The pervasive and multifaceted influence of biocrusts on water in the world's drylands
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Abstract The advent of chatbots raises the possibility of a paradigm shift across society including the most technical of fields with regard to access to information, generation of knowledge, and dissemination of education and training. Photochemistry is a scientific endeavor with roots in chemistry and physics and branches that encompass diverse disciplines ranging from astronomy to zoology. Here, five chatbots have each been challenged with 13 photochemically relevant queries. The chatbots included ChatGPT 3.5, ChatGPT 4.0, Copilot, Gemini Advanced, and Meta AI. The queries encompassed fundamental concepts (e.g., “Why is the fluorescence spectrum typically the mirror image of the absorption spectrum?”), practical matters (e.g., “What is the inner filter effect and how to avoid it?”), philosophical matters (“Please create the most important photochemistry questions.”), and specific molecular features (e.g., “Why are azo dyes non‐fluorescent?”). The chatbots were moderately effective in answering queries concerning fundamental concepts in photochemistry but were glaringly deficient in specialized queries for dyes and fluorophores. In some instances, a correct response was embedded in verbose scientific nonsense whereas in others the entire response, while grammatically correct, was utterly meaningless. The unreliable accuracy makes present chatbots poorly suited for unaided educational purposes and highlights the importance of domain experts.
Wide-area persistent imaging systems are becoming increasingly cost effective and now large areas of the earth can be imaged at relatively high frame rates (1-2 fps). The efficient exploitation of the large geo-spatial-temporal datasets produced by these systems poses significant technical challenges for image and video analysis and data mining. In recent years there has been significant progress made on stabilization, moving object detection and tracking and automated systems now generate hundreds to thousands of vehicle tracks from raw data, with little human intervention. However, the tracking performance at this scale, is unreliable and average track length is much smaller than the average vehicle route. This is a limiting factor for applications which depend heavily on track identity, i.e. tracking vehicles from their points of origin to their final destination. In this paper we propose and investigate a framework for wide-area motion imagery (W AMI) exploitation that minimizes the dependence on track identity. In its current form this framework takes noisy, incomplete moving object detection tracks as input, and produces a small set of activities (e.g. multi-vehicle meetings) as output. The framework can be used to focus and direct human users and additional computation, and suggests a path towards high-level content extraction by learning from the human-in-the-loop.
Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937.9% for the 500 mA FBP, 25 mA SIR, and 25 mA FBP, respectively. In numerical simulations, SIR mitigated streak artifacts in the low dose data and yielded flow maps with mean error <7% and standard deviation <9% of mean, for 30×30 pixel ROIs (12.9 × 12.9 mm{sup 2}). In comparison, low dose FBP flow errors were −38% to +258%, and standard deviation was 6%–93%. Additionally, low dose SIR achieved 4.6 times improvement in flow map CNR{sup 2} per unit input dose compared to low dose FBP. Conclusions: SIR reconstruction can reduce image noise and mitigate streaking artifacts caused by photon starvation in dynamic CT myocardial perfusion data sets acquired at low dose (low tube current), and improve perfusion map quality in comparison to FBP reconstruction at the same dose.
Purpose: Several commercial software packages have been recently released that allow the user to apply deformable registration algorithms (DRA) for image fusion and dose propagation. Although the idea of anatomically tracking the daily patient dose in the context of adaptive radiotherapy or merely adding the dose from prior treatment to the current one is very intuitive, the accuracy and applicability of such algorithms needs to be investigated as it remains somewhat subjective. In our study, we used true anatomical data where we introduced changes in the density, volume and location of segmented structures to test the DRA for its sensitivity and accuracy. Methods: The CT scan of a prostate patient was selected for this study. The CT images were first segmented to define structure such as the PTV, bladder, rectum, intestines and pelvic bone anatomy. To perform our study, we introduced anatomical changes in the reference patient image set in three different ways: (i) we kept the segmented volumes constant and changed the density of rectum and bladder in increments of 5% (ii) we changed the volume of rectum and bladder in increments of 5% and (iii) we kept the segmented volumes constant but changed their location by moving their COM in increments of 3mm. Using the Velocity software, we evaluated the accuracy of the DRA for each incremental change in all three scenarios. Results: The DRA performs reasonably well when the differential density difference against the background is more than 5%. For the volume change study, the DRA results became unreliable for relative volume changes greater than 10%. Finally for the location study, the DRA performance was acceptable for shifts below 9mm. Conclusion: Site specific and patient specific QA for DRA is an important step to evaluate such algorithms prior to their use for dose propagation.
Purpose: Challenges for radiation therapy in developing countries include unreliable infrastructure and high patient load. We propose a system to treat whole breast in the prone position without computed tomography and/or planning software. Methods: Six parameters are measured using calipers and levels with the patient prone in the treatment position. (1) The largest separation; (2) the angle that separation makes with the horizontal; (3) the separation 2 cm posterior to the nipple; (4) the vertical distance between these two separations; (5) the sup/inf length and (6) angle of the desired posterior field edge. The data in (5) (6) and (2) provide field length, collimator and gantry angles. Isocenter is set to the midpoint of (1), anterior jaw setting is 20cm (half-beam setup), and the dose is prescribed to a point 1.5 cm anterior to isocenter. MUs and wedge angles are calculated using an MU calculator and by requiring 100% dose at that point and 100-105% at the midpoint of (3). Measurements on 30 CT scans were taken to obtain the data 1-6. To test the resulting MU/wedge combinations, they were entered into Eclipse (Varian) and dose distributions were calculated. The MU/wedge combinations were recorded and tabulated. Results: Performing a dose volume histogram analysis, the contoured breast V95 was 90.5%, and the average V90 was 94.1%. The maximum dose never exceeded 114.5%, (average 108%). The lung V20 was <5% for 96.7%, and the heart V5 was <10% for 93.3% of our sample. Conclusion: A method to provide prone whole breast treatment without CT-planning was developed. The method provides reasonable coverage and normal tissue sparing. This approach is not recommended if imaging and planning capabilities are available; it was designed to specifically avoid the need for CT planning and should be reserved to clinics that need to avoid that step.
Purpose: Breathing irregularity is common, causing unreliable prediction in tumor motion for correlation-based surrogates. Both tidal volume (TV) and breathing pattern (BP=ΔVthorax/TV, where TV=ΔVthorax+ΔVabdomen) affect lung motion in anterior-posterior and superior-inferior directions. We developed a novel respiratory motion perturbation (RMP) model in analytical form to account for changes in TV and BP in motion prediction from simulation to treatment. Methods: The RMP model is an analytical function of patient-specific anatomic and physiologic parameters. It contains a base-motion trajectory d(x,y,z) derived from a 4-dimensional computed tomography (4DCT) at simulation and a perturbation term Δd(ΔTV,ΔBP) accounting for deviation at treatment from simulation. The perturbation is dependent on tumor-specific location and patient-specific anatomy. Eleven patients with simulation and treatment 4DCT images were used to assess the RMP method in motion prediction from 4DCT1 to 4DCT2, and vice versa. For each patient, ten motion trajectories of corresponding points in the lower lobes were measured in both 4DCTs: one served as the base-motion trajectory and the other as the ground truth for comparison. In total, 220 motion trajectory predictions were assessed. The motion discrepancy between two 4DCTs for each patient served as a control. An established 5D motion model was used for comparison. Results: The average absolute error of RMP model prediction in superior-inferior direction is 1.6±1.8 mm, similar to 1.7±1.6 mm from the 5D model (p=0.98). Some uncertainty is associated with limited spatial resolution (2.5mm slice thickness) and temporal resolution (10-phases). Non-corrected motion discrepancy between two 4DCTs is 2.6±2.7mm, with the maximum of ±20mm, and correction is necessary (p=0.01). Conclusion: The analytical motion model predicts lung motion with accuracy similar to the 5D model. The analytical model is based on physical relationships, requires no training, and therefore is potentially more resilient to breathing irregularities. On-going investigation introduces airflow into the RMP model for improvement. This research is in part supported by NIH (U54CA137788/132378). AY would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.
Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.
Purpose: This study examines the effect on texture analysis due to variable reconstruction of PET images in the context of an adaptive FDG PET protocol for node positive gynecologic cancer patients. By measuring variability in texture features from baseline and intra-treatment PET-CT, we can isolate unreliable texture features due to large variation. Methods: A subset of seven patients with node positive gynecological cancers visible on PET was selected for this study. Prescribed dose varied between 45–50.4Gy, with a 55–70Gy boost to the PET positive nodes. A baseline and intratreatment (between 30–36Gy) PET-CT were obtained on a Siemens Biograph mCT. Each clinical PET image set was reconstructed 6 times using a TrueX+TOF algorithm with varying iterations and Gaussian filter. Baseline and intra-treatment primary GTVs were segmented using PET Edge (MIM Software Inc., Cleveland, OH), a semi-automatic gradient-based algorithm, on the clinical PET and transferred to the other reconstructed sets. Using an in-house MATLAB program, four 3D texture matrices describing relationships between voxel intensities in the GTV were generated: co-occurrence, run length, size zone, and neighborhood difference. From these, 39 textural features characterizing texture were calculated in addition to SUV histogram features. The percent variability among parameters was first calculated. Each reconstructed texture feature from baseline and intra-treatment per patient was normalized to the clinical baseline scan and compared using the Wilcoxon signed-rank test in order to isolate variations due to reconstruction parameters. Results: For the baseline scans, 13 texture features showed a mean range greater than 10%. For the intra scans, 28 texture features showed a mean range greater than 10%. Comparing baseline to intra scans, 25 texture features showed p <0.05. Conclusion: Variability due to different reconstruction parameters increased with treatment, however, the majority of texture features showed significant changes during treatment independent of reconstruction effects.
Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.
Purpose: Optically-stimulated luminescent dosimeters (OSLDs) are increasingly utilized for in vivo dosimetry of complex radiation delivery techniques such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Evaluation of clinical uncertainties such as placement error has not been performed. This work retrospectively investigates the magnitude of placement error using conebeam computed tomography (CBCT) and its effect on measured/planned dose agreement. Methods: Each OSLD was placed at a physicist-designated location on the patient surface on a weekly basis. The location was given in terms of a gantry angle and two-dimensional offset from central axis. The OSLDs were placed before daily image guidance. We identified 77 CBCTs from 25 head-and-neck patients who received IMRT or VMAT, where OSLDs were visible on the CT image. Grossly misplaced OSLDs were excluded (e.g. wrong laterality). CBCTs were registered with the treatment plan and the distance between the planned and actual OSLD location was calculated in two dimensions in the beam’s eye view. Distances were correlated with measured/planned dose percent differences. Results: OSLDs were grossly misplaced for 5 CBCTs (6.4%). For the remaining 72 CBCTs, average placement error was 7.0±6.0 mm. These errors were not correlated with measured/planned dose percent differences (R{sup 2}=0.0153). Generalizing the dosimetric effect of placement errors may be unreliable. Conclusion: Correct placement of OSLDs for IMRT and VMAT treatments is critical to accurate and precise in vivo dosimetry. Small placement errors could produce large disagreement between measured and planned dose. Further work includes expansion to other treatment sites, examination of planned dose at the actual point of OSLD placement, and the influence of imageguided shifts on measured/planned dose agreement.
Purpose: The goal of this study was to evaluate the repeatability of radiomics features (intensity, shape and heterogeneity) in both PET and low-dose CT components of test-retest FDG-PET/CT images in a prospective multicenter cohort of 74 NSCLC patients from ACRIN 6678 and a similar Merck trial. Methods: Seventy-four patients with stage III-IV NCSLC were prospectively included. The primary tumor and up to 3 additional lesions per patient were analyzed. The Fuzzy Locally Adaptive Bayesian algorithm was used to automatically delineate metabolically active volume (MAV) in PET. The 3D SlicerTM software was exploited to delineate anatomical volumes (AV) in CT. Ten intensity first-order features, as well as 26 textural features and four 3D shape descriptors were calculated from tumour volumes in both modalities. The repeatability of each metric was assessed by Bland-Altman analysis. Results: One hundred and five lesions (primary tumors and nodal or distant metastases) were delineated and characterized. The MAV and AV determination had a repeatability of −1.4±11.0% and −1.2±18.7% respectively. Several shape and heterogeneity features were found to be highly or moderately repeatable (e.g., sphericity, co-occurrence entropy or intensity size-zone matrix zone percentage), whereas others were confirmed as unreliable with much higher variability (more than twice that of the corresponding volume determination). Conclusion: Our results in this large multicenter cohort with more than 100 measurements confirm the PET findings in previous studies (with <30 lesions). In addition, our study is the first to explore the repeatability of radiomics features in the low-dose CT component of PET/CT acquisitions (previous studies considered dosimetry CT, CE-CT or CBCT). Several features were identified as reliable in both PET and CT components and could be used to build prognostic models. This work has received a French government support granted to the CominLabs excellence laboratory and managed by the National Research Agency in the “Investing for the Future” program under reference ANR-10-LABX-07-01, and support from the city of Brest.
ABSTRACT Mucoromycota fungi and their Mollicutes-related endobacteria (MRE) are an ideal system for studying bacterial–fungal interactions and evolution due to the long-term and intimate nature of their interactions. However, methods for detecting MRE face specific challenges due to the poor representation of MRE in sequencing databases coupled with the high sequence divergence of their genomes, making traditional similarity searches unreliable. This has precluded estimations on the diversity of MRE associated with Mucoromycota. To determine the prevalence of previously undetected MRE in fungal genome sequences, we scanned 389 Mucoromycota genome assemblies available from the National Center for Biotechnology Information for the presence of MRE sequences using publicly available tools to map contigs from fungal assemblies to publicly available MRE genomes. We demonstrate a higher diversity of MRE genomes than previously described in Mucoromycota and a lack of cophylogeny between MRE and the majority of their fungal hosts. This supports the late invasion hypothesis regarding MRE acquisition across most of the examined fungal families. In contrast with other Mucoromycota lineages, MRE from the Gigasporaceae displayed some degree of cophylogeny with their hosts, which may indicate that horizontal transmission is restricted between members of this family or that transmission is strictly vertical. These results underscore the need for a refined process to capture sequencing data from potential fungal endosymbionts to discern their evolution and transmission. Screens of fungal genomes for MRE can help improve the quality of fungal genome assemblies while identifying new MRE lineages to further test hypotheses on their origin and evolution. IMPORTANCE Mollicutes-related endobacteria (MRE) are obligate intracellular bacteria found within Mucoromycota fungi. Despite their frequent detection, MRE roles in host functioning are still unknown. Comparative genomic investigations can improve our understanding of the impact of MRE on their fungal hosts by identifying similarities and differences in MRE genome evolution. However, MRE genomes have only been assembled from a small fraction of Mucoromycota hosts. Here, we demonstrate that MRE can be present yet undetected in publicly available Mucoromycota genome assemblies. We use these newfound sequences to assess the broader diversity of MRE and their phylogenetic relationships with respect to their hosts. We demonstrate that publicly available tools can be used to extract novel MRE sequences from assembled fungal genomes leading to insights on MRE evolution. This work contributes to a greater understanding of the fungal microbiome, which is crucial to improving knowledge on the dynamics and impacts of fungi in microbial ecosystems.
Using the Auger mass-composition analysis of ultra high energy cosmic rays, based on the shape-fitting of X{sub max} distributions [1], we demonstrate that mass composition and energy spectra measured by Auger, Telescope Array and HiRes can be brought into good agreement. The shape-fitting analysis of X{sub max} distributions shows that the measured sum of proton and Helium fractions, for some hadronic-interaction models, can saturate the total flux. Such p + He model, with small admixture of other light nuclei, naturally follows from cosmology with recombination and reheating phases. The most radical assumption of the presented model is the assumed unreliability of the experimental separation of Helium and protons, which allows to consider He/p ratio as a free parameter. The results presented here show that the models with dominant p + He composition explain well the energy spectrum of the dip in the latest (2015–2017) data of Auger and Telescope Array, but have some tension at the highest energies with the expected Greisen–Zatsepin–Kuzmin cutoff. The Auger-Prime upgrade experiment has a great potential to reject or confirm this model.
In addition to the results obtained earlier for the isotopes {sup 188,189}Os, experimental data on the photodisintegration of the isotopes {sup 186,190,192}Os are analyzed on the basis of specially introduced objective criteria of reliability of data on the cross sections for partial photoneutron reactions. It is found that the (γ, 1n), (γ, 2n), and (γ, 3n) cross sections for each isotope satisfy differently or, on the contrary, do not satisfy the data-reliability criteria. In many cases, the multiplicity transition functions specified as the ratios F{sub i} = σ(γ, in)/σ(γ, xn) of the cross sections for the (γ, in) partial reactions to the neutron-yield reaction cross section σ(γ, xn) = σ(γ, 1n) + 2σ(γ, 2n) + 3σ(γ, 3n) +... have values that are physically unreliable by definition. It is shown that ambiguities in the dependence of significant systematic uncertainties in experimentally determined neutron multiplicities on the measured kinetic energies is the reason for this. The dependence of these uncertainties on the energy spectra of neutrons is analyzed. For the isotopes {sup 186,190,192}Os, new evaluated data satisfying the data-reliability criteria are obtained for the cross sections for partial and total photoneutron reactions.
With the aid of the results obtained by evaluating cross sections of partial photoneutron reactions on the isotope {sup 116}Sn and the energy spectra of neutrons originating from these reactions, the possible reasons for the well-known discrepancies between the results of different photonuclear experiments were studied on the basis of a combinedmodel of photonuclear reactions. On the basis of physical criteria of data reliability and an experimental–theoretical method for evaluating cross sections of partial reactions, it was found that these discrepancies were due to unreliably redistributing neutrons between (γ, 1n), (γ, 2n), and (γ, 3n) reactions because of nontrivial correlations between the experimentally measured energy of neutrons and their multiplicity.
The causes and mechanisms of variation in the quantum efficiency and other characteristics of InGaN/GaN heterostructures are actively investigated in various operating modes. The results are presented from an experimental study of the variation in the external quantum efficiency of low-power InGaN/GaN green light-emitting diodes with and without a quantum well in the space–charge region (SCR) of the heterostructure in the accelerated test mode. It is found that after 8 hours of testing at a temperature of 300 K in the pulse mode with a pulse amplitude of 0.5 A, a pulse duration of 100 µs, and a duty cycle of 100, the external quantum efficiency grows for all LEDs without a quantum well in the SCR and diminishes for LEDs with a quantum well throughout the range of operating currents. It is shown that at a low level of injection, the intensity of emission of light emitting diodes without a quantum well in the SCR is determined by recombination processes according to the Shockley–Read–Hall mechanism, while that of LEDs with a quantum well is determined by tunneling–recombination processes. Current training of green LEDs based on InGaN/GaN heterostructures in the forced pulse mode for 4 hours can be used as a technological operation for stabilizing their lighting characteristics, and for identifying potentially unreliable products under conditions of mass production.
Moving scientific computation from high-performance computing (HPC) and cloud computing (CC) environments to devices on the edge, i.e., physically near instruments of interest, has received tremendous interest in recent years. Such edge computing environments can operate on data in situ, offering enticing benefits over data aggregation to HPC and CC facilities that include avoiding costs of transmission, increased data privacy, and real-time data analysis. Because of the inherent unreliability of edge computing environments, new fault-tolerant approaches must be developed before the benefits of edge computing can be realized. Motivated by algorithm-based fault tolerance, a variant of the asynchronous Jacobi (ASJ) method is developed that achieves resilience to data corruption by rejecting solution approximations from neighbor devices according to a bound derived from convergence theory. Numerical results on a two-dimensional Poisson problem show that the new rejection criterion, along with a novel approximation to the shortest path length on which the criterion depends, restores convergence for the ASJ variant in the presence of certain types data corruption. Numerical results are obtained for when the singular values in the analytic bound are approximated. Additional linear systems are also explored, one with a more dense sparsity pattern and one that includes advection. All results indicate that successful resilience to data corruption depends on whether the bound tightens fast enough to reject corrupted data before the iteration evolution deviates significantly from that predicted by the convergence theory defining the bound. This observation generalizes to future work on algorithm-based fault tolerance for other asynchronous algorithms, including upcoming approaches that leverage Krylov subspaces.