1121 C (2050 F) (45 minute hot exposure, 15 minute cool to approximately 121 C (250 F)) until the thermal barrier coating (TBC) failed by spallation. Incorporating Hf in the bond coat increased the TBC life by slightly more than three times that of a baseline coating without added Hf. Scanning electron microscopy of the spalled surfaces indicated that the presence of the Hf increased the adherence of the thermally grown alumina to the Pt aluminide bond coat. The presence of oxide pegs growing into the coating from the thermally grown alumina may also partially account for the improved TBC life by creating a near-surface layer with a graded coefficient of thermal expansion.

Nesbitt, James↗

The Application of Remote Sensing using NASA Earth Observations paired with Sociodemographic Indicators to Identify Communities Most Susceptible to Urban Heat Exposure in Austin, Texas

In recent years, Austin, Texas has experienced an increase in population and urban development. Additionally, the City’s climate—already characterized by periods of extreme heat and drought—continues to change. As temperatures and demand for utilities and cooling resources rise, the number of heat-related deaths and illnesses in socially vulnerable populations (e.g., older, lower-income populations) is expected to increase. The City of Austin, The University of Texas at Austin (UT Austin), and The University of Texas Health Science Center at Houston (UT Health) partnered with NASA DEVELOP to examine the distribution of urban heat throughout the City. This project used land surface temperature, greenness, plant water content, and urban surface material analysis parameters derived from NASA Earth observations from Landsat 8 Operational Land Imager (OLI), Landsat 8 Thermal Infrared Sensor (TIRS), and Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS). The project team produced three different indices to create a spatial analysis for the study area including a social vulnerability index (SoVI), heat exposure index (HEI), and an overall heat priority index (HPI) score. This overall score was determined with a weighted analysis of heat-related environmental variables from NASA Earth observations and socioeconomic data from the 2019 American Community Survey. Based on the HPI score, the project team identified 121 census block groups out of 605 total that are designated as being most at risk of adverse impacts from extreme heat events. To test the sensitivity of the HPI, the team used a Monte Carlo analysis using different approaches for geographic scale, variable inclusion, census uncertainty, and index aggregation. Based on the sensitivity analysis, the resulting HPI score showed the metric was consistent with the baseline HPI. This provided increased confidence the score can be used as a tool to make informed infrastructure improvement plans in targeted areas (e.g., siting of cooling centers) and ensure equitable sustainable development.

Ryan Hammock↗

Evaluating algorithmic bias on biomarker classification of breast cancer pathology reports

Objectives: This work evaluated algorithmic bias in biomarkers classification using electronic pathology reports from female breast cancer cases. Bias was assessed across 5 subgroups: cancer registry, race, Hispanic ethnicity, age at diagnosis, and socioeconomic status. Materials and Methods: We utilized 594 875 electronic pathology reports from 178 121 tumors diagnosed in Kentucky, Louisiana, New Jersey, New Mexico, Seattle, and Utah to train 2 deep-learning algorithms to classify breast cancer patients using their biomarkers test results. We used balanced error rate (BER), demographic parity (DP), equalized odds (EOD), and equal opportunity (EOP) to assess bias. Results: We found differences in predictive accuracy between registries, with the highest accuracy in the registry that contributed the most data (Seattle Registry, BER ratios for all registries >1.25). BER showed no significant algorithmic bias in extracting biomarkers (estrogen receptor, progesterone receptor, human epidermal growth factor receptor 2) for race, Hispanic ethnicity, age at diagnosis, or socioeconomic subgroups (BER ratio <1.25). DP, EOD, and EOP all showed insignificant results. Discussion: We observed significant differences in BER by registry, but no significant bias using the DP, EOD, and EOP metrics for socio-demographic or racial categories. This highlights the importance of employing a diverse set of metrics for a comprehensive evaluation of model fairness. Conclusion: A thorough evaluation of algorithmic biases that may affect equality in clinical care is a critical step before deploying algorithms in the real world. We found little evidence of algorithmic bias in our biomarker classification tool. Artificial intelligence tools to expedite information extraction from clinical records could accelerate clinical trial matching and improve care.

60 APPLIED LIFE SCIENCES↗

Full 3D Analysis of the GE90 Turbofan Primary Flowpath

The multistage simulations of the GE90 turbofan primary flowpath components have been performed. The multistage CFD code, APNASA, has been used to analyze the fan, fan OGV and booster, the 10-stage high-pressure compressor and the entire turbine system of the GE90 turbofan engine. The code has two levels of parallel, and for the 18 blade row full turbine simulation has 87.3 percent parallel efficiency with 121 processors on an SGI ORIGIN. Grid generation is accomplished with the multistage Average Passage Grid Generator, APG. Results for each component are shown which compare favorably with test data.

Turner, Mark G.↗

Nuclear Safety [Vol. 16, No. 1, January-February 1975]

Nuclear Safety covers significant developments in the field of nuclear safety. The scope is limited to topics relevant to the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, safety considerations in regard to the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 AEC Working Paper on Population Density Around Nuclear Power-Plant Sites Adapted by J. Ft. Buchanan, 8 Water-Reactor Safety-Research Information Meeting by Wm. B. Cottrell, D. O. Hobson, and G. D. Whitman; ACCIDENT ANALYSIS: 29 Burnout in Boiling Heat Transfer. Part I: Pool-Boiling Systems by A. E. Bergles; PLANT SAFETY FEATURES: 43 Radionuclide Behavior During Normal Operation of Liquid-Metal-Cooled Fast Breeder Reactors. Part 1: Production by C. A. Erdman and A. B. Reynolds; CONSEQUENCES OF EFFLUENT RELEASE: 60 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 1: AEC-Owned Facilities by M. B. Biles and F. E. Coffman, 71 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 2: AEC-Licensed Facilities by L. B. Higginbotham and J. T. Collins; OPERATING EXPERIENCES: 76 Incident at the Lucens Reactor by J. M. Miller, 79 IAEA Symposium on Experience from Operating and Fueling of Nuclear Power Reactors by William A. Pryor, 87 Recent Occurrences at Nuclear Reactors and Their Causes Compiled by William R. Casto, 98 Summary of Operating U. S. Power Reactors as of Nov. 1. 1974, 101 Selected Safety-Related Occurrences Reported in September and October 1974 Compiled by William R. Casto; CURRENT EVENTS: 104 General Administrative Activities Compiled by Wm. B. Cottrell, 110 Action on Power-Reactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 119 Action on Nonreactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 121 Proposed Rule Changes as of Oct. 31, 1974; MISCELLANY: 97 ASTM—Euratom Symposium on Radiation Dosimetry: Developments and Standardization (Announcement), 118 Workshops on In-Pile Filter Testing (Announcement), 119 IAEA Symposium on Radiological Impacts from Releases from Nuclear Facilities into Aquatic Environments (Announcement).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarking Demand Flexibility in Commercial Buildings and Flattening the Duck – Addressing Baseline and Commissioning Challenges

With the transition from our traditional electric grid to a cleaner grid with renewable power generation, there is a need to enable building loads to be flexible. Load shedding and shifting will be essential for flattening the “Duck” for decarbonization. This paper explored the trend in the timing of DR events as a reflection of the grid’s needs using recent four years of event data from 203 retail stores in 11 states. The events are becoming significantly shorter with 2-hour duration being the most popular; shifting to late afternoon and early evening is another trend beyond California. Benchmarking will be essential for accounting DF as a reliable grid resource. This paper addresses a challenging aspect of benchmarking – inaccuracies in counterfactual baseline methods can introduce significant DF metrics variations in addition to weather and building characteristics related factors. The conventional “10/10” with adjustment baseline method has inherent limitation by design for load shifting applications. Therefore, it is imperative to identify alternative methods. This study compared three hourly regression baseline methods with “10/10” methods using two groups of commercial buildings that participated in DR programs: (1) 121 big-box retail stores, and (2) 11 office buildings in CA. The 14-day hourly outdoor temperature regression method was found to produce least error in the tested datasets and is promising for load shifting. The paper also pointed out that commissioning issues can also be a significant barrier for achieving consistent DF performance, which building managers and utilities should be aware of.

Liu, Jingjing↗

STS-86 Day 07 Highlights

On this seventh day of the STS-86 mission, the flight crew, Cmdr. James D. Wetherbee, Jr., Pilot Michael J. Bloomfield, Mission Specialists Scott E. Parazynski, Jean-Loup Chretien, Vladimir G. Titov, Wendy B. Lawrence and Mike Foale are seen in preparations for a planned five-hour spacewalk to retrieve four experiment packages and to test tools and techniques for construction of the International Space Station. Parazynski and Titov are seen floating out of a hatch on Atlantis' tunnel adapter in front of the Orbiter Docking System to begin their spacewalk. They then affix a 121-pound instrument called a Solar Array Cap to the Docking Module for future use by Russian cosmonauts to seal off a suspected breach in the hull of the Spektr Module.

Source record↗

Laser Angioplasty

The principal method of dealing with coronary artery blockage is bypass surgery. A non-surgical alternative available to some patients is balloon angioplasty. For several years, medical researchers have been exploring another alternative that would help a wider circle of patients than the balloon treatment and entail less risk than bypass surgery. A research group is on the verge of an exciting development: laser angioplasty with a 'cool' type of laser, called an excimer laser, that does not damage blood vessel walls and offers non-surgical cleansing of clogged arteries with extraordinary precision. The system is the Dymer 200+ Excimer Laser Angioplasty System, developed by Advanced Intraventional Systems. Used in human clinical tests since 1987, the system is the first fully integrated 'cool' laser capable of generating the requisite laser energy and delivering the energy to target arteries. Thirteen research hospitals in the U.S. have purchased Dymer 200+ systems and used them in clinical trials in 121 peripheral and 555 coronary artery cases. The success rate in opening blocked coronary arteries is 85 percent, with fewer complications than in balloon angioplasty. Food and Drug Administration approval for the system is hoped for in the latter part of 1990. * Advanced Intraventional Systems became Spectranetics in 1994 and discontinued the product.

Source record↗

Autoclave treatment of the classical scrapie agent US No. 13-7 and experimental inoculation to susceptible VRQ/ARQ sheep via the oral route results in decreased transmission efficiency

Scrapie, a prion disease of sheep, is highly resistant to conventional deactivation. Numerous methods to deactivate scrapie have been tested in laboratory animal models, and adequate autoclave treatment can reduce or remove the infectivity of some classical scrapie strains depending on the heating parameters used. In this study, we autoclaved brain homogenate from a sheep with US scrapie strain 13–7 for 30 minutes at 121°C. Genetically susceptible VRQ/ARQ sheep were orally inoculated with 3 grams of the autoclaved brain homogenate. For comparison, a second group of sheep was inoculated with a non-autoclaved brain homogenate. Rectal biopsies were used to assess antemortem scrapie disease progression throughout the study. Five out of ten (5/10) sheep that received autoclaved inoculum ultimately developed scrapie after an experimental endpoint of 72 months. These sheep had a mean incubation period of 26.99 months. Two out of five (2/5) positive sheep had detectable PrP Sc in antemortem rectal biopsies, and two (2/5) other sheep had PrP Sc in postmortem rectal tissue. A single sheep (1/5) was positive for scrapie in the CNS, small intestine, and retropharyngeal lymph node but had negative rectal tissue. All of the sheep (10/10) that received non-autoclaved inoculum developed scrapie with a mean incubation period of 20.2 months and had positive rectal biopsies at the earliest timepoint (14.7 months post-inoculation). These results demonstrate that sheep are orally susceptible to US derived classical scrapie strain 13–7 after autoclave treatment at 121°C for 30 minutes. Differences in incubation periods and time interval to first positive rectal biopsies indicate a partial reduction in infectivity titers for the autoclaved inoculum group.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal expansion of selected graphite-reinforced polyimide-, epoxy-, and glass-matrix composites

The thermal expansion of continuous carbon-fiber reinforced composites with epoxy-, polyimide-, and borosilicate glass-matrices has been measured and compared. The expansion of a rubber-toughened epoxy-matrix/P75S carbon-fiber composite was very different from the expansion of two different single-phase epoxy-matrix/P75S composites, although all three had the same stacking sequence. Reasonable agreement was obtained between measured thermal expansion data and results from classical laminate theory. Microdamage in the graphite/polyimide laminate, induced by 250 cycles between -156 and 121 C, caused a 53 percent decrease in the coefficient of thermal expansion. The thermal expansion of the graphite/glass laminate was not changed after 100 thermal cycles from -129 to 38 C; however, a residual strain of about 10 x 10 to the -6 was observed for the laminate tested.

Tompkins, S. S.↗