Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “use cases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Performance Assessment of LunaNet’s Augmented Forward Signal

LunaNet provides a common set of interoperable specifications for communication and position, navigation and time (PNT) services and interfaces soon to be implemented in lunar vicinity. The LunaNet Interoperability Specification (LNIS) provides the design for the GNSS-like Augmented Forward Signal (AFS), which enables orbiting and surface users in lunar space, such as Artemis, to estimate their position, velocity, and time. The specification of AFS defines two orthogonal signal components on a single carrier: the in-phase component (AFS-I), a lower-chip-rate data channel tailored for applications where low SWaP (Size, Weight, and Power) is critical (e.g., IoT devices or search and rescue), and the quadrature component (AFS-Q), a high-chip-rate data-less pilot signal for high-precision, robust lunar navigation and positioning applications. An initial description of AFS was provided in LNIS 2023, with initial analysis results shown in Dafesh 2024 and Dafesh 2025, and the current signal in space description provided in LNIS 2025. As part of NASA's Lunar Communication Relay and Navigation Systems (LCRNS) project, this work expands upon the initial analysis results and proposes a new expanded set of AFS-Q spreading codes that exceed the cross-correlation and autocorrelation sidelobe performance of L1C and other GNSS signals, while providing additional expansion capabilities for future service satellites. A set of 420 codes was selected from a Weil-based code derived from the prime number 10247, which is larger than the 10243 prime number used to derive BeiDou’s B1C Weil sequences. Both the initial set of 210 codes and the expanded set of 420 codes are shown to provide the best cross-correlation of any 10230-chip satellite navigation codes. The performance is demonstrated for hierarchical sets of spreading codes optimized and organized in sets of 30 codes. The work also compares LunaNet’s AFS to terrestrial GNSS signals in terms of acquisition, tracking, and data demodulation performance. Performance is evaluated for receivers that only track the 1.023 MCPS data channel spreading code for low SWaP IoT use cases, as well as for receivers that track both the 1.023 MCPS data channel and the 5.115 MCPS pilot channel spreading code for high-performance use cases. Performance is assessed in the presence of interference and thermal noise. The analysis is performed in terms of expected operating conditions on the lunar surface. Several unique flexibility aspects of the augmented forward signal are described, including the use of the Q channel’s secondary and tertiary codes to enable variable coherent integrations during acquisition. This is compared to GNSS signals such as L5/E5 and MBOC in terms of achievable processing gain for interference mitigation versus acquisition complexity. The work details acquisition and tracking techniques used to optimally acquire and track the primary, secondary, and tertiary codes on the Q channel, as well as acquisition of the I channel spreading code. Acquisition of the 8 ms, Q channel spreading code is also compared to joint acquisition of the I and Q channel primary codes in noise and interference environments

LCRNS↗

Estimating Forest Stand Height in Savannakhet, Lao PDR Using InSAR and Backscatter Methods with L-Band SAR Data

Forest stand height (FSH), or average canopy height, serves as an important indicator for forest monitoring. The information provided about above ground biomass for greenhouse gas emissions reporting, and estimating carbon storage is relevant for reporting for Reducing Emissions from Deforestation and Forest Degradation (REDD+). A novel forest height estimation method utilizing a fusion of backscatter and Interferometric Synthetic Aperture Radar (InSAR) data from JAXA’s Advanced Land Observing Satellite Phased Array type L-band Synthetic Aperture Radar (ALOS PALSAR) are applied to a use case in Savannakhet, Lao. Compared with LiDAR, the estimated height from the fusion method had an RMSE of 4.90 m and an R2 of 0.26. These results are comparable to previous studies using SAR estimation techniques. Despite limitations of data quality and quantity, the Savannakhet, Lao use case demonstrates the applicability of these techniques utilizing L-band SAR data for estimating FSH in tropical forests and can be used as a springboard for use of L-band data from the future NASA-ISRO SAR (NISAR) mission.

remote sensing↗

Evaluating multistation phase picking algorithm phase neural operator (PhaseNO) on local seismic networks

Reliable automatic phase picking is important for many seismic applications. With the development of machine learning approaches, many algorithms are proposed, evaluated and applied to different areas. Many of these algorithms are single station based, while recent proposed methods start to combine surrounding stations into consideration in the problem of phase picking. Among these algorithms, the phase neural operator (PhaseNO) shows promising results on regional data sets comparing to existing algorithms. But there are many use cases for the local seismic networks in our community, therefore in this paper we evaluate the performance of PhaseNO on four different local data sets and compare the results to PhaseNet and EQTransformer. We used both individual phase picking metrics as well as association metrics to illustrate the performance of PhaseNO. By manually reviewing the newly detected events, we find that the PhaseNO model outperforms the single station-based approaches in the local-scale use cases due to its consideration of coherent signals from multiple stations. We also explored PhaseNO’s behaviours when only using one station, as well as gradually increasing the number of stations in the seismic network to better understand its behaviour. Overall, using the off-the-shelf machine learning based phase pickers, PhaseNO demonstrated its good performance on local-scale seismic networks.

58 GEOSCIENCES↗

Assessing the energy equity benefits of energy storage solutions

Safety, reliability, efficiency, and affordability are no longer the sole tenets of electric grid planning. The evolving social and policy climate have placed new explicit requirements on the electric grid, including resilience, decarbonization, and energy equity and justice. Integrating energy equity strategies into modern grid design is intended to achieve a fair and just distribution of benefits within the energy system. This study aims to characterize the energy equity and community benefits of energy storage systems (ESS) under the following three use-case models: utility ESS that are operated within the distribution system; community-owned ESS; and behind-the-meter ESS that are customer-owned to serve the household. The goal of this energy equity analysis is to characterize the environmental, economic, and social benefits of ESS through applied metrics such as energy burden, energy poverty, energy vulnerability, job creation, and more. A 13.8 kV, 265 node representative feeder corresponding to the hot-humid climate of Louisiana, chosen for its high energy burden, frequent hurricanes and outage events, was used to perform a storage adequacy analysis for six different outage scenarios to determine energy storage access for each use-case. The results of this analysis are then used to characterize both the grid and equity benefits of storage solutions to inform a prioritization framework matching community needs with system preferences for utility planning processes, market regulations, and the wider network of energy system stakeholders.

Energy Equity, energy justice, equity, reliability↗

Enhancing Electron Microscopy Image Classification Using Data Augmentation

Manual labeling for machine learning tasks such as image classification is tedious and labor-intensive; as a result, scientific datasets suitable for deep learning applications are scarce and limited. While data augmentation techniques have shown promise for extending image datasets, very little work has been done to understand the impact of combining multiple augmentation methods sequentially or the limits of their effectiveness when combined. Our work addresses this gap by examining how standard and combinatorial data augmentation affects the performance of machine learning models when trained on small datasets for label classification tasks. For our analysis, we generate single, double and quadruple-augmented datasets for a microscopy image classification task using six standard augmentation methods, and compare the resultant improvements observed in binary classification accuracy with three standard image classification models (DenseNet169, MobileNetV2, ResNet101V2). Our experiments show a non-monotonic relationship between the number of simultaneous augmentation methods and classification accuracy, indicating that there is a trade-off between the degree of augmentation and the model performance. These findings suggest that the optimal number of augmentation methods will vary by domain and use case. We also find that the order in which augmentation methods are applied to a limited dataset matters when combining augmentation schemes, with our use case showing performance differences up to 2.6% when the augmentation order is reversed for double-augmented datasets. Our work offers insights to the limits of data augmentation when working on image classification tasks with limited datasets.

Welsman, Jordan A↗

MACHETE: Environment for Space Networking Evaluation

Space Exploration missions requires the design and implementation of space networking that differs from terrestrial networks. In a space networking architecture, interplanetary communication protocols need to be designed, validated and evaluated carefully to support different mission requirements. As actual systems are expensive to build, it is essential to have a low cost method to validate and verify mission/system designs and operations. This can be accomplished through simulation. Simulation can aid design decisions where alternative solutions are being considered, support trade-studies and enable fast study of what-if scenarios. It can be used to identify risks, verify system performance against requirements, and as an initial test environment as one moves towards emulation and actual hardware implementation of the systems. We describe the development of Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE) and its use cases in supporting architecture trade studies, protocol performance and its role in hybrid simulation/emulation. The MACHETE environment contains various tools and interfaces such that users may select the set of tools tailored for the specific simulation end goal. The use cases illustrate tool combinations for simulating space networking in different mission scenarios. This simulation environment is useful in supporting space networking design for planned and future missions as well as evaluating performance of existing networks where non-determinism exist in data traffic and/or link conditions.

Jennings, Esther H.↗

Mass Optimization of a Multilayered Shield for Transportable Microreactors

The ability to easily transport microreactors is a major selling point for deploying microreactors to remote areas. However, this creates a unique shielding challenge, especially when the microreactor is being shipped after irradiation. A traditional reactor configuration utilizes a separate biological shield and pressure vessel to meet radiological shielding and pressure needs. The limited space available for transportable microreactors for both shielding and pressure vessels requires a revised assessment of separating out the biological shield and pressure vessel. To address these concerns, we examine a nuclear-grade sandwich composite (NGSC) that combines the reactor pressure vessel and biological shielding functions into a single component. Through a series of optimization problems for both transportation and operational use cases, the NGSC is able to minimize dose, minimize the vessel cost, and ensure that weight requirements are met for transportation. Initial results show that using a tungsten-tetraboride cermet in the first two layers of a six-layer NGSC provides adequate shielding for both use cases. These results show promise that an NGSC has enough overlap between operational and transportation cases to help reduce the design space for future analysis and assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing Vulnerabilities Associated with Connected Lighting: Exploring Authorization Protocols

Cities are upgrading their infrastructure and converting traditional indoor and outdoor luminaires to Connected Lighting Systems equipped with sensors in an aggressive effort to reduce energy consumption, increase sustainability, and improve the quality of life. When you take something seemingly benign like a lighting system and connect it to the internet, if improperly secured a potential attack vector for hackers is created. Hackers could then access sensitive information, pivot into other networks, shut down services, or enslave devices to do their bidding. In attempt to close this attack vector and secure these systems, this paper extends previous work that investigated, compared and contrasted authentication vulnerabilities in Connected Lighting Systems that identified the need for additional testing and improved test method documentation. One additional authentication test and four new authorization tests were developed utilizing the Open Web Application Security Project (OWASP) as a test development and documentation guide. The new tests were integrated with the previous work to develop an updated test method with a focus on describing test procedures to make them easy to understand and repeat. In addition, a first Connected Lighting System use case was established to begin developing threat profiles that will aid in the identification of vulnerabilities whose focus areas extend beyond authentication and authorization. This use case describes the generation and flow of CLS data which assists in specifying methods to harden CLSs from outside interference and exploitation that can be implemented immediately on existing CLSs and as new products come to market.

97 MATHEMATICS AND COMPUTING↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Critical Interference Mechanisms for Marine Renewable Energy-powered Ocean Observing Platforms

Marine renewable energy devices, such as wave energy converters or tidal turbines, not only have the potential to provide clean, reliable power to the grid but may also offer new opportunities for ocean exploration by providing power for oceanographic sensors where other sources cannot. However, an important consideration in making this vision a reality is understanding whether the marine energy devices may interfere with oceanographic measurements. Interference may occur through several pathways, including sound produced by the device and the motion of the device itself. In this report, we provide an overview of interference pathways and their implications before exploring two use cases for marine energy-powered ocean observing platforms: a tidal-powered passive acoustic monitoring system and wave-powered wave measurement buoys. For each use case, we review the relevant literature and underlying physics of the systems as they are relevant to the desired measurements before making recommendations for design of such systems.

16 TIDAL AND WAVE POWER↗

Assessment of Materials-Based Options for On-Board Hydrogen Storage for Rail Applications

The objective of this project was to evaluate material- and chemical-based solutions for hydrogen storage in rail applications as an alternative to high-pressure hydrogen gas and liquid hydrogen. Three use cases were assessed: yard switchers, long-haul locomotives, and tenders. Four storage options were considered: metal hydrides, nanoporous sorbents, liquid organic hydrogen carriers, and ammonia, using 700 bar compressed hydrogen as a benchmark. The results suggest that metal hydrides, currently the most mature of these options, have the highest potential. Storage in tenders is the most likely use case to be successful, with long-haul locomotives the least likely due to the required storage capacities and weight and volume constraints. Overall, the results are relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of fuel cell electric locomotives. The results obtained here will contribute to the development of technical storage targets for rail applications that can guide future research. Moreover, the knowledge generated by this project will assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Synthesis of UML Designs from Requirements in an Iterative Process

The Unified Modeling Language (UML) is gaining wide popularity for the design of object-oriented systems. UML combines various object-oriented graphical design notations under one common framework. A major factor for the broad acceptance of UML is that it can be conveniently used in a highly iterative, Use Case (or scenario-based) process (although the process is not a part of UML). Here, the (pre-) requirements for the software are specified rather informally as Use Cases and a set of scenarios. A scenario can be seen as an individual trace of a software artifact. Besides first sketches of a class diagram to illustrate the static system breakdown, scenarios are a favorite way of communication with the customer, because scenarios describe concrete interactions between entities and are thus easy to understand. Scenarios with a high level of detail are often expressed as sequence diagrams. Later in the design and implementation stage (elaboration and implementation phases), a design of the system's behavior is often developed as a set of statecharts. From there (and the full-fledged class diagram), actual code development is started. Current commercial UML tools support this phase by providing code generators for class diagrams and statecharts. In practice, it can be observed that the transition from requirements to design to code is a highly iterative process. In this talk, a set of algorithms is presented which perform reasonable synthesis and transformations between different UML notations (sequence diagrams, Object Constraint Language (OCL) constraints, statecharts). More specifically, we will discuss the following transformations: Statechart synthesis, introduction of hierarchy, consistency of modifications, and "design-debugging".

Schumann, Johann↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

A review of privacy in energy applications

As the distribution system continues to experience an increase in distributed energy resource (DER) and electric vehicle (EV) penetration, so does the need for new solutions that can help grid operators manage and leverage their capabilities. This will undoubtedly lead to new operational schemes and business opportunities that will transform the traditional consumer into a prosumer who will be more actively engaged in grid operations. Although the field is still under active development, many of the potential use cases presented in literature or industry are built upon edge computing, two-way communications, and other innovative computational constructs to attain their goals. However, at their core, many use cases assume a great level of data access to aid with the decision-making process, an assumption that may need to be revised to ensure fair and equitable operational processes are maintained. This may be particularly true as edge resources are predicted to participate in retail-side, many-to-many, or peer-to-peer markets and thus may lead to financial impacts if data access considerations are ignored. The need to revise data access mechanisms can be further justified by the introduction of new participants into the operational process, who do not have the same level of trust, nor the incentives to focus on energy delivery as their primary objective. At the same time, more consumers are becoming aware of their own data, and the potential impacts of its abuse. To help solution developers better understand these risks, this report has been developed to offer an initial introduction to the topic of privacy. This is achieved by 1) Highlighting the need for privacy-aware solutions; 2) Encouraging system designers to be inquisitive about the status quo; 3) Documenting the existing threat space; 4) Presenting and evaluating tools that may be helpful towards enabling better privacy postures; and 5) Making recommendations to encourage the adoption of better practices. From a technical perspective, the report focuses on evaluating two potential techniques by applying them to the Transactive Energy Space. Based on the obtained results, it can be established that differential privacy (DP) methods may have limited applicability when highly correlated, time-series data records need to be protected. However, DP may be a powerful tool when it is used to aggregate and analyze mid-size and large-size data sets in a more traditional statistical environment. The second tool under evaluation is threshold cryptography, which can guarantee complete secrecy (and thus privacy) but requires the establishment of key management procedures and dedicated communication channels for key coordination. Therefore, due to its increased computational overhead, the use of threshold cryptography must be weighted using a cost/benefit analysis on a per-application basis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Unified Testing Platform to Mature Blockchain Applications for Grid Emulation Environments

Blockchain technology is a relatively novel technology that can be used to develop more decentralized, autonomous and tamper-evident solutions. A feature that can aid Transactive Energy Systems to reach their goals by enabling individual actors to communicate and reach consensus with other participants in a more decentralized fashion. However, technical barriers to evaluate and adopt this type of technology within the electrical domain still exist. To facilitate this task, BLOSEM Unified Testing Platform (UTP), a DOE-sponsored, multi-lab effort intends to accelerate the development of solutions by offering a common set of reusable services that can be used to interconnect existent grid tools with blockchain services. UTP is intended to serve as development platform that can provide application engineers with the technical means to evaluate potential blockchain solutions, by enabling them to concentrate on the actual application functionalities while at the same time abstracting the connectivity and performance measurement tasks. The use of BLOSEM UTP is further demonstrated by implementing two potential use cases that are intended to validate both the feasibility of implementing these applications as blockchain-based solutions while also demonstrating the features provided by UTP.

blockchain co-simulation↗