Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Methods and systems for electromagnetic near-field coherent sensing

The present disclosure may be embodied as methods and/or systems for non-contact measuring of an on-body and/or inside-body motion of an individual. A sensing signal is provided within a near-field coupling range of a motion to be measured. In this way, a measurement signal may be generated as the sensing signal modulated by the motion. The sensing signal may be an ID-modulated signal. In some embodiments, the sensing signal is a backscattered RFID link provided a wireless tag. A downlink signal may be provided to power the wireless tag. The sensing signal may be a harmonic of the downlink signal. The measurement signal is detected. The motion is measured based on the measurement signal. The measurement signal may be detected as far-field radiation after transmission through a source of the motion. The measurement signal may be detected as reflected from a source of the motion as antenna reflection.

Hui, Xiaonan↗

A Resonant Metamaterial Line Array for Ultrasound Compressive Imaging

Abstract Acoustic metamaterials have been proposed for numerous applications including subwavelength imaging, impedance matching, and lensing. Yet, their application in compressive sensing and imaging has not been fully investigated. When metamaterials are used as resonators at certain frequencies, they can generate random radiation patterns in the transmitted waves from the transducers and received waves from a target. Compressive sensing favors such randomness inasmuch as it can increase incoherence by decreasing the amount of mutual information between any two different measurements. This study aims at assessing whether the use of resonating metamaterial unit cells in a single-layered non-optimized array between a number of ultrasound transceivers and targets can improve the sensing capacity, point-spread function of the sensing array (their beam focusing ability), and imaging performance in point-like target detection. The theoretical results are promising and can open the way for more efficient metamaterial designs with the aim of enhancing ultrasound imaging with lower number of transceivers compared to the regular systems.

Acoustics↗

Search for Dark Matter using mono-Higgs and the ATLAS Pixel Detector (Final Report)

A large component of the mass-energy of the universe is composed of dark matter (DM), whose properties and interactions with known particles are not yet understood. Searches for DM at the Large Hadron Collider (LHC) provide important information, complementary to direct and indirect detection experiments, that is necessary to determine whether an observed signal indeed stems from DM. Furthermore, the discovery of the Higgs boson provides a unique avenue to search for DM because the potential interaction of the Higgs with DM would lead to the unique signature of a Higgs boson recoiling against DM. This process is typically referred to as mono-Higgs because DM does not interact strongly with most known particles and will therefore pass unseen through the detector, leading to a single detected Higgs boson and a large imbalance of momentum. Due to the strength of the interactions of the Higgs with Standard Model particles, it is unlikely for a Higgs boson to be radiated from initial state quarks. Therefore, the observation of this process would provide direct insight into the mechanism by which DM couples to known particles. The objective of this research program is to search for the dark matter particles produced in association with a Higgs boson at the LHC using the ATLAS (A Toroidal LHC Apparatus) detector, specifically when the Higgs boson decays to two bottom quarks. This research will benefit greatly from the development of innovative identification techniques of boosted Higgs bosons. The program includes the upgrade of the ATLAS Pixel readout system, which is critical to maintain high performance of tracking, vertexing, and boosted Higgs tagging in the planned higher luminosity run of the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

Accounting for Changes in Radiation Improves the Ability of SIF to Track Water Stress-Induced Losses in Summer GPP in a Temperate Deciduous Forest

Global observations of solar-induced chlorophyll fluorescence (SIF) are available from multiple satellite platforms, and SIF is increasingly used as a proxy for photosynthetic activity and ecosystem productivity. Because the relationship between SIF and gross primary productivity (GPP) depends on a variety of factors including ecosystem type and environmental conditions, it is necessary to study SIF observations across various spatiotemporal scales and ecosystems. To explore how SIF signals relate to productivity over a temperate deciduous forest, we deployed a PhotoSpec spectrometer system at the University of Michigan Biological Station AmeriFlux site (US-UMB) in the northern Lower Peninsula of Michigan during the 2018 and 2019 growing seasons. We found that SIF correlated with GPP across diurnal and seasonal cycles (R 2 = 0.61 and 0.64 for 90-min- and daily-averaged data), but that SIF signals were more strongly related to downwelling radiation than GPP (R 2 = 0.91 for daily-averaged data). The dependence of SIF on radiation obscured the impact of intraseasonal drought in the SIF timeseries, but drought stress was apparent as a decrease in relative SIF, which exhibited a stronger correlation with GPP (R 2 = 0.56) than other remotely sensed data over the drought period. These results highlight the potential of SIF for detecting stress-induced losses in forest productivity. Additionally, we found that the red:far-red SIF ratio did not exhibit a response to water stress-induced losses in productivity, but was largely driven by seasonal and interannual changes in canopy structure, as well as by synoptic changes in downwelling radiation.

54 ENVIRONMENTAL SCIENCES↗

A Novel Segmentation Algorithm for the ARM User Facility All-Sky Imagers Using Machine Learning Applications

Cloud cover plays a pivotal role in modulating the Earth's energy budget through the reflection of incoming solar radiation and the trapping of outgoing longwave radiation. Ground-based all-sky imagers offer an objective assessment of cloud cover that can be used to estimate solar irradiance, classify cloud types, track cloud movement, and serve as a benchmark 10 for the evaluation of satellite and reanalysis data products. The Atmospheric Radiation Measurement (ARM) user facility has utilized all-sky imagers for more than 25 years to monitor cloud cover and augment its comprehensive suite of atmospheric measurements. Following the retirement of its Total Sky Imager (TSI), ARM recently deployed the TSI’s successor, the All Sky Imager (ASI-16 camera systems). To provide a smooth transition and continuity to the vast amount of knowledge gathered by the TSI over the years, while addressing typical deployment issues, we developed a novel pixel segmentation algorithm, 15 the ASI Sky Cover (ASISKYCOVER). ASISKYCOVER builds on the different strengths and properties of the TSI processing algorithm while integrating machine learning techniques, ensuring data validity and accuracy across diverse atmospheric conditions. It enhances cloud cover characterization with new features such as artifact detection and uncertainty quantification. ASISKYCOVER also includes cloud cover estimates for near-zenith (narrow field-of-view) and reduces susceptibility to false detections. This study introduces ASISKYCOVER, details its algorithm framework, and demonstrates its capabilities using a 20 year-long dataset from the ARM Southern Great Plains site. Comparisons with co-located TSI data and other ARM measurements, such as zenith-pointing radars and lidars, are presented, underscoring the ASISKYCOVER’s potential to improve cloud cover analyses and data evaluation efforts, as well as to be integrated into higher-level data products that synergize instrument suites to generate new and insightful information

Silber, Israel↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

Measuring Black Hole Light Echoes with Very Long Baseline Interferometry

Light passing near a black hole can follow multiple paths from an emission source to an observer due to strong gravitational lensing. Photons following different paths take different amounts of time to reach the observer, which produces an echo signature in the image. The characteristic echo delay is determined primarily by the mass of the black hole, but it is also influenced by the black hole spin and inclination to the observer. In the Kerr geometry, echo images are demagnified, rotated, and sheared copies of the direct image and lie within a restricted region of the image. Echo images have exponentially suppressed flux, and temporal correlations within the flow make it challenging to directly detect light echoes from the total light curve. In this Letter, we propose a novel method to search for light echoes by correlating the total light curve with the interferometric signal at high spatial frequencies, which is a proxy for indirect emission. We explore the viability of our method using numerical general relativistic magnetohydrodynamic simulations of a near-face-on accretion system scaled to M87-like parameters. We demonstrate that our method can be used to directly infer the echo delay period in simulated data. An echo detection would be clear evidence that we have captured photons that have circled the black hole, and a high-fidelity echo measurement would provide an independent measure of fundamental black hole parameters. Our results suggest that detecting echoes may be achievable through interferometric observations with a modest space-based very long baseline interferometry mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Cloud Mask Forecasts from the WRF-Solar Ensemble Prediction System: Preprint

Numerical weather prediction (NWP) models are important tools used by government agencies and the renewable energy enterprise to forecast solar radiation. Cloud prediction, a key process of NWP models, has the highest impact on the accuracy of solar forecasting. This study uses satellite observations from the National Solar Radiation Data Base (NSRDB) to evaluate the cloud mask forecast by the WRF-Solar Ensemble Prediction System (WRF-Solar EPS). Preliminary analysis of the data in 2018 demonstrates the need of further improvement in predicting thin and low-level clouds. The information obtained from this work will be used to enhance the WRF-Solar EPS in reproducing the cloud field over the contiguous U.S. and reducing solar forecasting errors.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Natural attenuation of uranium in a fluvial Wetland: Importance of hydrology and speciation

A nuclear fuel fabrication facility released 43,500 kg of uranium into a riparian wetland located on the Savannah River Site between 1955 and 1988. Studies were undertaken to evaluate hydrological and geochemical processes influencing uranium accumulation in the wetland. Gamma-radiation-mapping surveys were conducted by systematically walking over the contaminated wetland with backpacks equipped with global positioning systems and NaI gamma detectors. Based on maps compiled from >700,000 gamma spectra and eight sediment uranium depth profiles, it was determined that 94% of the released uranium remained in the wetland. The uranium in the wetland is concentrated in five multi-hectare areas along the stream, accounting for ~11% of the land area adjacent to the stream. While land type (upland or wetland) and topography provided a reasonable first approximation of where much of the uranium was deposited, hydrological watershed modeling revealed that the stream velocity was especially slow through many of the hot spots. Here, using autoradiography combined with SEM/EDX measurements of contaminated sediments, surprisingly few hot particles were detected. Instead, uranium was evenly distributed throughout the sampled sediment, suggesting that dissolved uranium had bound to sediment particles that became suspended and later deposited in low energy (low flow velocity) portions of the stream. EXAFS suggested that U atoms were present as individual ions in disordered complexes within the sediment. Furthermore, linear combination analyses suggested that the predominant component of the U(VI) was adsorbed to sediment minerals (~70%) and a minor component (~30%) was associated with organic matter phases. Furthermore, these studies show that wetlands can be extraordinarily effective at binding and retaining uranium, thereby providing a natural barrier to the transport of uranium out of a watershed. However, significant anthropogenic or climatic changes to wetlands, such as those associated with flooding, forest fires, or land use, may disrupt the complex hydrological and biogeochemical balance necessary to maintain long-term immobilization of uranium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Picosecond measurements of plastic scintillator pulse shapes from gamma-ray interactions

An understanding of the pulse shape of organic scintillators can provide insight into scintillation mechanisms and inform the selection of the optimal detector material for a given application. Although the timing properties of organic scintillators have been extensively studied, significant discrepancies persist in reported rise and decay times. New plastic scintillating media have also been developed in recent years for which no literature data exist. The goal of this work is to provide high-precision measurements of the pulse shape of a suite of fast plastic organic scintillators from Eljen Technology—EJ-200, EJ-204, EJ-208, EJ-230, EJ-232, and EJ-232Q (with 0.5% benzophenone)—under excitation from $γ$-ray sources. The contributors to the system temporal resolution were quantified, and the dominant source of uncertainty was identified as the determination of the start time of a scintillation event. A pulse shape model was applied to the reconstructed temporal distributions, and rise and decay times were extracted and compared with manufacturer specifications. This work outlines a measurement approach to obtain the pulse shape of organic scintillators in response to $γ$-rays with temporal resolution on the order of tens of picoseconds, yielding data required for modeling plastic scintillator based detection systems for a range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Origin of proton irradiation-induced deep acceptors in Al 0.70 Ga 0.30 N

Deep level defect introduction and carrier removal were characterized using steady-state photocapacitance (SSPC), deep level transient spectroscopy (DLTS) and lighted capacitance–voltage for proton irradiated n-type Al 0.70 Ga 0.30 N Schottky diodes grown by metal-organic vapor phase epitaxy on AlN-on-sapphire templates. SSPC observed deep levels in the as-grown diode with zero-phonon transition energies of 2.20, 2.65, 3.10, 3.40, and 4.65 eV relative to the conduction band minimum (E c ), and an additional deep level emerged at 1.20 eV with irradiation. Lighted capacitance–voltage measurements quantified the deep level concentration (N t ) of states detected by SSPC, and it was observed that N t increased with proton fluence only for the 1.2 and 4.65 eV levels. Carrier removal was much larger than the increase in N t of the 1.2 and 4.65 eV deep levels, suggesting that radiation-induced deep level compensators existed beyond what was detected with SSPC. DLTS detected additional, proton-induced deep acceptors at E c —0.55, 0.82, and 1.16 eV, the latter of which is likely the same 1.20 eV deep state observed by SSPC. The concentration of the E c —0.82 eV defect state was large enough to reconcile carrier removal with total deep level introduction. Comparing the E c —0.82 and 1.16 eV deep acceptor levels to previous experimental and theoretical reports suggests that their atomistic origins could be the nitrogen vacancy (V N ) and oxygen substituting on the nitrogen sub-lattice (O N ), respectively. This defect behavior contrasts starkly with GaN, where V N and O N are shallow donors, and demonstrates that the electronic properties of defects can evolve drastically within the AlGaN alloy system ranging from wide bandgap GaN to ultra-wide bandgap AlN.

Armstrong, Andrew Michael [Sandia National Laborat↗

Radioxenon signatures of molten salt reactors

Developments of molten salt reactor (MSR) technologies are making rapid progress across the globe. These reactor designs involve properly controlling radionuclides through off-gas systems. This work examines radioxenon emissions and assesses treaty detection technology to be used for monitoring. This work also includes a sensitivity study with ORIGEN on the nuclear forensic signals possible from a MSR. Multiple Isotope Ratio Comparison (MIRC) plots are used to compare the ratios of radioxenon isotopes in an MSR to a highly enriched uranium (HEU) reactor. Finally, the results show that MSR emissions may significantly overlap with signals produced in a HEU reactor and that changing reactor operations or retaining emissions in an off-gas system can significantly shift the radioxenon signature away from the HEU pulse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Strategy for NACS investment in Machine Learning

The Nuclear and Chemical Sciences (NACS) Division furnishes the expertise in the scientific areas of chemical, nuclear and isotopic sciences that are foundational in the Laboratory’s national security missions. This expertise is maintained and advanced through identification, development and application of state-of-the-art theoretical, computational and experimental methods and tools. Recent developments in artificial intelligence and machine learning (AI/ML) techniques enabled by advances in computing capabilities and widespread availability of powerful software implementations have made use of these techniques ubiquitous across both science and industry. While the scope of AI/ML applications is incredibly large and evolves very rapidly, the topics most relevant to NACS missions fall into the general category of detecting, categorizing or identifying features in large, complex datasets using either supervised or unsupervised learning. This covers both basic scientific data analysis and the development of efficient surrogate models of real-life technological systems, experimental detectors, or theoretical models. To remain at the forefront of its core scientific disciplines, NACS must both cultivate ML expertise as well as continuously explore applying this expertise to new problems or utilizing new methods. This document identifies the key areas where this support is critical and provides a strategy for investing in them.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Colors of entangled two-photon absorption

Multiphoton absorption of entangled photons offers ways for obtaining unique information about chemical and biological processes. Measurements with entangled photons may enable sensing biological signatures with high selectivity and at very low light levels to protect against photodamage. In this paper, we present a theoretical and experimental study of the excitation wavelength dependence of the entangled two-photon absorption (ETPA) process in a molecular system, which provides insights into how entanglement affects molecular spectra. We demonstrate that the ETPA excitation spectrum can be different from that of classical TPA as well as that for one-photon resonant absorption (OPA) with photons of doubled frequency. These results are modeled by assuming the ETPA cross-section is governed by a two-photon excited state radiative linewidth rather than by electron-phonon interactions, and this leads to excitation spectra that match the observed results. Further, we find that the two-photon-allowed states with highest TPA and ETPA intensities have high electronic entanglements, with ETPA especially favoring states with the longest radiative lifetimes. These results provide concepts for the development of quantum light–based spectroscopy and microscopy that will lead to much higher efficiency of ETPA sensors and low-intensity detection schemes.

Science & Technology - Other Topics↗