Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ramping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

High temperature seal for large structural movements

A high temperature sealing system is operative to seal an interface between adjacent hot structures and to minimize parasitic flow between such structures that move relative to one another in-plane or out-of-plane. The sealing system may be used to seal thrust-directing ramp structures of a reusable launch vehicle and includes a channel and a plurality of movable segmented sealing elements. Adjacent ramp structures include edge walls which extend within the channel. The sealing elements are positioned along the sides of the channel and are biased to engage with the inner surfaces of the ramp structures. The segmented sealing elements are movable to correspond to the contour of the thrust-directing ramp structures. The sealing system is operative to prevent high temperature thrust gases that flow along the ramp structures from infiltrating into the interior of the vehicle.

Steinetz, Bruce M.↗

ARTEMIS Observations of Plasma Waves in Laminar and Perturbed Interplanetary Shocks

The ‘Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon's Interaction with the Sun’ (ARTEMIS) mission provides a unique opportunity to study the structure of interplanetary shocks and the associated generation of plasma waves with frequencies between ~50-8000 Hz due to its long duration electric and magnetic field burst waveform captures. We compare wave properties and occurrence rates at 11 quasi-perpendicular interplanetary shocks with burst data within 10 minutes (~3200 proton gyroradii upstream, ~1900 downstream) of the shock ramp. A perturbed shock is defined as possessing a large amplitude whistler precursor in the quasi-static magnetic field with an amplitude greater than ⅓ the difference between the upstream and downstream average magnetic field magnitudes; laminar shocks lack these large precursors and have a smooth, step function-like transition. In addition to wave modes previously observed, including ion acoustic, whistler, and electrostatic solitary waves, waves in the ion acoustic frequency range that show rapid temporal frequency change are common. Three shocks had burst captures in the ramp; of these, the two laminar shocks with burst data in the ramp contained a wide range of large amplitude wave modes in the ramp whereas the one perturbed shock contained no such waves. Thus, energy dissipation through wave-particle interactions is more prominent in these two laminar shocks than in the perturbed shock. Based on observations from all 11 shocks, the The wave occurrence rates for laminar shocks are higher in the transition region, especially the ramp, than downstream. In contrast, perturbed shocks have approximately 2-3 times the wave occurrence rate downstream than laminar shocks.

L. A. Davis↗

Using Regionalized Air Quality Model Performance and Bayesian Maximum Entropy Data Fusion to Map Global Surface Ozone Concentration and Associated Uncertainty

Estimates of ground-level ozone concentrations have been improved through data fusion of observations and atmospheric chemistry models. Our previous global ozone estimates for the Global Burden of Disease study corrected for bias uniformly across continents and then corrected near monitoring stations using the Bayesian Maximum Entropy (BME) framework for data fusion. Here, we use the Regionalized Air Quality Model Performance (RAMP) framework to correct model bias over a much larger spatial range than BME can, accounting for the spatial inhomogeneity of bias and nonlinearity as a function of modeled ozone. RAMP bias correction is applied to a composite of 9 global chemistry-climate models, based on the nearest set of monitors. These estimates are then fused with observations using BME, which matches observations at measurement stations, with the influence of observations declining with distance in space and time. We create global ozone maps for each year from 1990 to 2017 at fine spatial resolution. RAMP is shown to create unrealistic discontinuities due to the spatial clustering of ozone monitors, which we overcome by applying a weighting for RAMP based on the number of monitors nearby. Incorporating RAMP before BME has little effect on model performance near stations, but strongly increases R 2 by 0.15 at locations farther from stations, shown through a checkerboard cross-validation. Corrections to estimates differ based on location in space and time, confirming heterogeneity. We quantify the likelihood of exceeding selected ozone levels, finding that parts of the Middle East, India, and China are most likely to exceed 55 parts per billion (ppb) in 2017. About 96% of the global population was exposed to ozone levels above the World Health Organization guideline of 60 µg m −3 (30 ppb) in 2017. Our annual fine-resolution ozone estimates may be useful for several applications including epidemiology and assessments of impacts on health, agriculture, and ecosystems.

Ozone↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗

Operando X-Ray Diffraction During High Temperature Electrolysis

This work presents the design, development, and deployment of an operando X-ray diffraction (XRD) system for high-temperature electrolysis (HTE), enabling real-time characterization of solid oxide electrolysis cells (SOECs) under true operational conditions. The integration of an HTE test stand within a synchrotron radiation environment, mimicking the conditions of a laboratory setup, aims to enhance our understanding of the degradation processes affecting the performance and longevity of SOECs. Utilizing a custom furnace and a high precision motor stack assembly at the Stanford Synchrotron Radiation Lightsource (SSRL), the system revealed unparalleled insights into the structural evolution of SOEC components through various operational stages, including initial heat ramp, cell reduction, fuel ramp, and wet electrolysis. Initial results demonstrate the significant impact of the initial heating and cooling on secondary phase formation within the SOEC, highlighting the utility of operando XRD for developing more efficient and durable hydrogen production technologies.

08 HYDROGEN↗

Depletion of the Protein Hydration Shell with Increasing Temperature Observed by Small-Angle X-ray Scattering and Molecular Simulations

The hydration shell is an integral part of proteins since it plays key roles in conformational transitions, molecular recognition, and enzymatic activity. While the dynamics of the hydration shell have been described by spectroscopic techniques, the structure of the hydration shell remains less understood due to the lack of hydration shell-sensitive structural probes with high spatial resolution. We combined temperature-ramp small-angle X-ray scattering (T-ramp SAXS) from 255 to 335 K with molecular simulations to demonstrate that the hydration shells of the IgG-binding domain of Protein G (GB3) and the villin headpiece are remarkably temperature-sensitive. For proteins in the folded state, T-ramp SAXS data and explicit-solvent SAXS predictions consistently demonstrate decays of protein contrasts and radii of gyration with increasing temperature, which are shown to reflect predominantly temperature-sensitive, depleting hydration shells. The depletion is caused not merely by enhanced disorder within the hydration shells but also by partial displacements of surface-coordinated water molecules. Together, T-ramp SAXS and explicit-solvent SAXS calculations provide a novel structural view of the protein hydration shell, which underlies temperature-dependent processes such as cold denaturation, thermophoresis, or biomolecular phase separation.

electron density↗

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics↗

Combining Machine Learning and Comparative Effectiveness Methodology to Study Primary Care Pharmacotherapy Pathways for Veterans With Depression

Our objective is to demonstrate an innovative method combining machine learning with comparative effectiveness research techniques and to investigate a hitherto unstudied question about the effectiveness of common prescribing patterns. For Operation Enduring Freedom/Operation Iraqi Freedom veterans with major depressive disorder, we generate pharmacotherapy pathways (of antidepressants) using process mining and machine learning. We select the medication episodes that were started at subtherapeutic doses by the first assigned primary care physician and observe the paths that those medication episodes follow. Using 2-stage least squares, we test the effectiveness of starting at a low dose and staying low for longer versus ramping up fast while balancing observable and unobservable characteristics of patients and providers through instrumental variables. We leverage predetermined provider practice patterns as instruments. We collected outpatient pharmacy data for selective serotonin reuptake inhibitors and selective norepinephrine reuptake inhibitors, patient and provider characteristics (as control variables), and the instruments for our cohort. All data were extracted for the period between 2006 and 2020. There is a statistically significant positive effect (0.68, 95% CI 0.11–1.25) of “ramping up fast” on engagement in care. When we examine the effect of “ramping up slow”, we see an insignificant negative impact on engagement in care (−0.82, 95% CI −1.89 to 0.25). As expected, the probability of drop-out also seems to have a negative effect on engagement in care (−0.39, 95% CI −0.94 to 0.17). We further validate these results by testing with medication possession ratios calculated periodically as an alternative engagement in care metric. Our findings contradict the “Start low, go slow” adage, indicating that ramping up the dose of an antidepressant faster has a significantly positive effect on engagement in care for our population.

60 APPLIED LIFE SCIENCES↗

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

Surrogate model for third-integer resonance extraction at the Fermilab Delivery Ring

We present an ongoing work in which a surrogate model is being developed to reproduce the response dynamics of the third-integer resonant extraction process in the Delivery Ring (DR) at Fermilab. This is in pursuit of smoothly extracting circulating beam to the Mu2e Experiment’s production target, whereby the goal is to extract a uniform slice of the circulating 1e12 protons in the DR over 25,000 turns (43 ms). The DR contains 3 harmonic sextupoles that excite a third-integer resonance and three fast, tune-ramping quadrupole magnets that drive the horizontal tune towards the 29/3 resonance. In our initial work, the surrogate model trains on a semi-analytical simulation provided in the same format as live data. Using Reinforcement Learning (and other potential ML methods), the trained surrogate acts as the “environment” in which a simple ML control agent could learn to dynamically adjust the quadrupole ramp at 430 break points within the 43 microsecond spill window. The controller will be hosted on a dedicated Arria 10 FPGA. In this work, we report the accuracy and fidelity of the surrogate model in comparison to the response dynamics of the physics simulator.

Narayanan, Aakaash [Fermilab]↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Ta compressibility to 20+ Mbar

Developing techniques for experimentally constraining equation of state (EOS) models for important programmatic materials under extreme conditions is vital for advancing our modeling and predictive capabilities. Tantalum is a frequently used standard material for both calibration and testing, and this report describes our work to both measure Ta compressibility to very high pressures and densities using the Ramp Compression Equation of State platform on the National Ignition Facility (NIF). Using a series of seven shots, increasing in peak pressure with each shot, we have made absolute measurements of the compressibility of Ta along the ramp compression path up to 2.3 TPa. Previous experimental measurements constrained the cold compressibility up to ~400 GPa, and there is a spread in the EOS models above that pressure. To improve communication and collaboration between the experimental team and the EOS development group, these new data, along with other experimental and theoretical constraints, were used to develop a Ta equation of state table, M73000. This report first describes the experimental measurements made at the NIF, and then discusses the construction of the EOS model. The ramp compression data can be found in tabular form in Appendix A. Appendix B contains some additional experimental details. In Appendix C we include some additional details on the EOS modeling. At the end of this document, we have attached a detailed report on the NIF ramp compression platform itself and in the main text referenced specific sections for additional details.

36 MATERIALS SCIENCE↗

Impact of Cooling Rate and Thermal Mass on Supercooling in a Salt-Hydrogel Complex for Thermal Energy Storage

Glauber’s salt is a promising phase change material for building thermal management because of its high latent heat, acceptable melting temperature of 32.3 °C for indoor air1,2. Despite these advantages, the practical application of Glauber’s salt in thermal energy storage systems is still challenging due to supercooling and phase segregation1–3. Here, we report the impact of temperature ramp rate and thermal mass on the supercooling of Glauber’s salt through the DSC and T-history experiment. The ramp rate effect was studied with a wide range of ramp rates in 1 to 10 °C/min in DSC and 1 to 4 °C/min in the T-history experiment. The thermal mass effect was investigated by comparing DSC and T-history experiment. The latent heat was also analyzed for different ramp rates and thermal mass conditions. The melting temperatures of Glauber’s salt from the two techniques were identical while freezing temperatures were different because of the thermal mass effect. During freezing in the T-history experiment, the latent heat was reduced by around 75% to the latent heat in melting due to supercooling and phase segregation. To overcome this bottleneck, we developed a novel hydrogel complex that reduces the supercooling and prevents phase segregation to maintain volumetric energy density for 100 cycles. Thermodynamic analysis accounting for composition shows that a higher salt composition can further enhance the volumetric energy storage density. For example, a 10% increase in the weight percentage of salt leads to about 50% enhancement in volumetric energy storage density. References: 1. D. R. Biswas, Solar Energy. 19, 99–100 (1977). 2. S. M. Hasnain, Energy Conversion and Management. 39, 1127–1138 (1998). 3. Byung Chul Shin, Sang Done Kim, P. Won-Hoon, Energy. 14, 921–930 (1989).

inorganic, thermodynamics↗

Dynamic Multipoles in the RCS

The Rapid Cycling Synchrotron (RCS) of the Electron--Ion Collider (EIC) will accelerate polarized electrons up to 18 GeV at a repetition rate of 1 Hz. Dynamic multipoles driven by eddy currents in the vacuum chamber can affect beam dynamics and polarization preservation during the energy ramp. Building on the analytical treatment of S.Y. Lee for a ramped normal-conducting dipole magnet, we use conformal transformations to derive compact expressions for dynamic multipoles in higher-order ramped magnets with circular beam pipes. We further derive analytical frequency-domain transfer functions for both self-response and cross-response multipoles, providing compact dynamical models for their evolution during arbitrary ramp waveforms. The resulting analytical predictions are benchmarked against finite-element simulations, including the effects of practical pole geometry and beam-pipe misalignment. Finally, the expected dynamic multipoles in the RCS magnets are estimated and their implications for beam dynamics and polarization preservation are discussed.

43 PARTICLE ACCELERATORS↗

Simple first order data compression processor concept

Data-compression processing systems based on an analog-to-digital converter /ADC/, includes a qualitative comparator for comparison of the ADC output with a ramp generator, which is connected as a bidirectional binary counter with selective inputs. A bidirectional ramp counter selects the proper ramp through a ramp generator selection network.

Anderson, T. O.↗

The microprocessor-based synthesizer controller

Implementation and performance of the microprocessor-based controllers and Dana Digiphase Synthesizer (DCO) installed in the Deep Space Network exciter in the 64-meter and 34-meter subnets to support uplink tuning required for the Voyager-Saturn Encounter is discussed. Test data in tests conducted during the production of the controllers verified the design objective for phase control accuracy of 10 to the - 12 power cycles in eight hours during ramping. Tests conducted require a phase error between a theoretical calculated value and the actual phase of no greater than + or - 1 cycle. Tests included (1) a ramp over a period of eight hours using a ramp rate which covers the synthesizer tuning range (40-51 MHz) and (2) a ramp sequence using the maximum rate (+ or kHz/s) over the tuning range.

Wick, M. R.↗