Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spallation source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A new apparatus design for high temperature (up to 950 °C) quasi-elastic neutron scattering in a controlled gaseous environment

A design for a sample cell system suitable for high temperature Quasi-Elastic Neutron Scattering (QENS) experiments is presented. The apparatus was developed at the Spallation Neutron Source in Oak Ridge National Lab where it is currently in use. The design provides a special sample cell environment under controlled humid or dry gas flow over a wide range of temperature up to 950 °C. Using such a cell, chemical, dynamical, and physical changes can be studied in situ under various operating conditions. While the cell combined with portable automated gas environment system is especially useful for in situ studies of microscopic dynamics under operational conditions that are similar to those of solid oxide fuel cells, it can additionally be used to study a wide variety of materials, such as high temperature proton conductors. The cell can also be used in many different neutron experiments when a suitable sample holder material is selected. The sample cell system has recently been used to reveal fast dynamic processes in quasi-elastic neutron scattering experiments, which standard probes (such as electrochemical impedance spectroscopy) could not detect. In this work, we outline the design of the sample cell system and present results demonstrating its abilities in high temperature QENS experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Journey to Time-Variable Moment Tensors through Inversion of Acoustic and Seismoacoustic Data

We explore the capability of acoustic and seismoacoustic datasets to directly resolve a complex, time-variable source consisting of a buried mechanism, represented as a moment tensor, and a spall mechanism, represented as a vertical force at the surface. Traditionally, each component of a resolved moment tensor assumes one underlying source time function, which likely fails to capture the full evolution of a dynamic source, such as an explosion followed by slip on near-source joints or development of spallation. Specifically, we expand previous work to resolve a time-variable moment tensor using single-modality and joint-modality inversion frameworks through analysis of infrasound and seismoacoustic data recorded as part of the Source Physics Experiment Phase II: Dry Alluvium Geology (DAG). We investigate the impact of including signals from seismic-to-air coupling that are local to each infrasound sensor in comparison to mainly atmosphere-propagating acoustic signals, which occur from coupling of the wavefield from the subsurface to the atmosphere directly above the source. Additionally, we assess the ability of our inversion algorithm to fit observed infrasound data using a variety of time-variable source mechanisms. First, we consider the buried moment tensor source alone, which assumes that the determined Green’s functions incorporate effects from spallation or that the impact from spallation is minimal. Second, we examine the estimated buried moment tensor and vertical surface spallation as terms that must both be resolved in the inversion. Third, we assess the ability for an estimated vertical surface spallation source to fit the acoustic data on its own. Finally, we compare results from the joint inversion of both seismic geophone and infrasound acoustic data for the buried-only source compared to buried and spallation sources. Our results are a preliminary investigation into the applications of the inversion technique to recorded datasets and show the technique has limited capabilities using acoustic data alone. Instead, this method shows promise for seismic and seismoacoustic datasets to resolve the time-variable mechanisms of a buried source.

47 OTHER INSTRUMENTATION↗

H- ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced by spallation of liquid Hg due to bombardment of short (~1µs), intense (~35 A) pulses of protons delivered at 60 Hz from a storage ring which is fed by a high-intensity, 1 GeV H- LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50-60 mA of H- ions with a duty-factor of 6% for maintenance-free runs of ~120 days with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting these achievements: this report provides some historical highlights of this effort, describes our current ion source testing facilities, discusses the goals of the program and finally provides a snapshot of some of our ongoing R&D activities. In particular, we have recently simplified and improved the reliability of the plasma ignition gun for the external antenna ion source which is discussed in detail.

Welton, Robert F.↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building Neutron Scattering Infrastructure in Louisiana for Advanced Materials (Final Report)

The main objective of the Louisiana Consortium for Neutron Scattering (LaCNS) is to build a major neutron scattering infrastructure capable of treating both soft and hard materials. The goal is to create a sustainable effort having the quality, breadth, and depth necessary to produce competitive proposals including collaborative and center type proposals. Our scientific aim is to understand the role of coupling in emergent complex materials and its impact on the structure/property relationship and to explore how to tune the key couplings to guide the design of materials with the desired properties. This naturally includes building a base of users of the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) in Louisiana; to train highly talented graduate and post-doctoral students in synthesis, neutron scattering, and simulation and modeling techniques, thereby helping to produce the next generation of scientist who use neutron scattering techniques as a crucial part of their research. The goal of our hard matter program is to understand the interplay between spin, charge, orbital, and lattice degrees of freedom in carefully selected complex materials. We have made considerable progress on number of complex systems including the oxide Sr3(Ru1-xMnx)2O7 where short-range magnetic ordering with anisotropic spin texture is initiated at the metal-insulator transition that clearly indicates a strong spin-charge coupling. Another critical area is in quantum materials. For example, in the topological semimetal BaMnSb2, we found a 3D canted antiferromagnetic Weyl semimetal with a 2D electronic structure and a nontrivial Berry phase. In addition, in the hexagonal chiral Mn1/3NbS2 system, we found soliton/soliton and soliton/antisoliton domain walls where the application of small fields or small currents can be used to control nanoscopic magnetic domains where the control of domain walls is crucially important for information storage. In addition, chemical transformation investigations were performed on the VISION instrument at Spallation Neutron Source (SNS). The soft matter effort was focused on understanding the role of non-covalent interactions on the structure and dynamics of fluid-based soft matter. One key focus was on sequence-defined (SD) amphiphilic peptoid polymers that allow encoding of molecular interactions and thereby systematic investigations of how charge directs the solution self-assembly of amphiphilic polymers in water. Another important area was on the dynamics of lipids self-assembled into membranes for exploring the permeability and mechanical using both neutron spin echo (NSE) spectroscopy and quasielastic neutron scattering (QENS) to distinguished between viscoelasticity and permeability at the molecular scale. Overall, the LaCNS project was quite successful, generating 145 publications and 245 presentations. Our graduate and post-doctoral students were well trained resulting in positions in national laboratories (Oak Ridge National Laboratory (ORNL), Argonne National Laboratory and Los Alamos National Laboratory), major research universities, and industry. We also developed a uniaxial pressure cell along with ORNL for SNS. A critical goal of this project was to establish a foundation for competing nationally in federally funded research programs. To this end, we were quite successful in generating over twenty-two federally and non-federally funded grants including awards from NSF, DOE, and DOD, and two early career awards. Equally important, we were able to secure a key major piece of instrumentation via a large ARO grant for a state-of-the-art electron microscope.

36 MATERIALS SCIENCE↗

Evaluation of SNS Beamline Shielding Configurations using MCNPX Accelerated by ADVANTG

Shielding analyses for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory pose significant computational challenges, including highly anisotropic high-energy sources, a combination of deep penetration shielding and an unshielded beamline, and a desire to obtain well-converged nearly global solutions for mapping of predicted radiation fields. The majority of these analyses have been performed using MCNPX with manually generated variance reduction parameters (source biasing and cell-based splitting and Russian roulette) that were largely based on the analyst's insight into the problem specifics. Development of the variance reduction parameters required extensive analyst time, and was often tailored to specific portions of the model phase space. We previously applied a developmental version of the ADVANTG code to an SNS beamline study to perform a hybrid deterministic/Monte Carlo analysis and showed that we could obtain nearly global Monte Carlo solutions with essentially uniform relative errors for mesh tallies that cover extensive portions of the model with typical voxel spacing of a few centimeters. The use of weight window maps and consistent biased sources produced using the FW-CADIS methodology in ADVANTG allowed us to obtain these solutions using substantially less computer time than the previous cell-based splitting approach. While those results were promising, the process of using the developmental version of ADVANTG was somewhat laborious, requiring user-developed Python scripts to drive much of the analysis sequence. In addition, limitations imposed by the size of weight-window files in MCNPX necessitated the use of relatively coarse spatial and energy discretization for the deterministic Denovo calculations that we used to generate the variance reduction parameters. We recently applied the production version of ADVANTG to this beamline analysis, which substantially streamlined the analysis process. We also tested importance function collapsing (in space and energy) capabilities in ADVANTG. These changes, along with the support for parallel Denovo calculations using the current version of ADVANTG, give us the capability to improve the fidelity of the deterministic portion of the hybrid analysis sequence, obtain improved weight-window maps, and reduce both the analyst and computational time required for the analysis process.

43 PARTICLE ACCELERATORS↗

The {sup 237}Np(n,f) cross section at the CERN n-TOF facility

The {sup 237}Np(n,f) cross sections have been measured at the n-TOF facility relative to the {sup 235}U and {sup 238}U fission cross sections. The n-TOF spallation neutron source at CERN is characterized by a high intensity flux, an excellent time resolution and an extensive neutron energy range (from eV to GeV). A fast ionization chamber was used as a fission fragment detector with efficiency better than 97%. Preliminary {sup 237}Np(n,f) cross sections have been deduced in the energy range from 20 keV to 10 MeV and are found in good agreement with data from literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Matching an H{sup –} beam into a radio frequency quadrupole at Rutherford Appleton Laboratory

A major component of work being carried out to upgrade the ISIS spallation neutron source at Rutherford Appleton Laboratory (RAL) is the Front End Test Stand (FETS). FETS is aimed at improving the luminosity of the linac, and consists of a Penning ion source, Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ), and Medium Energy Beam Transport (MEBT). It may serve as a first part of the accelerator chain providing a 60 mA, 3 MeV H{sup –} beam up to a 10% duty cycle. The current output of the source and the transmission of the LEBT are reasonable, but there are issues with the alignment to provide a centred beam matched into the acceptance of the RFQ. Improvements have been made to the post acceleration to address this problem. Measurements with a collimated beam have been performed to understand the behaviour of the solenoids and steerer magnets. Comparing these results with simulations proved that, besides possible mechanical imperfections of the ion source and post acceleration assembly, agreement can only be achieved if the magnetic fields are distorted.

43 PARTICLE ACCELERATORS↗

A radial collimator for a time-of-flight neutron spectrometer

We have engineered and installed a radial collimator for use in the scattered beam of a neutron time-of-flight spectrometer at a spallation neutron source. The radial collimator may be used with both thermal and epithermal neutrons, reducing the detected scattering intensity due to material outside of the sample region substantially. The collimator is located inside of the sample chamber of the instrument, which routinely cycles between atmospheric conditions and cryogenic vacuum. The oscillation and support mechanism of the collimator allow it to be removed from use without breaking vacuum. We describe here the design and characterization of this radial collimator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On possibility of low-emittance high-energy muon source based on plasma wakefield acceleration

We report plasma wakefield acceleration (PWA) channels are characterized by very high accelerating gradients and very strong focusing fields. We propose to employ these properties for effective production of low emittance high energy muon beams, consider muon beam dynamics in the PWFA cell and analyze various options and potential of the PWA-based muon sources.

43 PARTICLE ACCELERATORS↗

Methods and Procedures for Shielding Analyses for the SNS

In order to provide radiologically safe Spallation Neutron Source operation, shielding analyses are performed according to Oak Ridge National Laboratory internal regulations and to comply with the Code of Federal Regulations. An overview of on-going shielding work for the accelerator facility and neutrons beam lines, methods, used for the analyses, and associated procedures and regulations is presented. Methods used to perform shielding analyses are described as well.

43 PARTICLE ACCELERATORS↗

In Situ Thermodynamics and Kinetics of Mixed-Valence Inorganic Crystal Formation

We have found that the established methods to discover and produce earth-abundant iron-containing active layers are very inefficient. The prospective new material iron silicon sulfide, Fe 2 SiS 4 , was previously only synthesized by slow reactions of metallic iron, silicon, and sulfur powders, resulting in poor yield. We found that using an ordered iron-silicon alloy as a feedstock results in a much faster reaction at a lower temperature. We could track this reaction using our unique in-situ X-ray diffractometer, which allows us to heat our encapsulated material up to 1000°C while providing a simultaneous picture of how the atoms in the structure rearrange. We are using this powerful new technique to search for new active layers and optimize their formation by creative use of more complex reagents. Our key accomplishments are mechanisms for improving synthesis, and new materials that result from them. We have demonstrated the utility of high-throughput, DOE-developed infrastructure, such as the Materials Project, to accelerate materials discovery and synthesis. We have pioneered new capabilities of user facilities, such as beamlines 6-BM, 17-BM, and 11-BM at the Advanced Photon Source (APS) and POWGEN and NOMAD at the Spallation Neutron Source.

36 MATERIALS SCIENCE↗

Neutron Studies of Tb2Mo2O7

We have used the new high energy resolution spectrometer (BaSiS), at the Spallation Neutron Source in Oak Ridge, to conclusively prove the existence of a low energy mode at 0.34(1) meV in the spin glass Tb{sub 2}Mo{sub 2}O{sub 7}. This mode is reminiscent of the excitation observed in the ordered phases of both Tb{sub 2}Ti{sub 2}O{sub 7} and Tb{sub 2}Sn{sub 2}O{sub 7}. The dynamical nature of the transition seen in the magnetization at {approx} 25 K suggests that this frustrated magnet shows a dynamic crossover between a high-temperature phase of poorly correlated, quickly relaxing spins to a low-temperature regime with much slower, short ranged spin correlations extending no further than to the next nearest neighbor. Existing theories explain the spin glass transition in terms of a phase transition and order parameters, and assume the existence of a distinct spin glass phase. There is no evidence for such a phase in Tb{sub 2}Mo{sub 2}O{sub 7}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

H- AND PROTON BEAM LOSS COMPARISON AT SNS SUPERCONDUCTING LINAC

A comparison of beam loss in the superconducting part (SCL) of the Spallation Neutron Source (SNS) linac for H- and protons is presented. During the experiment the nominal beam of negative hydrogen ions in the SCL was replaced by a proton beam created by insertion of a thin stripping carbon foil placed in the low energy section of the linac. The observed significant reduction in the beam loss for protons is explained by a domination of the intra beam stripping mechanism of the beam loss for H-. The details of the experiment are discussed, and a preliminary estimation of the cross section of the reaction H- + H- -> H- + H0 + e is presented. Earlier, a short description of these studies was presented in [1].

43 PARTICLE ACCELERATORS↗

CHALLENGES FOR THE SNS RING ENERGY UPGRADE

The Oak Ridge Spallation Neutron Source accumulator ring presently operates at a beam power of about 1 MW with a beam energy of about 910 MeV. A power upgrade is planned to increase the beam energy to 1.3 GeV. For the accumulator ring this mostly involves modifications to the injection and extraction sections. A variety of modifications to the existing injection section were necessary to achieve 1 MW, and the tools developed and the lessons learned from this work are now being applied to the design of the new injection section. This paper will discuss the tools and the lessons learned, and also present the design and status of the upgrades to the accumulator ring.

99 GENERAL AND MISCELLANEOUS↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectively reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.

43 PARTICLE ACCELERATORS↗

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE↗