Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

MO-C-BRD-01: SBRT I: Overview of Simulation, Planning, and Delivery

SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. Treatment planning of SBRT is characterized by precise target volume delineation, highly conformal dose distribution, sharp dose gradient outside the target volume, and meticulous tumor motion management. Stringent dose volume constraints of SBRT require the treatment planning to be highly personalized. Not only the complete patient's medical information (anatomy, tumor size/shape/location/motion, breathing pattern, health status) should be taken into consideration during planning, but also a wide range of factors including imaging techniques (imaging modality, breathing control, immobilization, patient position, etc.), treatment planning techniques (3D-conformal, dynamic conformal arcs, IMRT, VMAT, etc.), image guidance techniques (CBCT, orthogonal X-Ray, fiducial marker tracking, fluoroscopy, etc.), and delivery techniques (FFF, gating, tracking, etc.). In addition, potential pitfalls may exist in SBRT techniques and processes, such as target volume error in 4DCT and image registration error in image guidance. How to manage these affecting factors to achieve optimal, personalized SBRT treatment plans remains a great challenge. In this proposal, we will review technologies, share experiences, and discuss strategies concerning SBRT simulation, planning, and delivery. Learning Objectives: Understand requirements and challenges of SBRT treatment planning Discuss information-driven strategies of developing optimal SBRT plans Discuss practical considerations and potential pitfalls of SBRT treatment planning.

60 APPLIED LIFE SCIENCES↗

A workflow for segmenting soil and plant X-ray computed tomography images with deep learning in Google’s Colaboratory

X-ray micro-computed tomography (X-ray μCT) has enabled the characterization of the properties and processes that take place in plants and soils at the micron scale. Despite the widespread use of this advanced technique, major limitations in both hardware and software limit the speed and accuracy of image processing and data analysis. Recent advances in machine learning, specifically the application of convolutional neural networks to image analysis, have enabled rapid and accurate segmentation of image data. Yet, challenges remain in applying convolutional neural networks to the analysis of environmentally and agriculturally relevant images. Specifically, there is a disconnect between the computer scientists and engineers, who build these AI/ML tools, and the potential end users in agricultural research, who may be unsure of how to apply these tools in their work. Additionally, the computing resources required for training and applying deep learning models are unique, more common to computer gaming systems or graphics design work, than to traditional computational systems. To navigate these challenges, we developed a modular workflow for applying convolutional neural networks to X-ray μCT images, using low-cost resources in Google’s Colaboratory web application. Here we present the results of the workflow, illustrating how parameters can be optimized to achieve best results using example scans from walnut leaves, almond flower buds, and a soil aggregate. We expect that this framework will accelerate the adoption and use of emerging deep learning techniques within the plant and soil sciences.

59 BASIC BIOLOGICAL SCIENCES↗

Toward memory-efficient melt pool monitoring: a classification framework using event-based imaging and sparse sensing technique

Vision sensors like CMOS and CCD cameras are often used for in-process monitoring of melt pools in laser-based additive and welding processes, but they require transferring large amounts of data and computational processing resources. Event-based neuromorphic imagery, on the other hand, detects only the change in pixel intensity, thus potentially reducing the data amount and latency. With an event imager, this study develops a framework for melt pool condition classification, including image construction, time scale selection, optimal pixel selection, and sparse classification, to achieve a highly memory-efficient scheme. These are based on sparse sensing techniques with singular value decomposition (SVD) and QR pivoting, the two fundamental matrix transformations for linear dimensionality reduction. The framework is then validated by classifying a controlled experiment by exciting various mode shapes of liquid gallium pools of varying depths (3, 6, and 8 mm). At 200 pixels, the classifier can reach overall accuracy of 75%, while at 2000 pixels (0.013% of the total possible pixels), the accuracy is nearly 90% (89.86%). At the same number of pixels, random selection can only achieve 46% and 67%, respectively. The memory savings of the sparsely sampled event data compared to a conventional imager is about 500 times. In addition to performance, implementation and limitations of the framework are also discussed.

42 ENGINEERING↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-P-48: The Quantitative Evaluation and Comparison of Image Distortion and Loss of X-Ray Images Between Anti-Scattered Grid and Moire Compensation Processing in Digital Radiography

Purpose: To quantitatively analyze the influence image processing for Moire elimination has in digital radiography by comparing the image acquired from optimized anti-scattered grid only and the image acquired from software processing paired with misaligned low-frequency grid. Methods: Special phantom, which does not create scattered radiation, was used to acquire non-grid reference images and they were acquired without any grids. A set of images was acquired with optimized grid, aligned to pixel of a detector and other set of images was acquired with misaligned low-frequency grid paired with Moire elimination processing algorithm. X-ray technique used was based on consideration to Bucky factor derived from non-grid reference images. For evaluation, we analyze by comparing pixel intensity of acquired images with grids to that of reference images. Results: When compared to image acquired with optimized grid, images acquired with Moire elimination processing algorithm showed 10 to 50% lower mean contrast value of ROI. Severe distortion of images was found with when the object’s thickness was measured at 7 or less pixels. In this case, contrast value measured from images acquired with Moire elimination processing algorithm was under 30% of that taken from reference image. Conclusion: This study shows the potential risk of Moire compensation images in diagnosis. Images acquired with misaligned low-frequency grid results in Moire noise and Moire compensation processing algorithm used to remove this Moire noise actually caused an image distortion. As a result, fractures and/or calcifications which are presented in few pixels only may not be diagnosed properly. In future work, we plan to evaluate the images acquired without grid but based on 100% image processing and the potential risks it possesses.

60 APPLIED LIFE SCIENCES↗

Diffuse back-illumination temperature imaging (DBI-TI), a novel soot thermometry technique

To meet stringent emissions regulations on soot emissions, it is critical to further advance the fundamental understanding of in-cylinder soot formation and oxidation processes. Among several optical techniques for soot quantification, diffuse back-illumination extinction imaging (DBI-EI) has recently gained traction mainly due to its ability to compensate for beam steering, which if not addressed, can cause unacceptably high measurement uncertainty. Until now, DBI-EI has only been used to measure the amount of soot along the line of sight, and here, we extend the capabilities of a DBI-EI setup to also measure in-cylinder soot temperature. This proof of concept of diffuse back-illumination temperature imaging (DBI-TI) as a soot thermometry technique is presented by implementing DBI-TI in a single cylinder, heavy-duty, optical diesel engine to provide 2-D line-of-sight integrated soot temperature maps. The potential of DBI-TI to be an accurate thermometry technique for use in optical engines is analyzed. The achievable accuracy is due in part to simultaneous measurement of the soot extinction, which circumvents the uncertainty in dispersion coefficients that depend on the optical properties of soot and the wavelength of light utilized. Analysis shows that DBI-TI provides temperature estimates that are closer to the mass-averaged soot temperature when compared to other thermometry techniques that are more sensitive to soot temperature closer to the detector. Furthermore, uncertainty analysis and Monte Carlo (MC) simulations provide estimates of the temperature measurement errors associated with this technique. The MC simulations reveal that for the light intensities and optical densities encountered in these experiments, the accuracy of the DBI-TI technique is comparable or even better than other established optical thermometry techniques. Thus, DBI-TI promises to be an easily implementable extension to the existing DBI-EI technique, thereby extending its ability to provide comprehensive line-of-sight integrated information on soot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-C-BRD-01: Image Guided SBRT I: Multi-Modality 4D Imaging

Motion management is one of the critical technical challenges for radiation therapy. 4D imaging has been rapidly adopted as essential tool to assess organ motion associated with respiratory breathing. A variety of 4D imaging techniques have been developed and are currently under development based on different imaging modalities such as CT, MRI, PET, and CBCT. Each modality provides specific and complementary information about organ and tumor respiratory motion. Effective use of each different technique or combined use of different techniques can introduce a comprehensive management of tumor motion. Specifically, these techniques have afforded tremendous opportunities to better define and delineate tumor volumes, more accurately perform patient positioning, and effectively apply highly conformal therapy techniques such as IMRT and SBRT. Successful implementation requires good understanding of not only each technique, including unique features, limitations, artifacts, imaging acquisition and process, but also how to systematically apply the information obtained from different imaging modalities using proper tools such as deformable image registration. Furthermore, it is important to understand the differences in the effects of breathing variation between different imaging modalities. A comprehensive motion management strategy using multi-modality 4D imaging has shown promise in improving patient care, but at the same time faces significant challenges. This session will focuses on the current status and advances in imaging respiration-induced organ motion with different imaging modalities: 4D-CT, 4D-MRI, 4D-PET, and 4D-CBCT/DTS. Learning Objectives: Understand the need and role of multimodality 4D imaging in radiation therapy. Understand the underlying physics behind each 4D imaging technique. Recognize the advantages and limitations of each 4D imaging technique.

60 APPLIED LIFE SCIENCES↗

Calculation of grain boundary normals directly from 3D microstructure images

The determination of grain boundary normals is an integral part of the characterization of grain boundaries in polycrystalline materials. These normal vectors are difficult to quantify due to the discretized nature of available microstructure characterization techniques. The most common method to determine grain boundary normals is by generating a surface mesh from an image of the microstructure, but this process can be slow, and is subject to smoothing issues. A new technique is proposed, utilizing first order Cartesian moments of binary indicator functions, to determine grain boundary normals directly from a voxelized microstructure image. In order to validate the accuracy of this technique, the surface normals obtained by the proposed method are compared to those generated by a surface meshing algorithm. Specifically, the local divergence between the surface normals obtained by different variants of the proposed technique and those generated from a surface mesh of a synthetic microstructure constructed using a marching cubes algorithm followed by Laplacian smoothing is quantified. Next, surface normals obtained with the proposed method from a measured 3D microstructure image of a Ni polycrystal are used to generate grain boundary character distributions (GBCD) for Σ3 and Σ9 boundaries, and compared to the GBCD generated using a surface mesh obtained from the same image. Finally, the results show that the proposed technique is an efficient and accurate method to determine voxelized fields of grain boundary normals.

36 MATERIALS SCIENCE↗

A Framework of Hyperspectral Image Compression using Neural Networks

Hyperspectral image analysis has gained considerable attention due to its wide range of applications. Hyperspectral images provide a vast amount of information about underlying objects in an image by using a large range of the electromagnetic spectrum for each pixel. However, since the same image is taken multiple times using distinct electromagnetic bands, the size of such images tend to be significant, which leads to greater processing requirements. The aim of this paper is to present a proposed framework for image compression and to study the possible effects of spatial compression on quality of unmixing results. Image compression allows us to reduce the dimensionality of an image while still preserving most of the original information, which could lead to faster image processing. This paper presents preliminary results of different training techniques used in Artificial Neural Network (ANN) based compression algorithm.

97 MATHEMATICS AND COMPUTING↗

Autonomous real-time detection of plumes and jets from moons and comets

Dynamic activity on the surface of distant moons, asteroids, and comets can manifest as jets or plumes. These phenomena provide information about the interior of the bodies and the forces (gravitation, radiation, thermal) they experience. Fast detection and follow-up study is imperative since the phenomena may be time-varying and because the observing window may be limited (e.g., during a flyby). We have developed an advanced method for real-time detection of plumes and jets using onboard analysis of the data as it is collected. In contrast to prior work, our technique is not restricted to plume detection from spherical bodies, making it relevant for irregularly shaped bodies such as comets. Further, our study analyzes raw data, the form in which it is available on board the spacecraft, rather than fully processed image products. In summary, we contribute a vital assessment of a technique that can be used on board tomorrow's deep space missions to detect, and respond quickly to, new occurrences of plumes and jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Scientific instrument engineering at Japanese congresses devoted to high-speed imaging

The information about the congresses held in Japan and devoted to fast imaging processes and photonics is presented. Reports devoted to the technique and the results of applications of superhigh-speed recording instrumentation in different fields of science and technology are considered. (registration of fast processes)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

Spatial and temporal dynamics of receptor for advanced glycation endproducts, integrins, and actin cytoskeleton as probed with fluorescence-based imaging techniques

Systematic spatial and temporal fluctuations are a fundamental part of any biological process. For example, lateral diffusion of membrane proteins is one of the key mechanisms in their cellular function. Lateral diffusion governs how membrane proteins interact with intracellular, transmembrane, and extracellular components to achieve their function. Herein, fluorescence-based techniques are used to elucidate the dynamics of receptor for advanced glycation end-products (RAGE) and integrin membrane proteins. RAGE is a transmembrane protein that is being used as a biomarker for various diseases. RAGE dependent signaling in numerous pathological conditions is well studied. However, RAGE lateral diffusion in the cell membrane is poorly understood. For this purpose, effect of cholesterol, cytoskeleton dynamics, and presence of ligand on RAGE lateral diffusion is investigated.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-18C-15: Model-Based Multiscale Noise Reduction On Low Dose Cone Beam Projection

Purpose: To improve image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low dose cone beam CT (CBCT) imaging systems, Poisson process governs the randomness of photon fluence at x-ray source and the detector because of the independent binomial process of photon absorption in medium. On a CBCT projection, the variance of fluence consists of the variance of noiseless imaging structure and that of Poisson noise, which is proportional to the mean (noiseless) of the fluence at the detector. This requires multiscale filters to smoothen noise while keeping the structure information of the imaged object. We used a mathematical model of Poisson process to design multiscale filters and established the balance of noise correction and structure blurring. The algorithm was checked with low dose kilo-voltage CBCT projections acquired from a Varian OBI system. Results: From the investigation of low dose CBCT of a Catphan phantom and patients, it showed that our model-based multiscale technique could efficiently reduce noise and meanwhile keep the fine structure of the imaged object. After the image processing, the number of visible line pairs in Catphan phantom scanned with 4 ms pulse time was similar to that scanned with 32 ms, and soft tissue structure from simulated 4 ms patient head-and-neck images was also comparable with scanned 20 ms ones. Compared with fixed-scale technique, the image quality from multiscale one was improved. Conclusion: Use of projection-specific multiscale filters can reach better balance on noise reduction and structure information loss. The image quality of low dose CBCT can be improved by using multiscale filters.

60 APPLIED LIFE SCIENCES↗

SAR Imagery Segmentation by Statistical Region Growing and Hierarchical Merging

This paper presents an approach to accomplish synthetic aperture radar (SAR) image segmentation, which are corrupted by speckle noise. Some ordinary segmentation techniques may require speckle filtering previously. Our approach performs radar image segmentation using the original noisy pixels as input data, eliminating preprocessing steps, an advantage over most of the current methods. The algorithm comprises a statistical region growing procedure combined with hierarchical region merging to extract regions of interest from SAR images. The region growing step over-segments the input image to enable region aggregation by employing a combination of the Kolmogorov-Smirnov (KS) test with a hierarchical stepwise optimization (HSWO) algorithm for the process coordination. We have tested and assessed the proposed technique on artificially speckled image and real SAR data containing different types of targets.

42 ENGINEERING↗

Comparing nonrigid registration techniques for motion corrected MR prostate diffusion imaging

Purpose: T{sub 2}-weighted magnetic resonance imaging (MRI) is commonly used for anatomical visualization in the pelvis area, such as the prostate, with high soft-tissue contrast. MRI can also provide functional information such as diffusion-weighted imaging (DWI) which depicts the molecular diffusion processes in biological tissues. The combination of anatomical and functional imaging techniques is widely used in oncology, e.g., for prostate cancer diagnosis and staging. However, acquisition-specific distortions as well as physiological motion lead to misalignments between T{sub 2} and DWI and consequently to a reduced diagnostic value. Image registration algorithms are commonly employed to correct for such misalignment. Methods: The authors compare the performance of five state-of-the-art nonrigid image registration techniques for accurate image fusion of DWI with T{sub 2}. Results: Image data of 20 prostate patients with cancerous lesions or cysts were acquired. All registration algorithms were validated using intensity-based as well as landmark-based techniques. Conclusions: The authors’ results show that the “fast elastic image registration” provides most accurate results with a target registration error of 1.07 ± 0.41 mm at minimum execution times of 11 ± 1 s.

60 APPLIED LIFE SCIENCES↗

Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography

Information on the anatomy of the cardiac venous system (CVS) is increasingly important for cardiac resynchronization therapy or percutaneous transvenous mitral valve annuloplasty. Three-dimensional (3D) imaging can further improve the understanding of the relationship of cardiac structures. This study was performed to validate the accuracy of rotational coronary sinus angiography (CSA) displaying the 3D anatomy of the CVS compared to ECG-gated, contrast-enhanced, cardiac dual-source computed tomography (DSCT). Five domestic pigs (60 kg) underwent DSCT using a standardized examination protocol. Using a standard C-arm for fluoroscopy, a rotational CSA was obtained and 3D-image reconstructions performed. Side branches were identified using both methods and enumerated. Vessel visibility was estimated for each side branch and great cardiac vein/anterior interventricular vein. Also, vessel diameters were measured at distinct landmarks, i.e., side branching. The amount of contrast medium was determined and the effective radiation exposure of both methods was calculated. There was no significant difference regarding the vessel diameter of the great cardiac vein/anterior interventricular vein or its side branches. Also, estimation of vessel visibility was not different between the two imaging modalities. Estimated radiation exposure and amount of contrast medium were lower for rotational CSA. In conclusion, a 3D reconstruction of rotational CSA images is possible. All parts of the CVS are well depicted, allowing a 3D overview of the CVS anatomy. On-site 3D visualization might improve decision making during cardiac interventions. In contrast to DSCT, rotational CSA does not demonstrate the anatomy of the mitral annulus or the course of the left circumflex artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗