Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Orthogonal Efflux and Permeation Properties of Compounds Leads to the Discovery of New Efflux Pump Inhibitors

Optimization of compound permeation into Gram-negative bacteria is one of the most challenging tasks in the development of antibacterial agents. Two permeability barriers–the passive diffusion barrier of the outer membrane (OM) and active drug efflux–act synergistically to protect cells from the antibacterial action of compounds. In Escherichia coli (E. coli) and relatives, these two barriers sieve compounds based on different physicochemical properties that are defined by their interactions with OM porins and efflux pumps, respectively. In this study, we critically tested the hypothesis that the best substrates and inhibitors of efflux pumps are compounds that can effectively permeate the OM and are available at relatively high concentrations in the periplasm. For this purpose, we filtered a large subset of the ZINC15 database of commercially available compounds for compounds containing a primary amine, a chemical feature known to facilitate the uptake through E. coli general porins. The assembled library was screened by ensemble docking to AcrA, the periplasmic component of the AcrAB-TolC efflux pump, followed by experimental testing of the top predicted binders for antibacterial activities, efflux recognition, and inhibition. In this work, we found that the filtered primary amine library is a rich source of compounds with efflux-inhibiting activities and identified efflux pump inhibitors with novel chemical scaffolds effective against E. coli AcrAB-TolC and efflux pumps of multidrug-resistant clinical isolates of Acinetobacter baumannii. However, primary amines are not required for the recognition of compounds by efflux pumps and their efflux-inhibitory activities.

60 APPLIED LIFE SCIENCES↗

Continental-Scale Geographic Trends in Barometric-Pumping Efficiency Potential: A North American Case Study

Barometric pumping is a gas transport mechanism that has important implications for many applications involving subsurface gas seepage processes. Here, this study provides the first continental-scale analysis of barometric-pumping efficiency potential based on meteorology. We quantified the barometric-pumping efficiency potential at 1,257 locations across the continental US and Canada. The results provide continental-scale geographic dependencies of barometric-pumping efficiency potential, indicating a significant correlation with latitude and a nonlinear dependence on longitude. The analysis also indicates that variability in barometric-pumping efficiency potential decreases with distance from the coast and as elevation increases. Locations far from the coastline are more likely to have upper mid-range potentials, while higher elevation locations are more likely to have low potentials. The highest barometric-pumping efficiency potentials are mostly found around the Gulf of St. Lawrence around 50°N. Locations along the Atlantic coast exhibit large-scale variations in potentials with a clear increasing trend with latitude.

58 GEOSCIENCES↗

In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect

A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz{sup 1/2}, which was mainly dominated by the noise of the magnetic shield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Evaluation of Dual-Opposed Jet Mixer Pump Performance for Slurry Mixing

Million-gallon double-shell tanks at Hanford are used to store transuranic, high-level, and low-level radioactive wastes. These wastes consist of a large volume of salt-laden solution covering a smaller volume of settled sludge primarily containing metal hydroxides. These wastes will be retrieved and processed into immobile waste forms suitable for permanent disposal. Retrieval is an important step in implementing these disposal scenarios. The retrieval concept evaluated is to use submerged dual-nozzle jet mixer pumps with horizontally oriented nozzles located near the tank floor that produce horizontal jets of fluid to mobilize the settled solids. The mixer pumps are oscillated through 180 about a vertical axis so the high velocity fluid jets sweep across the floor of the tank. After the solids are mobilized, the pumps will continue to operate at a reduced flow rate producing lower velocity jets sufficient to maintain the particles in a uniform suspension (concentration uniformity). Several types of waste and tank configurations exist at Hanford. The jet mixer pump systems and operating conditions required to mobilize sludge and maintain slurry uniformity will be a function of the waste type and tank configuration. The focus of this work was to conduct a 1/12-scale experiment to develop an analytical model to relate slurry uniformity to tank and mixer pump configurations, operating conditions, and sludge properties. This experimental study evaluated concentration uniformity in a 1/12-scale experiment varying the Reynolds number (Re), Froude number (Fr), and gravitational settling parameter (Gs) space. Simulant physical properties were chosen to obtain the required Re and Gs where Re and Gs were varied by adjusting the kinematic viscosity and mean particle diameter, respectively. Test conditions were achieved by scaling the jet nozzle exit velocity in a 75-in. diameter tank using a mock-up of a centrally located dual-opposed jet mixer pump located just above the tank floor. Concentration measurements at sampling locations throughout the tank were used to assess the degree of uniformity achieved during each test. Concentration data was obtained using a real time in-situ ultrasonic attenuation probe and post-test analysis of discrete batch samples. The undissolved solids concentration at these locations was analyzed to determine whether the tank contents were uniform (≤ ±10% variation about mean) or nonuniform (> ±10% variation about mean) in concentration. Concentration inhomogeneity was modeled as a function of dimensionless parameters. The parameters that best describe the maximum solids volume fraction that can be suspended were found to be 1) the Fr based on nozzle average discharge velocity and tank contents level and 2) the dimensionless particle size based on nozzle diameter. The dependence on the jet Re does not appear to be statistically significant.

correlation↗

Use of non evaporable getter pumps to ensure long term performances of high quantum efficiency photocathodes

High quantum efficiency photocathodes are routinely used as laser triggered emitters in the advanced high brightness electron sources based on radio frequency guns. The sensitivity of “semiconductor” type photocathodes to vacuum levels and gas composition requires special care during preparation and handling. This paper will discuss the results obtained using a novel pumping approach based on coupling a 20 l s{sup −1} sputter ion getter pump with a CapaciTorr® D100 non evaporable getter (NEG) pump. A pressure of 8⋅10{sup −8} Pa was achieved using only a sputter ion pump after a 6 day bake-out. With the addition of a NEG pump, a pressure of 2⋅10{sup −9} Pa was achieved after a 2 day bake-out. These pressure values were maintained without power due to the ability of the NEG to pump gases by chemical reaction. Long term monitoring of cathodes quantum efficiencies was also carried out at different photon wavelengths for more than two years, showing no degradation of the photoemissive film properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Electromagnetic Pump Analysis Tools (PLM DOC-0005-2188). Final Report

This report provides the broad historical review of EM Pump development and details of MATRIX development under this project. This report summarizes the efforts made to modernize the legacy performance models used in previous EM Pump designs and the improvements made to the analysis tools. This report provides information on Tasks 1, 3, and 4 of the entire project. The research for Task 4 builds upon Task 1: Update EM Pump Databank and Task 3: Modernize the Existing EM Pump Analysis Model, which are summarized within this report. Where research for Task 2: Insulation Materials Development and Evaluation identified parameters applicable to the analysis model with Task 4, the analysis code was updated, and analyses were made for additional materials. The important design variables for the manufacture and operation of an EM Pump that the model improvement can evaluate are: space constraints; voltage capability of insulation system; maximum flux density through iron; flow rate and outlet pressure; efficiency and manufacturability. The development of the next-generation EM Pump analysis tools during this two-year program provides information in three broad areas: Status of analysis model development; Improvements made to older simulations; and Comparison to experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pressure distribution along the AGS vacuum chambers with new types of pump out conduits

The AGS HEBT and ring vacuum system is monitored by the discharge current of the magnet ion pumps, which is proportional to the pressure at the inlet port of these ion pumps. The discharge current is measured and suitably calibrated to indicate the ion pump pressure. In order to calculate the vacuum chamber pressure from the ion pump pressure, a detailed analysis is essential to compute their difference in different scenarios. Such analysis has been carried out numerically in the past for the system with the older type of pump out conduits, and similar analysis using FEM in ANSYS is presented in this paper with the newer type of pump out conduit.

43 PARTICLE ACCELERATORS↗

High Toughness Cermets for Molten Salt Pumps

Concentrated Solar Power plants using nitrate salts used cantilevered pump designs to avoid use of bearings in the 565°C salt; however, this necessitated the use of a sump that added additional cost, complexity, and thermal losses. Sump systems had their own complications, including risk of flooding the sump due to control issues either with level indicators or failures in the control valve responsible for filling the sump. Long-shafted pumps were developed and tested, and they outline the need to develop journal sleeves and bearings for new salt systems. Based on reports, pumps will need to be a vertical single- or multi-stage type, mounted to the roof of the molten salt tanks. Design and service for molten salt pumps above 550°C is relatively limited, and at temperatures up to 750°C there is no available design or service experience. Long-shaft pumps that extend to the bottom of the thermal energy storage tank will require bearing materials that are suitable to the given salt chemistry. Lubricity of proposed salts is unclear and need to be determined, especially for cold-tank pumps that require multi-stages for lifting the salt to the top of the tower. Materials, design, and maintenance are all major unknowns.

14 SOLAR ENERGY↗

Alternative All-Metal Scroll Pump Design

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. There have been development efforts to design an all-metal scroll pump design alternative to the Normetex style. The first generation was fabricated out of machined stainless steel, but the thermal management and increased weight were not ideal. To mitigate the weight, an aluminum version was designed. The tritium holdup on untreated aluminum surfaces can be greater than stainless steel, so the wetted aluminum surfaces were electroless plated in nickel and then electroplated in gold. The development effort outlined in this report details the design of an improved version of the stainless steel version.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Study of optimal sizing for residential sorption heat pump system

Gas-driven sorption heat pumps (GDSHP) show significant potential to reduce primary energy use, associated emissions and energy costs for space heating and domestic hot water production in residential applications. This study considered a bivalent heating system consisting of a sorption heat pump and a condensing boiler, and focuses on the optimal heating capacity of each of these components relative to each other. Two bivalent systems were considered: one based on a solid chemisorption cycle (GDSHPA), and one based on a resorption cycle (GDSHPB). Simulations of year-round space heating loads for two single-family houses, one in New York and the other Minnesota, were carried out and the seasonal gas coefficient of performance (SGCOP) calculated. The sorption heat pump’s design heating capacity as a fraction of the bivalent system’s total heating capacity was varied from 0 to 100%. Results show that SGCOP was effectively constant for sorption heat pump design capacity greater than 41% of the peak bivalent GDSHPA design capacity in Minnesota, and 32% for GDSHPB. In New York, these values were 42% and 34% for GDSHPA and GDSHPB respectively. The payback period was also evaluated based on postulated sorption heat pump component costs. The fastest payback was achieved with sorption heat pump design capacity between 22 and 44%.

42 ENGINEERING↗

Wave-powered water pump for upwelling in aquaculture: Numerical model and ocean test

Wave-powered upwelling can increase the productivity and survivability of several aquaculture species. This enhancement is due to transporting cold, nutrient-rich ocean water, typically found lower in the water column, to the surface. Macroalgaes, like kelp, exhibit increased growth from these altered conditions. The University of New Hampshire’s (UNH) wave-powered water pump (wave pump) is a point absorber wave energy converter (WEC) that uses ocean waves to create relative motion between a spar buoy and a concentric float which drives an internal pump. A numerical model of the wave pump was developed using WEC-Sim to predict device performance in the ocean. Wave pump performance was evaluated during a five day ocean test near Appledore Island in Maine in March 2023, where volumetric flow rate, relative distance between spar and float, and wave conditions were measured. These data were then used for numerical model validation. The ocean deployment recorded the device’s performance in a variety of sea states, with average significant wave heights up to 0.7 m. The ocean test data were compared to the WEC-Sim numerical model of the device with favorable results. Average values of device stroke period, stroke height, and flow rate agreed between the ocean test and model data to within approximately 16 to 22%. Furthermore, the validated numerical model provides a valuable tool for improving the design and developing a commercial-scale, wave-powered water pump for use in aquaculture.

16 TIDAL AND WAVE POWER↗

Contribution of the Two Types of Ekman Pumping Induced Eddy Heat Flux to the Total Vertical Eddy Heat Flux

Based on eddy-rich (0.1° horizontal resolution for ocean) Community Earth System Model simulations, we compute the Ekman pumping induced vertical eddy heat flux using two formulations: the classical and the Stern-Ekman pumping. The two mechanisms yield similar patterns in the eddy-induced vertical heat flux, showing strong upward heat flux in ocean frontal regions such as the western boundary current regions. Using the Gulf Stream Extension region as an example, we estimate (1) the Stern-Ekman pumping induced eddy heat flux is 23% and 12% of the total vertical eddy heat flux at 50 m depth during summer and winter, respectively; (2) the classical Ekman pumping accounts for 82% and 88% of the Stern-Ekman pumping induced eddy heat flux at 50 m during summer and winter, respectively. The second finding indicates eddy current feedback on wind stress is the primary cause for the upward eddy heat flux generated by Ekman pumping.

58 GEOSCIENCES↗

Accurate determination of electronic transport properties of silicon wafers by nonlinear photocarrier radiometry with multiple pump beam sizes

In this paper, photocarrier radiometry (PCR) technique with multiple pump beam sizes is employed to determine simultaneously the electronic transport parameters (the carrier lifetime, the carrier diffusion coefficient, and the front surface recombination velocity) of silicon wafers. By employing the multiple pump beam sizes, the influence of instrumental frequency response on the multi-parameter estimation is totally eliminated. A nonlinear PCR model is developed to interpret the PCR signal. Theoretical simulations are performed to investigate the uncertainties of the estimated parameter values by investigating the dependence of a mean square variance on the corresponding transport parameters and compared to that obtained by the conventional frequency-scan method, in which only the frequency dependences of the PCR amplitude and phase are recorded at single pump beam size. Simulation results show that the proposed multiple-pump-beam-size method can improve significantly the accuracy of the determination of the electronic transport parameters. Comparative experiments with a p-type silicon wafer with resistivity 0.1–0.2 Ω·cm are performed, and the electronic transport properties are determined simultaneously. The estimated uncertainties of the carrier lifetime, diffusion coefficient, and front surface recombination velocity are approximately ±10.7%, ±8.6%, and ±35.4% by the proposed multiple-pump-beam-size method, which is much improved than ±15.9%, ±29.1%, and >±50% by the conventional frequency-scan method. The transport parameters determined by the proposed multiple-pump-beam-size PCR method are in good agreement with that obtained by a steady-state PCR imaging technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗