Quality Assurance of Ultrasound Imaging Systems for Target Localization and Online Setup Corrections

We describe quality assurance paradigms for ultrasound imaging systems for target localization (UISTL). To determine the absolute localization accuracy of a UISTL, an absolute coordinate system can be established in the treatment room and spherical targets at various depths can be localized. To test the ability of such a system to determine the magnitude of internal organ motion, a phantom that mimics the human male pelvic anatomy can be used to simulate different organ motion ranges. To assess the interuser variability of ultrasound (US) guidance, different experienced users can independently determine the daily organ shifts for the same patients for a number of consecutive fractions. The average accuracy for a UISTL for the localization of spherical targets at various depths has been found to be 0.57 {+-} 0.47 mm in each spatial dimension for various focal depths. For the phantom organ motion test it was found that the true organ motion could be determined to within 1.0 mm along each axis. The variability between different experienced users who localized the same 5 patients for five consecutive fractions was small in comparison to the indicated shifts. In addition to the quality assurance tests that address the ability of a UISTL to accurately localize a target, a thorough quality assurance program should also incorporate the following two aspects to ensure consistent and accurate localization in daily clinical use: (1) adequate training and performance monitoring of users of the US target localization system, and (2) prescreening of patients who may not be good candidates for US localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance for Kilo- and Megavoltage In-Room Imaging and Localization for Off- and Online Setup Error Correction

In-room radiography is not a new concept for image-guided radiation therapy. Rapid advances in technology, however, have made this positioning method convenient, and thus radiograph-based positioning has propagated widely. The paradigms for quality assurance of radiograph-based positioning include imager performance, systems integration, infrastructure, procedure documentation and testing, and support for positioning strategy implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Margin Evaluation in the Presence of Deformation, Rotation, and Translation in Prostate and Entire Seminal Vesicle Irradiation With Daily Marker-Based Setup Corrections

Purpose: To develop a method for margin evaluation accounting for all measured displacements during treatment of prostate cancer. Methods and Materials: For 21 patients treated with stereographic targeting marker-based online translation corrections, dose distributions with varying margins and gradients were created. Sets of possible cumulative delivered dose distributions were simulated by moving voxels and accumulating dose per voxel. Voxel motion was simulated consistent with measured distributions of systematic and random displacements due to stereographic targeting inaccuracies, deformation, rotation, and intrafraction motion. The method of simulation maintained measured correlation of voxel motions due to organ deformation. Results: For the clinical target volume including prostate and seminal vesicles (SV), the probability that some part receives <95% of the prescribed dose, the changes in minimum dose, and volume receiving 95% of prescription dose compared with planning were 80.5% {+-} 19.2%, 9.0 {+-} 6.8 Gy, and 3.0% {+-} 3.7%, respectively, for the smallest studied margins (3 mm prostate, 5 mm SV) and steepest dose gradients. Corresponding values for largest margins (5 mm prostate, 8 mm SV) with a clinical intensity-modulated radiotherapy dose distribution were 46.5% {+-} 34.7%, 6.7 {+-} 5.8 Gy, and 1.6% {+-} 2.3%. For prostate-only clinical target volume, the values were 51.8% {+-} 17.7%, 3.3 {+-} 1.6 Gy, and 0.6% {+-} 0.5% with the smallest margins and 5.2% {+-} 7.4%, 1.8 {+-} 0.9 Gy, and 0.1% {+-} 0.1% for the largest margins. Addition of three-dimensional rotation corrections only improved these values slightly. All rectal planning constraints were met in the actual reconstructed doses for all studied margins. Conclusion: We developed a system for margin validation in the presence of deformations. In our population, a 5-mm margin provided sufficient dosimetric coverage for the prostate. In contrast, an 8-mm SV margin was still insufficient owing to deformations. Addition of three-dimensional rotation corrections was of minor influence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual Setup Errors Towards the Heart After Image Guidance Linked With Poorer Survival in Lung Cancer Patients: Do We Need Stricter IGRT Protocols?

Image guided radiation therapy (IGRT) is widely used, but data directly relating set-up errors to patient outcome are scarce. This study investigates the relationship between residual IGRT shifts and overall patient survival and uses the observed relations to identify structures sensitive to radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionation of critical metals from authentic acid mine drainage using a multi-bed immobilized amine sorbent setup: A field site study

Here for the first time reported, a flow-through multi-fixed bed immobilized amine/silica sorbent strategy was employed to fractionate purified critical metals from authentic acid mine drainage (AMD). The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory’s (NETL) patent-pending Multi-functional Sorbent Technology (MUST) sorbents were used to recover critical metals from AMD at the Pittsburgh Botanic Garden (Pittsburgh, PA USA). By adjusting the AMD/sorbent ratio, we recovered > 80% of pure adsorbed Mn (by adsorbed metal weight) and >90% pure adsorbed Al at lab-scale. Further optimizing the weight hourly space velocity (WHSV) enhanced the rate of adsorbed Al recovery by over five times, justifying a field site test. After treating >100 L of AMD at the field site, the optimized polyamine/epoxysilane/aminosilane sorbent recovered approximately 0.7 wt% adsorbed Al at > 90% purity. A tangible amount of purified aluminum hydroxide [Al(OH) 3 ] and aluminum sulfate [Al 2 (SO 4 ) 3 ] solids were then recovered after eluting and precipitating the previously adsorbed metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supine Craniospinal Irradiation Setup with Two Spine Fields

Craniospinal irradiation is an integral part of treatment for a number of cancers. Typically, patients are positioned prone, which allows visualization of field matches. However, a supine position allows better airway access for patients requiring anesthesia, and is more comfortable for patients. One potential difficulty with supine positioning occurs when the patient is tall and requires matching 2 spine fields. We describe a technique to match the spine fields using light fields on the bottom of the treatment table, and verified the approach on a phantom. The accuracy of the technique is demonstrated for the first 4 patients, with the majority of field gaps and overlaps below our clinical tolerance of 2 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of Fission Neutron Spectrum and Multiplicity using a Gamma Tag Double Time-of-flight Setup

Recent efforts have been made to improve the prompt fission neutron spectrum and nu-bar measurements for Uranium and Plutonium isotopes particularly in the keV region. A system has been designed at Rensselaer Polytechnic Institute (RPI) utilizing an array of EJ-301 liquid scintillators as well as lithium glass and plastic scintillators to experimentally determine these values. An array of BaF2 detectors was recently obtained from Oak Ridge National Laboratory to be used in conjunction with the neutron detectors. The system uses a novel gamma tagging method for fission which can offer an improvement over conventional fission chambers due to increased sample mass. A coincidence requirement on the gamma detectors from prompt fission gammas is used as the fission tag for the system as opposed to fission fragments in a conventional fission chamber. The system utilizes pulse digitization using Acqiris 8 bit digitizer boards which allow for gamma/neutron pulse height discrimination on the liquid scintillators during post processing. Additionally, a 252Cf fission chamber was designed and constructed at RPI which allowed for optimization and testing of the system without the need for an external neutron source. The characteristics of the gamma tagging method such as false detection rate and detection efficiency were determined using this fission chamber and verified using MCNP Polimi modeling. Prompt fission neutron spectrum data has been taken using the fission chamber focusing on the minimum detectable neutron energy for each of the various detectors. Plastic scintillators were found to offer a significant improvement over traditional liquid scintillators allowing energy measurements down to 50 keV. Background was also characterized for all detectors and will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of 65 Zn electron-capture decays with the KDK coincidence setup

65 Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, γ-spectroscopy is a preferred method of 65 Zn standardization, which relies directly on the branching ratio of Jπ( 65 Zn) = 5/2- → Jπ( 65 Cu) = 5/2 - via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC 0 ) using a novel coincidence technique, finding I EC 0/IEC* = 0.9684 ± 0.0018. Re-evaluating the decay scheme of 65 Zn by adopting the commonly evaluated branching ratio of I β+ = 1.4271(7)% we obtain IEC* = (50.08 ± 0.06)%, and I EC 0 = (48.50 ± 0.06)%. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of 65 Zn, and is applicable to other isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Most theoretical approaches used in nuclear astrophysics to model the nucleosynthesis of heavy elements incorporate the so-called statistical model in order to describe the excitation and decay properties of atomic nuclei. One of the basic assumptions of this model is the validity of the Brink–Axel hypothesis and the related concept of so-called photon strength functions to describe γ-ray transition probabilities. We present a novel experimental approach that allows for the first time to experimentally determine the photon strength function simultaneously in two independent ways by a unique combination of quasi-monochromatic photon beams and a newly implemented γ–γ coincidence setup. This technique does not assume a priori the validity of the Brink–Axel hypothesis and sets a benchmark in terms of the detection sensitivity for measuring decay properties of photo-excited states below the neutron separation energy. The data for the spherical off-shell nucleus 128 Te were obtained for γ-ray beam-energy settings between 3 MeV and 9 MeV in steps of 130 keV for the lower beam energies and in steps of up to 280 keV for the highest beam settings. We present a quantitative analysis on the consistency of the derived photon strength function with the Brink–Axel hypothesis. The data clearly demonstrate a discrepancy of up to a factor of two between the photon strength functions extracted from the photoabsorption and photon emission process, respectively. In addition, we observe that the photon strength functions are not independent of the excitation energy, as usually assumed. Thus, we conclude, that the Brink–Axel hypothesis is not strictly fulfilled in the excitation-energy region below the neutron separation threshold (S n = 8.78 MeV) for the studied case of 128 Te.

Not Available

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards a Unified Setup to Simulate Mid‐Latitude and Tropical Mesoscale Convective Systems at Kilometer‐Scales

Abstract Mesoscale convective systems (MCSs) are the main source of precipitation in the tropics and parts of the mid‐latitudes and are responsible for high‐impact weather worldwide. Studies showed that deficiencies in simulating mid‐latitude MCSs in state‐of‐the‐art climate models can be alleviated by kilometer‐scale models. However, whether these models can also improve tropical MCSs and whether we can find model settings that perform well in both regions is understudied. We take advantage of high‐quality MCS observations collected over the Atmospheric Radiation Measurement (ARM) facilities in the US Southern Great Plains (SGP) and the Amazon basin near Manaus (MAO) to evaluate a perturbed physics ensemble of simulated MCSs with 4 km horizontal grid spacing. A new model evaluation method is developed that enables to distinguish biases stemming from spatiotemporal displacements of MCSs from biases in their reflectivity and cloud shield. Amazon MCSs are similarly well simulated across these evaluation metrics than SGP MCSs despite the challenges anticipated from weaker large‐scale forcing in the tropics. Generally, SGP MCSs are more sensitive to the choice of model microphysics, while Amazon cases are more sensitive to the planetary boundary layer (PBL) scheme. Although our tested model physics combinations had strengths and weaknesses, combinations that performed well for SGP simulations result in worse results in the Amazon basin and vice versa. However, we identified model settings that perform well at both locations, which include the Thompson and Morrison microphysics coupled with the Yonsei University (YSU) PBL scheme and the Thompson scheme coupled with the Mellor‐Yamada‐Janjic PBL scheme.

54 ENVIRONMENTAL SCIENCES↗

Incorporating spectroscopic on-line monitoring as a method of detection for a Lewis cell setup

A Lewis cell was designed and constructed for investigating solvent extraction systems by spectrophotometrically monitoring both the organic and aqueous phases in real time. This new Lewis cell was tested and shown to perform well compared to other previously reported Lewis cell designs. The advantage of the new design is that the spectroscopic measurement allows determination of not only metal ion concentrations, but also information regarding chemical speciation—information not available with previous Lewis cell designs. For convenience, the new Lewis cell design was dubbed COSMOFLEX (COntinuous Spectroscopic MOnitoring of Forrest’s Liquid-liquid EXtraction cell).

ARMOLLEX↗

New prompt fission neutron spectra measurements in the 238 U(n,f) reaction with a dedicated setup at LANSCE/WNR

A new prompt fission neutron spectra (PFNS) measurement in the 238 U(n,f) reaction was performed at LANSCE/WNR facility. Evaluated data show discrepancies on the low (below 1 MeV) and high (above 5 MeV) energy parts in the PFNS for different major and minor actinides. The goal is to improve these measurements in a wide range of incident energy. The energy of the incoming neutron, inducing the fission, and the prompt neutron energies, are measured by time-of-flight method. A dedicated fission chamber was developed, in order to improve alpha-fission discrimination, timing resolution, actinide mass, and to reduce the amount of neutron scattering. To detect prompt neutrons, the 54 Chi-Nu scintillator cells array were surrounding the fission chamber. High statistics were recorded during this experiment, allowing a precise study of PFNS behavior as a function of incident neutron energy, from 1 MeV to 200 MeV. In conclusion, this experiment also showed that all the new tools developed to improve PFNS measurements are performing. Therefore, measurements of PFNS with others actinides such as 239 Pu are planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 1+/N+ setup for the production of multicharged radioactive alkali ions in SPIRAL

In the framework of the production of radioactive ion beams by the isotope separator online method, a new system has been developed at GANIL/SPIRAL I to produce multicharged alkali ions. The principle, referred to as the ''direct 1+/N+ method,'' consists of a surface ionization source associated with a multicharged electron-cyclotron-resonance ion source without an intermediate mass separator. This new system has been tested online using a {sup 48}Ca primary beam at 60.3 A MeV. The experimental evidence of the direct 1+/N+ process has been obtained for a potential difference between the two sources of 11 V and with a 1+/N+ charge breeding efficiency of 0.04% for {sup 47}K{sup 5+}. This value is significantly lower than the value of 6% obtained for stable K ions with the standard 1+/N+ method. A possible explanation is given in the text.

07 ISOTOPE AND RADIATION SOURCES↗

Lifetime measurements using the CLARA-PRISMA setup around the {sup 48}Ca doubly-magic nucleus

The lifetimes of the first excited states of nuclei around the doubly-magic nucleus {sup 48}Ca have been determined using a novel method that combines the Recoil Distance Doppler Shift (RDDS) method with the CLARA-PRISMA spectrometers. This is the first time such a method is applied to measure lifetimes of neutron-rich nuclei populated via a multinucleon transfer reaction. This novel method and some preliminary results on lifetimes are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗