Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗

Uncertainty Analysis in 3D Equilibrium Reconstruction

Reconstruction is an inverse process where a parameter space is searched to locate a set of parameters with the highest probability of describing experimental observations. Due to systematic errors and uncertainty in experimental measurements, this optimal set of parameters will contain some associated uncertainty. This uncertainty in the optimal parameters leads to uncertainty in models derived using those parameters. V3FIT is a three-dimensional (3D) equilibrium reconstruction code that propagates uncertainty from the input signals, to the reconstructed parameters, and to the final model. Here in this paper, we describe the methods used to propagate uncertainty in V3FIT. Using the results of whole shot 3D equilibrium reconstruction of the Compact Toroidal Hybrid, this propagated uncertainty is validated against the random variation in the resulting parameters. Two different model parameterizations demonstrate how the uncertainty propagation can indicate the quality of a reconstruction. As a proxy for random sampling, the whole shot reconstruction results in a time interval that will be used to validate the propagated uncertainty from a single time slice.

97 MATHEMATICS AND COMPUTING↗

Systematic analysis of magnetic equilibrium reconstruction with eddy currents on LTX- β

Magnetic equilibrium reconstruction in the Lithium Tokamak Experiment-Beta (LTX-β) is complicated by strong eddy currents and toroidal asymmetries arising from its segmented, close-fitting conducting shell. In the earlier experiment LTX, these three-dimensional (3D) conductor effects significantly distorted diagnostic signals and challenged conventional axisymmetric reconstruction methods. In this work, we demonstrate that accurate plasma equilibria can be recovered on LTX-β by incorporating a small number of dominant eddy current modes derived from realistic conductor models. Using the open-source $\tt{TokaMaker}$ Grad–Shafranov solver, we reconstruct equilibria across a systematically selected set of LTX-β discharges and validate them against the legacy $\tt{PSI-Tri}$ hybrid 2D-3D code. Our results show that fully 2D $\tt{TokaMaker}$ reconstructions achieve significantly improved agreement with flux loop and Mirnov probe measurements, reducing total chi-squared fitting errors, especially during startup. Finally, we develop new hybrid 2D-3D $\tt{TokaMaker}$ reconstructions by integrating the $\tt{ThinCurr}$ 3D eddy current model, which we optimize for significant further reduction of chi-squared in most scenarios. These findings underscore the importance of realistic wall-current modeling in short-pulse tokamaks, and establish a physics-based reconstruction framework that is extensible to devices with complex passive structures and 3D wall interactions.

Grad–Shafranov solver↗

TomocuPy – efficient GPU-based tomographic reconstruction with asynchronous data processing

Fast 3D data analysis and steering of a tomographic experiment by changing environmental conditions or acquisition parameters require fast, close to real-time, 3D reconstruction of large data volumes. Here a performance-optimized TomocuPy package is presented as a GPU alternative to the commonly used central processing unit (CPU) based TomoPy package for tomographic reconstruction. TomocuPy utilizes modern hardware capabilities to organize a 3D asynchronous reconstruction involving parallel read/write operations with storage drives, CPU–GPU data transfers, and GPU computations. In the asynchronous reconstruction, all the operations are timely overlapped to almost fully hide all data management time. Since most cameras work with less than 16-bit digital output, the memory usage and processing speed are furthermore optimized by using 16-bit floating-point arithmetic. As a result, 3D reconstruction with TomocuPy became 20–30 times faster than its multi-threaded CPU equivalent. Full reconstruction (including read/write operations and methods initialization) of a 2048 3 tomographic volume takes less than 7 s on a single Nvidia Tesla A100 and PCIe 4.0 NVMe SSD, and scales almost linearly increasing the data size. To simplify operation at synchrotron beamlines, TomocuPy provides an easy-to-use command-line interface. Efficacy of the package was demonstrated during a tomographic experiment on gas-hydrate formation in porous samples, where a steering option was implemented as a lens-changing mechanism for zooming to regions of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

tomoCAM : fast model-based iterative reconstruction via GPU acceleration and non-uniform fast Fourier transforms

X-ray-based computed tomography is a well established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the brightness and detector technology of tomography instruments at synchrotron sources. These advancements have led to the emergence of new observations and discoveries, with improved capabilities such as faster frame rates, larger fields of view, higher resolution and higher dimensionality. These advancements have enabled the material science community to expand the scope of tomographic measurements towards increasingly in situ and in operando measurements. In these new experiments, samples can be rapidly evolving, have complex geometries and restrictions on the field of view, limiting the number of projections that can be collected. In such cases, standard filtered back-projection often results in poor quality reconstructions. Iterative reconstruction algorithms, such as model-based iterative reconstructions (MBIR), have demonstrated considerable success in producing high-quality reconstructions under such restrictions, but typically require high-performance computing resources with hundreds of compute nodes to solve the problem in a reasonable time. Here, tomoCAM , is introduced, a new GPU-accelerated implementation of model-based iterative reconstruction that leverages non-uniform fast Fourier transforms to efficiently compute Radon and back-projection operators and asynchronous memory transfers to maximize the throughput to the GPU memory. The resulting code is significantly faster than traditional MBIR codes and delivers the reconstructive improvement offered by MBIR with affordable computing time and resources. tomoCAM has a Python front-end, allowing access from Jupyter -based frameworks, providing straightforward integration into existing workflows at synchrotron facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DEEP NEURAL NETWORKS FOR NON-LINEAR MODEL-BASED ULTRASOUND RECONSTRUCTION

Ultrasound reflection tomography is widely used to image large complex specimens that are only accessible from a single side, such as well systems and nuclear power plant containment walls. Typical methods for inverting the measurement rely on delay-and-sum algorithms that rapidly produce reconstructions but with significant artifacts. Recently, model-based reconstruction approaches using a linear forward model have been shown to significantly improve image quality compared to the conventional approach. Nonetheless, even these techniques result in artifacts for complex objects because of the inherent non-linearity of the ultrasound forward model.In this paper, we propose a non-iterative model-based reconstruction method for inverting measurements that are based on non-linear forward models for ultrasound imaging. Our approach involves obtaining an approximate estimate of the reconstruction using a simple linear back-projection and training a deep neural network to refine this to the actual reconstruction. As a result, we apply our method to simulated and experimental ultrasound data to demonstrate dramatic improvements in image quality compared to the delay-and-sum approach and the linear model-based reconstruction approach.

97 MATHEMATICS AND COMPUTING↗

Model-Based Iterative Reconstruction of Magnetization Using Vector Field Electron Tomography

Vector field electron tomography (VFET) is extensively used for three-dimensional (3-D) imaging of magnetic materials at nanometer resolutions. The conventional approach is to reconstruct and visualize the magnetic vector potential or the magnetic field associated with the sample. There is a lack of algorithms capable of reconstructing the 3-D distribution of magnetization from VFET data. Unlike magnetic vector potential and magnetic field, magnetization is a fundamental physical property of the sample that does not extend beyond the dimensions of the sample. We present a model-based iterative reconstruction algorithm (MBIR) that reconstructs the magnetization by minimizing a cost function consisting of a forward model term and a prior model term. The forward model uses the physics of imaging to model the VFET data as a function of the magnetization, and the prior model enforces sparsity in the magnetization reconstruction. We then formulate an optimization algorithm based on the theory of alternate direction method of multipliers to minimize the resulting MBIR cost function. In conclusion, using simulated and real data, we show that our algorithm accurately reconstructs both the magnetization and the magnetic vector potential.

97 MATHEMATICS AND COMPUTING↗

Sempervirens: A Fast Reconstruction Algorithm for Noisy and Incomplete Binary Matrix Representations of Trees

Applications such as reconstructing cell lineage trees (represented as phylogenetic trees) from single-cell sequencing data require reconstructing a {0,1}-matrix that has many errors and missing entries. We introduce Sempervirens, a very fast matrix reconstruction algorithm for noisy and incomplete matrix representations of phylogenetic trees. Sempervirens uses an iterative maximum-likelihood approach to determine the topology tree represented by the corrupted data. We show that Sempervirens is at least three orders of magnitude faster than other methods on thousand by thousand matrices, with the speed gap widening with larger matrices. We also show that Sempervirens matches state-of-the-art methods in reconstruction accuracy. The speed of Sempervirens enables it to be tractably applied to reconstructing much larger matrices than those that other methods can reconstruct. In addition to experimental results, we justify the algorithm with a mathematical treatment of its subprocedures.

algorithms↗

Remote sensing images, DEM, and point clouds associated with “Accuracy evaluation of cost-effective 3D reconstruction approaches for hydrobiogeochemical processes in non-perennial stream riverbeds”

This data package is associated with the publication “Accuracy evaluation of cost-effective 3D reconstruction approaches for hydrobiogeochemical processes in non-perennial stream riverbeds” published in Frontiers in Environmental Science, Environmental Informatics and Remote Sensing (Bao et al., 2026; doi: 10.3389/fenvs.2026.1725258). This data package includes the drone photos for a section of Umtanum Creek in Washington, Unted States. The photos were used to reconstruct the 3-dimensional (3D) digital elevation model (DEM) of the riverbed for the investigated stream section. The reconstruction results from four approaches are provided: (1) unoccupied aerial vehicle (UAV, colloquially known as drone) imagery-based Structure-from-Motion (SfM), (2) a machine learning-based 3D reconstruction model, Visual Geometry Grounded Deep Structure from Motion (VGGSfM), (3) Visual Geometry Grounded Transformer for long sequence of images (VGGT-Long), and (4) handheld smartphone LiDAR scanning. The ground truth measurements by tripod-mounted optical level kit and ground control points GPS locations for evaluating the accuracy of the four reconstruction approaches are also provided in this data package. A preliminary version of this data package was published in October 2025 at the time of manuscript submission. It was updated in March 2026, at the time of manuscript acceptance, to include additional metadata (this readme, data dictionary, and file level metadata). The data did not change. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) 8 folders; (2) the detailed flight configuration html files; (3) field metadata; (4) a readme; (5) a data dictionary; and (6) file-level metadata. The folders “2024_10_18_d01” and “2024_10_18_d02” contain the original drone photos for the two drone flights (d01 and d02) on October 18, 2024. The reconstruction results from each of the approaches are in the folders called “ODM_SfM”, “VGGSfM”, “VGGTLong”, and “LiDAR”. The ground truth measurements are in the folder called “optical_level_kit”. Lastly, results comparing the different approaches are in the folder called “comparisons”. All files are .csv, .html, .jpg, .obj, .txt, and .npy. For information on using the .obj and .npy files, see the readme files within the same folder as the files.

54 ENVIRONMENTAL SCIENCES↗

Non-Diffusive Volume Advection with A High Order Interface Reconstruction Method

We show that non-diffusive volume advection in two-dimensions is achieved with several benchmark problems using a newly developed high-order volume of fluids (VOF) interface reconstruction method. (1) A new VOF interface reconstruction method using circular/corner facets (linear facets are a degenerate case of arcs). We create a circular interface facet in each mixed zone by matching neighbor volume with a hybrid Newton’s-bisection method and the local solution is final. In the general case, the new VOF interface reconstruction has 3rd order accuracy and can be easily made seamless. The new method addresses intrinsic issues with Young’s method such as gaps between interface facets in the case of a curved interface, and inability to define curvature nor identify corners. (2) A non-diffusive volume advection scheme. In an ALE advection step, a well-defined interface can be carried over through a Lagrange step and used to compute volume distribution into a relaxed mesh. Then, an interface reconstruction step is performed to redefine the interface in the relaxed mesh. We must point out that the interface carried over is also a solution of interface reconstruction because all the volume fractions in the relaxed mesh are naturally matched. We provide an interface tracking method compatible with our reconstruction scheme, where it is granted to use the prior info as an initial guess to capture sub-mesh resolution features. As a result, we are able to treat multiple facets inside a single mixed cell and obtain highly accurate, non-diffusive solution for advection problems with rather coarse meshes. We show our solutions for two-dimensional incompressible flows with two materials with a) the X + O diagonal translation; b) the Zalesak rotational test; and c) the single vortex spiral test.

97 MATHEMATICS AND COMPUTING↗

On the Reconstruction of Palaeo-Ice Sheets: Recent Advances and Future Challenges

Reconstructing the growth and decay of palaeo-ice sheets is critical to understanding mechanisms of global climate change and associated sea-level fluctuations in the past, present and future. The significance of palaeo-ice sheets is further underlined by the broad range of disciplines concerned with reconstructing their behaviour, many of which have undergone a rapid expansion since the 1980s. In particular, there has been a major increase in the size and qualitative diversity of empirical data used to reconstruct and date ice sheets, and major improvements in our ability to simulate their dynamics in numerical ice sheet models. These developments have made it increasingly necessary to forge interdisciplinary links between sub-disciplines and to link numerical modelling with observations and dating of proxy records. The aim of this paper is to evaluate recent developments in the methods used to reconstruct ice sheets and outline some key challenges that remain, with an emphasis on how future work might integrate terrestrial and marine evidence together with numerical modelling. Our focus is on pan-ice sheet reconstructions of the last deglaciation, but regional case studies are used to illustrate methodological achievements, challenges and opportunities. Whilst various disciplines have made important progress in our understanding of ice-sheet dynamics, it is clear that data-model integration remains under-used, and that uncertainties remain poorly quantified in both empirically-based and numerical ice-sheet reconstructions. The representation of past climate will continue to be the largest source of uncertainty for numerical modelling. As such, palaeo-observations are critical to constrain and validate modelling. State-of-the-art numerical models will continue to improve both in model resolution and in the breadth of inclusion of relevant processes, thereby enabling more accurate and more direct comparison with the increasing range of palaeo-observations. Thus, the capability is developing to use all relevant palaeo-records to more strongly constrain deglacial (and to a lesser extent pre-LGM) ice sheet evolution. In working towards that goal, the accurate representation of uncertainties is required for both constraint data and model outputs. Close cooperation between modelling and data-gathering communities is essential to ensure this capability is realised and continues to progress.

Ice sheet reconstruction↗

Retrospective IMRT Dose Reconstruction Based on Cone-Beam CT and MLC Log-File

Purpose: Head-and-neck (HN) cone-beam computed tomography (CBCT) can be exploited to probe the IMRT dose delivered to a patient taking into account the interfraction anatomic variation and any potential inaccuracy in the IMRT delivery. The aim of this work is to reconstruct the intensity-modulated radiation therapy dose delivered to an HN patient using the CBCT and multileaf collimator (MLC) log-files. Methods and Materials: A cylindrical CT phantom was used for calibrating the electron density and validating the procedures of the dose reconstruction. Five HN patients were chosen, and for each patient, CBCTs were performed on three separate fractions spaced every 2 weeks starting from the first fraction. The respective MLC log-files were retrieved and converted into fluence maps. The dose was then reconstructed on the corresponding CBCT with the regenerated fluence maps. The reconstructed dose distribution, dosimetric endpoints, and DVHs were compared with that of the treatment plan. Results: Phantom study showed that HN CBCT can be directly used for dose reconstruction. For most treatment sessions, the CBCT-based dose reconstructions yielded DVHs of the targets close (within 3%) to that of the original treatment plans. However, dosimetric changes (within 10%) due to anatomic variations caused by setup inaccuracy, organ deformation, tumour shrinkage, or weight loss (or a combination of these) were observed for the critical organs. Conclusions: The methodology we established affords an objective dosimetric basis for the clinical decision on whether a replanning is necessary during the course of treatment and provides a valuable platform for adaptive therapy in future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Voxel-Based Dose Reconstruction for Total Body Irradiation With Helical TomoTherapy

Purpose: We have developed a megavoltage CT (MVCT)-based dose reconstruction strategy for total body irradiation (TBI) with helical TomoTherapy (HT) using a deformable registration model to account for the patient's interfraction changes. The proposed technique serves as an efficient tool for delivered dose verification and, potentially, plan adaptation. Methods and Materials: Four patients with acute myelogenous leukemia treated with TBI using HT were selected for this study. The prescription was 12 Gy, 2 Gy/fraction, twice per day, given at least 6 h apart. The original plan achieved coverage of 80% of the clinical target volume (CTV) by the 12 Gy isodose surface. MVCTs were acquired prior to each treatment. Regions of interest were contoured on each MVCT. The dose for each fraction was calculated based on the MVCT using the HT planned adaptive station. B-spline deformable registration was conducted to establish voxel-to-voxel correspondence between the MVCT and the planning CT. The resultant deformation vector was employed to map the reconstructed dose from each fraction to the same point as the plan dose, and a voxel-to-voxel summed dose from all six fractions was obtained. The reconstructed dose distribution and its dosimetric parameters were compared with those of the original treatment plan. Results: While changes in CTV contours occurred in all patients, the reconstructed dose distribution showed that the dose-volume histogram for CTV coverage was close (<1.5%) to that of the original plan. For sensitive structures, the differences between the reconstructed and the planned doses were less than 3.0%. Conclusion: Voxel-based dose reconstruction strategy that takes into account interfraction anatomical changes using MVCTs is a powerful tool for treatment verification of the delivered doses. This proposed technique can also be applied to adaptive TBI therapy using HT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical tomography reconstruction algorithm with the finite element method: An optimal approach with regularization tools

Highlights: •New strategies to improve the accuracy of the reconstruction through mesh and finite element parameterization. •Use of gradient filtering through an alternative inner product within the adjoint method. •An integral form of the cost function is used to make the reconstruction compatible with all finite element formulations, continuous and discontinuous. •Gradient-based algorithm with the adjoint method is used for the reconstruction. -- Abstract: Optical tomography is mathematically treated as a non-linear inverse problem where the optical properties of the probed medium are recovered through the minimization of the errors between the experimental measurements and their predictions with a numerical model at the locations of the detectors. According to the ill-posed behavior of the inverse problem, some regularization tools must be performed and the Tikhonov penalization type is the most commonly used in optical tomography applications. This paper introduces an optimized approach for optical tomography reconstruction with the finite element method. An integral form of the cost function is used to take into account the surfaces of the detectors and make the reconstruction compatible with all finite element formulations, continuous and discontinuous. Through a gradient-based algorithm where the adjoint method is used to compute the gradient of the cost function, an alternative inner product is employed for preconditioning the reconstruction algorithm. Moreover, appropriate re-parameterization of the optical properties is performed. These regularization strategies are compared with the classical Tikhonov penalization one. It is shown that both the re-parameterization and the use of the Sobolev cost function gradient are efficient for solving such an ill-posed inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave-assisted reconstruction of Ni,Al hydrotalcite-like compounds

The microwave-assisted reconstruction of Ni,Al hydrotalcite-like compounds (HTlcs) with Ni/Al molar ratios 2/1 and 3/1 has been studied. Mixed oxides obtained after calcination of the HTlcs are immersed in three different solutions containing carbonate, distilled water and an aqueous NH{sub 3} solution, and then heated at different temperatures for increasing periods of time under microwave radiation. The evolution of the structure during the treatment is followed by powder X-ray diffraction, FT-IR and vis-UV spectroscopies and SEM and TEM microscopies. Full recovery of the original layered structure is achieved in short periods of time for the 2/1 samples when the calcined HTlcs are rehydrated in the Na{sub 2}CO{sub 3} solution, but more drastic conditions are necessary for the 3/1 samples and the reconstruction seems not to be complete. Finally, only a partial reconstruction is observed in distilled water or NH{sub 3} aqueous solution. - Graphical abstract: The microwave-assisted reconstruction of Ni,Al HTlcs with Ni/Al molar ratios 2/1 and 3/1 has been studied. Full recovering of the original layered structure is achieved in short periods of time for the 2/1 in the Na{sub 2}CO{sub 3} solution, but more drastic conditions are necessary for the 3/1 samples and the reconstruction seems not to be completed. Only a partial reconstruction is observed in distilled water or NH{sub 3} aqueous solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In induced reconstructions of Si(1 1 1) as superlattice matched epitaxial templates for InN growth

Graphical abstract: Display Omitted Highlights: ► A novel growth method to form InN at low growth temperatures. ► Use of Si reconstruction as a growth template for group III nitrides. ► Band gap variation of InN – Moss–Burstein shift – non-parabolic conduction band for InN. ► Super lattice matching epitaxy of metal induced reconstructions with III–V unit cell. -- Abstract: Indium induced surface reconstructions of Si(1 1 1)-7 × 7 are used as templates to grow high quality InN. We grow InN on Si(1 1 1)-7 × 7, Si(1 1 1)-4 × 1-In and Si(1 1 1)-1 × 1-In reconstructed surfaces and study the quality of the films formed using complementary characterization tools. InN grown on Si(1 1 1)-1 × 1-In reconstruction shows superior film quality with lowest band-edge emission having a narrow full width at half maximum, intense and narrow 0 0 0 2 X-ray diffraction, low surface roughness and carrier concentration an order lower than other samples. We attribute the high quality of the film formed at 300 °C to the integral matching of InN and super lattice dimensions, we also study the reasons for the band gap variation of InN in the literature. Present study demonstrates the proposed Superlattice Matched Epitaxy can be a general approach to grow good quality InN at much lower growth temperature on compatible In induced reconstructions of the Si surface.

36 MATERIALS SCIENCE↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗