Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “traceable calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

338 records · Page 19

Response of TLD-100 in mixed fields of photons and electrons

Purpose: Thermoluminescent dosimeters (TLDs) are routinely used for dosimetric measurements of high energy photon and electron fields. However, TLD response in combined fields of photon and electron beam qualities has not been characterized. This work investigates the response of TLD-100 (LiF:Mg,Ti) to sequential irradiation by high-energy photon and electron beam qualities. Methods: TLDs were irradiated to a known dose by a linear accelerator with a 6 MV photon beam, a 6 MeV electron beam, and a NIST-traceable {sup 60}Co beam. TLDs were also irradiated in a mixed field of the 6 MeV electron beam and the 6 MV photon beam. The average TLD response per unit dose of the TLDs for each linac beam quality was normalized to the average response per unit dose of the TLDs irradiated by the {sup 60}Co beam. Irradiations were performed in water and in a Virtual Water Trade-Mark-Sign phantom. The 6 MV photon beam and 6 MeV electron beam were used to create dose calibration curves relating TLD response to absorbed dose to water, which were applied to the TLDs irradiated in the mixed field. Results: TLD relative response per unit dose in the mixed field was less sensitive than the relative response in the photon field and more sensitive than the relative response in the electron field. Application of the photon dose calibration curve to the TLDs irradiated in a mixed field resulted in an underestimation of the delivered dose, while application of the electron dose calibration curve resulted in an overestimation of the dose. Conclusions: The relative response of TLD-100 in mixed fields fell between the relative response in the photon-only and electron-only fields. TLD-100 dosimetry of mixed fields must account for this intermediate response to minimize the estimation errors associated with calibration factors obtained from a single beam quality.

60 APPLIED LIFE SCIENCES↗

Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

Markham, Brian↗

Evaluation of Spectral Band Adjustment Factors for Cross-Calibration of Visible Imagers

The NASA CERES EBAF dataset provides TOA SW and LW fluxes for long-term monitoring of the Earth’s energy balance and to validate climate models. The EBAF products, based on the Terra, Aqua, and NOAA20 CERES instrument observed radiances, rely on coincident measurements from the onboard MODIS or VIIRS imagers to determine cloud properties used for angular distribution model scene selection, which is required to convert the CERES observed radiances into flux values. Furthermore, CERES utilizes geostationary imager (GEO) hourly fluxes and clouds to infer the regional averaged daily flux in the SYN1deg product. A seamless transition of fluxes and clouds can only occur if the analogous MODIS, VIIRS, and GEO channels are properly inter-calibrated. The analogous band SRFs differ noticeably and require scene dependent spectral band adjustment factors (SBAF) for proper radiometric scaling between them. Given their disparate but overlapping SRFs, the coincident VIIRS I1 and M5 band TOA reflectance measurements provide the optimal opportunity to validate SBAFs over many surface and cloud conditions. The CERES project maintains SCIAMACHY, GOME-2, and Hyperion scene-stratified hyper-spectral reflectance measurements that can be convolved with sensor pair SRFs to compute the corresponding SBAF. This study highlights the SCIAMACHY, GOME-2, and Hyperion based SBAFs for different MODIS, VIIRS, and GEO inter-calibration targets, including all-sky tropical ocean (ATO), Libya-4, Dome-C, and deep convective clouds. To mitigate the observed sensor radiance fluctuations due to atmospheric absorption and aerosol variations, the Earth target observed radiances are correlated with multiple atmospheric parameters, such as precipitable water and ozone. The remaining M5 and I1 mean spectral band radiance difference should be resolved by the SBAF correction. The formulation of hyper-spectral sensor based SBAFs and validation methods can be verified in future utilizing high-accuracy, SI-traceable hyper-spectral measurements from CLARREO Pathfinder.

David R Doelling↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Current Developments in Future Planetary Probe Sensors for TPS

In-situ Thermal Protection System (TPS) sensors are required to provide traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the development of a microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor will be monolithic solid state devices composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500 K, and allowable constant heat flux of q=28.7 watts per square centimeter, and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture. This paper also reports on progress to adapt a previously flown surface recession sensor, based on the Jupiter probe Galileo Analog Resistance Ablation Detector (ARAD), to appropriate aerocapture conditions.

Martinez, Ed↗

Development of Solid State Thermal Sensors for Aeroshell TPS Flight Applications

In-situ Thermal Protection System (TPS) sensors are required to provide verification by traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the continuing development of a thermal microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor is a monolithic solid state device composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500K, and allowable constant heat flux of q=28.7 W/cm(sup 2), and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture.

Martinez, Ed↗

Critical Need for Plutonium and Uranium Isotopic Standards with Lower Uncertainties

Certified reference materials (CRMs) traceable to national and international safeguards database are a critical prerequisite for ensuring that nuclear measurement systems are free of systematic biases. CRMs are used to validate measurement processes associated with nuclear analytical laboratories. Diverse areas related to nuclear safeguards are impacted by the quality of the CRM standards available to analytical laboratories. These include: nuclear forensics, radio-chronometry, national and international safeguards, stockpile stewardship, nuclear weapons infrastructure and nonproliferation, fuel fabrication, waste processing, radiation protection, and environmental monitoring. For the past three decades the nuclear community is confronted with the strange situation that improvements in measurement data quality resulting from the improved accuracy and precision achievable with modern multi-collector mass spectrometers could not be fully exploited due to large uncertainties associated with CRMs available from New Brunswick Laboratory (NBL) that are used for instrument calibration and measurement control. Similar conditions prevail for both plutonium and uranium isotopic standards and for impurity element standards in uranium matrices. Herein, the current status of U and Pu isotopic standards available from NBL is reviewed. Critical areas requiring improvement in the quality of the nuclear standards to enable the U. S. and international safeguards community to utilize the full potential of modern multi-collector mass spectrometer instruments are highlighted.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

CLARREO Pathfinder (Cpf) State-of-the-Art Intercalibration Capabilities

NASA's Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission will deploy an Earth-observing reflected solar (RS) spectrometer, designed to measure Earth-reflected solar radiation from the International Space Station with a remarkable SI-traceable radiometric uncertainty of 0.3%-0.6% (k=1). The high-accuracy CPF measurements will provide an on-orbit reference for intercalibrating other spaceflight RS instruments. The CPF intercalibration team will showcase an innovative on-orbit intercalibration approach, wherein two other RS sensors—the shortwave (SW) channel of the Clouds and the Earth’s Radiant Energy System (CERES) and the Reflective Solar Bands (RSB) of the Visible Infrared Imager Radiometer Suite (VIIRS)—are intercalibrated against CPF benchmark measurements, with an unprecedented intercalibration methodology uncertainty of 0.3% (k=1).

climate↗

Hyperspectral Detail Meets Radiometric Accuracy: A Foundational Reflected Solar Capability for the Coming Decade

Hyperspectral Earth-reflected solar measurements contain rich, detailed information about clouds, aerosols, and the atmosphere. This information compounds when paired with high, SI-traceable radiometric accuracy. Unlike spectral resolution, which can be resampled to coarser spectral resolutions, radiometric accuracy cannot be recovered once a measurement is made, making the choice to invest in this capability now a decision with lasting consequences for the climate record. CLARREO Pathfinder is demonstrating that this combination of hyperspectral sampling and benchmark-quality accuracy is achievable today, but no follow-on mission is currently planned within NASA's Earth Science Division portfolio, and the recent cancellation of the European Space Agency TRUTHS mission has heightened the urgency of sustaining this capability. We recommend prioritizing investment in a follow-on to CLARREO Pathfinder, along with dedicated support for the science community to fully exploit these measurements. This capability would reduce long-standing uncertainties in cloud feedback, aerosol forcing, and global energy imbalance, while providing a degradation-resistant, gap-resilient calibration foundation for the broader Earth observing system. Building on flight-proven technology and an engaged science community, this is a near-term, fiscally realistic opportunity to secure a foundational Earth observation capability for the coming decade.

satellite↗

Laboratory-Based BRDF Calibration of Radiometric Tarps

The current study provides the remote sensing community with important high accuracy laboratory-based BRDF calibration of radiometric tarps. The results illustrate the dependence of tarps' weft and warp threads orientation on BRDF. The study was done at incident angles of 0deg, 10deg, and 30deg; scatter zenith angles from 0deg to 60deg, and scatter azimuth angles of 0deg, 45deg, 90deg, 135deg, and 180deg. The wavelengths were 485nm, 550nm, 633nm and 800nm. The dependence is well defined at all measurement geometries and wavelengths. It can be as high as 8% at 0deg incident angle and 2% at 30deg incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps is reported. The backward scatter is well pronounced for the white samples. The black sample has well pronounced forward scatter. The BRDF characterization of radiometric tarps can be successfully extended to other structured surface fabric samples. The results are NIST traceable.

Georgiev, Georgi T.↗

Comparison of the Davies and Gray titrimetric method with potassium dichromate and ceric titrants

The modified New Brunswick Laboratory (NBL) Davies and Gray titrimetry method uses potassium dichromate standard 136-f from the National Institute of Standards and Technology for calibration. However, the presence of chromium in the resulting waste stream makes the disposal of waste from this procedure costly. We report that the Actinide Analytical Chemistry (C-AAC) group at Los Alamos National Laboratory investigated and transitioned to a cerium based titrant as an alternative. We present the first long-term analytical study using this ceric-based titration method and compare it with NBL results based on the more-widely used dichromate titrimetric method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Prelaunch Spectral Characterization of the Operational Land Imager-2

The Landsat-9 satellite, launched in September 2021, carries the Operational Land Imager-2 (OLI-2) as one of its payloads. This instrument is a clone of the Landsat-8 OLI and its mission is to continue the operational land imaging of the Landsat program. The OLI-2 instrument is not significantly different from OLI though the instrument-level pre-launch spectral characterization process was much improved. The focal plane modules used on OLI-2 were manufactured as spares for OLI and much of the spectral characterization of the components was performed for OLI. However, while the spectral response of the fully assembled OLI was characterized by a double monochromator system, the OLI-2 spectral characterization made use of the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR is a system of tunable lasers that cover 350–2500 nm which are fiber-coupled to a 30 in integrating sphere permanently monitored by NIST-traceable radiometers. GLAMR allowed the spectral characterization of every detector of the OLI-2 focal plane in nominal imaging conditions. The spectral performance of the OLI-2 was, in general, much better than requirements. The final relative spectral responses (RSRs) represent the best characterization any Landsat instrument spectral response. This paper will cover the results of the spectral characterization from the component-level to the instrument-level of the Landsat-9 OLI-2.

Landsat-9↗

National Renewable Energy Laboratory Pyrheliometer Comparisons: 24 September - 5 October 2012 (NPC-2012)

The NREL Pyrheliometer Comparisons for 2012 (NPC-2012) were held at the Solar Radiation Research Laboratory in Golden, Colorado, from September 24 through October 5 for the purpose of transferring the World Radiometric Reference (WRR) to participating instrument. Twenty scientists and engineers operated 32 absolute cavity radiometers and 18 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky direct normal irradiance during the comparisons. The transfer standard group of reference radiometers for NPC-2012 consisted of four NREL radiometers with direct traceability to the WRR, having participated in the Eleventh International Pyrheliometer Comparisons (IPC-XI) hosted by the World Radiation Center in the fall of 2010. As the result of NPC-2012, each participating absolute cavity radiometer was assigned a new WRR transfer factor, computed as the reference irradiance computed by the transfer standard group divided by the observed irradiance from the participating radiometer. The performance of the transfer standard group during NPC-2012 was consistent with previous comparisons, including IPC-XI. The measurement performance of the transfer standard group allowed the transfer of the WRR to each participating radiometer with an estimated uncertainty of +/- 0.33% with respect to the International System of Units.

14 SOLAR ENERGY↗

Surrogate Post-Detonation Urban Debris (SPUD): Standard Reference Materials 4600 and 4601

If a terrorist nuclear explosion were to occur in the United States, high-quality (accurate and precise) legally defensible nuclear forensics measurements will be required to assure the certainty and confidence needed, for conclusions drawn from these data will be coupled with law enforcement and intelligence information for the purposes of attribution and retribution. Standard Reference Materials (SRMs)/Certified Reference Materials (CRMs) establish the traceability, accuracy, and precision of nuclear forensic measurements and provide the ability to benchmark measurement methods essential to meeting the requirements of legal scrutiny. Currently there is a critical shortage of key SRMs/CRMs required for accurate and precise measurements that are fundamental to nuclear measurements supporting pre- and post-detonation nuclear forensics. Supplies either do not exist, are not good enough, are in short supply, and/or are very expensive. The radionuclide measurement techniques and data quality objectives for pre- and post-detonation nuclear forensics are quite different than the applications for which the current suite of available SRMs/CRMs was developed. Specifically, 1) modern mass spectrometry methods have largely replaced traditional activity-based measurement methods for quantifying small quantities of long-lived radionuclides and most trace radionuclide SRMs/CRMs are certified for activity and are thus not adequate for current applications, 2) modern instrumental methods are capable of higher precision than historic measurement techniques, and in some cases exceed the precision of the available SRMs/CRMs, and 3) the quality assurance requirements for pre- and post-detonation nuclear forensics are such that the existing cadre of SRMs/CRMs does not adequately support the needs for method validation. There are numerous governmental stakeholders both within the US (DOE, DoD) and internationally (IAEA, JRC-ITU) whose missions are either directly involved with nuclear forensics measurements or rely on the forensic data obtained to make the exacting policy decisions (DOJ (FBI), DHS, CIA, DIA, DoD) associated with disrupting the production of illicit nuclear materials, interdicted nuclear materials or a nuclear/radiological detonation event. Starting in 2008 the DHS NTNFC, in collaboration with NBL and NIST, took on the production of suitable SRMs/CRMs for the pre-detonation nuclear forensics community. Two CRMs have been released since the start of this effort and two more are slated for completion in 2016. More recently, NIST, as a part of its mission as the US National Metrology Institute (NMI) to deliver standards (providing traceability) and foster homeland security, has launched the first certification campaign of a measurement traceable post nuclear detonation SRM. NIST, in cooperation with partner labs (AFIT (DoD), FBI (DOJ), and NPL) and with support from the FBI, has developed two Surrogate Post-Detonation Urban Debris (SPUD) Standard Reference Materials (SRMs) - SRM 4600 and 4601. These SRMs have been developed to simulate the expected debris mixture from the detonation of an Improvised Nuclear Device (IND) in an urban environment, which is capable of producing fresh fission as well as activation products. The elemental composition of the vitrified debris materials is a composite of minerals and metals characteristic of the concrete and steel, the building materials that would be exposed to a nuclear detonation and whose resulting activation products would be found in rubble samples collected for forensics evidence and attribution. Additionally, because post-detonation samples would also contain short-lived fission products, the debris materials have been doped with Uranium (U). To create the nuclear fission products, samples of the SPUD materials can be placed in a well-characterized nuclear reactor and exposed to a set neutron flux and energy, causing the encased U atoms to split and yield short-lived fission products. Because a known amount of U is added to the SPUD materials it is feasible to determine the concentration of the resulting fission products. The subsequent irradiated SPUD glass would be chemically similar to samples that would be generated in an actual detonation, and thus can serve as a standardized reference material for nuclear forensic post detonation measurements. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗