Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Discrete-Element and Material-Point Method (DEM and MPM) Based Solvers for Sustainable Technologies

We present the use of discrete element method (DEM) and material point method (MPM) in three relevant green technology applications that include biomass feedstock handling, lithium-ion battery manufacturing, and high-pressure reverse osmosis. Our open-source DEM and MPM solvers are developed using performance portable grid and particle management library, AMReX, thus enabling superior performance on NVIDIA and AMD GPUs with > 100 million particles. Our DEM solver resolves the motion of individual particles in a granular system and includes a bonded sphere method for modeling non-spherical particles along with Hertzian and liquid bridge-based contact models. We simulate highly variable biomass feedstock flows in large-scale hoppers for biofuel production and electrode calendering in battery manufacturing using DEM. Our simulations predict flow blockage in large scale biomass hoppers and electrode microstructure variations, thus providing valuable information for biofuel and battery manufacturers, respectively. The second half of the talk will be on MPM and its application towards pore resolved simulations of reverse osmosis membranes under compressive loads. We present a validation study of our MPM simulations with membrane microscopy imaging thus providing useful insights on membrane stability under high pressure conditions. We also present a spectral stability analysis of using linear hat, quadratic and cubic spline basis in MPM indicating regions of numerical stability.

BIOMASS FUELS,MATHEMATICS AND COMPUTING↗

Real-Space Infrared Spectroscopy of Ferroelectric Domain Walls in Multiferroic h -(Lu,Sc)FeO 3

Herein we employ synchrotron-based near-field infrared spectroscopy to image the phononic properties of ferroelectric domain walls in hexagonal ( h ) Lu 0.6 Sc 0.4 FeO 3 , and we compare our findings with a detailed symmetry analysis, lattice dynamics calculations, and prior models of domain-wall structure. Rather than metallic and atomically thin as observed in the rare-earth manganites, ferroelectric walls in h -Lu 0.6 Sc 0.4 FeO 3 are broad and semiconducting, a finding that we attribute to the presence of an A -site substitution-induced intermediate phase that reduces strain and renders the interior of the domain wall nonpolar. Mixed Lu/Sc occupation on the A site also provides compositional heterogeneity over micron-sized length scales, and we leverage the fact that Lu and Sc cluster in different ratios to demonstrate that the spectral characteristics at the wall are robust even in different compositional regimes. This work opens the door to broadband imaging of physical and chemical heterogeneity in ferroics and represents an important step toward revealing the rich properties of these flexible defect states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Multi-orbital-phase and Multiband Characterization of Exoplanetary Atmospheres with Reflected Light Spectra

Direct imaging of widely separated exoplanets from space will obtain their reflected light spectra and measure atmospheric properties. Previous calculations have shown that a change in the orbital phase would cause a spectral signal, but whether this signal may be used to characterize the atmosphere has not been shown. We simulate starshade-enabled observations of the planet 47 UMa b, using the present most realistic simulator Starshade Imaging Simulation Toolkit for Exoplanet Reconnaissance to estimate the uncertainties due to residual starlight, solar glint, and exozodiacal light. We then use the Bayesian retrieval algorithm ExoReL{sup R} to determine the constraints on the atmospheric properties from observations using a Roman- or Habitable Exoplanet Observatory (HabEx)-like telescope, comparing the strategies to observe at multiple orbital phases or in multiple wavelength bands. With a ∼20% bandwidth in 600–800 nm on a Roman-like telescope, the retrieval finds a degenerate scenario with a lower gas abundance and a deeper or absent cloud than the truth. Repeating the observation at a different orbital phase or at a second 20% wavelength band in 800–1000 nm, with the same integration time and thus degraded signal-to-noise ratio (S/N), would effectively eliminate this degenerate solution. Single observation with a HabEx-like telescope would yield high-precision constraints on the gas abundances and cloud properties, without the degenerate scenario. These results are also generally applicable to high-contrast spectroscopy with a coronagraph with a similar wavelength coverage and S/N, and can help design the wavelength bandwidth and the observation plan of exoplanet direct-imaging experiments in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Unprecedented Fluorophore Photostability Enabled by Low‐Loss Organic Hyperbolic Materials

Abstract The dynamics of photons in fluorescent molecules plays a key role in fluorescence imaging, optical sensing, organic photovoltaics, and displays. Photobleaching is an irreversible photodegradation process of fluorophores, representing a fundamental limitation in relevant optical applications. Chemical reagents are used to suppress the photobleaching rate but with exceptionally high specificity for each type of fluorophore. Here, using organic hyperbolic materials (OHMs), an optical platform to achieve unprecedented fluorophore photostability without any chemical specificity is demonstrated. A more than 500‐fold lengthening of the photobleaching lifetime and a 230‐fold increase in the total emitted photon counts are observed simultaneously. These exceptional improvements solely come from the low‐loss hyperbolic dispersion of OHM films and the large resultant Purcell effect in the visible spectral range. The demonstrated OHM platform may open up a new paradigm in nanophotonics and organic plasmonics for super‐resolution imaging and the engineering of light–matter interactions at the nanoscale.

Lee, Yeon Ui↗

Coherent terahertz radiation with 2.8-octave tunability through chip-scale photomixed microresonator optical parametric oscillation

High-spectral-purity frequency-agile room-temperature sources in the terahertz spectrum are foundational elements for imaging, sensing, metrology, and communications. Here we present a chip-scale optical parametric oscillator based on an integrated nonlinear microresonator that provides broadly tunable single-frequency and multi-frequency oscillators in the terahertz regime. Through optical-to-terahertz down-conversion using a plasmonic nanoantenna array, coherent terahertz radiation spanning 2.8-octaves is achieved from 330 GHz to 2.3 THz, with ≈20 GHz cavity-mode-limited frequency tuning step and ≈10 MHz intracavity-mode continuous frequency tuning range at each step. By controlling the microresonator intracavity power and pump-resonance detuning, tunable multi-frequency terahertz oscillators are also realized. Furthermore, by stabilizing the microresonator pump power and wavelength, sub-100 Hz linewidth of the terahertz radiation with 10 –15 residual frequency instability is demonstrated. The room-temperature generation of both single-frequency, frequency-agile terahertz radiation and multi-frequency terahertz oscillators in the chip-scale platform offers unique capabilities in metrology, sensing, imaging and communications.

42 ENGINEERING↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

Electrically Reconfigurable Liquid Metal Nanophotonic Platform for Color Display and Imaging

Dynamically tunable optical materials and device architectures are essential for future photonic technologies, yet conventional solid metals lack the intrinsic tunability required for advanced functionalities. Gallium-based liquid metals (LMs) present an appealing alternative thanks to their distinctive mechanical and optical properties; however, their practical integration in tunable photonic elements remains largely unexplored. Here, in this study, an electrochemically controlled nanophotonic platform is demonstrated that integrates a dynamically reconfigurable LM ground plane with gold nanoantenna arrays within a microfluidic system, enabling precise and reversible modulation of optical resonances across the visible to mid-infrared spectral ranges. By employing moderate operational voltages (1.5–3.0 V), real-time tuning of high-resolution structural color patterns is achieved through nanoscale control of the interfacial gap between the LM and Au nanoantennas. This innovative platform facilitates electrically programmable, high-contrast color patterns suitable for dynamic optical displays, secure anti-counterfeiting labels, and imaging applications. Additionally, this platform enables tunable mid-infrared spectral responses, which may be utilized for chemical and biological sensing applications. This versatile integrated LM-based nanophotonic platform opens new paths toward multifunctional, actively tunable/reconfigurable photonic device and system technologies.

Imaging↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Entanglement Enabled Intensity Interferometry of different wavelengths of light

Highlights: • We use quantum entanglement to erase the color of photons for a new imaging method. • Can achieve higher resolution imaging by accessing hidden phase information. • We detail practical experimental designs to implement our theoretical protocols. We propose methods to perform intensity interferometry of photons having two different wavelengths. Distinguishable particles typically cannot interfere with each other, but we overcome that obstacle by processing the particles via entanglement and projection so that they lead to the same final state at the detection apparatus. Specifically, we discuss how quasi-phase-matched nonlinear crystals can be used to convert a quantum superposition of light of different wavelengths onto a common wavelength, while preserving the phase information essential for their meaningful interference. We thereby gain access to a host of new observables, which can probe subtle frequency correlations and entanglement. Further, we generalize the van Cittert–Zernike formula for the intensity interferometry of extended sources, demonstrate how our proposal supports enhanced resolution of sources with different spectral character, and suggest potential applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

Tip-Enhanced Raman Nanospectroscopy of Smooth Spherical Gold Nanoparticles

We record nanoscale-resolved chemical images of thiobenzonitrile (TBN)-functionalized smooth gold nanospheres on silicon via tip-enhanced Raman (TER) nano-spectroscopy. The recorded images trace the nascence of the familiar doughnut-shaped scattering profile of nanoparticles on silicon at its origin (the particle surface), which appears as a horseshoe-shaped scattering pattern under our experimental conditions. The local optical field maps are in agreement with their simulated finite-difference time-domain analogues. Analysis of the recorded spectra with the aid of ab initio molecular dynamics-based Raman spectral simulations further suggests that optical rectification and molecular charging take place throughout the course of atomic force microscopy-based TER nanoscale chemical imaging.

Bhattarai, Ashish↗

CFM-ID 4.0: More Accurate ESI MS/MS Spectral Prediction and Compound Identification

In the field of metabolomics, mass spectrometry (MS) is the method most commonly used for identifying and annotating metabolites. As this typically involves matching a given MS spectrum against an experimentally acquired reference spectral library, this approach is limited by the coverage and size of such libraries (which typically number in the thousands). These experimental libraries can be greatly extended by predicting the MS spectra of known chemical structures (which number in the millions) to create computational reference spectral libraries. To facilitate the generation of predicted spectral reference libraries we developed CFM-ID, a computer program that can accurately predict ESI-MS/MS spectrum for a given compound structure. CFM-ID is one of the best-performing methods for compound-to-mass-spectrum prediction, and also one of the top tools for in silico mass-spectrum-to-compound identification. This work improves CFM-ID’s ability to predict ESI-MS/MS spectra from compounds by: (1) learning parameters from features based on the molecular topology, (2) adding a new approach to ring cleavage that models such cleavage as a sequence of simple chemical bond dissociations and (3) expanding its hand-written rule-based predictor to cover more chemical classes, including acylcarnitines, acylcholines, flavonols, flavones, flavanones, and flavonoid glycosides. We demonstrate that this new version of CFM-ID (version 4.0) is significantly more accurate than previous CFM-ID versions, in terms of both EI-MS/MS spectral prediction and compound identification. CFM-ID 4.0 is available at http://cfmid4.wishartlab.com/ as a webservice and docker images can be downloaded at https://hub.docker.com/r/wishartlab/cfmid

Wang, Fei↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Third-order photon correlations extract single-nanocrystal multiexciton properties in solution

Colloidal semiconductor nanocrystals are considered promising materials for high-flux optical applications, including lasing, light-emitting diodes, biological imaging, and quantum optics. In high-flux applications, multiexcitons can significantly contribute to emission, influencing its brightness, spectral purity, and kinetics. As a result, understanding and controlling multiexciton emission in colloidal nanocrystal materials is of the utmost importance. In the past, single-nanocrystal photon correlation methods have been applied to understand biexciton and triexciton efficiencies, lifetimes, and spectra. While powerful, such methods suffer from user selection bias and require stable emission from single nanocrystals. To compensate for this shortcoming, second-order correlation methods were developed to extract sample-averaged biexciton properties from a solution of nanocrystals. Until now, however, the analogous third-order solution photon correlation methods remained unexplored. In this work, we present a pair of third-order photon correlation techniques to obtain the sample-averaged single-nanocrystal triexciton quantum yield and lifetime in a solution-phase experiment. These techniques derive from the relationship between the Poisson probability of nanocrystal photon absorption and the intrinsic probability of nanocrystal photon emission. We validate the theoretical background of these techniques by creating a numerical model to simulate the diffusion and emission of many nanocrystals in solution. Our simulations confirm that the average triexciton quantum yield and triexciton lifetime can be extracted from a solution of nanocrystals. These techniques will enable researchers to gain a better understanding of the fundamental multiexciton properties of colloidal nanocrystals.

Horowitz, Jonah R. [Massachusetts Institute of Tec↗

Spectrally filtered ps–ns emission dynamics of atmospheric-pressure nanosecond pulsed plasmas

The temporal dynamics of atmospheric-pressure nanosecond pulsed plasma discharges in a pin-to-pin electrode configuration are studied using streak-camera line imaging of the interelectrode gap with a time resolution as short as ~25 ps. Discharge emission initiates homogeneously throughout the interelectrode gap with no detectable streamer propagation and then temporally decays in two distinct phases. Plasma emission bands attributed to various electronic transitions are tracked for single discharges in air and N 2 . Spectral filtering of the excited molecular states reveals that the N 2 (C–B) and N 2 (B–A) emission bands evolve in distinct early and late phases, respectively, with a time separation of ~15–20 ns. Furthermore, significant differences in the temporal dynamics of plasma discharges in air and N2 are observed. High levels of excited-state atomic oxygen and NO appear after the initial decay of the N 2 (C) state and coincide primarily with the latter phases of plasma evolution in air environments. From temporal traces of discharge emission, the formation and relaxation timescales of the electronically excited states of N 2 are quantified in pure N2 and air environments with sub-nanosecond resolution. The streak-OES (optical emission spectroscopy) technique enables quantitative time-resolved studies of key chemical species for model validation in ultra-short-pulsed plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emission-line Data Cubes of the HH 32 Stellar Jet

We analyze data cubes of over 60 emission lines in the HH 32 stellar jet acquired with the Keck Cosmic Web Imager (KCWI). The data cover the less explored blue portion of the spectrum between 3586 and 6351 Å and have both high spectral (R ∼ 10,000) and spatial (≲1″) resolution. The study includes all three major ionization states of oxygen, three Balmer lines, multiple lines of Fe ii and Fe iii, and the first data cubes ever acquired for important unblended diagnostic lines such as He ii λ4686, Ca i λ3933, and Mg i] λ4571. The data cubes generally sort according to excitation and have a relatively continuous progression from the highest-excitation ions (He ii, O iii) through the intermediate-excitation ions (O i and H i) to the lowest-excitation ions (Ca ii and Mg i). Merging the KCWI cubes with Hubble Space Telescope images leads to several new insights about the flow, including evidence for bow shocks, partial bow shocks, spur shocks, Mach disks, jet deflection shocks, a wiggling jet, and potential shock precursors. The most surprising result is that one of the velocity components of Fe ii in the Mach disk suddenly increases in flux relative to other lines by a factor of two, implying that the Mach disk vaporizes dust in the jet. Hence, jets must accelerate or entrain dust to speeds of over 300 km s{sup −1} without destroying the grains.

79 ASTRONOMY AND ASTROPHYSICS↗