Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sparse sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

HOW IMPORTANT IS THE DARK MATTER HALO FOR BLACK HOLE GROWTH?

In this paper, we examine whether the properties of central black holes in galactic nuclei correlate with their host dark matter halos. We analyze the entire sample of galaxies where black hole mass, velocity dispersion {sigma}, and asymptotic circular velocity V{sub c} have all been measured. We fit M{sub BH}-{sigma} and M{sub BH}-V{sub c} to a power law, and find that in both relationships the scatter and slope are similar. This model-independent analysis suggests that although the black hole masses are not uniquely determined by dark matter halo mass, when considered for the current sample as a whole, the M{sub BH}-V{sub c} correlation may be as strong (or as weak) as M{sub BH}-{sigma}. Although the data are sparse, there appears to be more scatter in the correlation for both {sigma} and V{sub c} at the low-mass end. This is not unexpected given our current understanding of galaxy and black hole assembly. In fact, there are several compelling reasons that account for this: (1) supermassive black hole (SMBH) formation is likely less efficient in low-mass galaxies with large angular momentum content, (2) SMBH growth is less efficient in low-mass disk galaxies that have not experienced major mergers, and (3) dynamical effects, such as gravitational recoil, increase scatter preferentially at the low-mass end. Therefore, the recent observational claim of the absence of central SMBHs in bulgeless, low-mass galaxies, or deviations from the correlations defined by high-mass black holes in large galaxies today is, in fact, predicated by current models of black hole growth. We show how this arises as a direct consequence of the coupling between dark matter halos and central black holes at the earliest epochs.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Report: Algorithm and Implementation for Quasispecies Abundance Inference with Confidence Intervals from Metagenomic Sequence Data

This report describes the design and implementation of an algorithm for estimating relative microbial abundances, together with confidence limits, using data from metagenomic DNA sequencing. For the background behind this project and a detailed discussion of our modeling approach for metagenomic data, we refer the reader to our earlier technical report, dated March 4, 2014. Briefly, we described a fully Bayesian generative model for paired-end sequence read data, incorporating the effects of the relative abundances, the distribution of sequence fragment lengths, fragment position bias, sequencing errors and variations between the sampled genomes and the nearest reference genomes. A distinctive feature of our modeling approach is the use of a Chinese restaurant process (CRP) to describe the selection of genomes to be sampled, and thus the relative abundances. The CRP component is desirable for fitting abundances to reads that may map ambiguously to multiple targets, because it naturally leads to sparse solutions that select the best representative from each set of nearly equivalent genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Regulatory Technology Development Plan - Sodium Fast Reactor. Mechanistic Source Term - Metal Fuel Radionuclide Release

The development of an accurate and defensible mechanistic source term will be vital for the future licensing efforts of metal fuel, pool-type sodium fast reactors. To assist in the creation of a comprehensive mechanistic source term, the current effort sought to estimate the release fraction of radionuclides from metal fuel pins to the primary sodium coolant during fuel pin failures at a variety of temperature conditions. These release estimates were based on the findings of an extensive literature search, which reviewed past experimentation and reactor fuel damage accidents. Data sources for each radionuclide of interest were reviewed to establish release fractions, along with possible release dependencies, and the corresponding uncertainty levels. Although the current knowledge base is substantial, and radionuclide release fractions were established for the elements deemed important for the determination of offsite consequences following a reactor accident, gaps were found pertaining to several radionuclides. First, there is uncertainty regarding the transport behavior of several radionuclides (iodine, barium, strontium, tellurium, and europium) during metal fuel irradiation to high burnup levels. The migration of these radionuclides within the fuel matrix and bond sodium region can greatly affect their release during pin failure incidents. Post-irradiation examination of existing high burnup metal fuel can likely resolve this knowledge gap. Second, data regarding the radionuclide release from molten high burnup metal fuel in sodium is sparse, which makes the assessment of radionuclide release from fuel melting accidents at high fuel burnup levels difficult. This gap could be addressed through fuel melting experimentation with samples from the existing high burnup metal fuel inventory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A bi-channel aided stitching of atomic force microscopy images

Microscopy is an essential tool in scientific research, enabling the visualization of structures at micro- and nanoscale resolutions. However, the field of microscopy often encounters limitations in field-of-view (FOV), restricting the amount of sample that can be imaged in a single capture. To overcome this limitation, image stitching techniques have been developed to seamlessly merge multiple overlapping images into a single, high-resolution composite. The images collected from microscope need to be optimally stitched before accurate physical information can be extracted from post analysis. However, the existing stitching tools either struggle to stitch images together when the microscopy images are feature sparse or cannot address all the transformations of images when performing image stitching. To address these issues, we propose a bi-channel aided feature-based image stitching method and demonstrate its use on Atomic Force Microscopy (AFM) generated Pantoea sp. YR343 biofilm and PTO thin film sample images as experimental data. The topographical channel image of AFM data captures the morphological details of the sample, and a stitched topographical image is desired for researchers. We utilize the amplitude and phase channels of AFM data to maximize the matching features and to estimate the position of the original topographical images and show that the proposed bi-channel aided stitching method outperforms the traditional direct stitching approach in AFM topographical image stitching task. Here, we demonstrated the application on AFM, but similar approaches could be employed of optical microscopy with brightfield and fluorescence channels. We believe this proposed workflow can serve as a valuable augmentation strategy for microscopy image stitching tasks and will benefit the experimentalist to avoid erroneous analysis and discovery due to incorrect stitching.

Atomic force microscopy↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

Sparse coding of pathology slides compared to transfer learning with deep neural networks

Background Histopathology images of tumor biopsies present unique challenges for applying machine learning to the diagnosis and treatment of cancer. The pathology slides are high resolution, often exceeding 1GB, have non-uniform dimensions, and often contain multiple tissue slices of varying sizes surrounded by large empty regions. The locations of abnormal or cancerous cells, which may constitute a small portion of any given tissue sample, are not annotated. Cancer image datasets are also extremely imbalanced, with most slides being associated with relatively common cancers. Since deep representations trained on natural photographs are unlikely to be optimal for classifying pathology slide images, which have different spectral ranges and spatial structure, we here describe an approach for learning features and inferring representations of cancer pathology slides based on sparse coding. Results We show that conventional transfer learning using a state-of-the-art deep learning architecture pre-trained on ImageNet (RESNET) and fine tuned for a binary tumor/no-tumor classification task achieved between 85% and 86% accuracy. However, when all layers up to the last convolutional layer in RESNET are replaced with a single feature map inferred via a sparse coding using a dictionary optimized for sparse reconstruction of unlabeled pathology slides, classification performance improves to over 93%, corresponding to a 54% error reduction. Conclusions We conclude that a feature dictionary optimized for biomedical imagery may in general support better classification performance than does conventional transfer learning using a dictionary pre-trained on natural images.

59 BASIC BIOLOGICAL SCIENCES↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

A Distributed-Memory Package for Dense Hierarchically Semi-Separable Matrix Computations Using Randomization

In this paper, we present a distributed-memory library for computations with dense structured matrices. A matrix is considered structured if its off-diagonal blocks can be approximated by a rank-deficient matrix with low numerical rank. Here, we use Hierarchically Semi-Separable (HSS) representations. Such matrices appear in many applications, for example, finite-element methods, boundary element methods, and so on. Exploiting this structure allows for fast solution of linear systems and/or fast computation of matrix-vector products, which are the two main building blocks of matrix computations. The compression algorithm that we use, that computes the HSS form of an input dense matrix, relies on randomized sampling with a novel adaptive sampling mechanism. We discuss the parallelization of this algorithm and also present the parallelization of structured matrix-vector product, structured factorization, and solution routines. The efficiency of the approach is demonstrated on large problems from different academic and industrial applications, on up to 8,000 cores. Finally, this work is part of a more global effort, the STRUctured Matrices PACKage (STRUMPACK) software package for computations with sparse and dense structured matrices. Hence, although useful on their own right, the routines also represent a step in the direction of a distributed-memory sparse solver.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Bayesian Calibration Framework with Embedded Model Error for Model Diagnostics

We study the utility and performance of a Bayesian model error embedding construction in the context of molecular dynamics modeling of metallic alloys, where we embed model error terms in existing interatomic potential model parameters. To alleviate the computational burden of this approach, we propose a framework combining likelihood approximation and Gaussian process surrogates. Here we leverage sparse Gaussian process techniques to construct a hierarchy of increasingly accurate but more expensive surrogate models. This hierarchy is then exploited by multilevel Markov chain Monte Carlo methods to efficiently sample from the target posterior distribution. We illustrate the utility of this approach by calibrating an interatomic potential model for a family of gold-copper alloys. In particular, this case study highlights effective means for dealing with computational challenges with Bayesian model error embedding in large-scale physical models, and the utility of embedded model error for model diagnostics.

Bayesian inference↗

Development of a Heavy-Duty Electric Vehicle Integration and Implementation (HEVII) Tool

As demand for consumer electric vehicles (EVs) has drastically increased in recent years, manufacturers have been working to bring heavy-duty EVs to market to compete with Class 6-8 diesel-powered trucks. Many high-profile companies have committed to begin electrifying their fleet operations, but have yet to implement EVs at scale due to their limited range, long charging times, sparse charging infrastructure, and lack of data from in-use operation. Thus far, EVs have been disproportionately implemented by larger fleets with more resources. To aid fleet operators, it is imperative to develop tools to evaluate the electrification potential of heavy-duty fleets. However, commercially available tools, designed mostly for light-duty vehicles, are inadequate for making electrification recommendations tailored to a fleet of heavy-duty vehicles. The main challenge is that light-duty tools do not estimate real-time vehicle mass, a factor that has a disproportionate impact on the energy consumption of large commercial vehicles. The Heavy-Duty Electric Vehicle Integration and Implementation (HEVII) tool advances the state of the art in evaluating electrification potential and infrastructure requirements for fleets of commercial vehicles. In this work, the HEVII tool is demonstrated with non-uniformly sampled telematics data from an existing fleet to assess the suitability for electrification of each individual vehicle, determine optimal locations for charging infrastructure to support a fleet of EVs and analyze associated costs. Payload mass is predicted using sparse ground-truth data for all input drive cycles and an initial data analysis is conducted to assess the characteristics driving behaviors and energy consumption of the fleet using an adaptable vehicle model. Battery size requirements are determined by applying a novel charger placement algorithm to maximize routes that are viable for EVs and balance time delays with infrastructure development costs. This work details and demonstrates the different aspects of the HEVII tool, presenting preliminary results from an example use case.

ADVANCED PROPULSION SYSTEMS↗

ASGarD: Adaptive Sparse Grid Discretization

Many areas of science exhibit physical processes that are described by high dimensional partial differential equations (PDEs), e.g., the 4D, 5D and 6D models describing magnetized fusion plasmas, models describing quantum chemistry, or derivatives pricing. Such problems are affected by the so-called “curse of dimensionality” where the number of degrees of freedom (or unknowns) required to be solved for scales as N D where N is the number of grid points in any given dimension D. A simple, albeit naive, 6D example is demonstrated in the left panel of Figure 1. With N = 1000 grid points in each dimension, the memory required just to store the solution vector, not to mention forming the matrix required to advance such a system in time, would exceed an exabyte - and also the available memory on the largest of supercomputers available today. The right panel of Figure 1 demonstrates potential savings for a range of problem dimensionalities and grid resolution. While there are methods to simulate such high-dimensional systems, they are mostly based on Monte-Carlo methods, which rely on a statistical sampling such that the resulting solutions include noise. Since the noise in such methods can only be reduced at a rate proportional to $\sqrt{N_p}$ where N p is the number of Monte-Carlo samples, there is a need for continuum, or grid/mesh-based methods for high-dimensional problems, which both do not suffer from noise and bypass the curse of dimensionality. We present a simulation framework that provides such a method using adaptive sparse grids.

97 MATHEMATICS AND COMPUTING↗

Adaptive sparse polynomial dimensional decomposition for derivative-based sensitivity

In this report applications, such as the plasma-coupled combustion system we consider, derivative-based sensitivity indices (DSI) are known to have several advantages over Sobol's total sensitivity indices, especially for small sample sizes. Several properties of derivative-based sensitivity measures are leveraged to develop a new and efficient numerical approach to estimate them. It is based on computing the DSI measures by effectively cost-free Monte Carlo sampling of an adaptively constructed orthogonal polynomial surrogate with uncertain input parameters that can have arbitrary probability distributions. The adaptivity reduces the number of necessary model evaluations, which is demonstrated both in a constructed example (the Moon function) and in two plasma-combustion systems with up to 55 uncertain parameters. Unimportant parameters are successfully identified and neglected with a low number of model evaluations, which makes it an attractive non-intrusive approach when adjoint solutions are unavailable to provide sensitivity information.

42 ENGINEERING↗

Resolution enhancement of lung 4D-CT via group-sparsity

Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as quantitatively, the ability of their approach to achieve more accurate and better localized results over bicubic interpolation as well as a related state-of-the-art approach. The authors also show results on some datasets with tumor, to further emphasize the clinical importance of their method.Conclusions: The authors have proposed to improve the superior-inferior resolution of 4D-CT by estimating intermediate slices. The authors’ approach exploits neighboring constraints in the group-sparsity framework, toward the goal of achieving better localization and noise robustness. The authors’ results are encouraging, and positively demonstrate the role of group-sparsity for 4D-CT resolution enhancement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Bayesian Inference for Prediction

Performing rigorous predictive simulation necessitates that all available data be incorporated into the modeling process in order to accurately quantify uncertainties in predictions of the model. Statistical Bayesian inference is the most commonly used approach for incorporating data into uncertainty estimates. Statistical Bayesian inference uses data and an assumed error model to inform posterior distributions of model input variables and model discrepancies. An explicit characterization of the posterior distribution is not formed, but rather methods such as Markov chain Monte-Carlo (MCMC) are used to draw samples from the posterior. These samples are then used to evaluate statistics, such as integrals, of predicted quantities of interest (QoI). Recently the authors have developed an alternative reformulation of Bayesian inference based upon a measure-theoretic inversion technique. Unlike traditional statistical Bayesian inference, this reformulation allows us to directly interrogate the posterior distribution and, consequently, to generate samples from the posterior without MCMC. In this work we use forward propagation uncertainty quantification techniques to reduce the cost of approximating the posterior distribution. Specifically we investigate goal-oriented adaptive sparse grid approximation methods. These adaptive methods concentrate high-fidelity model evaluations in regions of the parameter space that both significantly contribute to the uncertainty in specified QoI and are informed by the available data. Numerical results are presented to compare our approach with the standard statistical Bayesian approach and to demonstrate the effectiveness of the goal-oriented adaptivity.

97 MATHEMATICS AND COMPUTING↗

Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer

Abstract The continued development of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma as an ion source for diverse, elemental/isotopic analysis applications continues. To this end, characterization of the capabilities in performing precise and accurate isotope ratio (IR) determinations is essential. Based on past experience with the Thermo Exactive Orbitrap mass analyzer, the LS-APGD was interfaced with this instrument for these tests. While the Orbitrap platform has demonstrated excellent mass resolution and accuracy in “organic” mass spectrometry (MS) applications, work using an Orbitrap for IR analysis is very sparse. These efforts build off previous work in this coupling, where the importance of a few of the LS-APGD discharge parameters and Orbitrap data acquisition methods on IR precision and accuracy were probed. Presented here are the results of a study that evaluated the analytical precision for natural uranium sample (assumed 235U/238U = 0.0072) determinations. The instrumental parameters evaluated include the number of microscans and scans making up a data acquisition set, uranium concentration/signal level, sample make-up, and Fourier transform digitization window. Ultimately, a precision of 0.41% relative standard deviation (RSD) can be achieved for a single determination, with a reproducibility of 1.63 %RSD over 10 separate analytical measurements. A preliminary study of matrix effects on IR measurements of U is presented, highlighting the importance of pre-mass selection before injection into the Orbitrap. The analytical system sensitivity is suggested with the ability to produce a calibration function having an R2 value of >0.99 over a range of 4 orders of magnitude of concentration (~1 – 1000 ng mL-1). These efforts demonstrate the very promising pairing of the LS-APGD ionization source and the Orbitrap, pointing as well to definitive paths forward to better utilize both components in high quality isotope ratio mass spectrometry (IRMS).

Environmental Molecular Sciences Laboratory↗

Facile hermetic TEM grid preparation for molecular imaging of hydrated biological samples at room temperature

Abstract Although structures of vitrified supramolecular complexes have been determined at near-atomic resolution, elucidating in situ molecular structure in living cells remains a challenge. Here, we report a straightforward liquid cell technique, originally developed for real-time visualization of dynamics at a liquid-gas interface using transmission electron microscopy, to image wet biological samples. Due to the scattering effects from the liquid phase, the micrographs display an amplitude contrast comparable to that observed in negatively stained samples. We succeed in resolving subunits within the protein complex GroEL imaged in a buffer solution at room temperature. Additionally, we capture various stages of virus cell entry, a process for which only sparse structural data exists due to their transient nature. To scrutinize the morphological details further, we used individual particle electron tomography for 3D reconstruction of each virus. These findings showcase this approach potential as an efficient, cost-effective complement to other microscopy technique in addressing biological questions at the molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

Model-measurement consistency and limits of bioaerosol abundance over the continental United States

Abstract. Due to low concentrations and chemical complexity, in situ observations of bioaerosol are geographically and temporally sparse, and this limits the accuracy of current emissions inventories. In this study, we apply a new methodology, including corrections for misidentification of mineral dust, to measurements of single particles over four airborne sampling campaigns to derive vertical profiles of bioaerosol over the continental United States. The new methodology is based on single-particle mass spectrometry (SPMS); it can extend historic datasets to include measurements of bioaerosol, it allows comparisons to other techniques, and it generally agrees with a global aerosol model. In the locations sampled, bioaerosols were at least a factor of 10 less abundant than mineral dust. Below 2 km, bioaerosol concentrations were measured between 6×103 and 2×104 m−3. Between 2 and 8 km, bioaerosol concentrations were between 0 and 2×104 m−3, and above 8 km, bioaerosol concentrations were between 0 and 1×103 m−3. Between 30 % and 80 % of single bioaerosol particles detected were internally mixed with dust. A direct comparison of the SPMS methodology with a co-located wideband integrated bioaerosol sensor (WIB) fluorescence sensor on a mountaintop site showed agreement to within a factor of 3 over the common size range.

54 ENVIRONMENTAL SCIENCES↗