Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LDRD External Report Summary

In order to lessen societies dependance on fossil fuels to fight climate change, new energy storage and electrification technology is needed. This work highlights the development of non-conventional electrolytes for lithium-ion and redox flow batteries for electric vehicle and grid storage applications.

25 ENERGY STORAGE↗

Aircraft measurements of electrified clouds at Kennedy Space Center

The space-vehicle launch commit criteria for weather and atmospheric electrical conditions in us at Cape Canaveral Air Force Station and Kennedy Space Center (KSC) have been made restrictive because of the past difficulties that have arisen when space vehicles have triggered lightning discharge after their launch during cloudy weather. With the present ground-base instrumentation and our limited knowledge of cloud electrification process over this region of Florida, it has not been possible to provide a quantitative index of safe launching conditions. During the fall of 1988, a Schweizer 845 airplane equipped to measure electric field and other meteorological parameters flew over KSC in a program to study clouds defined in the existing launch restriction criteria. All aspects of this program are addressed including planning, method, and results. A case study on the November 4, 1988 flight is also presented.

Jones, J. J.↗

Power Analysis of an ePump Applied to the Linear Functions of an Agricultural Planter

Like many other industries, the agricultural industry has recently ex-perienced pressure to reduce vehicle emissions while improving productivity. Electric actuation is perceived as a viable solution to replace or augment hydrau-lic and mechanical actuation. However, electrification presents challenges with regards to linear functions, where hydraulic actuators have advantages in terms of compactness, tolerance to contamination and resistance to shocks. A combined electro-hydraulic actuation architecture can leverage the benefits of both electric and hydraulic actuation, while reducing the drawbacks of both approaches. This work investigates the potential of a centralized electric driven pump (ePump) system powering the pressure-controlled linear functions of an agricul-tural planter, with the goal of improving the operating point of the main supply pump. In this application, the rotary functions are hydraulically actuated, alt-hough such a solution could be applied also to electric rotary actuation. This is accomplished by setting the ePump to boost the pressure supplied by the tractor to the level required by the linear functions. An accumulator is used to stabilize the flow requirements of the linear functions, and control the pressure supplied to the actuators. Two control schemes are proposed for the regulation of the ac-cumulator pressure, one favoring an efficient operating point for the ePump, the other favoring stable steady state operation. A simulation model of the baseline system and proposed system is developed and validated using experimental data from a full-scale machine. Using the vali-dated simulation, both control architectures are then evaluated for improvement in system power consumption and dynamic requirements on the ePump to assess their effectiveness. Both systems demonstrate significant improvement in power consumption over the baseline system, with the best solution improving effi-ciency by 64%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Catalytic Graphitization of Biocarbon for Lithium‐Ion Anodes: A Minireview

Abstract The demand for electrochemical energy storage is increasing rapidly due to a combination of decreasing costs in renewable electricity, governmental policies promoting electrification, and a desire by the public to decrease CO 2 emissions. Lithium‐ion batteries are the leading form of electrochemical energy storage for electric vehicles and the electrical grid. Lithium‐ion cell anodes are mostly made of graphite, which is derived from geographically constrained, non‐renewable resources using energy‐intensive and highly polluting processes. Thus, there is a desire to innovate technologies that utilize abundant, affordable, and renewable carbonaceous materials for the sustainable production of graphite anodes under relatively mild process conditions. This review highlights novel attempts to realize the aforementioned benefits through innovative technologies that convert biocarbon resources, including lignocellulose, into high quality graphite for use in lithium‐ion anodes.

25 ENERGY STORAGE↗

Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems

Major technological advancements and recent policy support are improving the outlook for heavy-duty truck electrification in the United States. In particular, short-haul operations (=200 miles (=322 km)) are prevalent and early candidates for plug-in electric vehicles (EVs) given their short, predictable routes and return-to-base applications, which allows vehicles to recharge when off shift at their depots. Although previous studies investigated the impacts of added electrical loads on distribution systems, which included light-duty EVs, the implications for heavy-duty EV charging are underexplored. Here we summarize the causes, costs and lead times of distribution system upgrades anticipated for depot charging. We also developed synthetic depot charging load profiles for heavy-duty trucks from real-world operating schedules, and found that charging requirements are met at common light-duty EV charging rates (=100 kW per vehicle). Finally, we applied depot charging load profiles to 36 distribution real-world substations, which showed that most can accommodate high levels of heavy-duty EV charging without upgrades.

47 OTHER INSTRUMENTATION↗

Impact of Transportation Electrification on the System's Dynamic Frequency Response

Transportation electrification is an integral component of the energy decarbonization transition. This paper investigates the impact of distributed energy resources (DERs), including distributed photovoltaics (DPV) and electric vehicles (EVs), in the primary frequency response of the power grid. Increasing DER adoption poses challenges to maintaining grid frequency stability. However, DERs' ability to provide fast frequency regulation services-primary frequency response (PFR) and secondary frequency response (SFR)-can be exploited to recover the frequency after an N-1 contingency event in the system. This paper also investigates the importance of a droop control strategy through dynamic models of DPV and EV to provide the primary frequency regulation services following the contingency event. A dynamic EV model, based on the PVD1 model Western Electricity Coordinating Council (WECC) introduced, has been used for the simulation. Further, DERs' primary frequency response is studied for five different cases of DER penetration levels after the system is exposed to the generator trip. Additionally, different frequency regulation capacities of EVs are analyzed. The studies show that an increment in DERs capacity providing effective PFR can improve the system frequency nadir and stabilize the frequency faster after the generation trip contingency.

distributed energy resources↗

Expanding Access to Charging at Home (EACH) Technical Report

This report summarizes the implementation, outcomes, and key learnings of Expanding Access to Charging at Homes (EACH), a nationwide multifamily housing charging initiative focused on accelerating deployment of electric vehicle charging infrastructure at multifamily housing properties. The program combined education, outreach, and technical assistance to support property owners, managers, residents, and industry stakeholders in overcoming barriers to EV charging adoption. The report highlights program strategies, stakeholder engagement, resources developed, and recommendations to help scale charging access at multifamily housing nationwide.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary Optical And Electric Field Pulse Statistics From Storm Overflights During The Altus Cumulus Electrification Study

The Altus Cumulus Electrification Study (ACES) was conducted during the month of August, 2002 in an area near Key West, Florida. One of the goals of this uninhabited aerial vehicle (UAV) study was to collect high resolution optical pulse and electric field data from thunderstorms. During the month long campaign, we acquired 5294 lightning generated optical pulses with associated electric field changes. Most of these observations were made while close to the top of the storms. We found filtered mean and median 10-10% optical pulse widths of 875 and 830 microns respectively while the 50-50% mean and median optical pulse widths are 422 and 365 microns respectively. These values are similar to previous results as are the 10-90% mean and median rise times of 327 and 265 microns. The peak electrical to optical pulse delay mean and median were 209 and 145 microns which is longer than one would expect from theoretical results. The results of the pulse analysis will contribute to further validation of the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS) satellites. Pre-launch estimates of the flash detection efficiency were based on a small sample of optical pulse measurements associated with less than 350 lightning discharges collected by NASA U-2 aircraft in the early 1980s. Preliminary analyses of the ACES measurements show that we have greatly increased the number of optical pulses available for validation of the LIS and other orbital lightning optical sensors. Since the Altus was often close to the cloud tops, many of the optical pulses are from low-energy pulses. From these low-energy pulses, we can determine the fraction of optical lightning pulses below the thresholds of LIS, OTD, and any future satellite-based optical sensors such as the geostationary Lightning Mapping Sensor.

Mach, D. A.↗

Lightning Optical Pulse Statistics from Storm Overflights During the Altus Cumulus Electrification Study

The Altus Cumulus Electrification Study (ACES) was conducted during the month of August, 2002 in an area near Key West, Florida. One of the goals of this uninhabited aerial vehicle (UAV) study was to collect time resolved optical pulse data from thunderstorms. During the month long campaign, we acquired 5294 lightning generated optical pulses. Most of these observations were made while close to the top of the storms. We divided our data into two amplitude groups based on prior NASA U2 aircraft optical data and our pulse characteristics. The group of large pulses with radiance greater than 2.1 mW /sq m sr had mean and median 10 - 10% optical pulse widths of 765 and 735 microns respectively, the 50-50% pulse widths of 396 and 355 microns respectively, and 10-90% rise times of 290 and 260 microns. These values are very similar to the previous U2 based optical results The other group of pulses consisting of slightly more than a quarter of the total pulses observed had radiances less than the minimum values detected in the U2 study. The small pulses were narrower than the large pulses with 5040% mean and median values of 198 and 160 ps respectively. Only 12 % of the flashes contained only small pulses, minimizing the impact of this data on the estimates of detection efficiencies of the orbital instruments, the Lightning Imaging Sensor and Optical Transient Detector.

Mach, D. M.↗

Impact of Transportation Electrification on the System's Dynamic Frequency Response: Preprint

Transportation electrification is an integral component of the energy decarbonization transition. This paper investigates the impact of distributed energy resources (DERs), including distributed photovoltaics (DPV) and electric vehicles (EVs), in the primary frequency response of the power grid. Increasing DER adoption poses challenges to maintaining grid frequency stability. However, DERs' ability to provide fast frequency regulation services-primary frequency response (PFR) and secondary frequency response (SFR)-can be exploited to recover the frequency after an N-1 contingency event in the system. This paper also investigates the importance of a droop control strategy through dynamic models of DPV and EV to provide the primary frequency regulation services following the contingency event. A dynamic EV model, based on the PVDl model Western Electricity Coordinating Council (WECC) introduced, has been used for the simulation. Further, DERs' primary frequency response is studied for five different cases of DER penetration levels after the system is exposed to the generator trip. Additionally, different frequency regulation capacities of EVs are analyzed. The studies show that an increment in DERs capacity providing effective PFR can improve the system frequency nadir and stabilize the frequency faster after the generation trip contingency.

ADVANCED PROPULSION SYSTEMS↗

Propulsion System Hybridization and Electrification and Energy Recovery of the Hydraulic System for a Diesel-Powered Off-Road Carry/Lift Machine Final Technical Report (FTR)

Historically, heavy-duty off-road equipment has prioritized performance, reliability, and cost, with limited emphasis on efficiency. While increasing carbon dioxide (CO 2 ) regulations have driven a focused effort for efficiency in on-road vehicles, off-road machines have remained largely overlooked, leaving significant opportunities for efficiency improvements and emissions reductions. To address this overlooked industry, Michigan Technological University’s Advanced Power Systems Research Center (APS LABS) worked with Pettibone to determine a unique electrified architecture for Pettibone’s heavy-duty off-road material handler, the Cary-Lift 204i, with a goal of 20% fuel savings. The base Cary-Lift uses a diesel engine with no electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Storage Analysis

This study presents a comprehensive techno-economic characterization of energy storage and exible low carbon power generation technologies that can shift energy across days, weeks, or months to balance daily, weekly, and seasonal disparities in supply and demand. Energy storage technologies evaluated here include pumped hydropower storage (PHS), adiabatic and diabatic compressed air energy storage (CAES), vanadium redox flow batteries (VRBs), pumped thermal energy storage (P-TES), and renewably produced hydrogen stored in either geologic formations or underground pipes with re-electrification via combustion turbines in combined cycles, stationary proton exchange membrane (PEM) fuel cells, or the novel use of PEM fuel cells designed for heavy-duty vehicles (HDVs) which are expected to have shorter lives but also lower capital costs. We also evaluate flexible low-carbon power generation systems, including ethanol combustion in gas turbines and natural gas combustion with carbon capture and sequestration (CCS). We estimate current costs with literature data, use learning rates to characterize future costs, and develop capacity factors calibrated to an 85% renewables grid to calculate the levelized cost of energy (LCOE) of each technology. Results illustrate that at the 12-hour storage duration, PHS and CAES have the lowest LCOE with current costs, and VRBs become competitive if future costs are achieved. At the 120-hour storage duration, hydrogen systems with geologic storage and natural gas with CCS achieve the lowest LCOE in both current and future capital cost scenarios. In particular, the new configuration of HDV-PEM fuel cells with hydrogen storage in geologic formations evaluated here could lower the LCOE by 22-27% compared to stationary fuel cell systems typically evaluated and might help enable very high (>80%) renewable energy electric power systems. P-TES and hydrogen stored in underground pipes are the least-cost options at the 120-hour storage duration rating that do not require some form of geologic storage. Sensitivity analysis and Monte Carlo analysis illustrate that the general trends seen in this study are valid for a wide range of capacity factors and future cost scenarios. The study also illustrates that coproducing and selling hydrogen to other markets could reduce the LCOE of hydrogen systems by up to 39%.

carbon capture and sequestration↗

Highly Resolved Projections of Passenger Electric Vehicle Charging Loads for the Contiguous United States: Results From and Methods Behind Bottom-Up Simulations of County-Specific Household Electric Vehicle Charging Load (Hourly 8760) Profiles Projected Through 2050 for Differentiated Household and Vehicle Types

This report documents enhancements made to the TEMPO (Transportation Energy & Mobility Pathway Options TM ) model to project spatially, demographically, and temporally resolved national-scale EV charging load profiles and describes three scenarios and corresponding datasets created for the NREL demand-side grid (dsgrid) project in support of bulk power systems modeling. In brief, TEMPO was enhanced to disaggregate national and annual energy demand projections into household and county-level projections of passenger electric vehicle (EV) hourly charging load profiles (8760 profiles), accounting for consumer, travel, and temperature variations that impact EV energy demand. In alignment with NREL's forward-looking grid modeling, three scenarios for EV adoption covering 2020-2050 were created-- Annual Energy Outlook (AEO) Reference Case, Electrification Futures Study (EFS) High Electrification, and All EV Sales by 2035 --and associated datasets have been included in the dsgrid platform for public use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Airport Ground Support Equipment Analysis

Ground support equipment (GSE) plays a critical role in providing services to aircraft at arrival and departure gates, ensuring smooth and efficient airport operations. As the airline industry seeks to reduce costs and expand energy options, electric GSE (eGSE) is emerging as a promising solution. This project examines the integration of eGSE into airport operations, addressing key considerations such as vehicle deployment, charging infrastructure, and grid impacts. We developed a flexible, bottom-up modeling framework to evaluate energy demands and infrastructure requirements across more than 300 U.S. airports, providing actionable insights to support electrification planning and implementation. The study focuses on eight major types of GSE with commercially available electric counterparts: aircraft tractors, ground power units, baggage tractors, belt loaders, cargo loaders, catering trucks, lavatory trucks, and water trucks. Project results include annual charging load profiles, total energy consumption, and the charger and fleet requirements for each airport.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Resources to Empower Your Fleet

This presentation is on how data collection and analytics can shape fleet electrification plans and help to overcome behavioral barriers.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

EV Champion Training Webinar 1: ZEV and EV Charging Fundamentals [Slides]

The Electric Vehicle (EV) Champion Training Series, hosted by the National Renewable Energy Laboratory (NREL), is tailored for fleet managers, facility managers, and other stakeholders involved in the deployment of EVs and charging stations. This series equips participants with the skills and knowledge necessary to become subject matter experts in EV implementation. This is the first training in a four-part series and serves as an introductory training. This training covers fundamental topics such as EV and charging technology, utility basics, and financial considerations for EVs. Additionally, this session introduces the Federal Fleet ZEV Ready Center framework, a one-stop location for federal fleet electrification resources. Participants will gain a solid foundation to support the effective deployment and management of EVs and their infrastructure. Visit the Federal Fleet ZEV Ready Center website to learn more about the ZEV Ready Center process. EV Champion Training Webinar 1: ZEV and EV Charging Fundamentals will enable attendees to: Identify EV and EV charging technology fundamentals; Recognize EV market and GSA Schedule options; Identify utility basics, incentives, and rates as they relate to EV charging; and Identify methods to calculate life cycle costs for EVs and gasoline vehicles.

30 DIRECT ENERGY CONVERSION↗

Energy consumption and charging load profiles from long-haul truck electrification in the United States

Abstract The urgent need to decarbonize the transportation sector combined with falling battery prices has spurred industry and policy interest in long-haul truck electrification. The charging behavior and resulting loads from electrified long-haul freight trucks are crucial for the smooth operation of the electric grid and have far-reaching environmental impacts (e.g., greenhouse gas and other air pollutant emissions). However, the aggregate energy impact of a fleetwide shift to electrified long-haul freight trucking has not been explored. This study combines electric truck design scenarios, bottom-up truck weight modeling, vehicle energy modeling, large-scale truck traffic data, and simulation of likely operation and charging behaviors to estimate end-use energy consumption and location-specific hourly charging loads for a national fleet of long-haul electric trucks. Relative to a fleet of future diesel trucks, electrification would reduce direct end-use energy consumption by 0.9 × 10 18 J (0.9 quadrillion BTU), but electrification might increase life cycle energy consumption depending on the electricity source. The electricity required to charge long-haul electric trucks is equivalent to five percent of annual electricity consumption in the United States (US). The simulated truck charging loads peak during the day across the US grid regions, but the charging peaks’ exact timing is sensitive to when trucks are dispatched for operation. The load shapes suggest that electric trucks’ charging loads can coincide with peaks in solar power generation, and planning could enable on- or off-site integration between truck charging stations and renewable electricity generation.

Tong, Fan (ORCID:0000000346613956)↗