Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Wet and dry plastic deposition data for western US National Atmospheric Deposition Program sites (2017-2019)

Raw plastic counts and calculated plastic deposition rates for 11 National Atmospheric Deposition Program (NADP) sites in the western USA recorded from 2017-2019. Samples were collected to determine plastic deposition rates in remote locations and identify the potential sources of plastic to the atmosphere. Samples were collected using an Aerochem Metrics Wet and Dry sampler. Wet deposition refers to the material retained on a 0.45-micron filter. Dry deposition refers to the dry only deposition collected using a Dry Side Insert (DSI) (Brahney et al. 2020). Plastics are identified as either fibers or particles (includes small colored films). Wet deposition rates are recorded weekly and dry plastic deposition rates are based on monthly sampling intervals. Sites included are Grand Canyon National Park (AZ03), Joshua Tree National Park (CA67), Rocky Mountain National Park (CO98), Niwot Ridge (CO02), Ashley National Forest (UT95), East River SFA (CO10)), Craters of the Moon National Park (ID03), Great Basin National Park (NV05), Canyonlands National Park (UT09), Bryce Canyon Nationa Park (UT99), and Wind River Range (WY06). Data collection is being published in collaboration with the Department of Energy's research project, "Constraining physical understanding of aerosol loading, biogeochemistry, and snowmelt hydrology from hillslope to watershed scale in the East River Scientific Focus Areas.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a coastal acoustic buoy for cetacean detections, bearing accuracy and exclusion zone monitoring

Abstract There is strong socio‐political support for offshore wind development in US territorial waters and construction is planned off several east coast states. Some of the planned development sites coincide with important habitat for critically endangered North Atlantic right whales. Both exclusion zones and passive acoustic monitoring are important tools for managing interactions between marine mammals and human activities. Understanding where animals are with respect to exclusion zones is important to avoid costly construction delays while minimizing the potential for negative impacts. Impact piling from construction of hundreds of offshore wind turbines likely require exclusion zones as large as 10 km. We have developed a three‐hydrophone passive acoustic monitoring system that provides bearing information along with marine mammal detections to allow for informed management decisions in real‐time. Multiple units form a monitoring system designed to determine whether marine mammal calls originate from inside or outside of an exclusion zone. In October 2021, we undertook a full system validation, with a focus on evaluating the detection range and bearing accuracy of the system with respect to right whale upcalls. Five units were deployed in Mid‐Atlantic waters and we played more than 3500 simulated right whale upcalls at known locations to characterize the detection function and bearing accuracy of each unit. The modelled results of the detection function error were then used to compare the effectiveness of a bearing‐based system to a single sensor that can only detect a signal but not ascertain directivity. Field trials indicated maximum detection ranges from 4–7.3 km depending on source and ambient noise levels. Simulations showed that incorporating bearing detections provide a substantial improvement in false alarm rates (6 to 12 times depending on number of units, placement and signal to noise conditions) for a small increase in the risk of missed detections inside of an exclusion zone (1%–3%). We show that the system can be used for monitoring exclusion zones and clearly highlight the value of including bearing estimation into exclusion zone monitoring plans while noting that placement and configuration of units should reflect anticipated ambient noise conditions.

17 WIND ENERGY↗

On the additivity of climate responses to the volcanic and solar forcing in the early 19th century

The early 19th century was the coldest period over the past 500 years, when strong tropical volcanic events and a solar minimum coincided. The 1809 unidentified eruption and the 1815 Tambora eruption happened consecutively during the Dalton minimum of solar irradiance; however, the relative role of the two forcing (volcano and solar) agents is still unclear. In this study, we examine the responses from a set of early 19th century simulations with combined and separated volcanic and solar forcing agents, as suggested in the protocol for the past1000 experiment of the Paleoclimate Modelling Intercomparison Project – Phase 4 (PMIP4). From 20-member ensemble simulations with the Max Planck Institute Earth system model (MPI-ESM1.2-LR), we find that the volcano- and solar-induced surface cooling is additive in the global mean/large scale, regardless of combining or separating the forcing agents. The two solar reconstructions (SATIRE (Spectral and Total Irradiance REconstruction-Millennia model) and PMOD (Physikalisch-Meteorologisches Observatorium Davos)) contribute to a cooling before and after 1815 of ~0.05 and ~0.15 K monthly average near-surface air cooling, respectively, indicating a limited solar contribution to the early 19th century cold period. The volcanic events provide the main cooling contributions, inducing a surface cooling that peaks at ~0.82 K for the 1809 event and ~1.35 K for Tambora. After the Tambora eruption, the temperature in most regions increases toward climatology largely within 5 years, along with the reduction of volcanic forcing. In the northern extratropical oceans, the temperature increases slowly at a constant rate until 1830, which is related to the reduction of seasonality and the concurrent changes in Arctic sea-ice extent. The albedo feedback of Arctic sea ice is found to be the main contributor to the Arctic amplification of the cooling signal. Several non-additive responses to solar and volcanic forcing happen on regional scales. In the atmosphere, the stratospheric polar vortex tends to strengthen when combining both volcano and solar forcing, even though the two forcing agents separately induce opposite-sign changes in stratospheric temperatures and zonal winds. In the ocean, when combining the two forcings, additional surface cold water propagates to the northern extratropics from the additional solar cooling in the tropics, which results in regional cooling along the propagation. Overall, this study not only quantifies the surface responses from combinations of the volcano and solar forcing, but also highlights the components that cannot be simply added from the responses of the individual forcing agents, indicating that a relatively small forcing agent (such as solar in early 19th century) can impact the response from the large forcing (such as the 1815 Tambora eruption) when considering regional climates.

54 ENVIRONMENTAL SCIENCES↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

Hardware-based Advanced Electromagnetic Transient Simulation for A Large-Scale PV Plant in Real Time Digital Simulator

Power electronics-based resources, such as high-voltage direct current (HVdc) substations, photovoltaic (PV) plants, wind plants, electric vehicle charging stations, and energy storage systems, are increasingly being integrated within the power grid. Recently, multiple reports have emphasized the necessity for high-fidelity electromagnetic transient (EMT) simulations of these large-scale power electronics-based resources to accurately understand their behavior in power grids. However, performing hardware-based EMT simulations with high-fidelity models for such large power electronics systems is challenging due to the small time-step requirements and the involvement of a large number of states. This paper presents the implementation of hardware-based high-fidelity EMT dynamic model of a large-scale PV plant, accomplished through custom model development using the specific-C language in real-time digital simulator hardware (RTDS) and software (RSCAD).

Choi, Jongchan↗

Challenges and Capabilities in Estimating Snow Mass Intercepted in Conifer Canopies With Tree Sway Monitoring

Snowpack accumulation in forested watersheds depends on the amount of snow intercepted in the canopy and its partitioning into sublimation, unloading, and melt. A lack of canopy snow measurements limits our ability to evaluate models that simulate canopy processes and predict snowpack. We tested whether monitoring changes in wind-induced tree sway is a viable technique for detecting snow interception and quantifying canopy snow water equivalent (SWE). Over a 6 year period in Colorado, we monitored hourly sway of two conifers, each instrumented with an accelerometer sampling at 12 Hz. We developed an approach to distinguish changes in sway frequency due to thermal effects on tree rigidity versus intercepted snow mass. Over 60% of days with canopy snow had a sway signal that could not be distinguished from thermal effects. However, larger changes in tree sway could not generally be attributed to thermal effects, and canopy snow was present 93%–95% of the time, as confirmed with classified PhenoCam imagery. Using sway tests, we converted changes in sway to canopy SWE, which were correlated with total snowstorm amounts from a nearby SNOTEL site (Spearman r = 0.72 to 0.80, p < 0.001). Greater canopy SWE was associated with storm temperatures between -7°C and 0°C and wind speeds less than 4 m s -1 . Lower canopy SWE prevailed in storms with lower temperatures and higher wind speeds. Monitoring tree sway is a viable approach for quantifying canopy SWE, but challenges remain in converting changes in sway to mass and distinguishing thermal and snow mass effects on tree sway.

54 ENVIRONMENTAL SCIENCES↗

Macro-physical Properties of Shallow Cumulus from Integrated ARM Observations (Final Report)

Fair-weather shallow cumuli (ShCu) play an important role in many climate-related processes. Irregular geometry of ShCu and their strong temporal and spatial variability make it challenging to observe ShCu holistically and to represent them correctly in climate models. To improve ShCu parameterizations, information on both vertically and horizontally resolved cloud properties is required. Commonly, the vertically resolved cloud properties are provided by zenith pointing lidar-radar observations with a very narrow field of view (FOV). Thus, these “pencil-beam” properties may not be representative of a larger surrounding area. Limited number of areal-averaged cloud properties, such as fractional sky cover (FSC), are offered typically by wide-FOV observations. The main goal of our project was to integrate advantages of the narrow-FOV (vertical structure of clouds) and wide-FOV (spatial arrangement of clouds) observations for an improved characterization of single-layer ShCu observed at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site for an 18-yr period (2000-2017). There are four major accomplishments of our project, First, an updated operational cloud classification for days with ShCu has been suggested and evaluated through a detailed comparison with the manually curated records. Our classification extends successfully the latest ARM cloud type Value Added Product (VAP) based on the Active Remote Sensing of Clouds (ARSCL) cloud product by incorporating both cloud fraction (CF) provided by narrow-FOV ceilometer data and FSC from wide-FOV images offered by a Total Sky Imager (TSI). Moreover, our classification allows one to identify impact of instrumentation changes at the SGP site, namely the transition to KAZRARSCL with the updated cloud radar, on the identification of periods with single-layer ShCu. Second, a new approach that resolves cloud area distributions for a given region (up to 4x4 km 2 ) has been suggested and cloud equivalent diameters (CEDs) have been estimated for the first time. These estimations have been performed over a wide range of cloud sizes (about 0.01–3.5 km) with high temporal resolution (30s) using wide-FOV TSI images and cloud base height (CBH) provided by complementary narrow-FOV lidar measurements. Our simple and computationally inexpensive approach offers a previously unavailable dataset for process studies in the convective boundary layer and evaluation of ShCu parameterizations in cloud-resolving models. Third, a long-term integrated record of ShCu macrophysical properties has been developed. The developed record represents the longest available compilation of events with ShCu and includes (i) a novel visualization of the spatial variability in cloud cover both along- and across-wind directions, (ii) updated estimates of narrow-FOV CF and wide-FOV FSC, (iii) updated narrow-FOV CBH, and (iv) complementary data, such as wind speed and direction from the 915-MHz Radar Wind Profiler (RWP) data. The developed record has been used successfully to assess conventional observational estimates of cloud cover and their sensitivity to the following two factors: (i) instrument-dependent cloud detection and data merging criteria and (ii) FOV configuration. Fourth, co-variability of the ShCu macrophysical properties and environmental parameters has been analyzed for a 3-yr period (2016-2018). Our initial analysis includes diurnal changes of FSCs obtained for clouds with small, moderate and large CEDs and several environmental parameters, such as lifted condensation level (LCL) and mixed layer height (zi). Preliminary results of our analysis suggest that the horizontal extent of ShCu is controlled substantially by the sign and magnitude of difference between these two parameters (zi-LCL): the CED tends to grow with increase of this difference (zi exceeds LCL). We have initiated relationships between the ShCu and key atmospheric parameters that control both the development and evolution of ShCu using our new data product, which combines effectively the advantages of narrow-FOV data offered by zenith pointing cloud radars and lidars and wide-FOV TSI images. While the latest instrumentation at the ARM sites may address these challenging relationships in the future, we believe that the historical ARM data at the SGP site has not yet been fully utilized. Overall, our data product can be used by researchers working on a wide range of climate-related projects. These projects may include (i) a comprehensive evaluation of outputs from the Large-Eddy Simulation (LES) and single-column models for their future improvement, (ii) the representativeness of “short-period” results obtained from the previous model and observational studies and (iii) the planning of future field campaigns with focus on improved understanding of the diurnal cycle of cumulus convection.

54 ENVIRONMENTAL SCIENCES↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Formation of Magnetically Truncated Accretion Disks in 3D Radiation-transport Two-temperature GRMHD Simulations

Multiwavelength observations suggest that the accretion disk in the hard and intermediate states of X-ray binaries (XRBs) and active galactic nucleus transitions from a cold, thin disk at large distances into a hot, thick flow close to the black hole (BH). However, the formation, structure, and dynamics of such truncated disks are poorly constrained due to the complexity of the thermodynamic, magnetic, and radiative processes involved. We present the first radiation-transport two-temperature general relativistic magnetohydrodynamic (GRMHD) simulations of truncated disks radiating at ~35% of the Eddington luminosity with and without large-scale poloidal magnetic flux. We demonstrate that when a geometrically thin accretion disk is threaded by large-scale net poloidal magnetic flux, it self-consistently transitions at small radii into a two-phase medium of cold gas clumps floating through a hot, magnetically dominated corona. This transition occurs at a well-defined truncation radius determined by the distance out to which the disk is saturated with magnetic flux. The average ion and electron temperatures in the semiopaque corona reach, respectively, $T_i$ ≳ 10 10 K and $T_e$ ≳ 5 × 10 8 K. The system produces radiation, powerful collimated jets, and broader winds at the total energy efficiency exceeding 90%, the highest ever energy extraction efficiency from a spinning BH by a radiatively efficient flow in a GRMHD simulation. This is consistent with jetted ejections observed during XRB outbursts. The two-phase medium may naturally lead to broadened iron line emission observed in the hard state.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations of Offshore Internal Boundary Layers

The growth of the marine internal boundary layer (MIBL, height h i ) with the shore-normal distance x, is a topic of continuing interest because of its applications in coastal dispersion, offshore wind farm siting, coastal air-sea fluxes and in evaporative ducting. Available data on MIBL are only scarce, given its difficult to measure the variability of coastal winds. During Coupled Air-Sea Processes and Electromagnetic Research (CASPER) campaigns an array of instrumentation was deployed to measure offshore spatial variability and its effect on electromagnetic wave propagation. Meteorological sensors (flux towers and remote sensing) were deployed along the coast of Point Mugu, California, on a research vessel and FLoating Instrument Platform (FLIP) provided surface layer and boundary layer observations. In this article, measurements from multiple remote sensing instruments, such as synchronized triple Doppler lidars, small boat operations with tethered lifting system, and radiosondes provide a holistic view of the MIBL growth and its spatial variability from the coast. A convective and stable MIBL observed during two intensive operating period days showed distinct growth characteristics off the coast of Point-Mugu. During stable stratified atmospheric conditions, an MIBL was observed at least up to 47 km from the coast. The growth of the MIBL within the nearshore adjustment zone was influenced by surrounding atmospheric, oceanographic, and topographic conditions. A new parameterization scheme is developed based on advection-diffusion balance equations accounting for upstream turbulence and compared with h i observations from Doppler lidar and profiles from small boat. An evaluation of existing IBL theories was also conducted.

54 ENVIRONMENTAL SCIENCES↗

Drivers and ecological impacts of a wildfire outbreak in the southern Appalachian Mountains after decades of fire exclusion

During one of the warmest and driest droughts of the last century, the southern Appalachian Mountains experienced a regional outbreak of over a dozen large wildfires in late fall of 2016. We provide a synthesis of long-term forest changes leading up to the 2016 wildfires, examine the climatic setting and patterns of burn severity in relationship to topography, and discuss the ecological and management implications of these and future fires. During the pre- and post-European settlement periods, frequent low- and mixed-severity wildfires interacted with complex topographic gradients and maintained heterogenous landscapes dominated by several species of oak (Quercus spp.), pine (Pinus spp.), and the American chestnut (Castanea dentata). Land-use changes associated with European settlement, loss of the American chestnut, and 20th century fire exclusion resulted in large scale shifts towards mesic, fire-intolerant species (i.e. mesophication). Wildfire activity began increasing in the early 1980s, but most fires in the region are small (<1,000 ha). In Fall of 2016, deciduous tree leaf fall occurred concurrently with a period of anomalously dry and warm weather, creating ideal conditions for fire ignition and spread. Thousands of ignitions across the region strained suppression resources and eight fires grew to greater than 5,000 ha. The 2016 fires were larger and burned more area than in the previous three decades combined. In one unique landscape setting, the Chimney Tops 2 Fire, a synoptic wind event drove extreme fire behavior and burned large, high-severity patches resulting in devastating effects in the wildland urban interface. However, immediate post-fire burn severity mosaics for other fires were composed primarily of low- (73 %) and moderate-severity (21 %) fire effects. High-severity fire comprised only 6 % of the area burned, and occurred mostly on steep upper slopes and ridges on south-facing aspects, reflecting the importance of bottom-up topographic drivers in this region. Although the fires will likely enhance biodiversity by restoring fire-dependent species and creating early seral habitat, invasions of non-native plant species, delayed mortality of mature pines and oaks, and rapid re-sprouting of pyrophyllic shrubs pose significant management challenges. Although similar large fire outbreaks may become more common under future climatic conditions, they are unlikely to reverse the effects of mesophication and significantly alter forest dynamics at broad spatial scales. Furthermore, the 2016 fires exposed the vulnerability of the region to wildfire during acute fall drought and demonstrate the potential ecological effects of future wildfires in mixed pine-hardwood landscapes of the southern Appalachians.

54 ENVIRONMENTAL SCIENCES↗

Simulation of radioactive plume transport in the atmosphere including dynamics of particle aggregation and breakup

Accurate prediction of the atmospheric transport of debris particles relies heavily on our knowledge of the size distribution of the particles within a debris cloud. Assuming a fixed particle size during simulations is not always viable since the size distribution of the debris can change during transport. Various microphysical processes, such as aggregation and breakup, influence debris particles and dictate any changes to the size distribution. To track those changes that can occur, a population balance model can be adopted and instituted within a model framework. Nonetheless, many of the models that simulate the transport of radioactive debris following a device-driven fission incident have historically neglected to consider these processes. As such, this work describes our effort to develop a modeling framework capable of simulating the transport and deposition of a radioactive plume generated from a fission incident with a dynamic population balance including particle aggregation and breakup. Herein the impact of aggregation and breakup, individually and collectively, on the particle size distribution is explored using the developed framework. When simulating aggregation, for example, six mechanisms, including Brownian coagulation, the convective enhancement to Brownian coagulation, van der Waals-viscous force correction for Brownian coagulation, gravitational collection, turbulent inertial motion, and turbulent shear, are considered. Brownian coagulation and its corrections have, as one would expect, a large impact on relatively small aggregates. Aggregates with a diameter that is less than or equal to 1.0 μm, for instance, comprise 50.6 vol % of all aggregates in the absence of aggregation and 31.2 vol % when Brownian coagulation and its corrections are considered. Gravitational collection and, to a much lesser extent, turbulent shear and turbulent inertial motion are, conversely, of great importance to relatively large aggregates (i.e., diameter greater than 3.0 μm). Additionally, the individual effects of atmospheric and particle parameters, such as wind speed and particle density, are examined. Of the parameters examined, turbulent energy dissipation and aggregate fractal dimension (i.e., aggregate shape with lower values representing more irregular particles) were of substantial importance since both terms directly impact aggregate stability and, by extension, the breakup rate. Large-scale transport and deposition simulations in a dry atmosphere are also presented and discussed as a proof of concept.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Serial-Refine Method for Fast Wake-Steering Yaw Optimization

In this paper we present the Serial-Refine method for quickly finding the optimal yaw angles in wake steering. The method optimizes turbine angles serially from upstream to downstream using a small number of candidate angles. The presented results show that Serial-Refine finds solutions that are at least as good as former conventional optimization approaches but that require much less computation time.

17 WIND ENERGY↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

The Helicity Sign of Flux Transfer Event Flux Ropes and Its Relationship to the Guide Field and Hall Physics in Magnetic Reconnection at the Magnetopause

Flux Transfer Events (FTEs) are transient magnetic flux ropes typically found at the Earth's magnetopause on the dayside. While it is known that FTEs are generated by magnetic reconnection, it remains unclear how the details of magnetic reconnection controls their properties. A recent study showed that the helicity sign of FTEs positively correlates with the east-west (B y ) component of the Interplanetary Magnetic Field (IMF). With data from the Cluster and Magnetospheric Multiscale missions, we performed a statistical study of 166 quasi force-free FTEs. We focus on their helicity sign and possible association with upstream solar wind conditions and local magnetic reconnection properties. Using both in situ data and magnetic shear modeling, we find that FTEs whose helicity sign corresponds to the IMF B y are associated with moderate magnetic shears while those that do not correspond to the IMF B y are associated with higher magnetic shears. While uncertainty in IMF propagation to the magnetopause may lead to randomness in the determination of the flux rope core field and helicity, we rather propose that for small IMF B y , which corresponds to high shear and low guide field, the Hall pattern of magnetic reconnection determines the FTE core field and helicity sign. In that context we explain how the temporal sequence of multiple X-line formation and the reconnection rate are important in determining the flux rope helicity sign. This work highlights a fundamental connection between kinetic processes at work in magnetic reconnection and the macroscale structure of FTEs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Widespread windthrow in Southeast Asian tropical forests verified by satellite observations

Windthrow, defined as abrupt tree mortality caused by intense winds, is well documented in the Neotropics but remains largely unverified in Asian tropical forests. Using Landsat 8 imagery for the period 2020-2022 and established spectral (shortwave-infrared, near-infrared, and red band composites) and morphological criteria (fan-shaped geometry and sharp boundaries), this study verified the presence of windthrow across Sumatra, Borneo, and New Guinea and produced the first georeferenced inventory of 60 events in the region. Event sizes were right-skewed, with many small gaps and few large (>200 ha) disturbances. Orientations were anisotropic, with concentrations of windthrow events pointing west to northwest-to-north and eastward, both aligning with known pathways of organized convection in the Maritime Continent of Southeast Asia. Detection was conservatively biased low by cloud cover, long revisit intervals, and the exclusion of land-use areas. This study provides a verified baseline that enables reproducible mapping with higher resolution sensors and field observations to quantify windthrow frequency, severity, and ecological significance.

Asia’s tropical forests↗

Climate-eutrophication-anoxia interactions in Late Glacial Soppensee, Switzerland: Forcings, non-linear responses and recovery

Combined effects of climate warming and anthropogenic nutrient loadings lead to lake eutrophication and anoxia globally. Because of chemical feedbacks, lakes under multiple stressors often respond in non-linear ways. However, it remains unclear whether climate change alone can lead to non-linear lake responses in the absence of anthropogenic nutrient disturbances. Here, we investigate the interactions between climate variability, nutrient cycling and trophic state changes, mixing regimes, anoxia and related chemical feedback in a small kettle-hole lake in Switzerland during Late Glacial times (15.2–12.6 cal ka BP), a period known for high-amplitude climate change in pre-anthropogenic times. After its formation during Heinrich Stadial 1 (>15 cal ka BP), Soppensee was oligotrophic and well-mixed. Soppensee became eutrophic and developed anoxia at 14.25 cal ka BP. Phosphorus (P) was released from sediments through the reductive dissolution of Fe-oxyhydroxides, fuelling eutrophication. Eutrophication lagged the Bølling warming (14.65 cal ka BP) by 400 years, suggesting that rising temperatures were not the trigger for eutrophication. Instead, eutrophication responded non-linearly to forest closure (threshold at 76 % arboreal pollen AP), which shielded Soppensee from wind mixing, enhancing lake stratification, anoxia and P release, intensifying eutrophication. These conditions ended during the 200-years cold period of the Aegelsee Oscillation (GI-1d, ca. 14.0 cal ka BP) when the landscape regionally opened (AP<76 %); the lake became well-mixed, oxygenated and P was efficiently sequestered. Throughout the Allerød (13.9–12.8 cal ka BP), enhanced Fe input prompted diagenetic vivianite formation, sequestering P in sediments, naturally remediating lake eutrophication despite closed forests, warm temperatures, lake stratification and anoxia.

Environmental sciences↗

Design, construction, and testing of no-insulation small subscale solenoids for compact tokamaks

Fusion energy systems studies (FESS) for next-step devices based on the most promising magnetic configurations indicate that high magnetic fields and high current density for magnet coil systems may reduce device size and lower the cost. High current density and radiation resistant fusion magnets are particularly beneficial for low cost, low aspect ratio compact reactor designs such as Fusion Nuclear Science Facility (FNSF), Fusion Pilot Plant (FPP) of low-aspect ratio spherical tokamak (ST) or compact stellarators. Unlike typical high field magnets for nuclear magnetic resonance (NMR), magnetic resonance imaging (MRI), or high energy physics research applications, neutron irradiation damage to organic insulations in the coil winding pack is a critical issue for next generation fusion reactors where orders of magnitude higher neutron fluence than those in present experimental reactors such as ITER are expected. Moreover, a high coil winding pack current density is needed for high field magnets in low cost, compact radial build next step fusion reactors. The slow current charging time, however, is an issue in fully non-insulated coils. In this work, we present the design, construction and testing of subscale Nb3Sn solenoids, up to half the diameter of the central solenoid (CS) for National Spherical Torus Experiment (NSTX), with and without inter-layer insulation for enhancing radiation resistance while improving the winding pack current density and coil performance. The major radius for the NSTX/NSTX-Upgrade (reference for compact ST) is 0.854/0.934 meter, and 4.8 meters for FNSF. The magnetic field for NSTX/NSTX-U at the plasma center is 0.6/1 Tesla and 9 Tesla for FNSF. The inner diameter of the central solenoid coil is 0.2/0.4 meter for NSTX/NSTX-U and 1.2 meters for FNSF. The current charging and discharging behavior of the prototype solenoids was investigated to quantify performance advantages of a simplified coil fabrication without error-prone vacuum pressure impregnation (VPI) for the removal of epoxy organic insulation. Scalability of the no insulation concept for fusion can be addressed via engineered coating for novel insulation on contact resistance or intra-layer no insulations. Radiation resistance and coil winding efficiency were significantly improved in the no insulation coils for next step compact fusion reactors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗