Mission Radiation Environment Modeling and Analysis: Avionics Trade Study for GCD Rad-Neuro Project

The two main objectives of this trade study are characterizing the mission radiation environment for multiple Design Reference Missions (DRM) and analysis of radiation effects on avionics with the goal of producing radiation tolerant Neuromorphic Computing processor chips with innovative radiation-induced fault mitigation. The NASA process for defining radiation requirements for flight avionics is applied to this domain. The effects of trapped protons and electrons in the Van Allen radiation belts predominates in Low-Earth-Orbit (LEO) and the solar wind, solar flares and Galactic Cosmic Rays (GCRs) are the dominant radiation challenge in the open space between the planets of our solar system. The nature and energy of the particles that cause circuit upset and failure is very different in the two regimes. Two results are produced from the radiation models: determining the Total Integrated Dose (TID) experienced by avionics for a given DRM and predicting the Single Event Effects (SEE) rates for avionics during high rate exposure. These tools are applied to existing semiconductors and can be used for predicting the radiation performance of future semiconductors based on early radiation testing of new devices.

Space Radiation↗

Evaluation of the Leon3 Soft-Core Processor Within a Xilinx Radiation-Hardened Field-Programmable Gate Array

The purpose of this document is to summarize the work done to evaluate the performance of the Leon3 soft-core processor in a radiation environment while instantiated in a radiation-hardened static random-access memory based field-programmable gate array. This evaluation will look at the differences between two soft-core processors: the open-source Leon3 core and the fault-tolerant Leon3 core. Radiation testing of these two cores was conducted at the Texas A&M University Cyclotron facility and Lawrence Berkeley National Laboratory. The results of these tests are included within the report along with designs intended to improve the mitigation of the open-source Leon3. The test setup used for evaluating both versions of the Leon3 is also included within this document.

97 MATHEMATICS AND COMPUTING↗

Current State of Domestic Heavy Ion Test Facilities

We present the current status of United States domestic heavy ion single-event effects (SEE) radiation test facilities, including general perspectives on near- and mid-term needs for both capacity and capabilities.

Jonathan Pellish↗

Radiation Therapy Intensification for Solid Tumors: A Systematic Review of Randomized Trials

Purpose: To systematically review the outcomes of randomized trials testing radiation therapy (RT) intensification, including both dose escalation and/or the use of altered fractionation, as a strategy to improve disease control for a number of malignancies. Methods and Materials: We performed a literature search to identify randomized trials testing RT intensification for cancers of the central nervous system, head and neck, breast, lung, esophagus, rectum, and prostate. Findings were described qualitatively. Where adequate data were available, pooled estimates for the effect of RT intensification on local control (LC) or overall survival (OS) were obtained using the inverse variance method. Results: In primary central nervous system tumors, esophageal cancer, and rectal cancer, randomized trials have not demonstrated that RT intensification improves clinical outcomes. In breast cancer and prostate cancer, dose escalation has been shown to improve LC or biochemical disease control but not OS. Radiation therapy intensification may improve LC and OS in head and neck and lung cancers, but these benefits have generally been limited to studies that did not incorporate concurrent chemotherapy. Conclusions: In randomized trials, the benefits of RT intensification have largely been restricted to trials in which concurrent chemotherapy was not used. Novel strategies to optimize the incorporation of RT in the multimodality treatment of solid tumors should be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current and Perspective Applications of Dense Plasma Focus Devices

Dense Plasma Focus (DPF) devices' applications, which are intended to support the main-stream large-scale nuclear fusion programs (NFP) from one side (both in fundamental problems of Dense Magnetized Plasma physics and in its engineering issues) as well as elaborated for an immediate use in a number of fields from the other one, are described. In the first direction such problems as self-generated magnetic fields, implosion stability of plasma shells having a high aspect ratio, etc. are important for the Inertial Confinement Fusion (ICF) programs (e.g. as NIF), whereas different problems of current disruption phenomenon, plasma turbulence, mechanisms of generation of fast particles and neutrons in magnetized plasmas are of great interest for the large devices of the Magnetic Plasma Confinement--MPC (e.g. as ITER). In a sphere of the engineering problems of NFP it is shown that in particular the radiation material sciences have DPF as a very efficient tool for radiation tests of prospect materials and for improvement of their characteristics. In the field of broad-band current applications some results obtained in the fields of radiation material sciences, radiobiology, nuclear medicine, express Neutron Activation Analysis (including a single-shot interrogation of hidden illegal objects), dynamic non-destructive quality control, X-Ray microlithography and micromachining, and micro-radiography are presented. As the examples of the potential future applications it is proposed to use DPF as a powerful high-flux neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration for innovative experiments in nuclear physics, for the goals of radiation treatment of malignant tumors, for neutron tests of materials of the first wall, blankets and NFP device's constructions (with fluences up to 1 dpa per a year term), and ns pulses of fast electrons, neutrons and hard X-Rays for brachytherapy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Clouds and Water Vapor in the Climate System: Remotely Piloted Aircraft and Satellites

The objective of this work was to attack unanswered questions that lie at the intersection of radiation, dynamics, chemistry and climate. Considerable emphasis was placed on scientific collaboration and the innovative development of instruments required to address these scientific issues. The specific questions addressed include: Water vapor distribution in the Tropical Troposphere: An understanding of the mechanisms that dictate the distribution of water vapor in the middle-upper troposphere; Atmospheric Radiation: In the spectral region between 200 and 600/cm that encompasses the water vapor rotational and continuum structure, where most of the radiative cooling of the upper troposphere occurs, there is a critical need to test radiative transfer calculations using accurate, spectrally resolved radiance observations of the cold atmosphere obtained simultaneously with in situ species concentrations; Thin Cirrus: Cirrus clouds play a central role in the energy and water budgets of the tropical tropopause region; Stratosphere-Troposphere Exchange: Assessment of our ability to predict the behavior of the atmosphere to changes in the boundary conditions defined by thermal, chemical or biological variables; Correlative Science with Satellite Observations: Linking this research to the developing series of EOS observations is critical for scientific progress.

Anderson, James G.↗

A 2.2 sq m /24 sq ft/ self-controlled deployable heat pipe radiator - Design and test

An all heat pipe, deployable radiator has been developed which can effectively control pumped fluid loop temperatures under varying loads using variable conductance panel heat pipes. The 2.2 sq m (24 sq ft) aluminum panel can be coupled to either a fluid header or a flexible heat pipe header capable of transporting 850 watts in a 90-deg bent configuration. Test results support the feasibility of using this system to passively control Freon-21 loop temperatures.

Edelstein, F.↗

Single Event Effects Test Results for the Actel ProASIC Plus and Altera Stratix-II Field Programmable Gate Arrays

This work describes radiation testing of Actel's ProASIC Plus and Altera's Stratix-II FPGAs. The Actel Device Under Test (DUT) was a ProASIC Plus APA300-PQ208 nonvolatile, field reprogrammable device which is based on a 0.22micron flash-based LVCMOS technology. Limited investigation has taken place into flash based FPGA technologies, therefore this test served as a preliminary reference point for various SEE behaviors. The Altera DUT was a Stratix-II EP2S60F1020C4. Single Event Upset (SEU) and Single Event Latchup (SEL) were the focus of these studies. For the Actel, a latchup test was done at an effective LET of 75.0 MeV-sq cm/mg at room temperature, and no latchup was detected when irradiated to a total fluence of 1 x 10(exp 7) particles/sq cm. The Altera part was shown to latchup at room temperature.

heavy ions↗

Characterization Testing of Lockheed Martin High-Power Micro Pulse Tube Cryocooler

This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

Rodriguez, Jose I.↗

The Clinical Development of Molecularly Targeted Agents in Combination With Radiation Therapy: A Pharmaceutical Perspective

Summary: This paper explores historical and current roles of pharmaceutical industry sponsorship of clinical trials testing radiation therapy combinations with molecularly targeted agents and attempts to identify potential solutions to expediting further combination studies. An analysis of clinical trials involving a combination of radiation therapy and novel cancer therapies was performed. Ongoing and completed trials were identified by searching the (clinicaltrials.gov) Web site, in the first instance, with published trials of drugs of interest identified through American Society of Clinical Oncology, European CanCer Organisation/European Society for Medical Oncology, American Society for Radiation Oncology/European Society for Therapeutic Radiology and Oncology, and PubMed databases and then cross-correlated with (clinicaltrials.gov) protocols. We examined combination trials involving radiation therapy with novel agents and determined their distribution by tumor type, predominant molecular mechanisms examined in combination to date, timing of initiation of trials relative to a novel agent's primary development, and source of sponsorship of such trials. A total of 564 studies of targeted agents in combination with radiation therapy were identified with or without concomitant chemotherapy. Most studies were in phase I/II development, with only 36 trials in phase III. The tumor site most frequently studied was head and neck (26%), followed by non-small cell lung cancer. Pharmaceutical companies were the sponsors of 33% of studies overall and provided support for only 16% of phase III studies. In terms of pharmaceutical sponsorship, Genentech was the most active sponsor of radiation therapy combinations (22%), followed by AstraZeneca (14%). Most radiation therapy combination trials do not appear to be initiated until after drug approval. In phase III studies, the most common (58%) primary endpoint was overall survival. Collectively, this analysis suggests that such trials are not given priority by pharmaceutical companies. The potential reasons for this and some challenges and possible solutions are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation problems associated with Skylab

Radiation tests were conducted on the various types of Skylab film to establish the total radiation dosages compatible with an acceptable level of film fogging, and on the S190 borosilicate window to establish radiation limits for an acceptable darkening level. The results verified that most of the films would be unusable when returned to earth, and that the borosilicate window would be darkened beyond allowable limit, unless additional protection was provided. The operational solutions to these problems involve protecting the film with five film vaults and protecting the window with a radiation shield. The largest vault is made of aluminum and weighs over 2000 lb (its thickest compartment wall is 3.4 in.). The window radiation shield is a light honeycomb structure which is swung away for limited astronaut viewing or when the S190 experiment is in operation. Although the shield is light weight, it is heavy enough to stop the large number of low energy electrons making up a major part of the external environment and which are potentially damaging to the window. A brief description is given of the Skylab mission and some of the associated experiments. The radiation environment the spacecraft will encounter is discussed.

Braly, J. E.↗

The NASA Microelectronics Space Radiation Effects Program (MSREP) at the Jet Propulsion Laboratory

The primary objective of the Microelectronics Space Radiation Effects Program (MSREP) at the Jet Propulsion Laboratory (JPL) is to assist NASA in the selection of radiation hardened microelectronic parts for insertion in NASA space systems through radiation testing and research. Prior to presenting examples of the research and testing on Single Event Effects (SEE) and Total Ionizing Dose (TID) effects, the space radiation environment and radiation requirements for the CRAFT/Cassini program, a typical JPL space project, are discussed.

Barnes, C.↗

Software Graphics Processing Unit (sGPU) for Deep Space Applications

A graphics processing capability will be required for deep space missions and must include a range of applications, from safety-critical vehicle health status to telemedicine for crew health. However, preliminary radiation testing of commercial graphics processing cards suggest they cannot operate in the deep space radiation environment. Investigation into an Software Graphics Processing Unit (sGPU)comprised of commercial-equivalent radiation hardened/tolerant single board computers, field programmable gate arrays, and safety-critical display software shows promising results. Preliminary performance of approximately 30 frames per second (FPS) has been achieved. Use of multi-core processors may provide a significant increase in performance.

McCabe, Mary↗

The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

43 PARTICLE ACCELERATORS↗

Modeling UV Radiation Feedback from Massive Stars. I. Implementation of Adaptive Ray-tracing Method and Tests [Modeling UV Radiation Feedback from Massive Stars: I. Implementation of Adaptive Ray Tracing Algorithm]

Here, we present an implementation of an adaptive ray-tracing (ART) module in the Athena hydrodynamics code that accurately and efficiently handles the radiative transfer involving multiple point sources on a three-dimensional Cartesian grid. We adopt a recently proposed parallel algorithm that uses nonblocking, asynchronous MPI communications to accelerate transport of rays across the computational domain. We validate our implementation through several standard test problems, including the propagation of radiation in vacuum and the expansions of various types of H II regions. Additionally, scaling tests show that the cost of a full ray trace per source remains comparable to that of the hydrodynamics update on up to $\sim {10}^{3}$ processors. To demonstrate application of our ART implementation, we perform a simulation of star cluster formation in a marginally bound, turbulent cloud, finding that its star formation efficiency is 12% when both radiation pressure forces and photoionization by UV radiation are treated. We directly compare the radiation forces computed from the ART scheme with those from the M 1 closure relation. Although the ART and M 1 schemes yield similar results on large scales, the latter is unable to resolve the radiation field accurately near individual point sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose.

Martin, K. E.↗

Latest trends in parts SEP susceptibility from heavy ions

JPL and Aerospace have collected a third set of heavy-ion single-event phenomena (SEP) test data since their last joint IEEE publications in December 1985 and December 1987. Trends in SEP susceptibility (e.g., soft errors and latchup) for state-of-the-art parts are presented. Results of the study indicate that hard technologies and unacceptably soft technologies can be flagged. In some instances, specific tested parts can be taken as candidates for key microprocessors or memories. As always with radiation test data, specific test data for qualified flight parts is recommended for critical applications.

Nichols, Donald K.↗

Total-dose radiation effects data for semiconductor devices (1989 supplement)

Steady state, total dose radiation test data are provided for electronic designers and other personnel using semiconductor devices in a radiation environment. The data are presented in graphic and narrative formats. Two primary radiation source types were used: Cobalt-60 gamma rays and a Dynamitron electron accelerator capable of delivering 2.5 MeV electrons at a steady rate.