Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Validation of Actuator Line and Actuator Disk Models with Filtered Lifting Line Corrections Implemented in Nalu-Wind Large Eddy Simulations of the Atmospheric Boundary Layer

Turbine generator power from simulations using Actuator Line Models and Actuator Disk Models with a Filtered Lifting Line Correction are compared to field data of a V27 turbine. Preliminary results of the wake characteristics are also presented. Turbine quantities of interest from traditional ALM and ADM with the Gaussian kernel (..epsilon..) set at the optimum value for matching power production and that resolve the kernel at all mesh sizes are also presented. The atmospheric boundary layer is simulated using Nalu-Wind, a Large Eddy Simulation code which is part of the ExaWind code suite. The effect of mesh resolution on quantities of interest is also examined.

Actuator Disk Models↗

Calculated stormtime variations in plasmaspheric thermal ion composition

Model calculations describing stormtime variations in the earth's dayside plasmasphere are used to examine variations in ion composition. The model storm is initiated by high-latitude thermospheric heating that generates meridional winds that carry neutral species, momentum, and energy equatorward. The thermosphere acts on the plasmasphere through collisional transfer of momentum and through chemical reactions between neutral species and ions. Over latitudes near the region of thermospheric heating, the thermosphere-plasmasphere coupling processes cause enhancement in the density of oxygen ions while protons are being lost. Meanwhile, densities of oxygen ions and protons near the equator are increasing together, almost in phase. The largest enhancements in ion density develop at latitudes near 45 deg invariant for both oxygen and hydrogen.

Miller, N. J.↗

Selective excitation of tropical atmospheric waves in wave-CISK: The effect of vertical wind shear

The growth of waves and the generation of potential energy in wave-CISK require unstable waves to tilt with height oppositely to their direction of propagation. This makes the structures and instability properties of these waves very sensitive to the presence of vertical shear in the basic flow. Equatorial Kelvin and Rossby-gravity waves have opposite phase tilt with height to what they have in the stratosphere, and their growth is selectively favored by basic flows with westward vertical shear and eastward vertical shear, respectively. Similar calculations are also made for gravity waves and Rossby waves. It is shown that eastward vertical shear of the basic flow promotes CISK for westward propagating Rossby-gravity, Rossby, and gravity waves and suppresses CISK for eastward propagating Kelvin and gravity waves, while westward shear of the basic flow has the reverse effects.

Zhang, Minghua↗

Wind Power as a Virtual Synchronous Generator (WindVSG)

This project investigated the theory, implemented it in hardware, and validated the Wind as a Virtual Isochronous Generator (WindVSG) concept by combining the advantages of modern dynamic inverter technologies with static, dynamic, and transient electromechanical properties of synchronous machines. During this project we demonstrated how to control the inverters of wind turbine generators (wind alone or in parallel with other GFM sources, such battery energy storage) so that wind power behaves like a synchronous machine-based power plant with a conventional prime mover. For this purpose, testing was conducted at NLR ARIES facility with real 2.5 MW wind-turbine generator operating in GFM mode under dynamic and transient conditions. The team also developed models and conducted simulations for GFM wind power to evaluate stability impacts of GFM operation on power grid. This report describes efforts by the NLR team working in collaboration GE Vernova during 3-year project.

17 WIND ENERGY↗

On the physics of waves in the solar atmosphere: Wave heating and wind acceleration

In the area of solar physics, new calculations of the acoustic wave energy fluxes generated in the solar convective zone was performed. The original theory developed was corrected by including a new frequency factor describing temporal variations of the turbulent energy spectrum. We have modified the original Stein code by including this new frequency factor, and tested the code extensively. Another possible source of the mechanical energy generated in the solar convective zone is the excitation of magnetic flux tube waves which can carry energy along the tubes far away from the region. The problem as to how efficiently those waves are generated in the Sun was recently solved. The propagation of nonlinear magnetic tube waves in the solar atmosphere was calculated, and mode coupling, shock formation, and heating of the local medium was studied. The wave trapping problems and evaluation of critical frequencies for wave reflection in the solar atmosphere was studied. It was shown that the role played by Alfven waves in the wind accelerations and the coronal hole heating is dominant. Presently, we are performing calculations of wave energy fluxes generated in late-type dwarf stars and studying physical processes responsible for the heating of stellar chromospheres and coronae. In the area of physics of waves, a new analytical approach for studying linear Alfven waves in smoothly nonuniform media was recently developed. This approach is presently being extended to study the propagation of linear and nonlinear magnetohydrodynamic (MHD) waves in stratified, nonisothermal and solar atmosphere. The Lighthill theory of sound generation to nonisothermal media (with a special temperature distribution) was extended. Energy cascade by nonlinear MHD waves and possible chaos driven by these waves are presently considered.

Musielak, Z. E.↗

Update of Emission Factors of Greenhouse Gases and Criteria Air Pollutants, and Generation Efficiencies of the U.S. Electricity Generation Sector

The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.

20 FOSSIL-FUELED POWER PLANTS↗

It's Not Just About the Megawatts - ARC Industry Forum, The Future of Power Generation

As the world transitions to less carbon intensive energy portfolios, much of the attention understandably centers on generating capacity – replacing megawatts of fossil fuel with megawatts of solar, wind, nuclear, hydroelectric, hydrogen, and more. The actual operation of a reliable grid needs more than just megawatts though: adequate quantities of a portfolio of essential reliability services; flexible and capable power delivery systems; governance to operate in 5-10 minute intervals, forecast hourly, and plan and build on a generational time horizon; and dependable and secure communications. We can choose our fuel mix for climate reasons, but the grid itself and the society that relies upon it impose constraints on those choices that we ignore at our peril.

13 HYDRO ENERGY↗

Proposed Wind Turbine Aeroelasticity Studies Using Helicopter Systems Analysis

Advanced systems for the analysis of rotary wing aeroelastic structures (helicopters) are being developed at NASA Ames by the Rotorcraft Aeromechanics Branch, ARA. The research has recently been extended to the study of wind turbines, used for electric power generation Wind turbines play an important role in Europe, Japan & many other countries because they are non polluting & use a renewable source of energy. European countries such as Holland, Norway & France have been the world leaders in the design & manufacture of wind turbines due to their historical experience of several centuries, in building complex wind mill structures, which were used in water pumping, grain grinding & for lumbering. Fossil fuel cost in Japan & in Europe is two to three times higher than in the USA due to very high import taxes. High fuel cost combined with substantial governmental subsidies, allow wind generated power to be competitive with the more traditional sources of power generation. In the USA, the use of wind energy has been limited mainly because power production from wind is twice as expensive as from other traditional sources. Studies conducted at the National Renewable Energy Laboratories (NREL) indicate that the main cost in the production of wind turbines is due to the materials & the labor intensive processes used in the construction of turbine structures. Thus, for the US to assume world leadership in wind power generation, new lightweight & consequently very flexible wind turbines, that could be economically mass produced, would have to be developed [4,5]. This effort, if successful, would result in great benefit to the US & the developing nations that suffer from overpopulation & a very high cost of energy.

Ladkany, Samaan G.↗

Bethel Wind Energy Construction Project. Final report

Final report for the Bethel (Alaska) Wind Construction project. Under this project, Alaska Village Electric Cooperative, Inc. (AVEC) constructed and commissioned one new 900 kW-capacity wind turbine at a site in Bethel about 3.3 miles NE of the diesel-fired prime power plant. The wind generator’s output will augment the prime source generation provided by the diesel-powered generators.

17 WIND ENERGY↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

Wind as a Distributed Energy Resource

Distributed wind can be installed in a wide range of locations and wind conditions, supporting millions of systems and thousands of gigawatts of power production capacity. As a result, utilities, communities, and nations are looking to distributed generation as an effective way to meet future energy needs. This fact sheet provides an overview of distributed wind, including where distributed wind projects can be located, and how U.S. and international research supports distributed wind applications. This fact sheet was produced as a resource for the International Energy Agency Task 41 members to use as an educational resource.

behind-the-meter wind energy↗

Summary of NASA-Lewis Research Center solar heating and cooling and wind energy programs

NASA is planning to construct and operate a solar heating and cooling system in conjunction with a new office building being constructed at Langley Research Center. The technology support for this project will be provided by a solar energy program underway at NASA's Lewis Research Center. The solar program at Lewis includes: testing of solar collectors with a solar simulator, outdoor testing of collectors, property measurements of selective and nonselective coatings for solar collectors, and a solar model-systems test loop. NASA-Lewis has been assisting the National Science Foundation and now the Energy Research and Development Administration in planning and executing a national wind energy program. The areas of the wind energy program that are being conducted by Lewis include: design and operation of a 100 kW experimental wind generator, industry-designed and user-operated wind generators in the range of 50 to 3000 kW, and supporting research and technology for large wind energy systems. An overview of these activities is provided.

Vernon, R. W.↗

Control system design for the MOD-5A 7.3 mW wind turbine generator

This paper provides descriptions of the requirements analysis, hardware development and software development phases of the Control System design for the MOD-5A 7.3 mW Wind Turbine Generator. The system, designed by General Electric Company, Advanced Energy Programs Department, under contract DEN 3-153 with NASA Lewis Research Center and DOE, provides real time regulation of rotor speed by control of both generator torque and rotor torque. A variable speed generator system is used to provide both airgap torque control and reactive power control. The wind rotor is designed with segmented ailerons which are positioned to control blade torque. The central component of the control system, selected early in the design process, is a programmable controller used for sequencing, alarm monitoring, communication, and real time control. Development of requirements for use of aileron controlled blades and a variable speed generator required an analytical simulation that combined drivetrain, tower and blade elastic modes with wind disturbances and control behavior. An orderly two phase plan was used for controller software development. A microcomputer based turbine simulator was used to facilitate hardware and software integration and test.

Barton, Robert S.↗

Protonic Ceramics for Energy Storage & Electricity Generation with Ammonia (Final Report)

The commercial product resulting from this R&D project will enable cost-effective synthesis of the Carbon Neutral Liquid Fuel (CNLF) ammonia, a common chemical, at a small scale for energy and industrial applications using only intermittent renewable energy, water, and air as feedstocks. These products are also capable of producing electrical energy from the CNLF in a fuel cell mode of operation. Thus, the eventual commercial product enables both single direction production of either CLNF or electricity, or alternatively functions as a fully reversible, self-contained energy storage device. The renewed interest in developing electrolysis systems is driven, in part, by the burgeoning renewable, solar, and wind industries and the need for an energy conversion and storage technology that can convert intermittent solar and wind energy into the production of hydrogen. Electrolysis systems integrated into both distributed and central renewable power plants would utilize solar and wind energy as their primary power source to produce renewably generated hydrogen for local energy storage or chemical feedstock purposes. Ammonia is an excellent surrogate for hydrogen transportation. NH3 presents an attractive alternative to hydrogen as a working fluid in reversible devices towards a sustainable green energy-oriented future. Ammonia can be easily liquefied at room temperature at about 8 bar or at -33°C at ambient pressure. In contrast, the liquefaction temperature of hydrogen is -253°C at ambient pressure. NH3 has a significantly higher volumetric energy density (12.7 MJ/L) than compressed hydrogen (4.5 MJ/L at ~70 MPa) or liquefied hydrogen (8.5 MJ/L). Additionally, ammonia is a widely used raw material for agriculture fertilizer and thus has well-established storage, transport, and handling processes (about 180 million tons of ammonia are produced annually). Techno-economic analysis suggests ammonia is the least expensive fuel among hydrogen, gasoline, natural gas, liquefied petroleum gas, and methanol.

08 HYDROGEN↗

Simulation of Helium-3 Extraction from Lunar Ilmenite

Knowledge of the trapping mechanisms and diffusion characteristics of solar-wind implanted isotopes in the minerals of the lunar regolith will enable the optimization of the processes to extract solar wind gases from regolith particles. Extraction parameters include the temperature and duration of extraction, particle size, and gas yield. Diffusion data will increase the efficiency and profitability of future mining ventures. This data will also assist in optimizing the evaluations of various potential mining sites based on remote sensing data. For instance, if magnesian ilmenite (Mg,Fel.,Ti03) is found to retain He better than stoichiometric ilmenite (FeTi03), remote sensing data for Mg could be considered in addition to Ti and maturity data. The context of the currently discussed work is the mining of helium-3 for potential use as a fuel for fusion energy generation. However, the potential resources deposited by the solar wind include hydrogen (and derived water), helium-4, nitrogen and carbon. Implantation experiments such as those performed for helium isotopes in ilmenite are important for the optimized extraction of these additional resources. These experiments can easily be reproduced for most elements or isotopes of interest.

Kuhlman, K. R.↗

Hybrid Uses of High-Temperature Reservoir Thermal Energy Storage: Lessons Learned from Previous Projects

One of the critical challenges of the green energy transition is resolving the mismatch between energy generation provided by intermittent renewable energy sources such as solar and wind and the demand for energy. There is a need for large amounts of energy storage over a range of time scales (diurnal to seasonal) to better balance energy supply and demand. Subsurface geologic reservoirs provide the potential for storage of hot water that can be retrieved when needed and used for power generation or direct-use applications, such as district heating. It is important to identify potential issues associated with high-temperature reservoir thermal energy storage (HT-RTES) systems so that they can be mitigated, thus reducing the risks of these systems. This paper reviews past experiences from moderate and high-temperature reservoir thermal energy storage (RTES) projects, along with hot water and steam flood enhanced oil recovery (EOR) operations, to identify technical challenges encountered and evaluate possible ways to address them. Some of the identified technical problems that have impacted system performance include: 1) insufficient site characterization that failed to identify reservoir heterogeneity; 2) scaling resulting from precipitation of minerals having retrograde solubility that form with heating of formation brines; 3) corrosion from low pH or high salinity brines; 4) thermal breakthrough between hot and cold wells due to insufficient spacing. Proper design, characterization, construction, and operational practices can help reduce the risk of technical problems that could lead to reduced performance of these thermal energy storage systems.

energy storage↗

Power Production, Inter- and Intra-Array Wake Losses from the U.S. East Coast Offshore Wind Energy Lease Areas

There is an urgent need to develop accurate predictions of power production, wake losses and array–array interactions from multi-GW offshore wind farms in order to enable developments that maximize power benefits, minimize levelized cost of energy and reduce investment uncertainty. New, climatologically representative simulations with the Weather Research and Forecasting (WRF) model are presented and analyzed to address these research needs with a specific focus on offshore wind energy lease areas along the U.S. east coast. These, uniquely detailed, simulations are designed to quantify important sources of wake-loss projection uncertainty. They sample across different wind turbine deployment scenarios and thus span the range of plausible installed capacity densities (ICDs) and also include two wind farm parameterizations (WFPs; Fitch and explicit wake parameterization (EWP)) and consider the precise WRF model release used. System-wide mean capacity factors for ICDs of 3.5 to 6.0 MWkm−2 range from 39 to 45% based on output from Fitch and 50 to 55% from EWP. Wake losses are 27–37% (Fitch) and 11–19% (EWP). The discrepancy in CF and wake losses from the two WFPs derives from two linked effects. First, EWP generates a weaker ‘deep array effect’ within the largest wind farm cluster (area of 3675 km2), though both parameterizations indicate substantial within-array wake losses. If 15 MW wind turbines are deployed at an ICD of 6 MWkm−2 the most heavily waked wind turbines generate an average of only 32–35% of the power of those that experience the freestream (undisturbed) flow. Nevertheless, there is no evidence for saturation of the resource. The wind power density (electrical power generation per unit of surface area) increases with ICD and lies between 2 and 3 Wm−2. Second, EWP also systematically generates smaller whole wind farm wakes. Sampling across all offshore wind energy lease areas and the range of ICD considered, the whole wind farm wake extent for a velocity deficit of 5% is 1.18 to 1.38 times larger in simulations with Fitch. Over three-quarters of the variability in normalized wake extents is attributable to variations in freestream wind speeds, turbulent kinetic energy and boundary layer depth. These dependencies on meteorological parameters allow for the development of computationally efficient emulators of wake extents from Fitch and EWP.

17 WIND ENERGY↗

Limitations of reanalysis data for wind power applications

Wind energy resource estimates commonly depend on simulated wind speed profiles generated by reanalysis or weather models due to the lack of long time series measurements with sufficient coverage at relevant heights (roughly 90 m above ground). However, modeled data, including reanalyses, can be noisy and display a wide range of biases and errors, variously attributed to terrain effects, poor coverage of assimilated inputs, and model resolution. Wind generation records, if available at high temporal and geographical resolution, can provide a proxy for wind measurements and allow for evaluation of reanalyses and weather model wind time series. We use a 7-year-long data set of hourly, plant-level generation records from over 100 wind plants across Texas to evaluate two commonly used reanalysis data sets (MERRA2 and ERA5). Additionally, we use 1-year of records (2019) to evaluate an operational, high-resolution regional weather modeling product (HRRR v3). We find that across the region, and across all modeling products, the modeled representation of wind generation (i.e., wind speeds at hub heights passed through a power curve) has relatively small mean errors when aggregated daily, but that accuracy and hourly correlation have a strong diurnal sensitivity. Accuracy and correlation systematically decline through the evening and markedly improve after sunrise. These diurnal patterns persist even in the highest resolution model tested (HRRR v3). We hypothesize the nighttime decline in accuracy is mostly due to poorly represented boundary layer conditions, perhaps related to model representation of stability, while other uncertainties (such as wake effects) play a secondary role.

17 WIND ENERGY↗