Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “picosecond”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Epitaxial growth and picosecond carrier dynamics of GaInAs/GaInNAs superlattices

We study GaInAs/GaInNAs superlattice structures grown on InP substrate as potential candidates for photoconductive terahertz devices or saturable absorbers working at 1.55 {mu}m wavelength. The N-rich GaInNAs layers are flat, with no three-dimensional islanding, and act as trapping layers where carriers can recombine rapidly. The carrier lifetime in GaInAs/GaInNAs superlattice was measured for various growth parameters using time-resolved differential transmission experiments at 1.55 {mu}m wavelength. The carrier lifetime is found to depend strongly on N content and can be reduced down to 3.8 ps for samples with 14% of N. The mechanisms involved in the capture process of photocarriers are discussed.

36 MATERIALS SCIENCE↗

Focusing of millijoule picosecond K{sub a}lpha radiation from 100 TW laser-solid interaction

A calibrated x-ray spectrometer was used to characterize an intense 4.5 keV K{sub a}lpha source. Generated from the interaction of 30 J-320 fs laser pulses focused on 25 mum thick Ti foils, the conversion efficiency into Ti K{sub a}lpha line is estimated to (9+-6)x10{sup -5}. Highly efficient collection, monochromatization and focusing were achieved using an ellipsoidally bent highly oriented pyrolytic graphite crystal. The measured 700 mum full width half maximum (FWHM) focal spot leads to a fluence of (3.0+-2.1) mJ/cm{sup 2} hence paving the way to the study of intense x-ray pulse interaction with matter as demonstrated by a first simple experiment.

36 MATERIALS SCIENCE↗

Subcritical microwave coupling to femtosecond and picosecond laser ionization for localized, multipoint ignition of methane/air mixtures

Ignition in methane/air mixtures has been achieved using low energy seed laser pulses and an overlapping subcritical microwave pulse. It is shown that the extremely weak ionization of the laser localizes the microwave energy deposition--leading to rapid heating, high temperatures, and ignition. Multiple simultaneous localized regions of ignition are also achieved using the same microwave pulse. Interactions of the seed laser pulse and microwave heating pulse were observed using schlieren and shadowgraph to record the intensity of heating, the scale of the interaction, and for confirmation of ignition. In addition, a coupled one-dimensional gasdynamic-plasma dynamic model has been developed to follow the rapidly evolving plasma properties and the gas properties achieved through this interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Picosecond carrier lifetimes in dilute GaInNAs grown on InP substrate

We study the carrier relaxation dynamics in Ga{sub 1-y}In{sub y} N{sub 0.03}As{sub 0.97} layers grown on InP substrate by molecular beam epitaxy. This dilute nitride semiconductor is a potential candidate for ultrafast components such as photoconductive terahertz devices driven at 1.55 {mu}m wavelength. Carrier lifetimes are measured by pump-probe experiments at 1550 nm wavelength and the shortest carrier lifetime is 2.6 ps under photoexcitation with {approx}4.2 {mu}J/cm{sup 2}. We observe two contributions in the differential transmittance decay. These contributions are discussed in terms of photocarrier recombination processes.

36 MATERIALS SCIENCE↗

Note: Recent achievements at the 60-MeV Linac for sub-picosecond terahertz radiation at the Pohang Accelerator Laboratory

A femtosecond (fs) terahertz (THz) linac has been constructed to generate fs-THz radiation by using ultrashort electron beam at the Pohang Accelerator Laboratory. To generate an ultrashort electron beam with 60-MeV energy, a chicane bunch compressor has been adopted. Simulation studies have been conducted to design the linac. In this note, recent achievements at 60-MeV linac are presented.

43 PARTICLE ACCELERATORS↗

X-ray bang-time and fusion reaction history at picosecond resolution using RadOptic detection

We report recent progress in the development of RadOptic detectors, radiation to optical converters, that rely upon x-ray absorption induced modulation of the optical refractive index of a semiconductor sensor medium to amplitude modulate an optical probe beam. The sensor temporal response is determined by the dynamics of the electron-hole pair creation and subsequent relaxation in the sensor medium. Response times of a few ps have been demonstrated in a series of experiments conducted at the LLNL Jupiter Laser Facility (JLF). This technology will enable x-ray bang-time and fusion burn-history measurements with {approx} ps resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond laser structuring of thin film platinum layers covered with tantalum pentoxide isolation

A thin film layer system consisting of platinum (Pt) as conductive layer on a glass substrate and tantalum pentoxide as isolating layer on top of the platinum is attractive for designing biocompatible conductor paths and contact pads for bio sensor chips. For the flexible and rapid patterning of the conductive and the isolating layers, both, the complete removal and the selective ablation of the individual thin films were investigated using ultra-short laser pulses with about 10 ps pulse duration and 1064 nm wavelength at low laser fluences. A platinum film covered with tantalum pentoxide shows a significantly lower ablation threshold than a single Pt film on glass alone when illuminated from the front side. Furthermore, we explored that the tantalum pentoxide film can be removed by glass side illumination from the Pt film, without affecting the Pt film and leaving the Pt film on the glass substrate intact. Those ablation phenomena occur at laser fluences of about 0.2 J/cm{sup 2}, far below the evaporation limit of platinum. We present a detailed ablation threshold value examination for the structuring of these layer systems by front side and glass side irradiation for different film thicknesses. Furthermore, we discuss the possible underlying physical mechanisms of these ablation phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast electron propagation in Ti foils irradiated with sub-picosecond laser pulses at Iλ{sup 2}>10{sup 18} Wcm{sup −2}μm{sup 2}

We have studied the propagation of fast electrons through laser irradiated Ti foils by monitoring the emission of hard X-rays and K-α radiation from bare foils and foils backed by a thick epoxy layer. Key observations include strong refluxing of electrons and divergence of the electron beam in the foil with evidence of magnetic field collimation. Our diagnostics have allowed us to estimate the fast electron temperature and fraction of laser energy converted to fast electrons. We have observed clear differences between the fast electron temperatures observed with bare and epoxy backed targets which may be due to the effects of refluxing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous investigation of ultrafast structural dynamics and transient electric field by sub-picosecond electron pulses

The ultrafast structure dynamics and surface transient electric field, which are concurrently induced by laser excited electrons of an aluminum nanofilm, have been investigated simultaneously by the same transmission electron diffraction patterns. These two processes are found to be significantly different and distinguishable by tracing the time dependent changes of electron diffraction and deflection angles, respectively. This study also provides a practical means to evaluate simultaneously the effect of transient electric field during the study of structural dynamics under low pump fluence by transmission ultrafast electron diffraction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Picosecond dynamics of a silicon donor based terahertz detector device

We report the characteristics of a simple complementary metal-oxide-semiconductor compatible terahertz detector device with low response time (nanoseconds) determined using a short-pulse, high intensity free-electron laser. The noise equivalent power was 1 × 10{sup −11} W Hz{sup −1/2}. The detector has an enhanced response over narrow bands, most notably at 9.5 THz, with a continuum response at higher frequencies. Using such a device, the dynamics of donors in silicon can be explored, a system which has great potential for quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopy and picosecond dynamics of aqueous NO{sub 2}

We investigate the formation of aqueous nitrogen dioxide, NO{sub 2} formed through femtosecond photolysis of nitrate, NO{sub 3}{sup −}(aq) and nitromethane CH{sub 3}NO{sub 2}(aq). Common to the experiments is the observation of a strong induced absorption at 1610 ± 10 cm{sup −1}, assigned to the asymmetric stretch vibration in the ground state of NO{sub 2}. This assignment is substantiated through isotope experiments substituting {sup 14}N by {sup 15}N, experiments at different pH values, and by theoretical calculations and simulations of NO{sub 2}–D{sub 2}O clusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Very low electron temperature in warm dense matter formed by focused picosecond soft x-ray laser pulses

We investigated the optical emission from the ablating surfaces induced by the irradiations of soft x-ray laser (SXRL) pulses with the aim of estimation of the maximum electron temperature. No emission signal in the spectral range of 400–800 nm could be observed despite the formation of damage structures on the target surfaces. Hence, we estimated an upper limit for the electron temperature of 0.4–0.7 eV for the process duration of 100–1000 ps. Our results imply that the ablation and/or surface modification by the SXRL is not accompanied by plasma formation but is induced by thermo-mechanical pressure, which is so called a spallative ablation. This spallative ablation process occurs in the low electron temperature region of a non-equilibrium state of warm dense matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Picosecond solvation dynamics—A potential viewer of DMSO—Water binary mixtures

In this work, we have investigated the composition dependent anomalous behavior of dimethyl sulfoxide (DMSO)-water binary mixture by collecting the ultrafast solvent relaxation response around a well known solvation probe Coumarin 480 (C480) by using a femtosecond fluorescence up-conversion spectrometer. Recent molecular dynamics simulations have predicted two anomalous regions of DMSO-water binary mixture. Particularly, these studies encourage us to investigate the anomalies from experimental background. DMSO-water binary mixture has repeatedly given evidences of its dual anomalous nature in front of our systematic investigation through steady-state and time-resolved measurements. We have calculated average solvation times of C480 by two individual well-known methods, among them first one is spectral-reconstruction method and another one is single-wavelength measurement method. The results of both the methods roughly indicate that solvation time of C480 reaches maxima in the mole fraction of DMSO X{sub D} = 0.12–0.17 and X{sub D} = 0.27–0.35, respectively. Among them, the second region (X{sub D} = 0.27–0.35) is very common as most of the thermodynamic properties exhibit deviation in this range. Most probably, the anomalous solvation trend in this region is fully guided by the shear viscosity of the medium. However, the first region is the most interesting one. In this region due to formation of strongly hydrogen bonded 1DMSO:2H{sub 2}O complexes, hydration around the probe C480 decreases, as a result of which solvation time increases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum space charge effects in sub-picosecond soft X-ray photoemission on a molecular adsorbate layer

Vacuum space charge-induced kinetic energy shifts of O 1s and Ru 3d core levels in femtosecond soft X-ray photoemission spectra (PES) have been studied at a free electron laser (FEL) for an oxygen layer on Ru(0001). We fully reproduced the measurements by simulating the in-vacuum expansion of the photoelectrons and demonstrate the space charge contribution of the high-order harmonics in the FEL beam. Employing the same analysis for 400 nm pump-X-ray probe PES, we can disentangle the delay dependent Ru 3d energy shifts into effects induced by space charge and by lattice heating from the femtosecond pump pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hydration-dependent dynamics of human telomeric oligonucleotides in the picosecond timescale: A neutron scattering study

The dynamics of the human oligonucleotide AG{sub 3}(T{sub 2}AG{sub 3}){sub 3} has been investigated by incoherent neutron scattering in the sub-nanosecond timescale. A hydration-dependent dynamical activation of thermal fluctuations in weakly hydrated samples was found, similar to that of protein powders. The amplitudes of such thermal fluctuations were evaluated in two different exchanged wave-vector ranges, so as to single out the different contributions from intra- and inter-nucleotide dynamics. The activation energy was calculated from the temperature-dependent characteristic times of the corresponding dynamical processes. The trends of both amplitudes and activation energies support a picture where oligonucleotides possess a larger conformational flexibility than long DNA sequences. This additional flexibility, which likely results from a significant relative chain-end contribution to the average chain dynamics, could be related to the strong structural polymorphism of the investigated oligonucleotides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental station for laser-based picosecond time-resolved x-ray absorption near-edge spectroscopy

We present an experimental station designed for time-resolved X-ray Absorption Near-Edge Spectroscopy (XANES). It is based on ultrashort laser-plasma x-ray pulses generated from a table-top 100 mJ-class laser at 10 Hz repetition rate. A high transmission (10%–20%) x-ray beam line transport using polycapillary optics allows us to set the sample in an independent vacuum chamber, providing high flexibility over a wide spectral range from 0.5 up to 4 keV. Some XANES spectra are presented, demonstrating 1% noise level in only ∼1 mn and ∼100 cumulated laser shots. Time-resolved measurements are reported, indicating that the time resolution of the entire experimental station is 3.3 ± 0.6 ps rms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗