SEARCH · Engineering Papers
Results for “sample”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility
Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500–2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ~20 μm thickness have been performed. X-ray yields of up to ~1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ~100 μm FWHM, with ~350 ps pulse duration during the peak emission stage. Lastly, these results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.
Contour forward flux sampling: Sampling rare events along multiple collective variables
Many rare event transitions involve multiple collective variables (CVs), and the most appropriate combination of CVs is generally unknown a priori. As such, we introduce a new method, contour forward flux sampling (cFFS), to study rare events with multiple CVs simultaneously. cFFS places nonlinear interfaces on-the-fly from the collective progress of the simulations, without any prior knowledge of the energy landscape or appropriate combination of CVs. We demonstrate cFFS on analytical potential energy surfaces and a conformational change in alanine dipeptide.
Quasiclassical sampling and Wigner sampling of initial vibrational coordinates and momenta for polyatomic molecules in Monte Carlo molecular dynamics simulations
In a quasiclassical trajectory simulation, the vibrational modes are initialised with quantised vibrational energies, but vibrational phases are sampled by Monte Carlo. This requires an algorithm to assign coordinates and momenta to the various atoms. In this work, we present two methods for implementing this for nonrotating polyatomic molecules, namely, fixed-energy vibrational-state-selected initial conditions and thermal initial conditions. We also present a method for initiating classical trajectories with a ground-state Wigner distribution. These vibrational treatments are sufficient to initialise trajectories for unimolecular processes, and we also show how they can be applied to simulate bimolecular collision processes. The treatments of unimolecular and bimolecular collision processes are available in two Python codes called wigner_state_selected.py and bimolecular_collision.py, respectively, which will generate initial condition files that are recognisable by the SHARC and SHARC-MN computer programs for dynamics calculations. Both codes are available as standalone programs, as well as being included in SHARC-MN, and they will be included in future versions of SHARC. Here, the methods implemented in these codes are mostly also available in the ANT computer program, and those that are not available in ANT will be incorporated in future versions of ANT.
Analysis of surface and seismic sources in dense array data with match field processing and Markov chain Monte Carlo sampling
Not provided.
Basis Function Sampling: A New Paradigm for Material Property Computation
Not Available
Genome Sequences of Industrially Relevant Saccharomyces cerevisiae Strain M3707, Isolated from a Sample of Distillers Yeast and Four Haploid Derivatives
Saccharomyces cerevisiae strain M3707 was isolated from a sample of commercial distillers yeast, and its genome sequence together with the genome sequences for the four derived haploid strains M3836, M3837, M3838, and M3839 has been determined. Yeasts have potential for consolidated bioprocessing (CBP) for biofuel production, and access to these genome sequences will facilitate their development.
‘N-of-1- pathways ’ unveils personal deregulated mechanisms from a single pair of RNA-Seq samples: towards precision medicine
Explore the source record for details and available documents.
Compressive Sensing with Cross-Validation and Stop-Sampling for Sparse Polynomial Chaos Expansions
Here, compressive sensing is a powerful technique for recovering sparse solutions of underdetermined linear systems, which is often encountered in uncertainty quantification analysis of expensive and high-dimensional physical models. We perform numerical investigations employing several compressive sensing solvers that target the unconstrained LASSO formulation, with a focus on linear systems that arise in the construction of polynomial chaos expansions. With core solvers l1_ls, SpaRSA, CGIST, FPC_AS, and ADMM, we develop techniques to mitigate overfitting through an automated selection of regularization constant based on cross-validation, and a heuristic strategy to guide the stop-sampling decision. Practical recommendations on parameter settings for these techniques are provided and discussed. The overall method is applied to a series of numerical examples of increasing complexity, including large eddy simulations of supersonic turbulent jet-in-crossflow involving a 24-dimensional input. Through empirical phase-transition diagrams and convergence plots, we illustrate sparse recovery performance under structures induced by polynomial chaos, accuracy, and computational trade-offs between polynomial bases of different degrees, and practicability of conducting compressive sensing for a realistic, high-dimensional physical application. Across test cases studied in this paper, we find ADMM to have demonstrated empirical advantages through consistent lower errors and faster computational times.
Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification MST Solids Sample
Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Interim Salt Disposition Program (ISDP) Batch 7 processing. The Marcrobatch 7 material was received with visible fine particulate solids, atypical for these samples. The as received material was allowed to settle for a period greater than 24 hours. The supernatant was then decanted and utilized as our clarified feed material. As part of this qualification work, SRNL performed an Actinide Removal Process (ARP) test using the clarified feed material. From this test, the residual monosodium titanate (MST) was analyzed for radionuclide uptake after filtration from H-Tank Farm (HTF) feed salt solution. The results of these analyses are reported and are within historical precedent.
Sample Results from Routine Samples After the NGS Changeover
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 6D and 7B have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES).
Sample results from the interim salt disposition program macrobatch 8 tank 21H qualification MST solids sample
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for Interim Salt Disposition Program (ISDP) processing. As part of this qualification work, SRNL performed an Actinide Removal Process (ARP) and several Extraction, Scrub, Strip (ESS) tests. This document reports characterization of the monosodium titanate (MST) solids from the ARP test. The results of these analyses are reported and are within historical precedent.
Sampling Report for August 15, 2014 WIPP Samples
This report outlines the attempted sampling of drum 68660—the breached drum identified in Panel 7 of the WIPP. When Drum 68660 breached, the incident left a gap in the lip of the drum and it is assumed that its contents spewed in the vicinity of the drum and throughout Panel 7. Several rows of waste were affected, based on the disappearance of the MgO over packing of several rows.
LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample
Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.
Sample quadratic variation of sample continuous second order martingales.
Sample continuous second order martingale process, determining existence of limit of stochastic processes using approximation theorems
Micropaleontological studies of lunar samples. A search for biogenic structures in the Apollo 12 lunar samples
Biogeochemical and microstructural analyses on lunar rock and dust samples for biological compounds
Lunar sample analysis program. High sensitivity isotopic analysis - Apollo 11 and 12. Isotopic abundances of actinide elements in Apollo 12 samples Final technical report
Abundance of uranium, thorium, and plutonium isotopes in Apollo 12 soil and breccia samples
Luminescence of Apollo 11 and 12 lunar samples. Lunar sample analysis program
Luminescence measurements on Apollo 11 and Apollo 12 lunar soil samples