Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Exploring Multidimensional Spatial-Temporal Hydropower Operational Flexibilities by Modeling and Optimizing Water-Constrained Cascading Hydroelectric Systems

Because of unique characteristics such as clean and cost-competitive electricity as well as fast-ramping and storage abilities, the power industry continues to evolve its operation strategies for cascading hydroelectric (CHE) systems for providing enhanced values to the grid, especially under the deeper renewable resource integration. However, existing operation practices of CHEs predate the integration of renewables, which could prohibit the effective utilization of their inherent flexibilities in delivering maximum financial benefits and providing valuable grid services to the power system and electricity market operations. Indeed, modeling and optimizing these resource-limited while flexible CHE assets with uncertainties and imperfect information across multiple spatial-temporal dimensions present significant challenges. To facilitate CHE facility operators in effectively coordinating water usage and hydropower plant operations across multiple timescales, this project aims to fill the existing gaps by developing a suite of accurate water inflow (WI) forecast models as well as enhanced CHE modeling and optimization approaches with proper consideration of their unique characteristics, which would help explore their multidimensional spatial-temporal operational flexibility potentials. The developed approaches could better align reservoir operation strategies with variability and uncertainty of future water availability. They can also promote more effective utilization of multidimensional spatial-temporal hydropower operational flexibility potentials by designing long-term evacuation plans of reservoirs and short-term operation of CHEs, along with their coordination with other types of renewables. The project leverages various resources to facilitate the research and development activities, including actual characteristics data of CHE systems and a library of current and future cases of Portland General Electric (PGE). These realistic data enable the project team to study how to maximize the value of CHEs under current and future portfolios and evaluate opportunities to improve operation practices.

13 HYDRO ENERGY↗

Welcome to the Special Issue on Grid-Edge Computing With Behind-the-Meter Resources [Guest Editorial]

The integration of distributed energy resources (DERs), such as solar photovoltaic systems, as well as other synergistic assets, including electric vehicles, energy storage, and smart appliances, in electric power systems has been dramatically increasing in the past few years. These assets have the capability to provide much-needed flexibility to electric power systems for improved grid reliability, resilience, and economic efficiency; however, most of these resources are located behind the meter (BTM) on customer premises, and their flexibility is not fully used in current grid operations. Grid-edge computing plays an important role in unlocking the great benefits and potential that BTM resources could provide to electric power systems by enhancing visibility and controllability at the grid edge.

behind-the-meter resources↗

Field Testing of a Hierarchical Model-Free Transactive Control Strategy in a Residential House

Demand response plays an important role in addressing the uncertain, intermittent, and variable nature of renewable energy sources. However, to be effective, it requires a significant amount of demand load flexibility, in which buildings are important flexible assets for electricity systems. In this regard, many transactive control tools have been developed to harness this demand flexibility. Yet, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a field implementation and testing of a hierarchical model-free transactive control strategy using residential building thermostatically controlled loads. The transactive control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. Experimental field-testing results are provided to demonstrate the effectiveness of the proposed transactive control strategy.

Olama, Mohammed M.↗

Ultra: Underwater Laser Telecommunications & Remote Access (Final Report)

High speed wireless communication has proven elusive in subsea environments due to the inherent bandwidth limitations of acoustics and range limitations of other transmission modalities. A truly connected subsea system necessitates a high-speed, resilient architecture that can enable the integration of new sensor technologies and edge analytics and allow closed-loop monitoring and control of subsea operations for integrity monitoring and optimization. Like terrestrial Internet of Things applications, the realization of this “digital subsea” vision requires the application of high speed, point-to-point wireless technologies to complement rather than replace “hard-wired” communications such as optical fiber or acoustic systems. This work addresses the development of ULTRA (Underwater LASER Telemetry and Remote Access), an ultra-long range underwater laser communications system for use in critical points of the subsea communications architecture to increase reliability, operational flexibility, and reduce communication system maintenance associated with physical subsea connections.

02 PETROLEUM↗

Estimating Flexibility Envelopes for Residential Customers From Utility Smart Meter Data: Preprint

Demand response from residential customers has significant potential to support power system operations, but accurate flexibility estimation is challenging due to the limited resolution of advanced metering infrastructure (AMI) data. Most utility AMI measurements are recorded at hourly intervals, with only a small portion at higher resolutions, and even fewer households have appliance-level energy usage data. To address this issue, this paper proposes a two-stage long short-term memory (LSTM) framework for estimating household flexibility envelopes from low-resolution AMI data. In the first stage, the heating, ventilating, and air-conditioning (HVAC) load and non-HVAC loads are estimated by using a model trained on a small set of households with appliance-level profiles. These estimated data are then used to compute the upper- and lower-flexibility bounds, which are subsequently down-sampled to lower-resolution data. In the second stage, these flexibility bounds serve as training inputs for another LSTM model, enabling direct prediction of flexibility envelopes for households with only hourly AMI data. This method is validated using Pecan Street data from two different areas, and the results demonstrate its applicability and effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities for installed combined heat and power (CHP) to increase grid flexibility in the U.S.

Increasing use of renewable energy requires sufficient grid flexibility to address uncertainty and variability in electricity generation. Previous studies suggest that combined heat and power (CHP) systems may support grid flexibility but they do not consider operating hours. In this paper, we used CHP operating data and determined annual and monthly availability of the installed CHP capacity from various sectors (e.g., utility, independent power producer, commercial, and industrial) in all seven U.S. independent system operators (ISOs) and regional transmission organizations (RTOs). Also, we estimated hourly CHP availability installed in five facility types (i.e., hospitals, universities, hotels, offices, and manufacturing) in the state of New York. The results show that regardless of ISO/RTO, sector, or season, more than 40% of the installed CHP capacity (0.7–8.7 GW) was not fully utilized in 2019; the results are similar for 2018. This available CHP capacity accounted for up to 9% of the ISO/RTO's peak electric demand, which may yield cost savings up to $16 billion by avoiding installation costs of new natural gas combustion or combined-cycle turbines. To exploit the available CHP capacity to enhance grid flexibility, we recommend different policy implications including flexible contract lengths between CHP owners and grid operators, improved market designs, and simplified interconnection standards.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Framework for Effective Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond

Net load imbalances due to imperfect day-ahead forecasts can cause variability in real-time electricity prices and higher system operations costs. We propose a novel market product called Flexibility Options that allow participants to hedge uncertainty by buying flexibility from flexible resources. Simulations show that flexibility options can reduce total system operating costs by up to 15% and can reduce variability in market participant revenues. To better quantify the flexibility that DER aggregators can provide, we develop DER flexibility scores that account for asset flexibility and uncertainty from occupant behavior and weather. Preliminary results show that realistic sets of DERs have significant variability in flexibility and uncertainty metrics.

delivery risk↗

PanDA: Production and Distributed Analysis System

The Production and Distributed Analysis (PanDA) system is a data-driven workload management system engineered to operate at the LHC data processing scale. The PanDA system provides a solution for scientific experiments to fully leverage their distributed heterogeneous resources, showcasing scalability, usability, flexibility, and robustness. The system has successfully proven itself through nearly two decades of steady operation in the ATLAS experiment, addressing the intricate requirements such as diverse resources distributed worldwide at about 200 sites, thousands of scientists analyzing the data remotely, the volume of processed data beyond the exabyte scale, dozens of scientific applications to support, and data processing over several billion hours of computing usage per year. PanDA’s flexibility and scalability make it suitable for the High Energy Physics community and wider science domains at the Exascale. Beyond High Energy Physics, PanDA’s relevance extends to other big data sciences, as evidenced by its adoption in the Vera C. Rubin Observatory and the sPHENIX experiment. As the significance of advanced workflows continues to grow, PanDA has transformed into a comprehensive ecosystem, effectively tackling challenges associated with emerging workflows and evolving computing technologies. The paper discusses PanDA’s prominent role in the scientific landscape, detailing its architecture, functionality, deployment strategies, project management approaches, results, and evolution into an ecosystem.

97 MATHEMATICS AND COMPUTING↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible and Effective Object Tiering for Heterogeneous Memory Systems

Computing platforms that package multiple types of memory, each with their own performance characteristics, are quickly becoming mainstream. To operate efficiently, heterogeneous memory architectures require new data management solutions that are able to match the needs of each application with an appropriate type of memory. As the primary generators of memory usage, applications create a great deal of information that can be useful for guiding memory tiering, but the community still lacks tools to collect, organize, and leverage this information effectively. To address this gap, this work introduces a novel software framework that collects and analyzes object-level information to guide memory tiering. Using this framework, this study evaluates and compares the impact of a variety of data tiering choices, including how the system prioritizes objects for faster memory as well as the frequency and timing of migration events. The results, collected on a modern Intel platform with conventional DRAM as well as non-volatile RAM, show that guiding data tiering with object-level information can enable significant performance and efficiency benefits compared to standard hardware- and software-directed data tiering strategies.

Kammerdiener, Brandon↗

Flexible and Effective Object Tiering for Heterogeneous Memory Systems

Computing platforms that package multiple types of memory, each with their own performance characteristics, are quickly becoming mainstream. To operate efficiently, heterogeneous memory architectures require new data management solutions that are able to match the needs of each application with an appropriate type of memory. As the primary generators of memory usage, applications create a great deal of information that can be useful for guiding memory management, but the community still lacks tools to collect, organize, and leverage this information effectively. To address this gap, this work introduces a novel software framework that collects and analyzes object-level information to guide memory tiering. The framework includes tools to monitor the capacity and usage of individual data objects, routines that aggregate and convert this information into tier recommendations for the host platform, and mechanisms to enforce these recommendations according to user-selected policies. Moreover, the developed tools and techniques are fully automatic, work on standard Linux systems, and do not require modification or recompilation of existing software. Using this framework, this study evaluates and compares the impact of a variety of design choices for memory tiering, including different policies for prioritizing objects for the fast memory tier as well as the frequency and timing of migration events. In conclusion, the results, collected on a modern Intel platform with conventional DDR4 SDRAM as well as Intel Optane NVRAM, show that guiding data tiering with object-level information can enable significant performance and efficiency benefits compared with standard hardware- and software-directed data-tiering strategies for a diverse set of memory-intensive workloads.

97 MATHEMATICS AND COMPUTING↗

Flexible, Multipurpose Laboratory Advances Building and Thermal Energy Systems: Expanding Evaluation and Development of Grid-Interactive Buildings

Robust hardware and controls are necessary to ensure results match their intent before they can be used broadly. However, this often requires multiple field experiments in a variety of climate zones. In the field, it is more difficult to obtain information on other important factors, such as thermal, grid, and occupant interaction. Gaps also exist in understanding the performance degradation and life cycle of thermal energy systems as they relate to buildings. There is a lack of robust, high-quality performance data for projects at scale; this data can be expensive to produce and often remain proprietary.

30 DIRECT ENERGY CONVERSION↗

Apparatus, system, and method for radiation hardened plastic and flexible elastomer scintillator

A scintillating material that is a radiation hardened plastic and flexible elastomer is disclosed. The material is useful in a wide range of high energy particle environments and can be used to create detectors. Such detectors can be used in physics experiments or in medical treatment or imaging. The scintillator can be radiation hardened so as to allow for an extended lifetime over other materials.

Akgun, Ugur↗

Storage Enabled Flexibility of Conventional Generation Assets (StorFlex)

The power systems have faced progressively more demanding operational requirements over the last two decades. Several factors contribute to these challenging operating conditions, including load growth, aging infrastructure, increasing penetrations of distributed energy resources (DERs), electrification of the economy, and policy initiatives such as decarbonization. The power system and its components must provide high operational flexibility to mitigate these challenges. For example, the proliferation of intermittent DERs such as wind and solar has increased the need for conventional generation assets like hydropower plants to respond to sudden load-generation imbalances. The higher flexibility requirements for hydropower plants cause more wear and tear, potentially shortening the useful lifespan of hydropower turbines. To reduce the need for hydropower plants to follow sudden changes in the dispatch signal, we investigate their combined operation with the energy storage systems (ESSs; “ESS-based hybridization”). Our analyses focuses on improving the lifespan of hydropower plants through ESS-based hybridization. Wear and tear on hydropower turbines (particularly Francis turbines) is modeled using a loss-of-life concept that is based on damage experienced by the turbine due to various cycles of operation. Then, we show that using ESSs to offset some of the high variation increases the remaining life of the hydropower plants. To demonstrate this, a few modeling tools were developed for this work: (1) a dynamic model for various components of the turbine and its governor; (2) a control strategy that assigns a slow-varying dispatch signal to a hydropower unit versus a fastmoving signal to ESS, such that the overall power request remains the same; and (3) models for the financial analysis to quantify the economic merits of such a framework. We used the models we developed to analyze the dispatch pattern of an actual hydropower plant with a power output of 50 MW and a head height of 152 m. This work showed that ESS-based hybridization could extend the life of the hydropower plant by 5% on average. This extension in life was then used to estimate the economic benefit in terms of cost deferrals associated with hydropower plant maintenance and replacement: on average, $3.6 million. Sensitivity analysis with respect to the size of ESS and cost of turbines was performed to show the variation in benefits over the range of turbine costs and ESS sizes. Crucially, stacking damage reduction and lifetime extension with other ESS value streams such as providing ancillary services could substantially increase the financial benefits of ESS-based hybridization. The higher costs associated with ESS of appropriate size would make more financial sense when multiple value streams are stacked and co-optimized to extract the maximum benefit. This dimension will be explored in future work.

13 HYDRO ENERGY↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

A Double-Signal Retail Pricing Scheme for Acquiring Operational Flexibility from Batteries

Batteries can provide valuable operational flexibility to facilitate the system efficiency. However, there lacks market environments to effectively harness and monetize the value of these assets. Most existing works apply a profit-oriented single-signal pricing scheme, which mixes the value of energy and flexibility together and may ultimately raise the electricity bill. Therefore, this paper proposes a profit-neutral double-signal retail pricing scheme that distinguishes elastic market players (i.e., batteries) from inelastic market players (i.e., inflexible loads) and quantifies the value of energy and flexibility separately. Experimental results indicate that under the incentive provided by the proposed retail pricing scheme: 1) The system efficiency benefit aligns with benefits to both batteries and inflexible loads; 2) Value of operational flexibility, contributing to improve the energy efficiency, can be transparently priced and fairly allocated among batteries; and 3) The dominant role in which inflexible loads play on determining the market price is avoided.

25 ENERGY STORAGE↗