Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronized sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Automation of a high-speed imaging setup for differential viscosity measurements

We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have been reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an “unknown” solution of hydroxyethyl cellulose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The correlation of X-ray emission with strong millimeter activity in extragalactic sources

A sample of 25 strong extragalactic millimeter sources have been observed at about 1 keV with the Imaging Proportional Counter on the Einstein X-Ray Observatory and at 90 GHz with the NRAO 11 m telescope. A strong correlation between the millimeter and X-ray flux densities is found. This result is consistent with a synchronous self-Compton model in which the X-ray emission arises from the Compton scattering of millimeter radio photons off the relativistic electrons which created them.

Owen, F. N.↗

Downscaling GISS ModelE Boreal Summer Climate over Africa

The study examines the perceived added value of downscaling atmosphere-ocean global climate model simulations over Africa and adjacent oceans by a nested regional climate model. NASA/Goddard Institute for Space Studies (GISS) coupled ModelE simulations for June- September 1998-2002 are used to form lateral boundary conditions for synchronous simulations by the GISS RM3 regional climate model. The ModelE computational grid spacing is 2deg latitude by 2.5deg longitude and the RM3 grid spacing is 0.44deg. ModelE precipitation climatology for June-September 1998-2002 is shown to be a good proxy for 30-year means so results based on the 5-year sample are presumed to be generally representative. Comparison with observational evidence shows several discrepancies in ModelE configuration of the boreal summer inter-tropical convergence zone (ITCZ). One glaring shortcoming is that ModelE simulations do not advance the West African rain band northward during the summer to represent monsoon precipitation onset over the Sahel. Results for 1998-2002 show that onset simulation is an important added value produced by downscaling with RM3. ModelE Eastern South Atlantic Ocean computed sea-surface temperatures (SST) are some 4 K warmer than reanalysis, contributing to large positive biases in overlying surface air temperatures (Tsfc). ModelE Tsfc are also too warm over most of Africa. RM3 downscaling somewhat mitigates the magnitude of Tsfc biases over the African continent, it eliminates the ModelE double ITCZ over the Atlantic and it produces more realistic orographic precipitation maxima. Parallel ModelE and RM3 simulations with observed SST forcing (in place of the predicted ocean) lower Tsfc errors but have mixed impacts on circulation and precipitation biases. Downscaling improvements of the meridional movement of the rain band over West Africa and the configuration of orographic precipitation maxima are realized irrespective of the SST biases.

Regional climate models↗

Selection Tests of MnZn and NiZn Ferrites for Mu2e 300 kHz and 5.1 MHz AC Dipoles

Mu2e, a charged lepton flavor violation (CLFV) experiment is planned to start at Fermilab late in this decade. The proposed experiment will search for neutrinoless muon to electron conversions with unprecedented sensitivity, better than 6 x 10{sup -17 }at 90% CL. To achieve this sensitivity the incoming proton beam must be highly suppressed during the window for detecting the muon decays. The current proposal for beam extinction is based on a collimator design with two dipoles running at {approx}300 kHz and 5.1 MHz and synchronized to the proton bunch spacing. The appropriate choice of ferrite material for the magnet yoke is a critical step in the overall design of the dipoles and their reliable operation at such high frequencies over the life of the experiment. This choice, based on a series of the thermal and magnetic measurements of the ferrite samples, is discussed in the paper. Additionally, the first results from the testing at 300 kHz of a prototype AC dipole are presented.

43 PARTICLE ACCELERATORS↗

High-Precision Time Delay Control with Continuous Phase Shifter for Pump-Probe Experiments Using Synchrotron Radiation Pulses

Brilliant pulsed x-ray synchrotron radiation (SR) is useful for pump-probe experiment such as time-resolved x-ray diffraction, x-ray absorption fine structure, and x-ray spectroscopy. For laser pump-SR x-ray probe experiments, short pulsed lasers are generally synchronized to the SR master oscillator controlling the voltage for acceleration of electron bunches in an accelerator, and the interval between the laser and the SR pulses is changed around the time scale of target phenomenon. Ideal delay control produces any time delay as keeping the time-precision and pointing-stability of optical pulses at a sample position. We constructed the time delay control module using a continuous phase shifter of radio frequency signal and a frequency divider, which can produce the delayed trigger pulses to the laser without degradation of the time precision and the pointing stability. A picoseconds time-resolved x-ray diffraction experiment was demonstrated at SPring-8 storage ring for fast lattice response by femtosecond pulsed laser irradiation, and suggested the possibility of accurate sound velocity measurement. A delay control unit operating with subpicosecond precision has also been designed for femtosecond pump-probe experiments using a free electron laser at SPring-8 campus.

43 PARTICLE ACCELERATORS↗

Advanced Engine Health Management Applications of the SSME Real-Time Vibration Monitoring System

The Real Time Vibration Monitoring System (RTVMS) is a 32-channel high speed vibration data acquisition and processing system developed at Marshall Space Flight Center (MSFC). It Delivers sample rates as high as 51,200 samples/second per channel and performs Fast Fourier Transform (FFT) processing via on-board digital signal processing (DSP) chips in a real-time format. Advanced engine health assessment is achieved by utilizing the vibration spectra to provide accurate sensor validation and enhanced engine vibration redlines. Discrete spectral signatures (such as synchronous) that are indicators of imminent failure can be assessed and utilized to mitigate catastrophic engine failures- a first in rocket engine health assessment. This paper is presented in viewgraph form.

Fiorucci, Tony R.↗

Design and Analysis of a Formation Flying System for the Cross-Scale Mission Concept

The ESA-funded "Cross-Scale Technology Reference Study has been carried out with the primary aim to identify and analyse a mission concept for the investigation of fundamental space plasma processes that involve dynamical non-linear coupling across multiple length scales. To fulfill this scientific mission goal, a constellation of spacecraft is required, flying in loose formations around the Earth and sampling three characteristic plasma scale distances simultaneously, with at least two satellites per scale: electron kinetic (~10 km), ion kinetic (~100-2000 km), magnetospheric fluid (~3000-15000 km). The key Cross-Scale mission drivers identified are the number of S/C, the space segment configuration, the reference orbit design, the transfer and deployment strategy, the inter-satellite localization and synchronization process and the mission operations. This paper presents a comprehensive overview of the mission design and analysis for the Cross-Scale concept and outlines a technically feasible mission architecture for a multi-dimensional investigation of space plasma phenomena. The main effort has been devoted to apply a thorough mission-level trade-off approach and to accomplish an exhaustive analysis, so as to allow the characterization of a wide range of mission requirements and design solutions.

Cornara, Stefania↗

Autonomous 3D and Radiation Mapping in Tunnel Environments Using Aerial Robots - 18156

In this paper we present the algorithms and systems developed to enable autonomous 3D and radiation mapping, as well as radiological source localization in tunnel environments using aerial robots. The developed technologies aim to address the need of autonomous robotic inspection of nuclear sites such as facilities in the process of being decommissioned. As a motivational example, the PUREX tunnels at the Hanford Site are considered and the robot is designed to be able to conduct multi-modal 3D/radiation characterization of the tunnel environment without any prior knowledge or map provided beforehand. In order to enable the necessary GPS-denied simultaneous localization and mapping in dark, visually-degraded tunnel environments, a multi-modal mapping unit was developed which fuses the data from stereo vision cameras synchronized with flashing LEDs, inertial sensors, and three time-of-flight 3D depth sensors. The robot's pose and surrounding map are estimated at 20 Hz through a depth-enhanced visual- inertial localization and mapping framework. Provided this ability to estimate the robot's pose and develop a dense map in real-time, a receding horizon sampling-based autonomous exploration path planning algorithm was utilized and equips the robot with the ability to explore its environment given no prior map. The aforementioned key robotic functionalities are further extended through the integration of miniaturized fully solid-state scintillation detectors, utilizing advanced scintillators and Silicon Photomultipliers. The derived sensor data is employed for radiation mapping, which when fused with the 3D maps and the spectroscopic source localization methods, allow the aerial robotic platform to localize the radiation source and identify the specific source isotope. The source location is estimated through a geometric algorithm which can localize a source given only three measurements and short dwell times. The developed systems were tested using two small aerial robot platforms of the F450 and F550 frame classes with weights of 2.6 kg and 2.9 kg respectively. All localization and planning as well as high-level control algorithms are executed onboard. The scintillation detector is integrated on the robot and its data is collected through a dedicated microcontroller. A set of field experiments were conducted inside the dark and GPS-denied environment of a 4.25 m wide, 7.5 m tall, and 137 m long railroad tunnel. A Cs-137 source was placed within the tunnel, the associated 3D/radiation maps were derived, and the source location was estimated. Through these efforts, the goal is to develop the robotic technology that would enable the autonomous systematic inspection or emergency response in nuclear waste decommissioning facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrafast supercontinuum fiber-laser based pump-probe scanning magneto-optical Kerr effect microscope for the investigation of electron spin dynamics in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution

We describe a two-color pump-probe scanning magneto-optical Kerr effect microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast “white light” supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains of two separate picosecond laser systems. The ability to independently tune the pump and probe wavelength enables the investigation of the influence of excitation energy on the optically induced electron spin dynamics in semiconductors. We demonstrate picosecond real-space imaging of the diffusive expansion of optically excited electron spin packets in a (110) GaAs quantum well sample to illustrate the capabilities of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Automatic Differentiation for Ptychography

Synchrotron radiation light source facilities are leading the way to ultrahigh resolution X-ray imaging. High resolution imaging is essential to understanding the fundamental structure and interaction of materials at the smallest length scale possible. Diffraction based methods achieve nanoscale imaging by replacing traditional objective lenses by pixelated area detectors and computational image reconstruction. Among these methods, ptychography is quickly becoming the standard for sub-30 nanometer imaging of extended samples, but at the expense of increasingly high data rates and volumes. This paper presents a new distributed algorithm for solving the ptychographic image reconstruction problem based on automatic differentiation. Input datasets are subdivided between multiple graphics processing units (GPUs); each subset of the problem is then solved either entirely independent of other subsets (asynchronously) or through sharing gradient information with other GPUs (synchronously). The algorithm was evaluated on simulated and real data acquired at the Advanced Photon Source, scaling up to 192 GPUs. The synchronous variant of our method outperformed an existing multi-GPU implementation in terms of accuracy while running at a comparable execution time.

distributed algorithms↗

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗

PACE: How One NASA Mission Aligns With the United Nations Decade of Ocean Science for Sustainable Development (Ocean Shot #2)

The PACE satellite observatory will follow a Sun synchronous, polar orbit at an altitude of 676.5 km with a local 13:00 Equatorial crossing time. Its payload consists of three instruments, a primary hyperspectral imaging radiometer being built at NASA Goddard Space Flight Center and two multispectral, multiangle polarimeters, the combination of which advances far beyond heritage capabilities. The Ocean Color Instrument (OCI) offers one-day global coverage with a ground sample distance of 1 km2 at nadir. As described in this OceanShot, this leap in technology will enable improved understanding of aquatic ecosystems and biogeochemistry, as well as provide new information on phytoplankton community composition and improved detection of algal blooms. OCI will be complemented by two small multi-angle polarimeters with spectral ranges that span the visible to near infrared spectral region. When sunlight interacts with clouds or aerosols, it comes away from that interaction changed. By measuring changes in how reflected light oscillates within a geometric plane (i.e., its viewing angle-specific polarization), we can infer useful properties of the clouds or aerosols. This information is crucial to deciphering the way sunlight is reflected and absorbed by our planet and how aerosols affect cloud formation. The polarimeters include the Spectro-polarimeter for Planetary Exploration (SPEXone) and the Hyper Angular Research Polarimeter (HARP2), both of which will significantly improve aerosol and cloud characterizations and provide opportunities for novel ocean color atmospheric correction. (Figure 3). These instruments offer complementary capabilities: SPEXone is hyperspectral, multiangular, and narrow swath to support advanced atmospheric aerosol characterizations, whereas HARP2 is multispectral, hyper-angular, and wide swath to advance cloud property retrievals. In total, the combined PACE instrument suite will revolutionize studies of global biogeochemistry, carbon cycles, and air–sea exchanges in the ocean–atmosphere system.

Ocean color↗

Fast automated energy changes at synchrotron radiation beamlines equipped with transfocator or focusing mirrors

Algorithms and procedures to fully automate retuning of synchrotron radiation beamlines over wide energy ranges are discussed. The discussion is based on the implementation at the National Institute of General Medical Sciences and the National Cancer Institute Structural Biology Facility at the Advanced Photon Source. When a user selects a new beamline energy, software synchronously controls the beamline monochromator and undulator to maintain the X-ray beam flux after the monochromator, preserves beam attenuation by determining a new set of attenuator foils, changes, as needed, mirror reflecting stripes and the undulator harmonic, preserves beam focal distance of compound refractive lens focusing by changing the In/Out combination of lenses in the transfocator, and, finally, restores beam position at the sample by on-the-fly scanning of either the Kirkpatrick–Baez mirror angles or the transfocator up/down and inboard/outboard positions. The sample is protected from radiation damage by automatically moving it out of the beam during the energy change and optimization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cosmological parameters from CMB maps without likelihood approximation

We propose an efficient Bayesian Markov chain Monte Carlo (MCMC) algorithm for estimating cosmological parameters from cosmic microwave background (CMB) data without the use of likelihood approximations. It builds on a previously developed Gibbs sampling framework that allows for exploration of the joint CMB sky signal and power spectrum posterior, P(s,C{sub ℓ}|d), and addresses a long-standing problem of efficient parameter estimation simultaneously in regimes of high and low signal-to-noise ratio. To achieve this, our new algorithm introduces a joint Markov chain move in which both the signal map and power spectrum are synchronously modified, by rescaling the map according to the proposed power spectrum before evaluating the Metropolis–Hastings accept probability. Such a move was already introduced by Jewell et al., who used it to explore low signal-to-noise posteriors. However, they also found that the same algorithm is inefficient in the high signal-to-noise regime, since a brute-force rescaling operation does not account for phase information. This problem is mitigated in the new algorithm by subtracting the Wiener filter mean field from the proposed map prior to rescaling, leaving high signal-to-noise information invariant in the joint step, and effectively only rescaling the low signal-to-noise component. To explore the full posterior, the new joint move is then interleaved with a standard conditional Gibbs move for the sky map. We apply our new algorithm to simplified simulations for which we can evaluate the exact posterior to study both its accuracy and its performance, and find good agreement with the exact posterior; marginal means agree to ≲0.006σ and standard deviations to better than ∼3%. The Markov chain correlation length is of the same order of magnitude as those obtained by other standard samplers in the field.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Solid Synchronous Reluctance Rotors With Multi-Material Additive Manufacturing

Synchronous reluctance (SynR) machines are promising rare-earth material-free alternatives to permanent magnet machines. However, structural challenges limit their operating speed and power density. This paper proposes and investigates multi-material additive manufacturing (MMAM) as a key-enabler to realize power-dense and high-speed SynR machines. It does so by proposing designs that guide magnetic flux through solid rotors realized by selective placement of magnetic and non-magnetic materials. To explore this concept, first, material samples are additively manufactured and experimentally characterized to assess the structural and magnetic properties that can be expected for the proposed rotors. Second, the design space of each rotor type is explored using these measured properties within finite element analysis. The results reveal that MMAM can enable fabrication of SynR motors with power density levels that are at the leading edge of all conventional electric machine topologies. It is shown that tip speeds in excess of 300 m/s can be achieved, resulting in 3-4x improvement in power density over conventional SynR motors. A solid SynR rotor is printed in an experimental MMAM laser powder bed fusion system. The rotor is paired with an existing stator to create a functional SynR motor with a saliency ratio of 2.59 and torque rating of 4.15 Nm. This is the first publication of a SynR rotor prototype constructed via MMAM.

36 MATERIALS SCIENCE↗

Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1- 13 C]Pyruvate

13 C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13 C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1- 13 C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13 C Radiofrequency Amplification by Stimulated Emission of Radiation ( 13 C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13 C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1- 13 C]pyruvate, which are separated by 10 ppm in 13 C NMR spectra. This is a good model system to study the simultaneous 13 C RASER signals of multiple 13 C species. This system models the metabolic production of hyperpolarized [1- 13 C]lactate from hyperpolarized [1- 13 C]pyruvate, which has a similar chemical shift difference. Our results show that 13 C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13 C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13 C signals. Furthermore, the reported results pave the way to novel sensing approaches of 13 C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13 C MRI on virtually any MRI system–an attractive vision for the future molecular imaging and diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Optical receiver system for 152-channel magnetoencephalography

An optical receiver system composing 13 serial data restore/synchronizer modules and a single module combiner converted optical 32-bit serial data into 32-bit synchronous parallel data for a computer to acquire 152-channel magnetoencephalography (MEG) signals. A serial data restore/synchronizer module identified 32-bit channel-voltage bits from 48-bit streaming serial data, and then consecutively reproduced 13 times of 32-bit serial data, acting in a synchronous clock. After selecting a single among 13 reproduced data in each module, a module combiner converted it into 32-bit parallel data, which were carried to 32-port digital input board in a computer. When the receiver system together with optical transmitters were applied to 152-channel superconducting quantum interference device sensors, this MEG system maintained a field noise level of 3 fT/√Hz @ 100 Hz at a sample rate of 1 kSample/s per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cognitive electrophysiological signature differentiates amnestic mild cognitive impairment from normal aging

Background: Noninvasive and effective biomarkers for early detection of amnestic mild cognitive impairment (aMCI) before measurable changes in behavioral performance remain scarce. Cognitive event-related potentials (ERPs) measure synchronized synaptic neural activity associated with a cognitive event. Loss of synapses is a hallmark of the neuropathology of early Alzheimer’s disease (AD). In the present study, we tested the hypothesis that ERP responses during working memory retrieval discriminate aMCI from cognitively normal controls (NC) matched in age and education. Methods: Eighteen NC, 17 subjects with aMCI, and 13 subjects with AD performed a delayed match-to-sample task specially designed not only to be easy enough for impaired participants to complete but also to generate comparable performance between subjects with NC and those with aMCI. Scalp electroencephalography, memory accuracy, and reaction times were measured. Results: Whereas memory performance separated the AD group from the others, the performance of NC and subjects with aMCI was similar. In contrast, left frontal cognitive ERP patterns differentiated subjects with aMCI from NC. Enhanced P3 responses at left frontal sites were associated with nonmatching relative to matching stimuli during working memory tasks in patients with aMCI and AD, but not in NC. The accuracy of discriminating aMCI from NC was 85% by using left frontal match/nonmatch effect combined with nonmatch reaction time. Conclusions: The left frontal cognitive ERP indicator holds promise as a sensitive, simple, affordable, and noninvasive biomarker for detection of early cognitive impairment.

60 APPLIED LIFE SCIENCES↗