Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Robust cycloid crossover driven by anisotropy in the skyrmion host GaV 4 S 8

We report on the anomalous magnetization dynamics of the cycloidally modulated spin textures under the influence of uniaxial anisotropy in multiferroic GaV 4 S 8 . The temperature and field dependence of the linear ac susceptibility [$χ'_{1ω}$ (T, H)], AC magnetic loss [$χ''_{1ω}$ (T, H)], and nonlinear AC magnetic response [$M_{3ω}$ (T, H)] are examined across the magnetic phase diagram in the frequency range f = 10 - 10 000 Hz. According to recent theory, skyrmion vortices under axial crystal symmetry are confined along specific orientations, resulting in enhanced robustness against oblique magnetic fields and altered spin dynamics. We characterize the magnetic response of each spin texture and find that the dynamic rigidity of the Néel skyrmion lattice appears enhanced compared to Bloch-type skyrmions in cubic systems, even in the multidomain state. Anomalous M 3 ω and strong dissipation emerge over the same phase regime where strong variations in the cycloid pitch were observed on lowering temperature in recent small-angle neutron-scattering experiments [White et al., Phys. Rev. B 97, 020401(R) (2018)]. Here, we show that strong anisotropy also drives an extended crossover of the zero-field cycloid texture in GaV 4 S 8 . The frequency dependence of these dynamic signatures is consistent with that of a robust anharmonic spin texture exhibiting a correlated domain arrangement. The results underpin the essential role of magnetic anisotropy in enhancing the rigidity of topological spin textures for diverse applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Effective sensor location for detection of change in structural dynamic response

This paper investigates the sensitivity of structural system response to the sensor location by investigating consequences of small changes in the location to the structural system response. The paper discusses how maximum observability (based on mode shape and the participation of that mode in the input provided) drives optimal location. The structural responses were investigated in terms of the g-rms response for various low-frequency inputs (pure sinusoids and real-life inputs such as an earthquake and trains). Results were then analyzed in the context of Modal Contributions Factors (MCF) and changes to the Force-to-response Transfer Functions (TRFs). A modal-matching process is first presented using a Matlab TM -based Finite Element Method (FEM) model of a cantilever beam and instrumentation to determine the location of a small mass based on three different criteria. Subsequently, the structural response is investigated using experiments and the FEM model. The accelerometer of small mass (at 1/3 height) was moved up or down to obtain changes in the structural response (TRF) to various realistic low-frequency inputs. Modal Contribution Factor (MCF) and derivative (slope) of the associated mode-shapes were correlated to the observed changes in TRFs. Results show how optimal sensor locations for detecting change in structural response can be based on the MCFs and the associated mode-shapes.

Woodall, J.↗

Open Source Suite for Advanced Synchrophasor Analysis

The report presents the results of the development of the open-source suite of applications for synchrophasor analysis. The suite includes several software tools for oscillation analysis, power plant model validation, and frequency response analysis using synchrophasor measurements. All tools are based on the common framework and data sources. The developed tools have been used by different electrical utilities for synchrophasor analysis. The report includes several use cases based on the actual system PMU data.

20 FOSSIL-FUELED POWER PLANTS↗

Reducing AI RAG Hallucination by Optimizing Routing Techniques

Large Language Models (LLMs), such as ChatGPT, tend to “hallucinate”, meaning they confidently generate false information. Retrieval Augmented Generation (RAG) attempts to diminish hallucination by providing context to the LLM from data stores (indexes) containing relevant information. The LLM uses this context to formulate its response. RAG systems can still suffer from hallucination because of bad embeddings or ineffective routing. For example, a router will often return context from an irrelevant index, resulting in a hallucinated answer. In this study, we aim to minimize the frequency of routing hallucinations by optimizing Index Summary Routing.

97 MATHEMATICS AND COMPUTING↗

A Reversed Impedance-Based Stability Criterion for IBR Grids

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

A mechanistic understanding of oxygen isotopic changes in the Western United States at the Last Glacial Maximum

At the Last Glacial Maximum (LGM), records suggest drier conditions in the northwest United States and wetter conditions in the southwest United States relative to present-day as well as widespread changes in the isotopic composition of water. However, the mechanisms responsible for these changes remain ambiguous. Here, we explore differences in western United States hydroclimate between the LGM and preindustrial with a water isotope tracer enabled Earth System Model. We then use proxy forward models to compare simulated and recorded δ 18 O in speleothems. We find that the pattern of hydroclimate response in the western United States at the LGM relates to a combination of 1) increased frequency and southward shifted wintertime extratropical cyclones in the North Pacific, 2) greater rainout of moisture as it moves over the continent, and 3) reduced evaporation in the cooler LGM climate. The simulated lower δ 18 O of precipitation at the LGM relates predominantly to an increase in cool season moisture removal efficiency, with a secondary contribution from relatively more cool season precipitation. Both surface temperatures and North American ice sheets contribute to these hydroclimate changes at the LGM. Comparisons between δ 18 O from proxy forward models and speleothem records in the western United States show general agreement at the LGM, with increasing depletion moving towards the continental interior. Finally, this study highlights the similarities and differences between hydrologic and δ 18 O changes at the LGM and emphasizes the utility of model-proxy comparison for interpretation.

54 ENVIRONMENTAL SCIENCES↗

Inference of response functions with the help of machine-learning algorithms

Response functions are a key quantity to describe the near-equilibrium dynamics of strongly interacting many-body systems. Recent techniques that attempt to overcome the challenges of calculating these ab initio have employed expansions in terms of orthogonal polynomials. We employ a neural network prediction algorithm to reconstruct a response function 𝑆⁡(𝜔) defined over a range in frequencies 𝜔. Here, we represent the calculated response function as a truncated Chebyshev series whose coefficients can be optimized to reduce the representation error. We compare the quality of response functions obtained using coefficients calculated using a neural network (NN) algorithm with those computed using the Gaussian integral transform (GIT) method. In the regime where only a small number of terms in the Chebyshev series are retained, we find that the NN scheme outperforms the GIT method.

Kurkcuoglu, Doga Murat [Fermi National Accelerator↗

Biomass Burning Emissions of Black Carbon over the Maritime Continent and ENSO Variability

Fire emissions from the Maritime Continent (MC) over the western tropical Pacific are strongly influenced by El Niño–Southern Oscillation (ENSO), posing various climate effects to the Earth system. Here, in this study, we show that the historical biomass burning emissions of black carbon (BC bb ) aerosol in the dry season from the MC are strengthened in El Niño years due to the dry conditions. The eastern Pacific type of El Niño exerts a stronger modulation in BC bb emissions over the MC region than the central Pacific type of El Niño. Based on simulations using the fully coupled Community Earth System Model (CESM), the impacts of increased BC bb emissions on ENSO variability and frequency are also investigated in this study. With BC bb emissions from the MC scaled up by a factor of 10, which enables the identification of climate response from the internal variability, the increased BC bb heats the local atmosphere and changes land–sea thermal contrast, which suppresses the westward transport of the eastern Pacific surface water. It leads to an increase in sea surface temperature in the eastern tropical Pacific, which further enhances ENSO variability and increases the frequency of extreme El Niño and La Niña events. This study highlights the potential role of BC bb emissions on extreme ENSO frequency, and this role may be increasingly important in the warming future with higher wildfire risks.

54 ENVIRONMENTAL SCIENCES↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Central Cut Width on the Dynamical Characteristics of Box Assembly Structure

An investigation into the Box Assembly with Removable Component (BARC) structure is conducted by utilizing computational simulations and experimental structural testing in order to determine the complex dynamical responses instigated by the central cut of the system. Because the dynamics of the BARC system is complex, this study focuses primarily on analyzing the behavior of the box assembly (BA) system. The investigation explores the dynamics of the BA system by varying the central cut widths, ranging from a cut as wide as 0.5” cut to a 0.25” cut system, as well as a 0.1” cut and a system with no cut at all. Experimental testing is performed on each system including a free vibration test using an impact hammer to excite and identify the dominant frequencies of each structure. This testing is followed by pseudo-random vibration tests and swept sinusoidal excitation tests to determine the nonlinear aspects of these systems, such as the possible existence of nonlinear softening, hardening, and/or damping. The results show that nonlinear softening and nonlinear damping are present in each system. The no-cut system demonstrated the highest peak frequencies throughout all the tests, being the most rigid structure. The 0.25” cut system was shown to have the highest peak frequencies among all the cut systems in both the finite elemenet analysis (FEA) and impact testing. This trend did not continue, though, in the random and harmonic testing, possibly due to the added stiffness of the test setup with the slip table and stinger. The results show the importance of accurately measuring the central cut width and how possible geometric uncertainties change the overall dynamical behaviors of complex systems, such as natural characteristics, nonlinear responses, coupling of modes, and oscillating amplitudes.

Padilla, Christopher (ORCID:000900033446732X)↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗

Hypersonic Fluid–Structure Interaction on a Cone–Slice–Ramp Geometry

In this study, fluid–structure interactions were measured between a representative control surface and the hypersonic flow deflected by it. The control surface is simplified as a spanwise finite ramp placed on a longitudinal slice of a cone. The front surface of the ramp contains a thin panel designed to respond to the unsteady fluid loading arising from the shock-wave/boundary-layer interactions. Experiments were conducted at Mach 5 and Mach 8 with ramps of different angles. High-speed schlieren captured the unsteady flow dynamics and accelerometers behind the thin panel measured its structural response. Panel vibrations were dominated by natural modes that were excited by the broadband aerodynamic fluctuations arising in the flowfield. However, increased structural response was observed in two distinct flow regimes: 1) attached or small separation interactions, where the transitional regime induced the strongest panel fluctuations. This was in agreement with the observation of increased convective undulations or bulges in the separation shock generated by the passage of turbulent spots, and 2) large separated interactions, where shear layer flapping in the laminar regime produced strong panel response at the flapping frequency. In addition, panel heating during the experiment caused a downward shift in its natural mode frequencies.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing Catalysis by Combining Molecular Scaling Relationships: Iron Porphyrin-Catalyzed Electrochemical Oxygen Reduction as a Case Study

Here, the present work demonstrates the generality of molecular scaling relationships toward achieving faster catalysis at lower overpotentials. In iron porphyrin-catalyzed oxygen reduction, independent tuning of the catalyst E 1/2 and buffer pK a resulted in improvement of both the maximum turnover frequency (TOF max ) and the effective overpotential (η eff ). Interestingly, the most optimal system is achieved with the most reducing catalyst and a weak buffered acid—a perhaps counterintuitive conclusion. More generally, this study illustrates a path to optimization of catalytic systems through their differing responses to changes in the intrinsic features of the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resonant nonlinear refraction of 4 – 5 - μ m light in CO and C O 2 gas

The resonant nonlinear refraction of 4–5-μm light in CO and CO 2 gas at a peak intensity of 15MW/cm 2 was demonstrated using time- and frequency-resolved measurements of self-focusing and self-defocusing. The nonlinearity of these molecular gases exhibits intensity-dependent sign reversals and a <4-ns response time. A change from self-focusing to self-defocusing or vice versa was observed to occur for Rabi frequencies that are comparable to the collisional linewidth. A density matrix model for the nonlinear susceptibility of a strongly driven two-level system provides a qualitative explanation for these results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗