Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Formation of stored heat by means of bled steam during times of load reduction and its use in peak load times

Technical possibilities and economic advantages of integrating hot water storage systems into power plants fired with fossil fuels are discussed. The systems can be charged during times of load reduction and then used for back-up during peak load periods. Investment costs are higher for such systems than for gas turbine power plants fired with natural gas or light oil installed to meet peak load demand. However, by improving specific heat consumption by about 1,000 kcal/k ohm, which thus reduces the related costs, investment costs will be compensated for, so that power production costs will not increase.

Bitterlich, E.↗

Prototype solar heating and cooling systems, including potable hot water

Progress made in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. A comparison of the proposed Solaron Heat Pump and Solar Desiccant Heating and Cooling Systems, installation drawings, data on the Akron House at Akron, Ohio, and other program activities are included.

Bloomquist, D.↗

Computational design of the basic dynamical processes of the UCLA general circulation model

The 12-layer UCLA general circulation model encompassing troposphere and stratosphere (and superjacent 'sponge layer') is described. Prognostic variables are: surface pressure, horizontal velocity, temperature, water vapor and ozone in each layer, planetary boundary layer (PBL) depth, temperature, moisture and momentum discontinuities at PBL top, ground temperature and water storage, and mass of snow on ground. Selection of space finite-difference schemes for homogeneous incompressible flow, with/without a free surface, nonlinear two-dimensional nondivergent flow, enstrophy conserving schemes, momentum advection schemes, vertical and horizontal difference schemes, and time differencing schemes are discussed.

Arakawa, A.↗

Prototype solar heating and cooling systems including potable hot water

These combined quarterly reports summarize the activities from November 1977 through September 1978, and over the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water. The system consists of the following subsystems: solar collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Source record↗

Prototype solar heating and cooling systems including potable hot water

Progress is reviewed in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water. The system consisted of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Source record↗

Operational tests of a solar-energy system in Georgia

Seventy three page report describes one year performance of commercial solar-energy hot-water system. Silicone oil is heat-exchange fluid in tested system, designed to meet needs of family of four. Roll-bend heat exchanger is wrapped around hot-water storage tank. Oil circulates through exchanger and flat-plat solar collectors. Auxiliary energy, to maintain temperature in storage tank, is supplied by 4,500-watt resistance-heating element.

Source record↗

Solar heating and cooling system installed at Leavenworth, Kansas

A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Source record↗

Powerplant Thermal-Pollution Models

Three models predict nature of thermal plumes from powerplant discharge into water. Free-surface model accomodates major changes in ocean currents. Rigid-model accurately predicts changes in thermal plume caused by other inputs and outputs, such as pumped-water storage and hydroelectric-plant discharges. One-dimensional model predicts approximate stratification in lake with such inputs and outputs over a long period.

Lee, S. S.↗

Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

The thermal influence of continents on a model-generated January climate

Two climate simulations were compared. Both climate computations were initialized with the same horizontally uniform state of rest. However, one is carried out on a water planet (without continents), while the second is repeated on a planet with geographically realistic but flat (sea level) continents. The continents in this experiment have a uniform albedo of 0.14, except where snow accumulates, a uniform roughness height of 0.3 m, and zero water storage capacity. Both runs were carried out for a 'perpetual January' with solar declination fixed at January 15.

Spar, J.↗

District wide water resources investigation and management using LANDSAT data. Phase 1: Lake volume

A technique for estimating available water storage volume using LANDSAT data was developed and applied to Lake Washington and Lake Harris in central Florida. The technique can be applied two ways. First, where the historical stage records are available, the historical LANDSAT data can be used to establish the relationship between lake volume and lake stage. In the second case, where the historical stage records are not available, the historical LANDSAT data can be used to estimate the historical lake stage after the lake volume and stage information become available in the future.

Shih, S. F.↗

Seasonal air and water mass redistribution effects on LAGEOS and Starlette

Zonal geopotential coefficients have been computed from average seasonal variations in global air and water mass distribution. These coefficients are used to predict the seasonal variations of LAGEOS' and Starlette's orbital node, the node residual, and the seasonal variation in the 3rd degree zonal coefficient for Starlette. A comparison of these predictions with the observed values indicates that air pressure and, to a lesser extent, water storage may be responsible for a large portion of the currently unmodeled variation in the earth's gravity field.

Gutierrez, Roberto↗

Global surface-water-induced seasonal variations in the earth's rotation and gravitational field

The effects of seasonal changes in continental surface-water storage on the low-degree gravitational-field coefficients (J), the annual wobble excitation (Psi), and the seasonal length-of-day (LOD) variations are investigated by means of numerical simulations based on compiled meteorological data (Willmott et al., 1985) and satellite snow-load estimates (Chao et al., 1987). The formulation of the model equations and the overall characteristics of the data sets are discussed in detail, and the computation results are presented in tables and graphs. The effect on Psi is found to be relatively small due to longitudinal cancellation, but those on LOD and J are considered significant.

Chao, B. F.↗

Design of a surface-based factory for the production of life support and technology support products. Phase 2: Integrated water system for a space colony

Phase 2 of a conceptual design of an integrated water treatment system to support a space colony is presented. This includes a breathable air manufacturing system, a means of drilling for underground water, and storage of water for future use. The system is to supply quality water for biological consumption, farming, residential and industrial use and the water source is assumed to be artesian or subsurface and on Mars. Design criteria and major assumptions are itemized. A general block diagram of the expected treatment system is provided. The design capacity of the system is discussed, including a summary of potential users and the level of treatment required; and, finally, various treatment technologies are described.

Source record↗

Water recovery and management test support modeling for Space Station Freedom

The water-recovery and management (WRM) subsystem proposed for the Space Station Freedom program is outlined, and its computerized modeling and simulation based on a Computer Aided System Engineering and Analysis (CASE/A) program are discussed. A WRM test model consisting of a pretreated urine processing (TIMES), hygiene water processing (RO), RO brine processing using TIMES, and hygiene water storage is presented. Attention is drawn to such end-user equipment characteristics as the shower, dishwasher, clotheswasher, urine-collection facility, and handwash. The transient behavior of pretreated-urine, RO waste-hygiene, and RO brine tanks is assessed, as well as the total input/output to or from the system. The model is considered to be beneficial for pretest analytical predictions as a program cost-saving feature.

Mohamadinejad, Habib↗

Mars surface based factory. Phase 2, task 1C: Computer control of a water treatment system to support a space colony on Mars

In a continued effort to design a surface based factory on Mars for the production of oxygen and water, a preliminary study was made of the surface and atmospheric composition on Mars and determined the mass densities of the various gases in the Martian atmosphere. Based on the initial studies, oxygen and water were determined to be the two products that could be produced economically under the Martian conditions. Studies were also made on present production techniques to obtain water and oxygen. Analyses were made to evaluate the current methods of production that were adaptable to the Martian conditions. Even though the initial effort was the production of oxygen and water, it was found necessary to produce some diluted gases that can be mixed with the oxygen produced to constitute 'breathable' air. The conceptual design of a breathable air manufacturing system, a means of drilling for underground water, and storage of water for future use were completed. The design objective was the conceptual design of an integrated system for the supply of quality water for biological consumption, farming, residential and industrial use.

Fuller, John↗

Climate and the equilibrium state of land surface hydrology parameterizations

For given climatic rates of precipitation and potential evaporation, the land surface hydrology parameterizations of atmospheric general circulation models will maintain soil-water storage conditions that balance the moisture input and output. The surface relative soil saturation for such climatic conditions serves as a measure of the land surface parameterization state under a given forcing. The equilibrium value of this variable for alternate parameterizations of land surface hydrology are determined as a function of climate and the sensitivity of the surface to shifts and changes in climatic forcing are estimated.

Entekhabi, Dara↗

Appendices B thru F, volume 3

The purpose of this investigation was to determine if the intermodule ventilation (IMV) systems and water distribution systems of Space Station Freedom (SSF) modules and nodes should be connected as they are interfaced with those already in operation. It was concluded that the AC configuration and attached LAB and HAB modules and nodes should be interconnected. The H2O circuits should also be interconnected. Interconnecting the air and water provides flexibility of operation and safety comparable to the Assembly Complete (AC) configuration. This requires only only that valves and ducts be provided in the AC nodes. The AC node interfaces should also be scarred to provide for water transfer across these interfaces. Penalties for not connecting the Intermodular Ventilation (IMV) system and water circuits include an additional AR unit, possible increased water storage requirements, and considerable reduction in crew flexibility.

Source record↗