Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Breakdown characteristics of deep-ultraviolet Al 0.6 Ga 0.4 N p-i-n avalanche photodiodes

A top-illuminated deep-ultraviolet Al 0.6 Ga 0.4 N p-i-n avalanche photodiode (APD) structure was designed and grown by metalorganic chemical vapor deposition on an AlN bulk substrate and on two different quality AlN/sapphire templates, and APDs were fabricated and tested. The APD devices with a circular diameter of 20 μm have demonstrated a distinctive reverse-bias breakdown behavior. The reverse breakdown voltage of the APDs is approximately -140 V, which corresponds to a breakdown electric field of 6–6.2 MV/cm for the Al 0.6 Ga 0.4 N material as estimated by Silvaco TCAD simulation. The APDs grown on the AlN bulk substrate show the lowest leakage current density of < 1 × 10 -8 A/cm 2 (at low reverse bias) compared to that of the devices grown on the AlN templates. From the photocurrent measurement, a maximum gain (current limited) of 1.2 × 10 4 is calculated. The average temperature coefficients of the breakdown voltage are negative for APD devices fabricated from both the AlN bulk substrate and the AlN templates, but these data show that the coefficient is the least negative for the APD devices grown on the low-dislocation-density AlN bulk substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards extreme fast charging of 4.6V LiCoO 2 via mitigating high-voltage kinetic hindrance

High-voltage LiCoO 2 (LCO) is an attractive cathode for ultra-high energy density lithium-ion batteries (LIBs) in the 3C markets. However, the sluggish lithium-ion diffusion at high voltage significantly hampers its rate capability. Herein, combining experiments with density functional theory (DFT) calculations, we demonstrate that the kinetic limitations can be mitigated by a facial Mg 2+ +Gd 3+ co-doping method. The as-prepared LCO shows significantly enhanced Li-ion diffusion mobility at high voltage, making more homogenous Li-ion de/intercalation at a high-rate charge/discharge process. The homogeneity enables the structural stability of LCO at a high-rate current density, inhibiting stress accumulation and irreversible phase transition. When used in combination with a Li metal anode, the doped LCO shows an extreme fast charging (XFC) capability, with a superior high capacity of 193.1 mAhg -1 even at the current density of 20C and high-rate capacity retention of 91.3% after 100 cycles at 5C. In conclusion, this work provides a new insight to prepare XFC high-voltage LCO cathode materials.

25 ENERGY STORAGE↗

Formation of a Secondary Phase in Thermally Evaporated MAPbI 3 and Its Effects on Solar Cell Performance

Thermal evaporation is a promising deposition technique to scale up perovskite solar cells (PSCs) to large areas, but the lack of understanding of the mechanisms that lead to high-quality evaporated methylammonium lead triiodide (MAPbI 3 ) films gives rise to devices with efficiencies lower than those obtained by spin coating. Here this work investigates the crystalline properties of MAPbI 3 deposited by the thermal coevaporation of PbI 2 and MAI, where the MAI evaporation rate is controlled by setting different temperatures for the MAI source and the PbI 2 deposition rate is controlled with a quartz crystal microbalance (QCM). Using grazing incident wide-angle X-ray scattering (GIWAXS) and X-ray diffraction (XRD), we identify the formation of a secondary orthorhombic phase (with a Pnma space group) that appears at MAI source temperatures below 155 °C. With synchrotron-based X-ray fluorescence (XRF) microscopy, we show that the changes in crystalline phases are not necessarily due to changes in stoichiometry. The films show a stochiometric composition when the MAI source is heated between 140 to 155 °C, and the samples become slightly MAI rich at 165 °C. Increasing the MAI temperature beyond 165 °C introduces an excess of MAI in the film, which promotes the formation of films with low crystallinity that contain low-dimensional perovskites. When they are incorporated in solar cells, the films deposited at 165 °C result in the champion power conversion efficiency, although the presence of a small amount of low-dimensional perovskite may lead to a lower open-circuit voltage. We hypothesize that the formation of secondary phases in evaporated films limits the performance of PSCs and that their formation can be suppressed by controlling the MAI source temperature, bringing the film toward a phase-pure tetragonal structure. Control of the phases during perovskite evaporation is therefore crucial to obtain high-performance solar cells.

36 MATERIALS SCIENCE↗

Amorphous ZrCl 4 -Based Superionic Conductor as a Cost-Effective Solid Electrolyte for Batteries

Developing highly conductive and cost-effective solid electrolytes is essential for the commercialization of all-solid-state batteries (ASSBs). Zr-based halide electrolytes hold great promise due to their low estimated cost and high oxidation stability. However, the ionic conductivities of most of them are not high enough to enable moderate- and high-rate cycling of ASSBs. Here, fast ion transport is achieved in a group of cost-effective ZrCl 4 -based electrolytes via a design strategy to create highly disordered amorphous structures. Amorphous Li 0.8 ZrCl 4 (SO 4 ) 0.4 , with a low estimated cost of $21 kg –1 , achieves an ionic conductivity of 1.86 mS cm –1 at 25 °C. It also shows a high oxidation limit of 4.5 V vs Li/Li + and good compatibility with high-voltage cathodes, as demonstrated by the stable cycling of ASSBs (73.7% capacity retention after 1000 cycles at 1 C). Synchrotron X-ray diffraction, pair distribution function analysis, and electrochemical impedance spectroscopy reveal that the outstanding conductivity of these amorphous electrolytes is closely related to their short-range and medium-range ordering, revealing new insights for designing high-performance, cost-effective solid electrolytes.

Zhang, Guangxing [Georgia Institute of Technology,↗

DC electric field generation and distribution in magnetized plasmas

Very large DC and AC electric fields cannot be sustained between conducting electrodes because of volume gas breakdown and/or surface field emission. However, very large potential fields are now routinely generated in plasma structures, such as laser generated wake in unmagnetized plasmas. In magnetized plasmas, large DC fields can also be sustained and controlled perpendicular to the magnetic field, but the metallic end plates limiting the plasma, terminating the magnetic field lines, and usually providing the voltage drop feed between the field lines impose severe restrictions on the maximum field. However, it is shown that very large radial DC voltage drops can be sustained by injecting waves of predetermined frequencies and wave vectors, traveling along the azimuthal direction of an axially magnetized plasma cylinder, or by injecting fast neutral particles beams along this azimuthal direction. The large conductivity along the magnetic field lines and the small conductivity between the field lines then distribute this voltage drop. Furthermore, the global power balance and control parameters of wave and beam generated large DC electric fields in magnetized plasmas are identified, described, and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bifacial all-perovskite tandem solar cells

The efficiency of all-perovskite tandem devices falls far below theoretical efficiency limits, mainly because a widening bandgap fails to increase open-circuit voltage. We report on a bifacial all-perovskite tandem structures with an equivalent efficiency of 29.3% under back-to-front irradiance ratio of 30. This increases energy yield and reduces the required bandgap of a wide-bandgap cell. Open-circuit voltage deficit is therefore minimized, although its performance under only front irradiance is not ideal. The bifacial device needs a sputtered rear transparent electrode, which could reduce photon path length and deteriorate stability of Pb-Sn perovskites. Embedding a light-scattering micrometer-sized particle layer into perovskite to trap light, effectively increases absorptance by 5 to 15% in the infrared region. Using a nonacidic hole transport layer markedly stabilizes the hole-extraction interface by avoiding proton-accelerated formation of iodine. These two strategies together increase efficiency of semitransparent Pb-Sn cells from 15.6 to 19.4%, enabling fabrication of efficient bifacial all-perovskite tandem devices.

14 SOLAR ENERGY↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Frequency Support From Electric Vehicles for Advancing Renewable Energy Integration

The integration of renewable energy resources (RERs) in the modern power grid is increasing rapidly because of aggressive decarbonization goals, lower costs, and increased government investment. However, higher penetrations of inverter-based generation can lead to frequency stability issues because of reduced system inertia. This paper develops a framework for quantifying the contribution of electric vehicles (EVs) toward providing frequency support to the grid and thus increasing the penetration limit of renewable energy resources (RERs). EVs are considered to provide both inertial response and primary frequency response support to the grid. A stochastic approach incorporating the uncertainties associated with the behavior of EVs is developed to derive the discharge limit of EV aggregators. A multi-machine system frequency response (MM-SFR) model is developed, which incorporates the dynamic virtual inertia and droop coefficients of EV aggregators derived from the EV control modules. Frequency security constraints are developed from this MM-SFR model, which, along with the converter voltage security and low voltage ride-through constraints, are integrated within a nonlinear optimization framework to determine the RER integration limit. Here, the efficacy of the proposed approach is validated using the RTS-GMLC test system.

25 ENERGY STORAGE↗

Distributed Fiber Optic Sensing to Identify Locations of Resistive Transitions in REBCO Conductors and Magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-x (REBCO, RE = rare earth) can generate strong magnetic fields that are promising for applications in particle accelerators and compact fusion reactors. Traditionally, voltage taps are installed in superconducting magnets to measure the voltage signals due to resistive transitions. The voltage-tap-based diagnostics is important for the development of magnet technology as it can help pinpoint the locations in the magnet windings that limit the magnet performance. The architecture of the multi-tape REBCO cable such as CORC wires, however, makes it difficult to apply the voltage-tap-based diagnostics to identify the locations of resistive transitions. Distributed fiber optic sensing (DFOS) has the potential to address this issue. In this paper, we report the measurements of thermal strain along a CORC wire based on optical frequency domain reflectometry with a maximum spatial resolution of 0.65 mm and a temporal resolution of 10 Hz. The optical fiber is co-wound with the CORC wire that is epoxy impregnated. During the test, current was increased until a resistive transition occurred in the conductor. The spectrum shift of the reflected light along the fiber was recorded. The results suggested that with proper thermal isolation from the cryogen, DFOS can be used to identify the locations of resistive transitions in CORC wires and magnets. In conclusion, the results will allow a better understanding of the causes of resistive transitions in REBCO conductors and magnets, which will help improve the REBCO magnet technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Differentiating Double-Layer, Psuedocapacitance, and Battery-like Mechanisms by Analyzing Impedance Measurements in Three Dimensions

Electrochemical energy storage arises from processes that are broadly categorized as capacitive, pseudocapacitive, or battery-like. Advanced charge-storing materials that are designed to deliver high capacity at a high rate often exhibit a multiplicity of such mechanisms, which complicates the understanding of their charge-storage behavior. In this paper, we apply a “3D Bode analysis” technique to identify key descriptors for fast Li-ion storage processes, where AC impedance data, such as the real capacitance ($C'$) or phase angle ($Φ$), are represented versus the frequency ($f$) and a third independent variable, the applied DC cell voltage. For double-layer processes, a near-constant $C'$ or $Φ$ is supported across the entire voltage range, and the decrease in these values shows a near-linear decrease at higher $f$. For pseudocapacitance, an increase in $C'$ is delivered, accompanied by high $C'$ retention at higher $f$ compared to double-layer processes. Interestingly, the lower $Φ$ values, where $C'$ is highest, suggest that this is a key descriptor for pseudocapacitance, where high-rate charge storage is still facilitated within a kinetically limited regime. For battery-like processes, a high $C'$ is only observed at the voltage at which the material stores charge, while outside that voltage, $C'$ is negligible. The three-dimensional (3D) Bode analysis allows charge-storage dynamics to be mapped out in great detail with more delineation between mechanisms compared to the more frequently deployed kinetic analyses derived from cyclic voltammetry.

25 ENERGY STORAGE↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

High-intensity polarized electron gun featuring distributed Bragg reflector GaAs photocathode

The polarized electron source is a critical component in accelerator facilities such as the electron–ion collider, which requires a polarized electron gun with higher voltage and higher bunch charge than existing sources. One challenge we faced was the surface charge limit of the distributed Bragg reflector GaAs/GaAsP superlattice (DBR-SL-GaAs) photocathode. We suppressed this effect by optimizing the surface doping and heat cleaning procedures. We achieved up to 11.6 nC bunch charge of polarized electron beam. In this report, we discuss the performance of tests of a DBR-SL-GaAs photocathode in the high voltage direct current gun. Possible reasons for the observed peak quantum efficiency wavelength shift are analyzed, and we addressed it by using a wavelength tunable laser. In addition, the impact of the DBR layer and laser on the lifetime is investigated in this paper. The optimal DBR-SL-GaAs operating zone has been proposed, which gave us a long lifetime and high polarization at 30 μA operation. Finally, the success of this polarized gun will be key to the future of the nuclear sciences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Highly Efficient Uniaxial In-Plane Stretching of a 2D Material via Ion Insertion

On-chip dynamic strain engineering requires efficient micro-actuators that can generate large in-plane strains. Inorganic electrochemical actuators are unique in that they are driven by low voltages (≈1 V) and produce considerable strains (≈1%). However, actuation speed and efficiency are limited by mass transport of ions. Minimizing the number of ions required to actuate is thus key to enabling useful “straintronic” devices. Here, it is shown that the electrochemical intercalation of exceptionally few lithium ions into WTe 2 causes large anisotropic in-plane strain: 5% in one in-plane direction and 0.1% in the other. This efficient stretching of the 2D WTe 2 layers contrasts to intercalation-induced strains in related materials which are predominantly in the out-of-plane direction. The unusual actuation of Li x WTe 2 is linked to the formation of a newly discovered crystallographic phase, referred to as Td', with an exotic atomic arrangement. On-chip low-voltage (<0.2 V) control is demonstrated over the transition to the novel phase and its composition. Within the Td'-Li 0.5-δ WTe 2 phase, a uniaxial in-plane strain of 1.4% is achieved with a change of δ of only 0.075. This makes the in-plane chemical expansion coefficient of Td'-Li 0.5-δ WTe 2 far greater than of any other single-phase material, enabling fast and efficient planar electrochemical actuation.

36 MATERIALS SCIENCE↗

Salt-rich solid electrolyte interphase for safer high-energy-density Li metal batteries with limited Li excess

We propose a carbonate-based electrolyte optimized with dual cations and ionic liquid for high-efficiency Li metal batteries with a high-voltage cathode. An average coulombic efficiency of Li deposition of 99.6% is achieved due to the salt-rich solid electrolyte interphase and Na guided uniform Li plating. The Li||NCM811 cells can be cycled with limited Li (N/P = 1) over 90 cycles. An additional advantage is that it improves the thermal stability of the NCM811 cathode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗