Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “proof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Future-proofing photovoltaics module reliability through a unifying predictive modeling framework

Solar energy, especially photovoltaics (PV), plays a significant role in the global energy transition required for decarbonization. Technological advancements in increasing efficiencies coupled with cost reductions through economies of scale made PV a cost-competitive energy source set to exceed the milestone of 1 TW globally deployed capacity in 2022. However, ongoing downward price pressure coupled with increasing service life expectations creates tremendous challenges for reliability engineers in ensuring the safe and reliable operation of PV modules and systems over the anticipated service life. Today's reliability research efforts aim for module lifetimes of up to 50 years. Still, our current tools fall short in accurately assessing degradation mechanisms and failure modes over such extended periods. We argue that the well-established PV reliability learning cycle needs to be accelerated to keep up with the rapid technological advancements and high expectations that are put on PV and its role in the global energy transition. In this article, we explore the evolution of the PV reliability learning cycle and highlight the significance that predictive modeling capabilities will have on future PV module reliability. We propose creating a unifying modeling framework - which once established will enable the holistic assessment of PV module reliability, accelerate the PV reliability learning cycle, and bring us closer to quantitative service life predictions of PV modules.

14 SOLAR ENERGY↗

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure 136 Xe gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Q ββ . This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of 22 Na 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the 228 Th decay chain were used to represent the background and the signal in a double beta decay. Furthermore, these data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1% for signal events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Rényi quantum null energy condition: proof for free field theories

The Quantum Null Energy Condition (QNEC) is a lower bound on the stress-energy tensor in quantum field theory that has been proved quite generally. It can equivalently be phrased as a positivity condition on the second null shape derivative of the relative entropy S rel (ρ||σ) of an arbitrary state ρ with respect to the vacuum σ. The relative entropy has a natural one-parameter family generalization, the Sandwiched Rényi divergence S n (ρ||σ), which also measures the distinguishability of two states for arbitrary n &isin; [1/2, ∞). A Rényi QNEC, a positivity condition on the second null shape derivative of S n (ρ||σ), was conjectured in previous work. In this work, we study the Rényi QNEC for free and superrenormalizable field theories in spacetime dimension d > 2 using the technique of null quantization. In the above setting, we prove the Rényi QNEC in the case n > 1 for arbitrary states. We also provide counterexamples to the Rényi QNEC for n < 1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Habemus superstratum! A constructive proof of the existence of superstrata

Here, we construct the first example of a superstratum: a class of smooth horizonless supergravity solutions that are parameterized by arbitrary continuous functions of (at least) two variables and have the same charges as the supersymmetric D1-D5-P black hole. We work in Type IIB string theory on T 4 or K 3 and our solutions involve a subset of fields that can be described by a six-dimensional supergravity with two tensor multiplets. The solutions can thus be constructed using a linear structure, and we give an explicit recipe to start from a superposition of modes specified by an arbitrary function of two variables and impose regularity to obtain the full horizonless solutions in closed form. We also give the precise CFT description of these solutions and show that they are not dual to descendants of chiral primaries. They are thus much more general than all the known solutions whose CFT dual is precisely understood. Hence our construction represents a substantial step toward the ultimate goal of constructing the fully generic superstratum that can account for a finite fraction of the entropy of the three-charge black hole in the regime of parameters where the classical black hole solution exists.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Explicit entropic proofs of irreversibility theorems for holographic RG flows

We revisit the existence of monotonic quantities along renormalization group flows using only the Null Energy Condition and the Ryu-Takayanagi formula for the entanglement entropy of field theories with anti-de Sitter gravity duals. In particular, we consider flows within the same dimension and holographically reprove the c-, F -, and a-theorems in dimensions two, three, and four. We focus on the family of maximally spherical entangling surfaces, define a quasi-constant of motion corresponding to the breaking of conformal invariance, and use a properly defined distance between minimal surfaces to construct a holographic c-function that is monotonic along the flow. We then apply our method to the case of flows across dimensions: there, we reprove the monotonicity of flows from AdS D+1 to AdS 3 and prove the novel case of flows from AdS 5 to AdS 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gallbladder Cryoablation: Proof of Concept in a Swine Model for a Percutaneous Alternative to Cholecystectomy

PurposeTo investigate the feasibility of percutaneous gallbladder cryoablation (GBC) under CT guidance in a swine model with histopathologic correlation.Materials and MethodsInstitutional Animal Care and Use Committee approval was obtained for this study protocol. Five pigs underwent GBC. Under CT guidance, 3–4 cryoprobes were positioned percutaneously at the gallbladder margins. Thermocouple probes were placed percutaneously at the gallbladder fundus, neck, free wall, and gallbladder fossa. Two freeze–thaw cycles ranging from 10 to 26 min were performed. The subjects were sacrificed 5 h after cryoablation. The gallbladder and bile ducts were resected, stained, and examined microscopically.ResultsGBC was completed in all subjects. A 10-mm ablation margin was achieved beyond all gallbladder walls. Thermocouple probes reached at least −20 °C. Intra-procedural body temperature decreased to a minimum of 35 °C but recovered after the procedure. Intra- and post-procedural vital signs otherwise remained within physiologic parameters. Non-target ablation occurred in the stomach and colon of the first two subjects. Histology demonstrated complete denudation of the gallbladder epithelium, hemorrhage, and edema within the muscularis layer, and preservation of the microscopic architecture of the common bile duct in all cases.ConclusionPercutaneous gallbladder cryoablation is feasible, with adequate ablation margins obtained and histologic changes demonstrating transmural necrosis. Adjacent structures included in the ablation may require conservative ablation zones, hydrodissection, or continuous saline lavage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Alcohol and Onyx Mixture for Embolization: Feasibility and Proof of Concept in Both In Vitro and In Vivo Models

IntroductionOnyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of this study is to evaluate the injectability, radiopacity, and mechanical and occlusive properties of different mixtures of Onyx 18 and ethanol in vitro and in vivo (in a swine model).Materials and MethodsVarious Onyx 18 and ethanol formulations were prepared and tested in vitro for their injectability, solidification rate and shrinkage, cohesion and occlusive properties. In vivo tests were performed using 3 swine. Ease of injection, radiopacity, cohesiveness and penetration were analyzed using fluoroscopy and high-resolution CT.ResultsAll mixtures were easy to inject through a microcatheter with no resistance or blockage in vitro and in vivo. The 50%-ethanol mixture showed delayed copolymerization with fragmentation and proximal occlusion. The 75%-ethanol mixture showed poor radiopacity in vivo and was not tested in vitro. The 25%-ethanol mixture showed good occlusive properties and accepted penetration and radiopacity.ConclusionMixing Onyx and ethanol is feasible. The mixture of 25% of ethanol and 75% of Onyx 18 could be a new sclero-embolic agent. Further research is needed to study the chemical changes of the mixture, to confirm the significance of the added sclerotic effect and to find out the ideal mixture percentages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional fracture continuum characterization aided by surface time-domain electromagnetics and hydrogeophysical joint inversion—proof-of-concept

Efficient and safe production of hydraulically fractured reservoirs benefits from the prediction of their geometrical attributes. Geophysical methods have the potential to provide data that are sensitive to fracture geometries, alleviating the typically sparse nature of in situ reservoir observations. Moreover, surface-based methods can be logistically and economically attractive since they avoid operational interference with the injection well infrastructure. Here, we investigate the potential of the surface-based time-domain electromagnetic (EM) method. EM methods can play an important role owing to their sensitivity to injection-induced fluid property changes. Two other advantageous factors are the EM signal-enhancing effect of vertical steel-cased wells and the fact that injected proppants can be enhanced to produce a stronger electrical conductivity contrast with the reservoir’s connate fluid. Nevertheless, an optimal fracture characterization will no doubt require the integration of EM and reservoir injection and production data. We hence carry out our investigations within a hydrogeophysical parameter estimation framework where EM data and injection flow rates are combined in a fully coupled way. Given the interdisciplinary nature of coupled hydrogeophysical inverse modeling, we dedicate one section to laying out key aspects in a didactic manner.

58 GEOSCIENCES↗

Thermal Wear Sensing System: Proof of the Concept

A technique for wear sensing using a sacrificial layer with specific material properties has been developed successfully. This is achieved by recording the temperature evolution underneath the sacrificial organic layer during sliding tests, and by correlating the recorded temperature with a wear depth. Finite element modeling was used to calculate the contact temperature which spreads through the sacrificial layer under different sliding test conditions. Numerical simulation was used to determine the optimal parameters for the best correlation between temperature and wear depth. These parameters were used to select the appropriate sacrificial layer for wear sensing. Thus, an epoxy layer was implemented and experimental measurements were carried out to check the correlation between the measured temperature underneath the epoxy layer and wear depth. It was found that a low thermal conductivity of the sacrificial layer of less than 1 W/m K and a relative high thermal conductivity of the substrate, namely more than 4 W/m K are the optimal parameters for our thermal wear sensing system. The thickness of the sacrificial layer is also a crucial parameter and has to be taken into account when designing such a sensing system.

36 MATERIALS SCIENCE↗

Large-scale production of 88 Y and 88 Zr/ 88 Y generators: A proof of concept study for a 70 MeV H – cyclotron

Here, the large-scale production of 88 Y with proton-induced reactions has been investigated from the perspective of new generation 70 MeV H – cyclotrons. Tandem target configurations are presented for both the direct production of 88 Y as well as for producing 88 Zr/ 88 Y generators. Based on the relevant excitation functions, physical yields have been derived for 88 Y production with Y 2 O 3 /SrCO 3 tandem targets and 88 Zr production with Zr/Y 2 O 3 tandem targets. Yields are presented for optimized targets (i.e. optimum yield) as well as for balanced thermal loads on the individual targets. Liquid 88 Zr/ 88 Y generators have been produced using both natural Zr and Nb target materials, the former for dedicated productions and the latter as a byproduct by processing spent irradiated Nb capsules which normally would constitute radioactive waste. These stock solutions, which contain both the target material and 88 Zr precursor, are retained virtually unchanged after processing except for the removal of 88 Y on AG MP-50 macroporous cation-exchange resin. Methods are presented for the preparation of Nb stock solutions in hydrofluoric acid and Zr stock solutions in sulfuric acid. It is shown that multi-Ci productions of 88 Y are feasible at a 70 MeV cyclotron facility, suitable for the needs of fracking applications. In addition, 88 Zr/ 88 Y generators can provide 88 Y with very high specific activity, suitable for labelling of biomolecules.

07 ISOTOPE AND RADIATION SOURCES↗

Preliminary investigation of 48 V-labeled VO(acac) 2 for cancer imaging: An initial proof-of-concept study

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48 V, chelation as 48 VO(acac) 2 , and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of nat Ti (p,n) 48 V. The radioisotope production rate was 4.84 ± 0.67 μCi/μA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48 VO(acac) 2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac) 2 , verifying the successful synthesis of 8VO(acac) 2 . In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proof-of-concept studies of novel protocols for producing highly pure 48 V from a 48 Cr/ 48 V generator

Here, the quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. 48 V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce 48 V with high enough isotopic purity for some of these measurements. “Isotope harvesting” at the Facility for Rare Isotope Beams (FRIB) is a new isotope production technique that could potentially yield 48 V with the necessary purity for such studies. In this case, 48Cr would be collected and allowed to generate 48 V that can be separated from undecayed 48 Cr to yield highly pure 48 V. Thus, any protocol for producing pure 48 V via isotope harvesting would involve utilizing a separation technique that can effectively separate 48 Cr and 48 V. In this study, the radiotracers 51 Cr and 48 V were used to develop possible radiochemical separation methodologies, which can be translated to obtain high purity 48 V via this novel isotope production method. The developed protocols utilize either ion exchange or extraction chromatographic resins. Separations of 51 Cr and 48 V with AG 1-X8 anion exchange resin respectively resulted in recoveries of 95.6(26)% and 96.2(12)% with radionuclidic purities of 92(2)% and 99(1)%. An even more effective Cr and V separation was obtained with an extraction chromatographic resin (TRU resin) and 10 M HNO 3 loading solution. Here, 51 Cr and 48 V respectively had recoveries of 94.1(28)% and 96.2(13)% with high radionuclidic purities (100(2)% and 100(1)%) in small volumes (8.81(8) mL and 5.39(16) mL). This study suggests that, to maximize the yield and isotopic purity of 48 V, the best production protocol would involve utilizing two separations with TRU resin and 10 M HNO 3 to isolate 48 Cr and purify the generated 48 V.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The NDUFB6 subunit of the mitochondrial respiratory chain complex I is required for electron transfer activity: A proof of principle study on stable and controlled RNA interference in human cell lines

Highlights: {yields} NDUFB6 is required for activity of mitochondrial complex I in human cell lines. {yields} Lentivirus based RNA interference results in frequent off target insertions. {yields} Flp-In recombinase mediated miRNA insertion allows gene-specific extinction. -- Abstract: Molecular bases of inherited deficiencies of mitochondrial respiratory chain complex I are still unknown in a high proportion of patients. Among 45 subunits making up this large complex, more than half has unknown function(s). Understanding the function of these subunits would contribute to our knowledge on mitochondrial physiology but might also reveal that some of these subunits are not required for the catalytic activity of the complex. A direct consequence of this finding would be the reduction of the number of candidate genes to be sequenced in patients with decreased complex I activity. In this study, we tested two different methods to stably extinct complex I subunits in cultured cells. We first found that lentivirus-mediated shRNA expression frequently resulted in the unpredicted extinction of additional gene(s) beside targeted ones. This can be ascribed to uncontrolled genetic material insertions in the genome of the host cell. This approach thus appeared inappropriate to study unknown functions of a gene. Next, we found it possible to specifically extinct a CI subunit gene by direct insertion of a miR targeting CI subunits in a Flp site (HEK293 Flp-In cells). By using this strategy we unambiguously demonstrated that the NDUFB6 subunit is required for complex I activity, and defined conditions suitable to undertake a systematic and stable extinction of the different supernumerary subunits in human cells.

60 APPLIED LIFE SCIENCES↗