At least 343 records · Page 19

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗

Advancing Superconducting Magnet Diagnostics for Future Colliders

Future colliders will operate at increasingly high magnetic fields pushing limits of electromagnetic and mechanical stress on the conductor [1]. Understanding factors affecting superconducting (SC) magnet performance in challenging conditions of high mechanical stress and cryogenic temperatures is only possible with the use of advanced magnet diagnostics. Diagnostics provide a unique observation window into mechanical and electromagnetic processes associated with magnet operation, and give essential feedback to magnet design, simulations and material research activities. Development of novel diagnostic capabilities is therefore an integral part of next-generation magnet development. In this paper, we summarize diagnostics development needs from a prospective of the US Magnet Development Program (MDP), and define main research directions that could shape this field in the near future.

43 PARTICLE ACCELERATORS↗

The Large Hadron–Electron Collider at the HL-LHC

The Large Hadron–Electron Collider (LHeC) is designed to move the field of deep inelastic scattering (DIS) to the energy and intensity frontier of particle physics. Exploiting energy-recovery technology, it collides a novel, intense electron beam with a proton or ion beam from the High-Luminosity Large Hadron Collider (HL-LHC). The accelerator and interaction region are designed for concurrent electron–proton and proton–proton operations. This report represents an update to the LHeC’s conceptual design report (CDR), published in 2012. It comprises new results on the parton structure of the proton and heavier nuclei, QCD dynamics, and electroweak and top-quark physics. It is shown how the LHeC will open a new chapter of nuclear particle physics by extending the accessible kinematic range of lepton–nucleus scattering by several orders of magnitude. Due to its enhanced luminosity and large energy and the cleanliness of the final hadronic states, the LHeC has a strong Higgs physics programme and its own discovery potential for new physics. Building on the 2012 CDR, this report contains a detailed updated design for the energy-recovery electron linac (ERL), including a new lattice, magnet and superconducting radio-frequency technology, and further components. Challenges of energy recovery are described, and the lower-energy, high-current, three-turn ERL facility, PERLE at Orsay, is presented, which uses the LHeC characteristics serving as a development facility for the design and operation of the LHeC. An updated detector design is presented corresponding to the acceptance, resolution, and calibration goals that arise from the Higgs and parton-density-function physics programmes. This paper also presents novel results for the Future Circular Collider in electron–hadron (FCC-eh) mode, which utilises the same ERL technology to further extend the reach of DIS to even higher centre-of-mass energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade Project

Here as part of the U.S. contribution to the HL-LHC Accelerator Upgrade Project (AUP), Fermilab is designing and building cold masses suitable for use in the LHC interaction regions. The cold mass provides a vacuum-tight helium enclosure for the magnets. Two magnets are aligned both axially and in cross section at Fermilab based on survey and warm magnetic measurements. Bus work and instrumentation is added. A welded stainless steel vacuum-tight shell surrounds the two magnets, and the structure is prepared for insertion into the cryostat. This paper summarizes the design of the cold mass including alignment, bus work, weld details, and instrumentation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Small-Aperture Cos-theta Dipole Insert Coil Based on Bi2212 Rutherford Cable and Stress Management Structure

The U.S. Magnet Development Program (US-MDP) is developing high-field accelerator magnets with magnetic fields beyond the limits of Nb3Sn technology based on high temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212). However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are substantial in high-field accelerator magnets. To prevent large degradation of the Bi2212 coils and achieve the required field quality, an innovative design which provides turn positioning during coil fabrication and operation and manage azimuthal and radial strains/stresses in the coil has been proposed at FNAL. This paper describes the development of a small-aperture two-layer Bi2212 dipole coil with stress management. The main parameters of the Bi2212 wire and Rutherford cable, the design of coil stress management structure and its plastic model, the coil mechanical analysis in the dipole mirror configuration are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

43 PARTICLE ACCELERATORS↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

Cryogenic Design and Thermal Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The Electron Ion Collider (EIC) physics program utilizes a 2.0 T superconducting magnet at the heart of its ePIC detector system. This approximately 3.5 m long and 2.84 m diameter warm bore magnet has a 20 tons cold mass which is conduction-cooled using liquid helium at 4.5 K. A closed loop active thermosiphon system is chosen to facilitate the cooling and to maintain a minimum of 2 K temperature margin on the peak operating temperature (4.7 K) of the superconductor. Here, this paper presents the cryogenic design of the cooling system and the thermal analysis of the solenoid. A Computational fluid dynamics (CFD) model was developed to quantify the performance of the two–phase closed thermosiphon system and predict the temperature gradient on the cold mass.

Gopinath, Sandesh [Thomas Jefferson National Accel↗

Fluid-phase helium: Shock-compression experiments, quantum molecular dynamics simulations, and development of an equation of state

Helium (He) plays a critical role in numerous areas ranging from the study of celestial objects like brown dwarfs and gas giants to modern-day technologies like nuclear energy and rocket propulsion. For many of these applications, it is essential to have a reliable equation of state (EOS) for He that yields an accurate representation of its thermodynamic behavior. To help constrain and develop such EOS models, we have performed a series of shock-compression experiments on cryogenic liquid He to pressures exceeding 100 GPa using a magnetically accelerated flyer plate on Sandia National Laboratories' Z-machine. We have also performed quantum molecular dynamics simulations that are consistent with our shock measurements. None of the previously available EOSs agree with our experimental and simulation results, motivating the development of a fluid-phase He EOS that we present in this study. Here, we show that our EOS yields good agreement with published data that span temperatures and pressures encountered across a diverse array of applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The 2.0 T superconducting solenoid magnet (MARCO) being designed to be built for the EIC central detector (ePIC). Here, the magnet consists of three set of coil in a vacuum impregnated coil pack. Each coil pack consists of a total 554 turns winding wrapped with 6 layers of winding per coil. The coil case assembly is cooled by supercritical helium at 4.6 K. This manuscript presents quench analysis carried out on the magnet system along with the conductor stability. For the normal operation the magnet at 4.6 K and at normal operating current, the quench evaluation is carried out at 4.7 K for design assessment. The quench analysis carried out using commercial multi-physics FEA tool along an equivalent single coil quench model and the requirements for the magnet protection is also presented.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Wind-tunnel simulation of store jettison with the aid of magnetic artificial gravity

A method employed in the simulation of jettison of stores from aircraft involving small scale wind-tunnel drop tests from a model of the parent aircraft is described. Proper scaling of such experiments generally dictates that the gravitational acceleration should ideally be a test variable. A method of introducing a controllable artificial component of gravity by magnetic means has been proposed. The use of a magnetic artificial gravity facility based upon this idea, in conjunction with small scale wind-tunnel drop tests, would improve the accuracy of simulation. A review of the scaling laws as they apply to the design of such a facility is presented. The design constraints involved in the integration of such a facility with a wind tunnel are defined. A detailed performance analysis procedure applicable to such a facility is developed. A practical magnet configuration is defined which is capable of controlling the strength and orientation of the magnetic artificial gravity field in the vertical plane, thereby allowing simulation of store jettison from a diving or climbing aircraft. The factors involved in the choice between continuous or intermittent operation of the facility, and the use of normal or superconducting magnets, are defined.

Stephens, T.↗

Magnetic Field Optimization of an In-Vacuum Undulator at NSLS-II Transactions on Applied Superconductivity

A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1 st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. Furthermore, the device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. We describe here the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.

43 PARTICLE ACCELERATORS↗

Bi-Filar Coil Winding for Fast Quench Protection

As superconducting magnet technology is pushed towards higher performance, energy density and total stored energy follow exponentially. Protecting magnets becomes substantially more challenging with traditional methods being stretched to their limits. New technologies such as CLIQ (Coupling Loss Induced Quench) promise to provide a robust method to protect advanced magnets, however they become inductance limited in large magnet strings or at low field, leading to more complex configurations. A technique to substantially reduce this limitation and improve response time is presented, by winding coils in a bifilar fashion and connecting them in series for typical operation, while providing an anti-parallel connection for quasi-zero-inductance in a protection case. This allows for extremely high di/dt. The concept is then demonstrated on a small REBCO coil.

43 PARTICLE ACCELERATORS↗

Investigation of hot-spots due to trapped flux in niobium superconducting radiofrequency cavities

One of the significant sources of residual losses in superconducting radio-frequency cavities is magnetic flux trapped during the cool-down due to the incomplete Messier effect. If the trapped vortices are non-uniformly distributed on the cavity surface, the temperature mapping revealed the “hotspots” at the location of high density of pinned vortices. Here, we performed a rf test on 1.3 GHz single cell cavity with the combination of the temperature mapping system. The temperature mapping reveled the development of the hot spots with the increase in rf field inside the cavity. When magnetic field is trapped locally on the surface of cavity, the hot-spots strength increase rapidly, showing the direct correlation of vortex induced hot spot and corresponding rf loss.

Accelerator Physics↗

Dynamic Aperture of the PIP-II Accumulator Ring (PAR)

The Proton Improvement Plan-II (PIP-II) will include a superconducting linear accelerator which will accelerate H- ions to 800MeV, at an intensity never seen before. A proposed PIP-II Accumulator Ring (PAR) can reduce the injection losses to the booster, enhance the ramp up of the Long Baseline Neutrino Facility (LBNF) and support experiments in Dark Sector Physics. When the beam is circulating in PAR at its full intensity, it will then be transferred to the Booster via single turn injection. Strong PAR focusing results in larger phase advances, shorter focal lengths and higher machine tunes, which creates robust beam envelope control. Particles will be able to survive modest excursions from the elliptical phase-space trajectories of linear optics, and any loss of particles would be due to reduced dynamic aperture. The values for tunes and chromaticities are flexible and will continue to evolve as the lattice matures. Since there will be non-linear terms impacting the particles’ trajectories, tracking will include realistic magnetic field errors and installation alignment errors to determine the dynamic aperture as a function of the machine tunes. This will allow us to determine the optimum operating point in phase-space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron Activity (Secondary Electron & Field Emission ) Suppression by Magnetic Field Placed on the Surface of Metals And Dielectric [Slides]

Secondary electron emission happens when the surface is exposed to an oscillating electromagnetic field. It has extremely dangerous effect when resonance condition of this oscillating field and higher SEY conditions are met. The dependence of the secondary electron on primary electron energy is shown in the figure. This multiplication effect on the number of electrons in oscillating electromagnetic field is called multipacting. The problem with multipacting exist in many scientific fields like LHC, ISS, ITER involving particle accelerator, space science and fusion research. In high intensity proton rings this multiplies electron get trapped inside the potential created by proton beam called electron cloud. In High power microwave sources, rf couplers and rf window to couple the power also hugely affected by multipacting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RHIC Recovery Review Report [See also: RHIC Recovery Review - Hybrid Meeting (11/28/2023) - Indico.bnl.gov]

Just after 12:30 PM on August 1, 2023, the RHIC superconducting magnet quench system triggered and consequently the energy dump resistors were switched into the blue ring quad and dipole circuits and the interaction region DX dipole heaters were switched on. This was a spurious trip (there was no actual quench) and was not unusual as the outdoor summer temperature often caused the quench detectors to cause such trips. The collider control room notified the on-duty cryogenics technical staff of the quench trip. A short time later building 1004B cryogenic low-helium and valve box insulation vacuum failure alarms were observed. The cryogenics technical staff observed the cryo-relief line from the blue ring valve box was exhausting helium outside the building.

43 PARTICLE ACCELERATORS↗

Multi-mode Analysis of Surface Losses in a Superconducting Microwave Resonator in High Magnetic Fields

This paper reports on a surface impedance measurement of a niobium titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to $10\,{\rm T}$). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple $TM$ cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment (ADMX), because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.