Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dynamic STEM-EELS for single-atom and defect measurement during electron beam transformations

This study introduces the integration of dynamic computer vision–enabled imaging with electron energy loss spectroscopy (EELS) in scanning transmission electron microscopy (STEM). This approach involves real-time discovery and analysis of atomic structures as they form, allowing us to observe the evolution of material properties at the atomic level, capturing transient states traditional techniques often miss. Rapid object detection and action system enhances the efficiency and accuracy of STEM-EELS by autonomously identifying and targeting only areas of interest. This machine learning (ML)–based approach differs from classical ML in that it must be executed on the fly, not using static data. We apply this technology to V-doped MoS 2 , uncovering insights into defect formation and evolution under electron beam exposure. This approach opens uncharted avenues for exploring and characterizing materials in dynamic states, offering a pathway to increase our understanding of dynamic phenomena in materials under thermal, chemical, and beam stimuli.

47 OTHER INSTRUMENTATION↗

Developing Separate Effects Transient Test Experiments Using an Out-of-Pile Flowing Water Loop

In 2017 the Transient Reactor Test Facility was restarted after being placed in a standby state since 1994. This Test Reactor’s restart has since enabled the progressive development of new nuclear technologies within the U.S. that were previously required to outsource to other countries. While the reactor’s restart was a large feat worthy of recognition, the experimental use of its characteristics has required the further development of in-pile experimental infrastructure sufficient to support programmatic needs. This hardware have taken the form of capsule designs (compact and elongated) as well as loop concepts representing the phenomena of interest for a subset of separate effects tests desire for each respective testing campaign. The Transient Testing Program has a large-integrated effort that aligns with the U.S. Department of Energy’s current needs. This study compliments those programmatic elements by developing, fabricating and demonstrating a full-scale flowing water loop in an out-of-pile environment. The goal of this effort is to develop a pragmatic understanding of the engineering capabilities and limitations associated with geometric form-factors, metering technology, and controls logic under representative thermal hydraulic conditions that would be experienced within the TREAT reactor during an in-pile reactivity initiated accident test. The outcomes of this study result in an evaluation of the conceptual design of a comprehensive flowing water loop including objective figures of merit (FoMs) for comparing unique instrumentation and the basis for their selection during operations. These efforts directly contribute to and are required for the further advancement of transient testing capabilities within the U.S.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Hazardous Gases from NMC811 Materials and Coin Cells with TGA and Tube-Furnace FTIR-MS Evolved-Gas-Analysis

Abuse testing is useful for informing the risks of different battery chemistries but has been limited to larger formats. This paper conducted thermal abuse tests at the smaller coin cell level to determine its relevance in specifying vent gas flammability and toxicity. A nitrogen purge carried the evolved gases into a parallel Fourier-transform infrared spectrometer (FTIR) and a mass spectrometer (MS) downstream of the tube furnace. The experimental system was validated by comparing evolved gas data for single components between the tube furnace system and a thermogravimetric analysis (TGA) instrument. Multiple samples were tested during validation, including CaCO3, electrolyte, delithiated NMC 811 cathode, and lithiated graphite anode. Temperature-resolved gas evolution of HF, CO2, CO, H2, and hydrocarbons from isolated components helped to characterize the emission sources. A previously unreported H2 generation mechanism was found. It was shown that the reduced NMC cathode acts as a catalyst to crack polypropylene-decomposed hydrocarbons into H2 at around 450 degrees C. It was also shown, while studying LiPF6 thermal decomposition, that using the tube furnace with a coin cell casing as the sample holder has some advantages for evolved-gas analysis of environmentally sensitive samples relative to testing in TGA instruments. After validation with single components, a fully charged NMC 811 coin cell was failed in the tube furnace. The measured evolved gases were found to be a combination of the species measured from the single component tests. H2 formation related to the reduced cathode was found to have greater abundance than H2 formed from the anode. Hydrogen fluoride emission factors and diethyl carbonate conversion emission factors assist in understanding the gaseous hazards for larger format cells.

25 ENERGY STORAGE↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design of Temperature-Controlled Fueled-Salt Irradiation Experiment to Support Demonstration of Advanced Nuclear Reactors

The irradiation testing of fuel-bearing molten salts is critical to supporting the development and demonstration of molten salt reactors (MSRs). These experiments can inform several important reactor design and safety parameters, including source term modeling, evolution of thermophysical properties with burn-up, and the degradation of structural materials under reactor relevant conditions. Idaho National Laboratory is designing an instrumented and heated high temperature molten salt-fueled irradiation capsule to study the behavior of the fuel salt during in-pile irradiation. This paper details the neutronics, thermal, and mechanical analysis performed to-date. Parametric studies are performed to assess a range of material, different experiment dimensions, two in-reactor positions, and the fuel enrichment used. Principal recommendations are to opt for a peripheral reactor position to alleviate neutronic constraints, a thin salt annulus to alleviate thermal constraints, and high-temperature alloys that provide additional safety margins.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods, are disclosed. A representative method for forming a nuclear-powered steam generator includes forming an instrumented support, the instrumented support including a carrier portion and a retainer portion, with at least one of the carrier portion or the retainer portion being integrally formed with a sensor via an additive manufacturing process. The method can further include coupling the sensor to a communication link, supporting a helical steam conduit on the instrumented support, and installing the helical steam conduit and the instrumented support in a nuclear reactor. The helical steam conduit is positioned along a primary flow path, which is in turn positioned to circulate a heated primary flow in thermal communication with the helical steam conduit.

Welter, Kent↗

The Use of Long-wave Infrared Cameras for Hazardous Waste Remediation - 20457

For over fifty years, infrared cameras have been used in military applications, nondestructive testing, condition monitoring, and predictive maintenance. As infrared cameras continue to become more sophisticated and less expensive, they are providing value in an ever-increasing variety of unique applications, including hazardous waste remediation. This paper describes several instances of how infrared cameras have been used within the US Department of Defense and the US Department of Energy in support of waste remediation projects, including the author's recent use of an infrared camera in support of the Calcine Retrieval Project at the Idaho National Laboratory. Infrared cameras provide images of infrared radiation, or heat energy, which is otherwise invisible to the unaided eye. Infrared radiation is part of the electromagnetic spectrum, which includes visible light. But unlike visible light, infrared has wavelengths longer than the human eye can detect. Infrared is emitted by everything with a temperature above absolute zero (-273 deg. C, or -459 deg. F); the higher the temperature, the greater the infrared thermal radiation, or heat, that is emitted. Even objects that feel cold to us, like ice, emit thermal radiation and can be imaged by infrared cameras. These cameras are typically used to look for abnormally hot or cold spots on a component or target area under normal operating conditions. The method provides a rapid, wide-area, noncontact technique for identifying problems associated with a temperature differential. All infrared cameras can provide qualitative thermal information by displaying relative differences in temperatures within a two-dimensional image. More expensive infrared cameras can also provide quantitative information where an absolute temperature value is assigned to each pixel associated with the displayed two-dimensional image. Proper camera calibration and a solid understanding of heat transfer and thermography techniques are required when using an infrared camera to obtain quantitative information. Case studies outlined in this paper include the rapid, non-intrusive detection of hazardous decontamination solution within one-ton shipping containers at Pine Bluff Arsenal, the non-intrusive identification of residual elemental sodium within the cooling loops of the Experimental Breeder Reactor II (EBR-II) reactor at the Idaho National Laboratory, process monitoring of heat exchanger melt-and-drain efforts during EBR-II decommissioning, and the remote detection of internal steel supports within calcine storage bins prior to bin penetration. For each use of thermography, the author describes a summary of the waste remediation effort, the infrared camera used, the thermal imaging technique employed, and the results obtained. The paper concludes with a discussion on common mistakes to avoid for similar applications of thermography. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Out-of-Pile Test of LVDT-Based Creep Test Rig at PWR Prototypical Conditions

New and improved materials are being considered to support the existing nuclear reactors and future next-generation reactors. The materials can significantly degrade and limit their properties in harsh reactor environments. To accurately understand the material’s degradation, real-time data is required under prototypic-irradiation conditions. Additionally, understanding the creep behavior of materials under harsh environments is essential for an evaluation of safety concerns. To provide these capabilities, the Idaho National Laboratory’s (INL’s) High Temperature Test Laboratory (HTTL) has developed several instrumented test rigs to obtain real-time data from specimens in well-controlled pressurized water reactor (PWR) coolant conditions in the Materials and Test Reactors (MTRs). This technical report focuses on INL’s efforts to evaluate and enhance the former prototype creep test rig that relied on linear variable differential transformers in laboratory settings. Specifically, the test rig is capable of detecting changes in the length of tensile specimen, which is useful for measuring thermal expansion and creep loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Developing compact tuning fork thermometers for sub-mK temperatures and high magnetic fields

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. Here, we present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3 He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.

47 OTHER INSTRUMENTATION↗

Fire Modeling of a Facility for Combustible Loading

The purpose of this project was to create a fire model of the facility. Results from the model will be used to establish standoff distances from combustible fuel packages in the facility, in order to protect material from a thermal event.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Advanced Power Electronics Designs - Reliability and Prognostics (Keystone Project 1)

The primary deliverable for this project will be to construct a power electronics package utilizing an organic electrically insulating substrate material with a direct chip-to-chip interconnect technology and demonstrate superior thermal performance and greater reliability under thermal cycling, thermal aging, vibration, power cycling, and electrical high-potential evaluation over traditional packages.

47 OTHER INSTRUMENTATION↗

Influence of Combustion Gas Temperatures on Piston Deposits for Diesel and Ammonia Dual-Fuel Combustion

As new fuels are adopted for marine engines, it is necessary to understand their impact on lubricant performance. In order to evaluate the performance of existing lubricants and inform the development of new ones, a deposit control test protocol has been developed using the ExxonMobil Enterprise two-stroke marine diesel research engine. Repeated tests at the target speed/load operating condition but different thermal conditions show that the temperature of the combustion gases is a key driver in the formation of deposits on piston surfaces, impacting both the quantity of deposits and whether they are hard or gummy. These impacts are examined for diesel combustion as well as ammonia dual-fuel combustion. Among alternative marine fuels, ammonia has perhaps the most unanswered questions regarding interactions with cylinder lubricants. The influence of ammonia dual-fuel combustion on the thermal conditions experienced by the lubricant are discussed. Scrape down oil samples were collected after operation with ammonia for analysis and comparison with fresh oil. Chemical analysis using a GC/MS instrument did not show significant permanent chemical changes in the lubricant due to ammonia exposure.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Guidelines for Phase Change Material Selection Based on a Holistic System Model

Concentrating solar power (CSP) has potential to increase the amount of renewable energy on electric grids and reduce global carbon emissions, in particular because of its capability to incorporate inexpensive thermal energy storage. To realize this potential, development of latent heat storage with phase change materials (PCMs) is attractive because of its high energy density and low material cost. Research in this area has identified many promising materials, and has developed effective storage system designs that could be used to deploy PCMs. However, the field has lacked a rigorous methodology to select the optimal material for a particular CSP system. To address this need, here we present a holistic model that evaluates all important influences of PCM properties on the performance and cost of an entire CSP plant. We apply this model to over 100 of the most widely considered candidate materials, including both salts and metals. We quantify the relative value of each PCM property, and identify leading materials for application in CSP systems. This method and our results may aid future efforts to develop latent heat storage by providing a more informed view of how material selection impacts an entire CSP system.

14 SOLAR ENERGY↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗