Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strain gage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Evaluation of Load Analysis Methods for NASAs GIII Adaptive Compliant Trailing Edge Project

The Air Force Research Laboratory (AFRL), NASA Armstrong Flight Research Center (AFRC), and FlexSys Inc. (Ann Arbor, Michigan) have collaborated to flight test the Adaptive Compliant Trailing Edge (ACTE) flaps. These flaps were installed on a Gulfstream Aerospace Corporation (GAC) GIII aircraft and tested at AFRC at various deflection angles over a range of flight conditions. External aerodynamic and inertial load analyses were conducted with the intention to ensure that the change in wing loads due to the deployed ACTE flap did not overload the existing baseline GIII wing box structure. The objective of this paper was to substantiate the analysis tools used for predicting wing loads at AFRC. Computational fluid dynamics (CFD) models and distributed mass inertial models were developed for predicting the loads on the wing. The analysis tools included TRANAIR (full potential) and CMARC (panel) models. Aerodynamic pressure data from the analysis codes were validated against static pressure port data collected in-flight. Combined results from the CFD predictions and the inertial load analysis were used to predict the normal force, bending moment, and torque loads on the wing. Wing loads obtained from calibrated strain gages installed on the wing were used for substantiation of the load prediction tools. The load predictions exhibited good agreement compared to the flight load results obtained from calibrated strain gage measurements.

Aerodynamic Loads↗

Damage Tolerance Testing of a NASA TransHab Derivative Woven Inflatable Module

Current options for Lunar habitat architecture include inflatable habitats and airlocks. Inflatable structures can have mass and volume advantages over conventional structures. However, inflatable structures carry different inherent risks and are at a lower Technical Readiness Level (TRL) than more conventional metallic structures. One of the risks associated with inflatable structures is in understanding the tolerance to induced damage. The Damage Tolerance Test (DTT) is designed to study the structural integrity of an expandable structure. TransHab (Figure 1) was an experimental inflatable module developed at the NASA/Johnson Space Center in the 1990 s. The TransHab design was originally envisioned for use in Mars Transits but was also studied as a potential habitat for the International Space Station (ISS). The design of the TransHab module was based on a woven design using an Aramid fabric. Testing of this design demonstrated a high level of predictability and repeatability with analytical predictions of stresses and deflections. Based on JSC s experience with the design and analysis of woven inflatable structures, the Damage Tolerance Test article was designed and fabricated using a woven design. The DTT article was inflated to 45 psig, representing 25% of the ultimate burst pressure, and one of the one-inch wide longitudinal structural members was severed by initiating a Linear Shaped Charge (LSC). Strain gage measurements, at the interface between the expandable elements (straps) and the nonexpandable metallic elements for pre-selected longitudinal straps, were taken throughout pressurization of the module and strap separation. Strain gage measurements show no change in longitudinal strap loading at the bulkhead interface after strap separation indicating loads in the restraint layer were re-distributed local to the damaged area due to the effects of friction under high internal pressure loading. The test completed all primary objectives with better than expected results. This paper will discuss space inflatable structures, damage tolerance analysis, test results, and applicability to the Lunar architecture.

Edgecombe, John↗

Thermogravimetric study of oxidation of a PdCr alloy used for high-temperature sensors

In this study, the oxidation of Pd-13 weight percent Cr, a candidate alloy for high-temperature strain gages, was investigated by thermogravimetry. Although the bulk alloy exhibits linear electrical resistivity versus temperature and stable resistivity at elevated temperatures, problems attributed to oxidation occur when this material is fabricated into strain gages. In this work, isothermal thermogravimetry (TG) was used to study the oxidation kinetics. Results indicate that the oxidation of Pd-13 weight percent Cr was approximately parabolic in time at 600 C but exhibited greater passivation from 700 to 900 C. At 1100 C, the oxidation rate again increased.

Boyd, Darwin L.↗

Experimental and analytical evaluation of the effects of simulated engine inlets on the blade vibratory stresses of the SR-3 model prop-fan

A cooperative wind tunnel test program, referred to as GUN-3, had been conducted previously to assess the effect of inlet configuration and location on the inlet face pressure recovery and inlet drag in the presence of a high-speed advanced turboprop. These tests were conducted with the inlets located just downstream of the SR-3 model Prop-Fan, a moderately swept, eight-bladed 62.2 cm (24.5 inch) diameter advanced, high-speed turboprop model fabricated from titanium. During these tests, two blades of the SR-3 model Prop-Fan were strain gaged to measure the vibratory blade stresses occurring during the inlet aerodynamic test program. The purpose of the effort reported herein was to reduce and analyze the test results related to the vibratory strain gage measurements obtained. Three inlet configurations had been tested. These were: (1) single scoop, (2) twin scoop, and (3) annular. Each of the three inlets was tested at a position just behind the rotor. The single scoop inlet was also tested at a position further aft. Tests were also done without an inlet. These results emphasize the importance of avoiding critical speeds in the continuous operating range.

Bansal, Prem N.↗

Investigation of a free-tip rotor configuration for research on spanwise life distributions and wake velocity surveys of a semi-span wing with a discontinuous twist

A wind tunnel test was conducted in the NASA Ames 7 x 10 Foot Wind Tunnel to investigate the lift distribution on a semi-span wing with a discontinuous change in spanwise twist. The semi-span wing had a tip with an adjustable pitch angle independent on the inboard section pitch angle simulating the free-tip rotor blade when its free-tip is at a deflected position. The spanwise lift distribution over the wing and the tip were measured and three component velocity surveys behind the wing were obtained with a three dimensional laser Doppler velocimeter (LV) with the wing at one angle of attack and the tip deflected at different pitch angles. A six component internal strain gage balance was also used to measure total forces and moments on the tip. The three dimensional lift was computed from the two dimensional life distributions obtained from the LV and from the strain gage balance. The results from both experimental methods are shown to be in agreement with predictions made by a steady, three dimensional panel code, VSAERO.

Fortin, Paul↗

Spanwise lift distributions and wake velocity surveys of a semi-span wing with a discontinuous twist

A wind tunnel test was conducted in the NASA-Ames 7 x 10 ft wind tunnel to investigate the lift distribution on a semispan wing with a discontinuous change in spanwise twist. The semispan wing had a tip with an adjustable pitch angle independent on the inboard section pitch angle simulating the free tip rotor blade when its free tip is at a deflected position. The spanwise lift distribution over the wing and the tip were measured and three component velocity surveys behind the wing were obtained with a 3-D laser Doppler velocimeter (LV) with the wing at one angle of attack and the tip deflected at different pitch angles. A six-component internal strain gage balance was also used to measure total forces and moments on the tip. The 3-D lift was computed from the 2-D lift distributions obtained from the LV and from the strain gage balance. The results from both experimental methods are shown to be in agreement with predictions made by a steady, 3-D panel code, VSAERO.

Kumagai, Hiroyuki↗

Miniature telemetry system accurately measures pressure

Miniature, low power, telemetry system that can be used with commercially available strain gage pressure transducers accurately measures pressure with a small implantable pressure cell and transmitter. The system has been used to date only with pressure transducers, but the circuit is equally applicable to any measurement using a strain gage sensor.

Fryer, T. B.↗

Dynamic measurements of gear tooth friction and load

As part of a program to study fundamental mechanisms of gear noise, static and dynamic gear tooth strain measurements were made on the NASA gear-noise rig. Tooth-fillet strains from low-contact ratio-spur gears were recorded for 28 operating conditions. A method is introduced whereby strain gage measurements taken from both the tension and compression sides of a gear tooth can be transformed into the normal and frictional loads on the tooth. This technique was applied to both the static and dynamic strain data. The static case results showed close agreement with expected results. For the dynamic case, the normal-force computation produced very good results, but the friction results, although promising, were not as accurate. Tooth sliding friction strongly affected the signal from the strain gage on the tensionside of the tooth. The compression gage was affected by friction to a much lesser degree. The potential of the method to measure friction force was demonstrated, but further refinement will be required before this technique can be used to measure friction forces dynamically with an acceptable degree of accuracy.

Rebbechi, Brian↗

Real time control for NASA robotic gripper

Control laws (in some optimal sense) are being developed for the gripper/nut runner end effector. Control laws for the gripper and nut runner portions of the end effector may be developed independently since these two systems are decoupled. A hybrid force/position controller will be used for both the gripper and nut runner. The development of the gripper controller is explained. Sensory data available to the controller is obtained from an array of strain gages as well as a linear potentiometer. Applying well known optimal control theoretic principles, the control which minimizes the transition time between positions is obtained. In addition, a robust force control scheme is developed to contend with the strain gage drift caused by extreme temperature variations encountered in space.

Salter, Carole A.↗

Matching of Apparent-Strain Characteristics

Strain gages are temporarily bonded to surface of test block. Apparent strain is recorded in excursion to -190 degrees C, and gages are disbonded following heating to elevated temperature. Matching strain gages for cryogenic use has several advantages. Initial accuracy for cryogenic transducers is greatly improved, less apparent-strain correction wire is required and there are smaller errors due to loop data caused by long pieces of correction wire.

Moore, T. C.↗

Spin test of turbine rotor

Experimental data are presented for the tangential and radial stresses in the disks of the 36,000 horsepower, 4000 rpm turbine for the M-1 engine oxidizer turbopump. The two-stage Curtis turbine is a special light-weight design utilizing thin conical disks with hollow sheet metal blades attached by electron-beam welding techniques. The turbine was fabricated from Inconel 718, a nickel-chromium alloy. The stresses were obtained by strain-gage measurements using a slip-ring assembly to transmit the electrical signals. Measurements were made at different rotative speeds and different thermal loads. In addition to presenting test data, the report describes test equipment, design of associated hardware, test procedures, instrumentation, and tests for the selection and calibration of strain gages.

Vavra, M. H.↗

Advanced high temperature static strain sensor development

An examination was made into various techniques to be used to measure static strain in gas turbine liners at temperatures up to 1150 K (1600 F). The methods evaluated included thin film and wire resistive devices, optical fibers, surface acoustic waves, the laser speckle technique with a heterodyne readout, optical surface image and reflective approaches and capacitive devices. A preliminary experimental program to develop a thin film capacitive device was dropped because calculations showed that it would be too sensitive to thermal gradients. In a final evaluation program, the laser speckle technique appeared to work well up to 1150 K when it was used through a relatively stagnant air path. The surface guided acoustic wave approach appeared to be interesting but to require too much development effort for the funds available. Efforts to develop a FeCrAl resistive strain gage system were only partially successful and this part of the effort was finally reduced to a characterization study of the properties of the 25 micron diameter FeCrAl (Kanthal A-1) wire. It was concluded that this particular alloy was not suitable for use as the resistive element in a strain gage above about 1000 K.

Hulse, C. O.↗

Experimental investigation of Mach 3 cruise heating simulations on a representative wing structure for flight loads measurement

Radiant heating experiments were performed in the laboratory on an instrumented multispar wing structure to investigate: (1) how accurately the structural temperatures of a Mach 3 cruise-flight profile could be simulated, (2) what the effects of the heating and heating inaccuracies would be on the responses of strain-gage bridges installed on the structure, and (3) how these responses would affect flight loads measurements. Test temperatures throughout the structure agreed well with temperatures calculated for a Mach 3 profile. In addition, temperatures produced by two identical tests were repeatable to less than + or -6 K deg. Thermally induced strain-gage-bridge responses were large enough to be detrimental to a high-speed flight loads program with a goal of establishing aerodynamic loads (exclusive of thermal loads). It was shown that heating simulation can be used effectively for thermal calibration (that is, to provide corrections for a high-temperature environment), and that thermal calibration may not be needed if the simulation data are used to carefully select bridges and load equations.

Fields, R. A.↗

A Universal Algorithm for the Detection of Bi-directional Gage Output Characteristics

A universal algorithm was developed that may be used to assess the bi-directional characteristics of the gage outputs of a wind tunnel strain-gage balance. The algorithm assumes that balance loads and gage outputs are described in the design format of the balance. It can also be applied to balance calibration data that is processed by using either the Iterative Method or the Non-Iterative Method. The algorithm uses an estimate of the bi-directional part of a gage output at load capacity as input. In addition, the statistical significance of the principle absolute value term in the regression model of either the gage output or the related primary load component is determined. A gage output is assumed to be bi-directional if two conditions are fulfilled: the bi-directional part of the output at load capacity exceeds 0.5 percent of the maximum output at load capacity; the p-value of the principle absolute value term of the regression model of the balance data is less than the threshold of 0.001. Data from the calibration of two six-component force balances and one five-component semi-span balance are used to illustrate the application of the universal detection algorithm.

wind tunnel test↗

Dynamic response characteristics of two transport models tested in the National Transonic Facility

This paper documents recent experiences with measuring the dynamic response characteristics of a commercial transport and a military transport model during full scale Reynolds number tests in the National Transonic Facility. Both models were limited in angle of attack while testing at full scale Reynolds number and cruise Mach number due to pitch or stall buffet response. Roll buffet (wing buzz) was observed for both models at certain Mach numbers while testing at high Reynolds number. Roll buffet was more severe and more repeatable for the military transport model at cruise Mach number. Miniature strain-gage type accelerometers were used for the first time for obtaining dynamic data as a part of the continuing development of miniature dynamic measurements instrumentation for cryogenic applications. This paper presents the results of vibration measurements obtained for both the commercial and military transport models and documents the experience gained in the use of miniature strain gage type accelerometers.

Young, Clarence P., Jr.↗

Measurement component technology. Volume 1: Cryogenic pressure measurement technology, high pressure flange seals, hydrogen embrittlement of pressure transducer material, close coupled versus remote transducer installation and temperature compensation of pressure transducers

The results are presented of an investigation into the availability and performance capability of measurement components in the area of cryogenic temperature, pressure, flow and liquid detection components and high temperature strain gages. In addition, technical subjects allied to the components were researched and discussed. These selected areas of investigation were: (1) high pressure flange seals, (2) hydrogen embrittlement of pressure transducer diaphragms, (3) The effects of close-coupled versus remote transducer installation on pressure measurement, (4) temperature transducer configuration effects on measurements, and (5) techniques in temperature compensation of strain gage pressure transducers. The purpose of the program was to investigate the latest design and application techniques in measurement component technology and to document this information along with recommendations for upgrading measurement component designs for future S-2 derivative applications. Recommendations are provided for upgrading existing state-of-the-art in component design, where required, to satisfy performance requirements of S-2 derivative vehicles.

Hayakawa, K. K.↗

Lamb Wave Response of Fatigued Composite Samples

Composite materials are being more widely used today by aerospace, automotive, sports equipment, and a number of other commercial industries because of their advantages over conventional metals. Composites have a high strength-to-weight ratio and can be constructed to meet specific design needs. Composite structures are already in use in secondary parts of the Douglas MD-11 and are planned to be used in the new MD-12X. Plans also exist for their use in primary and secondary structures on the Boeing 777. Douglas proposed MD-XX may also incorporate composite materials into primary structures such as the wings and tail. Use of composites in these structures offers weight savings, corrosion resistance, and improved aerodynamics. Additionally, composites have been used to repair cracks in many B-1Bs where traditional repair techniques were not very effective. Plans have also been made to reinforce all of the remaining B-1s with composite materials. Verification of the structural integrity of composite components is needed to insure safe operation of these aerospace vehicles. One aspect of the use of these composites is their response to fatigue. To track this progression of fatigue in aerospace structures, a convenient method to nondestructively monitor this damage needs to be developed. Traditional NDE techniques used on metals are not easily adaptable to composites due to the inhomogeneous and anisotropic nature of these materials. Finding an effective means of nondestructively monitoring fatigue damage is extremely important to the safety and reliability of such structures. Lamb waves offer one method of evaluating these composite materials. As a material is fatigued, the modulus degrades. Since the Lamb wave velocity can be related to the modulus of the material, an effective tool can be developed to monitor fatigue damage in composites by measuring the velocity of these waves. In this work, preliminary studies have been conducted which monitor fatigue damage in composite samples using strain gage measurements as well as Lamb wave velocity measurements. A description of the test samples is followed by the results of two different measurements of Lamb wave velocity. The first technique is a contact measurement done at a single frequency, while the second involves an immersion study of Lamb waves in which dispersion curves are obtained. The results of the Lamb wave monitoring of fatigue damage is compared to the damage progression measured by strain gages. The final section discusses the results and conclusions.

Seale, Michael↗

Electro optical system to measure strains at high temperature

The measurement of strains at temperatures of the order of 1000 C has become a very important field of research. Technological advances in areas such as the analysis of high speed aircraft structures and high efficiency thermal engines require operational temperatures of this order of magnitude. Current techniques for the measurement of strains, such as electrical strain gages, are at the limit of their useful range and new methods need to be developed. Optical techniques are very attractive in this type of application because of their noncontacting nature. Holography is of particular interest because a minimal preparation of the surfaces is required. Optoelectronics holography is specially suited for this type of application, from the point of view of industrial use. There are a number of technical problems that need to be overcome to measure strains using holographic interferometry at high temperatures. Some of these problems are discussed, and solutions are given. A specimen instrumented with high temperature strains gages is used to compare the results of both technologies.

Sciammarella, Cesar A.↗