Spintronics Meets Density Matrix Renormalization Group: Quantum Spin-Torque-Driven Nonclassical Magnetization Reversal and Dynamical Buildup of Long-Range Entanglement
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This paper presents a unique approach to enable real-time lifespan prediction of semiconductor power modules using a Hardware-in-the-Loop (HIL) system. By integrating the module's overall loss characteristics-specifically switching and conduction losses-with a thermoelectric model of the thermal management system, this research demonstrates that the model can dynamically estimates the junction temperature profile of the semiconductor devices in response to a changing torque demand profile for the motor drive system. This capability enables continuous monitoring of the module's operational time and cumulative stress induced on the devices to compute accumulated remaining lifetime or time-to-failure (TTF). This study provides an architectural framework for the HIL system with high-fidelity component models of multiple physical domains, allowing simulation of dynamic behaviors of a closely-coupled motor drive system. The advanced real-time computation and measurement functionalities of the HIL system allow for both dynamic lifetime calculations based on simulated data and aggregate lifetime predictions utilizing historical data. Moreover, this paper details an algorithm that not only computes cumulative damage but also synthesizes these data into a comprehensive aggregated lifetime metric. This methodology can enhance the maintenance scheduling strategies and operational reliability of semiconductor devices in critical applications, ultimately extending their service life while optimizing performance.
A fixed beam array antenna approach is proposed to meet the omnidirectional receiving and transmitting requirements of LST (Large Space Telescope). The proposed method uses an antenna of known performance and scales the size and frequency to conform with the LST 1/5-th scale model. The simplification that the approach provides over switching antenna elements on board the LST or switching from the ground by frequency diversity makes it worthy of consideration against the factors of performance, cost, reliability, and operations complexity. For LST applications, the system capabilities, requirements, and margins are summarized. The areas to be covered by further investigations into the proposed LST antenna are noted.
Realistic simulation of satellite communication systems and evaluation of satellite networking schemes require emulation of the systems's users. A laboratory model of a Ka-band satellite-switched time-division multiple-access (SS-TDMA) communication network, referred to as the System Integration, Test, and Evaluation (SITE) project, uses special bit-error-rate (BER) test sets to simulate the transmitting and receiving users of a communication network. The bit-error-rate test sets contain circuit boards that can be modified to create a variety of interfaces to satellite system ground terminals.
An electrical power system for the Space Station was designed, developed and built. This system provides for electrical power generation, conditioning, storage, and distribution. The initial configuration uses photovoltaic power generation. The power system control is based on a hierarchical architecture to support the requirements of automation. In the preliminary design and technology development phase of the program, various modeling techniques and software tools were evaluated for the purpose of meeting the Space Station power system modeling requirements. Rocketdyne and LeRC jointly selected the EASY5 simulation software, developed by Boeing Computer Services, as a system level modeling tool. The application of the selected analytical modeling approach to represent the entire power system is described. Typical results of model predictions are also summarized. The equipment modeled includes solar arrays, dc to ac converters, resonant inverters, battery storage system, alternator, transmission line, switch gear, and system level microprocessor controls. During the advanced development phase of this program, several models were developed using this approach.
The parallel approach to speeding up simulation is studied, specifically the simulation of digital LSI MOS circuitry on the Intel iPSC/2 hypercube. The simulation algorithm is based on RSIM, an event driven switch-level simulator that incorporates a linear transistor model for simulating digital MOS circuits. Parallel processing techniques based on the concepts of Virtual Time and rollback are utilized so that portions of the circuit may be simulated on separate processors, in parallel for as large an increase in speed as possible. A partitioning algorithm is also developed in order to subdivide the circuit for parallel processing.
An electrical power system for the Space Station was designed, developed and built. This system provides for electrical power generation, conditioning, storage, and distribution. The initial configuration uses photovoltaic power generation. The power system control is based on a hierarchical architecture to support the requirements of automation. In the preliminary design and technology development phase of the program, various modeling techniques and software tools were evaluated for the purpose of meeting the Space Station power system modeling requirements. Rocketdyne and LeRC jointly selected the EASY5 simulation software, developed by Boeing Computer Services, as a system level modeling tool. The application of the selected analytical modeling approach to represent the entire power system is described. Typical results of model predictions are also summarized. The equipment modeled includes solar arrays, dc to ac converters, resonant inverters, battery storage system, alternator, transmission line, switch gear, and system level microprocessor controls. During the advanced development phase of this program, several models were developed using this approach.
The ARPANET began operations in 1969 with four nodes as an experiment in resource sharing among computers. It has evolved into a worldwide research network of over 60,000 nodes, influencing the design of other networks in business, education, and government. It demonstrated the speed and reliability of packet-switching networks. Its protocols have served as the models for international standards. And yet the significance of the ARPANET lies not in its technology, but in the profound alterations networking has produced in human practices. Network designers must now turn their attention to the discourses of scientific technology, business, education, and government that are being mixed together in the milieux of networking, and in particular the conflicts and misunderstandings that arise from the different world views of these discourses.
In this paper, we examine the problem associated with abruptly mixing boundary conditions in the context of a two-dimensional semiconductor device simulator. Explicitly, this paper addresses the transition between an ohmic-type Dirichlet condition and a passivated Neumann boundary. In the traditional setting, the details or the transition between the two boundary types are not addressed and an abrupt transition is assumed. Subsequently, the calculated observables (most notably the potential) exhibit discontinuous derivatives near the surface at the point where the boundary type switches. This paper proposes an alternative condition which models the progression between the two boundary types through the use of a finite length, smoothed boundary whereby the numerical discontinuities are eliminated. The physical and mathematical basis for this smoothed boundary condition is discussed and examples of the technique's implementation given. It is found that the proposed boundary condition is numerically efficient and can be implemented in pre-existing device simulators with relative ease.
Mars 2020, the next planned U.S. rover mission to land on Mars, is based on the design of the successful 2012 Mars Science Laboratory (MSL) mission. Mars 2020 retains most of the entry, descent, and landing (EDL) sequences of MSL, including the closed-loop entry guidance scheme based on the Apollo guidance algorithm. However, unlike MSL, Mars 2020 will trigger the parachute deployment and descent sequence on range trigger rather than the previously used velocity trigger. This difference will greatly reduce the landing ellipse sizes. Additionally, the relative contribution of each models to the total ellipse sizes have changed greatly due to the switch to range trigger. This paper considers the effect on trajectory dispersions due to changing the trigger schemes and the contributions of these various models to trajectory and EDL performance.
This paper reviews site diversity concepts and models and presents the results of a site diversity experiment, in which radiometers were used to measure attenuation on earth-space paths, performed at Columbus, Ohio, for a period of one year. Attenuation statistics are presented first in the form of the joint probability density function of attenuation at the two sites. From these are derived the cumulative two-dimensional distribution of attenuation at both sites, the cumulative distribution of attenuation at each site, the effective cumulative distribution of attenuation for a diversity system that always switches to the better of two signals, and the effective cumulative distribution of attenuation for a system with maximal-ratio signal combining. The switched-system diversity gain is compared with Hodge's predictive model, and the diversity improvement is compared with Boithias' model. Fade-duration and interfade-interval statistics are also presented for each site and for systems that employ switching and maximal-ratio combining. Rain-rate and interrainfall interval statistics are also included.
Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.
Cold load pickup (CLPU) phenomenon is identified as the persistent power inrush upon a sudden load pickup after an outage. Under the active distribution system (ADS) paradigm, where distributed energy resources (DERs) are extensively installed, the decreased outage duration can induce a strong interdependence between CLPU pattern and load pickup decisions. In this paper, we propose a novel modelling technique to tractably capture the decision-dependent uncertainty (DDU) inherent in the CLPU process. Subsequently, a two-stage stochastic decision-dependent service restoration (SDDSR) model is constructed, where first stage searches for the optimal switching sequences to decide step-wise network topology, and the second stage optimizes the detailed generation schedule of DERs as well as the energization of switchable loads. Further, to tackle the computational burdens introduced by mixed-integer recourse, the progressive hedging algorithm (PHA) is utilized to decompose the original model into scenario-wise subproblems that can be solved in parallel. The numerical test on modified IEEE 123-node test feeders has verified the efficiency of our proposed SDDSR model and provided fresh insights into the monetary and secure values of DDU quantification.
Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.
Synthetic Input Data and Team Results for the GO Competition Challenge 3 for Events 1 - 4 and the Sandbox, along with problem and format descriptions and code to validate data and solutions, are available here. Data for industry scenarios will not be made public. The Grid Optimization (GO) Competition Challenge 3 focused on the security-constrained optimal power flow (SCOPF) problem. It is part of a continuing effort begun with Challenges 1 and 2, to successfully discover, develop, and test innovative and disruptive software solutions for critical energy challenges and to overcome existing barriers. The broader goal of the of the GO Competition is to accelerate the development of transformational and disruptive methods for solving problems related to the electric power grid and to provide a transparent, fair, and comprehensive evaluation of new solution methods. Challenge 3 used multiperiod dynamic markets, including advisory models for extreme weather events, day-ahead markets, and the real-time markets with an extended look-ahead. In Event 4, whose submission window was August 31-September 4, 2023, 14 teams solved for the objective values of 669 scenarios (39 scenarios required solutions both with and without line switching being allowed). The 591 synthetic scenarios from 9 network models (3.6 GB) are available here. Ten teams were funded to participate and 7 won prizes totaling $2,400,000. The largest prize ($550,000) went to Mississippi State University. An additional $600,000 was awarded in Event 3 (6/15-16/2023). No prizes were awarded in Events 1 (1/25-27/2023) or 2 (4/13-14/2023). For more information on the competition and challenge see the "GO Competition Challenge 3 Information" resource below.
The article investigates the impacts of four often-neglected factors on the loss model of a GaN-based full-bridge inverter: parasitic capacitance of the devices, dynamics of junction temperature (Tj) under time-varying power dissipation (Ploss), case temperature estimation, and detailed considerations of the passive components. Procedures to calculate the converter loss considering the above factors are proposed and implemented. A 4.5-kW hard-switching inverter prototype using gallium nitrite (GaN) high-electron-mobility transistors is used to experimentally demonstrate the impact of each factor on the converter loss model. Furthermore, it is found that the accuracy of a converter loss model is mainly affected by the passive components at the light load condition, whereas the thermal and loss models of the active components become the major factors as the output power increases. The results show that after considering the above factors, the converter loss discrepancy between calculation and measurement can be reduced from 30.6 W (28%) to 2.5 W (less than 3%) at heavy load (Po = 4.5 kW), while at the light load condition (Po = 500 W), it is reduced from 3.9 W (28%) to 2.6 W (16%). Furthermore, the difference between simulated and measured case temperature of the GaN devices is within 6 °C.
Results of switching behavior of the improper ferroelectric LuFeO 3 are presented. Here, using a model set of films prepared under controlled chemical and growth-rate conditions, it is shown that defects can reduce the quasi-static switching voltage by up to 40% in qualitative agreement with first-principles calculations. Switching studies show that the coercive field has a stronger frequency dispersion for the improper ferroelectrics compared to a proper ferroelectric such as PbTiO 3 . It is concluded that the primary structural order parameter controls the switching dynamics of such improper ferroelectrics.
A dynamic simulation model to describe vegetative growth of plants, for which some functions and parameter values have been estimated previously by optimization search techniques and numerical experimentation based on data from constant temperature experiments, is validated under conditions of changing temperatures. To test the predictive capacity of the model, dry matter accumulation in the leaves, stems, and roots of tobacco plants (Nicotiana tabacum L.) was measured at 2- or 3-day intervals during a 5-week period when temperatures in controlled-environment rooms were programmed for changes at weekly and daily intervals and in ascending or descending sequences within a range of 14 to 34 degrees C. Simulations of dry matter accumulation and distribution were carried out using the programmed changes for experimental temperatures and compared with the measured values. The agreement between measured and predicted values was close and indicates that the temperature-dependent functional forms derived from constant-temperature experiments are adequate for modelling plant growth responses to conditions of changing temperatures with switching intervals as short as 1 day.