Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

On-Site Pilot Study - Removal of Uranium, Radium-226 and Arsenic from Impacted Leachate by Reverse Osmosis - 13155

Conestoga-Rovers and Associates (CRA-LTD) performed an on-site pilot study at the Welcome Waste Management Facility in Port Hope, Ontario, Canada, to evaluate the effectiveness of a unique leachate treatment process for the removal of radioactive contaminants from leachate impacted by low-level radioactive waste. Results from the study also provided the parameters needed for the design of the CRA-LTD full scale leachate treatment process design. The final effluent water quality discharged from the process to meet the local surface water discharge criteria. A statistical software package was utilized to obtain the analysis of variance (ANOVA) for the results from design of experiment applied to determine the effect of the evaluated factors on the measured responses. The factors considered in the study were: percent of reverse osmosis permeate water recovery, influent coagulant dosage, and influent total dissolved solids (TDS) dosage. The measured responses evaluated were: operating time, average specific flux, and rejection of radioactive contaminants along with other elements. The ANOVA for the design of experiment results revealed that the operating time is affected by the percent water recovery to be achieved and the flocculant dosage over the range studied. The average specific flux and rejection for the radioactive contaminants were not affected by the factors evaluated over the range studied. The 3 month long on-site pilot testing on the impacted leachate revealed that the CRA-LTD leachate treatment process was robust and produced an effluent water quality that met the surface water discharge criteria mandated by the Canadian Nuclear Safety Commission and the local municipality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of Data Management in a Long-term Biological Monitoring Program

The long-term Biological Monitoring and Abatement Program (BMAP) has always needed to collect and retain high-quality data on which to base its assessments of ecological status of streams and their recovery after remediation. Its formal quality assurance, data processing, and data management components all contribute to this need. The Quality Assurance Program comprehensively addresses requirements from various institutions, funders, and regulators, and includes a data management component. Centralized data management began a few years into the program. An existing relational database was adapted and extended to handle biological data. Data modeling enabled the program's database to process, store, and retrieve its data. The data base's main data tables and several key reference tables are described. One of the most important related activities supporting long-term analyses was the establishing of standards for sampling site names, taxonomic identification, flagging, and other components. There are limitations. Some types of program data were not easily accommodated in the central systems, and many possible data-sharing and integration options are not easily accessible to investigators. The implemented relational database supports the transmittal of data to the Oak Ridge Environmental Information System (OREIS) as the permanent repository. From our experience we offer data management advice to other biologically oriented long-term environmental sampling and analysis programs.

54 ENVIRONMENTAL SCIENCES↗

Design and Operation of a Multi-Bed Catalytic Micro-Reactor for the Study of Co-Processing of Bio-Oils with VGO

An industry wide shift from fossil-based fuel to renewable fuel sources including biomass, municipal waste, and plastics will require new process monitoring methods to minimize transitional risks including off specification product formation and catalyst deactivation. This project aims to provide a machine learning based process monitoring tool composed of online, slipstream mass spectra for use in biomass refineries and co-processing in existing refineries allowing operators to monitor product qualities and adjust process conditions accordingly. In order to maximize the robustness of the tool, large volumes of data must be collected to fine tune model parameters which consists of both micro and pilot scale mass spectral data. Micro-scale data is collected with a multi-tube micro-reactor housing up to six catalysts in horizontal beds, coupled with a molecular beam mass spectrometer. A pyrolizer equipped with an auto-sampler streamlines the micro-scale data collection process. This type of pyrolizer/micro-reactor configuration does not exist on the market, and therefore had to be created for the purposes of this project. The design and commissioning of this reactor will be presented in detail. This reactor set-up is highly flexible and increases throughput of analysis. For catalyst testing, each bed can be individually selected simply by turning valves. For catalyst reduction and regeneration, simultaneous flow through all six beds is used. The reproducibility of the system was first assessed with whole biomass pyrolysis along with pyrolysis of calibration standards. Initial work on this system evaluated two FCC catalysts, equilibrium catalyst (E-cat), and a proprietary catalyst from Johnson Matthey specifically design for co-processing of bio-oil with vacuum gas oil (VGO). This work used model compounds and VGO which illuminated differences in products produced by the catalysts.

biomass↗

An Overview of ARM Program Climate Research Facility Data Quality Assurance

This report documents key aspects of the Atmospheric Radiation Measurement (ARM) Program's data quality assurance program. Processes described include data archival, display, and distribution, data stream reprocessing, and future directions in ARM data quality checking. A comprehensive, end-to-end data quality assurance program, from instrument siting, to calibration and maintenance, through data quality control and well-documented dissemination, is essential for producing a high-quality research data set. The processes developed over the past 15 years by the ARM Program offer a possible framework for use by other instrumentation-diverse networks, and are offered here to highlight the myriad aspects that go into producing such a data set.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Secure environment establishment for FPGA-based safety-critical systems: quality management system context - 159

The paper discusses importance of secure development and operational environment establishment process, its particular stages, including security-oriented analysis and assessment of safety-critical instrumentation and control (I and C) systems. Two particular aspects are covered - security assessment and security assurance related to processes established by Quality Management System (QMS). One of the underlying ideas for the security assessment approach is in performance of gap analysis. Such analysis considers influence of all different factors within I and C system development process, and further application of Intrusion Modes and Effect Criticality Analysis (IMECA) technique. It makes the approach applicable to various safety-critical systems, considering underlying technologies (for example, Field-Programmable Gate Arrays (FPGA). Nowadays FPGA technology is often used in wide spectrum of hardware devices - from personal devices to complex I and C systems for Nuclear Power Plants (NPPs). The problem of cyber security assessment and assurance for FPGA technology in general and its application in safety-critical I and C systems in particular is not completely solved due to several reasons that cover regulations, QMS processes, implementation of development and verification activities, etc. The paper overviews existing regulations, which cover various aspects of NPP I and C systems development and operation, FPGA technology implementation, and secure development and operational environment establishment and assurance. The paper also emphasizes that complex approach should be used to identify and mitigate all specific vulnerabilities thorough the whole life cycle on the basis on Intrusion Modes, Effect and Criticality Analysis technique. The paper also proposes approach to the development of safety-critical I and C systems in the scope of cyber security assurance process at developer site. Secure development environment is described as a key factor during the development process and the paper also discusses establishment and maintenance of such environment as a part of company's Nuclear Quality Assurance's QMS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TU-FG-201-05: Varian MPC as a Statistical Process Control Tool

Purpose: Quality assurance in radiotherapy requires the measurement of various machine parameters to ensure they remain within permitted values over time. In Truebeam release 2.0 the Machine Performance Check (MPC) was released allowing beam output and machine axis movements to be assessed in a single test. We aim to evaluate the Varian Machine Performance Check (MPC) as a tool for Statistical Process Control (SPC). Methods: Varian’s MPC tool was used on three Truebeam and one EDGE linac for a period of approximately one year. MPC was commissioned against independent systems. After this period the data were reviewed to determine whether or not the MPC was useful as a process control tool. Analyses on individual tests were analysed using Shewhart control plots, using Matlab for analysis. Principal component analysis was used to determine if a multivariate model was of any benefit in analysing the data. Results: Control charts were found to be useful to detect beam output changes, worn T-nuts and jaw calibration issues. Upper and lower control limits were defined at the 95% level. Multivariate SPC was performed using Principal Component Analysis. We found little evidence of clustering beyond that which might be naively expected such as beam uniformity and beam output. Whilst this makes multivariate analysis of little use it suggests that each test is giving independent information. Conclusion: The variety of independent parameters tested in MPC makes it a sensitive tool for routine machine QA. We have determined that using control charts in our QA programme would rapidly detect changes in machine performance. The use of control charts allows large quantities of tests to be performed on all linacs without visual inspection of all results. The use of control limits alerts users when data are inconsistent with previous measurements before they become out of specification. A. Carver has received a speaker’s honorarium from Varian.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking checklist item in the pre-treatment plan check assessment; the ramification of which will be assessed in future data.

60 APPLIED LIFE SCIENCES↗

DM100 and DM1200 Melter Testing with High Waste Loading Glass Formulations for Hanford High-Aluminum HLW Streams (Test Plan)

This Test Plan describes work to support the development and testing of high waste loading glass formulations that achieve high glass melting rates for Hanford high aluminum high level waste (HLW). In particular, the present testing is designed to evaluate the effect of using low activity waste (LAW) waste streams as a source of sodium in place of chemical additives, sugar or cellulose as a reductant, boehmite as an aluminum source, and further enhancements to waste processing rate while meeting all processing and product quality requirements. The work will include preparation and characterization of crucible melts in support of subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass formulations, glass processing temperature, incorporation of the LAW waste stream as a sodium source, type of organic reductant, and feed solids content on waste processing rate and product quality. Also included is a confirmatory test on the HLW Pilot Melter (DM1200) with a composition selected from those tested on the DM100. This work builds on previous work performed at the Vitreous State Laboratory (VSL) for Department of Energy’s (DOE’s) Office of River Protection (ORP) to increase waste loading and processing rates for high-iron HLW waste streams as well as previous tests conducted for ORP on the same waste composition. This Test Plan is prepared in response to an ORP-supplied statement of work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Temperature controlled friction extrusion process

Processing temperature is decisive to the properties and performance of the product in friction extrusion. However, the constantly varying thermal boundary conditions result in an unstable processing temperature even fixed die rotational speed and feed rate were implemented, which extensively disturb the stability of the process and the quality of the product. It is key to maintain the process temperature to ensure the properties of the product is uniform. What's more, a controlled processing temperature enables the properties of the product to be manipulatable between parts and between different locations of one part

Li, Xiao↗

Development of quantum dot materials for infrared cameras (Final CRADA Report)

The aim of this project was to develop scalable methods to produce infrared (IR) mercury telluride (HgTe) colloidal quantum dot (CQD) thin films and demonstrate their utility in a proof-of-concept monolithic SWIR focal plane array (FPA). These objectives were accomplished by scaling up the HgTe CQD synthesis, characterizing physical and electrical properties of HgTe CQDs, evaluating solution-processed coating methods for quality and efficiency, and developing a process flow to integrate HgTe CQDs with commercial-off-the-shelf silicon CMOS readout circuits by solution-processed coating to produce monolithic FPAs. The FPA is the image sensor in an infrared imaging system responsible for detecting and processing reflected or emitted light into an infrared image of the scene under observation. The quality of the image is determined by the sensitivity and resolution of the image sensor in the system. Higher resolution IR FPAs enable higher throughput in manufacturing quality assurance, wider field of view for autonomous navigation, and longer range surveillance for defense.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SLURRY MIX EVAPORATOR BATCH ACCEPTABILITY AND TEST CASES OF THE PRODUCT COMPOSITION CONTROL SYSTEM WITH THORIUM AS A REPORTABLE ELEMENT

The Defense Waste Processing Facility (DWPF), which is operated by Savannah River Remediation, LLC (SRR), has recently begun processing Sludge Batch 6 (SB6) by combining it with Frit 418 at a nominal waste loading (WL) of 36%. A unique feature of the SB6/Frit 418 glass system, as compared to the previous glass systems processed in DWPF, is that thorium will be a reportable element (i.e., concentrations of elemental thorium in the final glass product greater than 0.5 weight percent (wt%)) for the resulting wasteform. Several activities were initiated based upon this unique aspect of SB6. One of these was an investigation into the impact of thorium on the models utilized in DWPF's Product Composition and Control System (PCCS). While the PCCS is described in more detail below, for now note that it is utilized by Waste Solidification Engineering (WSE) to evaluate the acceptability of each batch of material in the Slurry Mix Evaporator (SME) before this material is passed on to the melter. The evaluation employs models that predict properties associated with processability and product quality from the composition of vitrified samples of the SME material. The investigation of the impact of thorium on these models was conducted by Peeler and Edwards [1] and led to a recommendation that DWPF can process the SB6/Frit 418 glass system with ThO{sub 2} concentrations up to 1.8 wt% in glass. Questions also arose regarding the handling of thorium in the SME batch acceptability process as documented by Brown, Postles, and Edwards [2]. Specifically, that document is the technical bases of PCCS, and while Peeler and Edwards confirmed the reliability of the models, there is a need to confirm that the current implementation of DWPF's PCCS appropriately handles thorium as a reportable element. Realization of this need led to a Technical Task Request (TTR) prepared by Bricker [3] that identified some specific SME-related activities that the Savannah River National Laboratory (SRNL) was requested to conduct. SRNL issued a Task Technical and Quality Assurance (TT&QA) plan [4] in response to the SRR request. The conclusions provided in this report are that no changes need to be made to the SME acceptability process (i.e., no modifications to WSRC-TR-95-00364, Revision 5, are needed) and no changes need to be made to the Product Composition Control System (PCCS) itself (i.e. the spreadsheet utilized by Waste Solidification Engineering (WSE) for acceptability decisions does not require modification) in response to thorium becoming a reportable element for DWPF operations. In addition, the inputs and results for the two test cases requested by WSE for use in confirming the successful activation of thorium as a reportable element for DWPF operations during the processing of SB6 are presented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Level Waste Vitrification System Improvements (Final Report)

This report describes work conducted to support the development and testing of new glass formulations that extend beyond those that have been previously investigated for the Hanford Waste Treatment and Immobilization Plant (WTP). The principal objective was to investigate maximization of the incorporation of several waste components that are expected to limit waste loading and, consequently, high level waste (HLW) processing rates and canister count. The work was performed with four waste compositions specified by the Office of River Protection (ORP); these wastes contain high concentrations of bismuth, chromium, aluminum, and aluminum plus sodium. The tests were designed to identify glass formulations that maximize waste loading while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts in support of subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass formulations, increased glass processing temperature, increased crystallinity, and feed solids content on waste processing rate and product quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating field observations and process-based modeling to predict watershed water quality under environmental perturbations

Watersheds play a critical role in supplying water resources needed for human use and ecosystem health. Understanding and predicting how, when, and where changes in the quantity and quality of water resources occur under different environmental stresses including extreme events is crucial for sustainable management of water resources under a changing environment. However, few studies have attempted to quantify or identify the factors and process interactions controlling the impact of extreme events across water-shed systems. Only few large-scale studies include coordinated monitoring and modeling efforts, which limits our ability to assess the large-scale impact of extreme events on water supply and quality. Methods are lacking to propagate uncertainty in process understanding through an integrated hydro-biogeochemical model framework and evaluate its importance, thus failing to take full advantage of the information potentially available through transformative advances in characterization technologies from high-resolution mass spectrometry to airborne and satellite-based remote sensing. There are consequent risks to our nations water security and to human and ecosystem health that may become exacerbated with the increasing frequency of extreme events that is projected for the coming decades. This paper reviews the current status of watershed science for both water quantity and quality and identifies critical gaps in our current knowledge and modeling capability in addressing the emergent needs in predicting watershed hydrologic and biogeochemical responses (i.e., water quantity and quality) under natural and anthropogenic perturbations. We highlight the need to (1) understand how environmental perturbations including extreme events like floods and droughts propagate through watershed systems and assess their short- and long-term impacts on watershed biogeochemistry, water quality and their recovery pathways; (2) develop and improve a watershed water quality model that reflects the state of scientific understanding gained from observations; and (3) construct a data-model fusion system for watershed characterization, process identification, and mechanistic model parameterization. A large base of modeling, monitoring and data capabilities have been built by various federal government agencies given the relevance of water to their critical missions. An emerging need is to build an integrated national capability for watershed water availability and quality that can address water-related missions across multiple federal agencies.

13 HYDRO ENERGY↗

Messiah College Biodiesel Fuel Generation Project (Final Technical Report)

Many obvious and significant concerns arise when considering the concept of small-scale biodiesel production. Does the fuel produced meet the stringent requirements set by the commercial biodiesel industry? Is the process safe? How are small-scale producers collecting and transporting waste vegetable oil? How is waste from the biodiesel production process handled by small-scale producers? These concerns and many others were the focus of the research preformed in the Messiah College Biodiesel Fuel Generation project over the last three years. This project was a unique research program in which undergraduate engineering students at Messiah College set out to research the feasibility of small-biodiesel production for application on a campus of approximately 3000 students. This Department of Energy (DOE) funded research program developed out of almost a decade of small-scale biodiesel research and development work performed by students at Messiah College. Over the course of the last three years the research team focused on four key areas related to small-scale biodiesel production: Quality Testing and Assurance, Process and Processor Research, Process and Processor Development, and Community Education. The objectives for the Messiah College Biodiesel Fuel Generation Project included the following: 1. Preparing a laboratory facility for the development and optimization of processors and processes, ASTM quality assurance, and performance testing of biodiesel fuels. 2. Developing scalable processor and process designs suitable for ASTM certifiable small-scale biodiesel production, with the goals of cost reduction and increased quality. 3. Conduct research into biodiesel process improvement and cost optimization using various biodiesel feedstocks and production ingredients.

09 BIOMASS FUELS↗

WE-G-209-00: Identifying Image Artifacts, Their Causes, and How to Fix Them

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗

WE-G-209-01: Digital Radiography

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗

WE-G-209-02: CT

Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

60 APPLIED LIFE SCIENCES↗