Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons

A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. Here we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (~30 J energy, ~10 21 W/cm 2 intensity, ~30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.

47 OTHER INSTRUMENTATION↗

Charged Current Coherent Pion Production Cross-Section Measurement at MicroBooNE

Coherent pion production, characterized by a neutrino interacting with an entire nucleus without breaking it apart, results in a forward-going muon, pion, and a low-momentum recoil nucleus. By leveraging an improved understanding of particle identification and background parameterization, we aim to achieve a new level of sensitivity to coherent interactions at low neutrino energy. The outcome of this analysis will contribute to ongoing efforts to model neutrino nucleus interactions accurately in neutrino oscillation studies and beyond Standard Model searches in MicroBooNE and future experiments, such as DUNE. We present progress towards a measurement of charged current coherent pion production cross-section on argon with the MicroBooNE liquid argon time projection chamber detector. This measurement will use MicroBooNE's full dataset collected from the Booster Neutrino Beam with a total exposure of \( 1.3 \times 10^{21} \) protons-on-target and average neutrino energy of 0.8 GeV.

Hussain, Adil [Kansas State U.]↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Probing BSM Oscillatory Signals with the DUNE Detectors and the LBNF Neutrino Beam: NSI and Sterile Neutrino Sensitivities

The Deep Underground Neutrino Experiment (DUNE) is a flagship long-baseline accelerator neutrino experiment under construction in the U.S. With a 1,300 km distance between its Near Detector (ND) and Far Detector (FD), the world’s most intense LBNF (Long-Baseline Neutrino Facility) neutrino beam, and high-resolution LArTPC (Liquid Argon Time Projection Chamber) detectors, DUNE will measure the neutrino oscillation parameters with unprecedented precision. In addition to the determination of the neutrino mass ordering and the potential discovery of Charge-Parity violation in the leptonic sector, DUNE's capabilities present a unique opportunity for probing Beyond the Standard Model (BSM) physics signals with neutrinos. Examples of BSM physics manifestations include the presence of Non-Standard Interactions (NSI) of neutrinos with matter, or the existence of sterile neutrinos that mix with 3-Flavor neutrinos. In this study, we present a joint ND+FD fit to simulated data assessing DUNE's sensitivity to probing neutrino NSI, as well as scenarios including sterile neutrino mixing.

Prais, Luiz [Cincinnati U.] (ORCID:000000018224947↗

Experimental study of the space-time development of the particle production process in hadron-nucleon collisions, using massive target nucleus as a detector

Experimental study of the space-time development of the particle production process in hadronic collisions at its initial stage was performed. Massive target nuclei have been used as fine detectors of properties of the particle production process development within time intervals smaller than 10 to the 22nd power s and spatial distances smaller than 10 to the 12th power cm. In hadron-nucleon collisions, in particular in nucleon-nucleon collisions, the particle production process goes through intermediate objects in 2 yields 2 type endoergic reactions. The objects decay into commonly observed resonances and paricles.

Strugalski, Z.↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulsed multiwavelength laser ranging system for measuring atmospheric delay

A multiwavelength laser ranging system has been designed for measuring atmospheric path delay in satellite laser ranging systems. The instrument measures the difference between the propagation times of 532 and 355 nm pulses as a measure of integrated air density. The present design uses a frequency-tripled dye mode-locked Nd:YAG laser as a pulse source and subnanosecond response time photomultipliers as detectors. Studies indicate that recovery of the atmospheric path delay in satellite ranging to the 1-cm level will require the differential arrival time measurements with an accuracy of 3-7 ps. Initial horizontal path test results are presented.

Abshire, J. B.↗

Mass reconstruction of heavy neutral leptons from stopped mesons

Heavy neutral leptons (HNLs), depending on their mass and mixing, can be efficiently produced in meson decays from the target or absorber in short- to medium-baseline accelerator neutrino experiments, leaving detectable signals through their decays inside the neutrino detectors. We show that the currently running ICARUS experiment at Fermilab can reconstruct the HNL mass and explore new HNL parameter space in the mass range of 70–190 MeV. The mass reconstruction is enabled by two ingredients: (i) simple two-body kinematics of HNL production from stopped kaon decays at the NuMI absorber, followed by HNL decay into a charged-lepton pair and neutrino at the detector, and (ii) high resolution of Liquid Argon Time Projection Chamber (LArTPC) detectors in reconstructing final state particles. Our mass reconstruction method is robust under realistic energy resolution and angular smearing of the charged leptons, and is applicable to any LArTPC detector. We also discuss the synergy between ICARUS and future facilities like DUNE near detector and PIP-II beam dump in probing the HNL parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response. The ability to rapidly obtain a flat-field response allows for recalibration of an X-ray detector as needed without significant expenditure of either time or effort. Area detectors on the beamlines used, such as the Pilatus 2M CdTe, PE XRD1621 and Varex XRD 4343CT, were found to have detector responses that drift slightly over timescales of several weeks or after exposure to high photon flux, suggesting the need to more frequently recalibrate with a new flat-field correction map.

47 OTHER INSTRUMENTATION↗

NUMI Flux Systematic Uncertainties

The Imaging Cosmic And Rare Underground Signals (ICARUS) detector is a 476 t active liquid argon time projection chamber neutrino detector at Fermilab. ICARUS lies 795 m downstream and 5.75◦ off-axis from the Neutrinos at the Main Injector (NuMI) beam. To create a neutrino beam NuMI directs pulsed beam of 120 GeV protons onto a graphite target to create hadrons, which are then focused by magnetic horns and allowed to decay into neutrinos. At the ICARUS off-axis angle the neutrino flux originates from the decays of unfocused/antifocused pions decays and from high-transverse momentum kaon decays. These contributions allow ICARUS to observe a significant flux of (anti-)electron and (anti-)muon neutrinos in a kinematic region relevant to the upcoming DUNE experiment. These factors also introduce various model uncertainties that have not been studied in detail by existing on-axis experiments. This poster will explore the systematic uncertainties in the NuMI flux at ICARUS that arise from uncertainties on hadron interaction cross sections and beamline operation conditions.

Alrahman, Fatima Abd [Houston U.]↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Archiving data from ground-based telescopes

The scientific throughput of a particular observing facility has been demonstrated to be multiplied with the operation of a data archive and its corresponding retrieval system. A requisite to achieve such an exploitation is a well structured observations catalog, i.e. a catalog that includes all information necessary to reduce and analyze the data even many years after its acquisition. At the same time, an information system is required that allow users to browse through the catalog at different levels of detail, adapting the amount of information presented to the actual needs of the user. Archiving data acquired with ground-based telescopes is particularly difficult because of the relative short life-time of instruments and detectors in comparison to the expected life-time of the archive. This feature differentiates ground-based originated archives radically from its spaceborne counterparts. The organization of the observations catalog becomes highly dependent on the capability of the archive to deal with new instrumental configurations. We introduce in this paper, the concept of a catalog database as opposed to the static catalog design currently in use in many archiving facilities, as a method to deal with this problem. We also present a brief review of activities currently in progress in this area.

Albrecht, M. A.↗

Enhanced Imaging of Corrosion in Aircraft Structures with Reverse Geometry X-ray(registered tm)

The application of Reverse Geometry X-ray to the detection and characterization of corrosion in aircraft structures is presented. Reverse Geometry X-ray is a unique system that utilizes an electronically scanned x-ray source and a discrete detector for real time radiographic imaging of a structure. The scanned source system has several advantages when compared to conventional radiography. First, the discrete x-ray detector can be miniaturized and easily positioned inside a complex structure (such as an aircraft wing) enabling images of each surface of the structure to be obtained separately. Second, using a measurement configuration with multiple detectors enables the simultaneous acquisition of data from several different perspectives without moving the structure or the measurement system. This provides a means for locating the position of flaws and enhances separation of features at the surface from features inside the structure. Data is presented on aircraft specimens with corrosion in the lap joint. Advanced laminographic imaging techniques utilizing data from multiple detectors are demonstrated to be capable of separating surface features from corrosion in the lap joint and locating the corrosion in multilayer structures. Results of this technique are compared to computed tomography cross sections obtained from a microfocus x-ray tomography system. A method is presented for calibration of the detectors of the Reverse Geometry X-ray system to enable quantification of the corrosion to within 2%.

Winfree, William P.↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗