Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phosphor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Acoustic holography: Problems associated with construction and reconstruction techniques

The implications of the difference between the inspecting and interrogating radiations are discussed. For real-time, distortionless, sound viewing, it is recommended that infrared radiation of wavelength comparable to the inspecting sound waves be used. The infrared images can be viewed with (IR visible) converter phosphors. The real-time display of the visible image of the acoustically-inspected object at low sound levels such as are used in medical diagnosis is evaluated. In this connection attention is drawn to the need for a phosphor screen which is such that its optical transmission at any point is directly related to the incident electron beam intensity at that point. Such a screen, coupled with an acoustical camera, can enable instantaneous sound wave reconstruction.

Singh, J. J.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Electrolytic Sharpening of Diode-Contact Whiskers

Phosphor bronze wire pointed without highly-toxic chemical reagents. Phosphor bronze wire to be pointed affixed to metal post held by fixture, such as pin vise. Fixture moved axially by micrometer allows precise control of position of end of wire with respect to surface of pointing solution. Solution consists of 4 weight percent sulfamic acid crystals in deionized water. Dissolution current adjusted via the autotransformer setting.

Green, G.↗

Thin wire pointing method

A method is described for forming sharp tips on thin wires, in particular phosphor bronze wires of diameters such as one-thousandth inch used to contact micron size Schottky barrier diodes, which enables close control of tip shape and which avoids the use of highly toxic solutions. The method includes dipping an end of a phosphor bronze wire into a dilute solution of sulfamic acid and applying a current through the wire to electrochemically etch it. The humidity in the room is controlled to a level of less than 50%, and the voltage applied between the wire and another electrode in the solutions is a half wave rectified voltage. The current through the wire is monitored, and the process is stopped when the current falls to a predetermined low level.

Green, G.↗

Use of Landsat data to predict the trophic state of Minnesota lakes

Near-concurrent Landsat Multispectral Scanner (MSS) and ground data were obtained for 60 lakes distributed in two Landsat scene areas. The ground data included measurement of secchi disk depth, chlorophyll-a, total phosphorous, turbidity, color, and total nitrogen, as well as Carlson Trophic State Index (TSI) values derived from the first three parameters. The Landsat data best correlated with the TSI values. Prediction models were developed to classify some 100 'test' lakes appearing in the two analysis scenes on the basis of TSI estimates. Clouds, wind, poor image data, small lake size, and shallow lake depth caused some problems in lake TSI prediction. Overall, however, the Landsat-predicted TSI estimates were judged to be very reliable for the secchi-derived TSI estimation, moderately reliable for prediction of the chlorophyll-a TSI, and unreliable for the phosphorous value. Numerous Landsat data extraction procedures were compared, and the success of the Landsat TSI prediction models was a strong function of the procedure employed.

Lillesand, T. M.↗

Recent advances in electroluminescent displays applicable to future crew-station interfaces

The operative principles and progress to date on producing thin-film electroluminescent displays (TFEL) are discussed. TFEL displays consist of conductive, insulating and phosphor film layers deposited on a glass substrate. Applying a 200 V potential between the rows and columns in a multiplexed mode causes light to be emitted. Varying the voltage varies the grey level. The panels provide adequate contrast in full sunlight, and have demanded only 4-6 W for 15 sq in. displays. Alphanumeric, graphics, and video images have been generated with a 51 line by 80 character display. The upper limit on the panel size has not yet been defined. Efforts are under way to produce multicolor displays using red and blue phosphors. Trial units are being studied for avionics displays for, e.g., navigation, multipurpose displays, and attitude/direction indicators.

Miller, M. R.↗

Regulation of bone mineral loss during lactation

The effects of varyng dietary calcium and phosphorous levels, vitamin D deficiency, oophorectomy, adrenalectomy, and simultaneous pregnancy on bone mineral loss during lactation in rats are studied. The experimental procedures and evaluations are described. The femur ash weight of lactating and nonlactating rats are calculated. The data reveals that a decrease in dietary calcium of 0.02 percent results in an increased loss of bone mineral, an increase in calcium to 1.4 percent does not lessen bone mineral loss, and bone mineral loss in vitamin D deficient rats is independent of calcium levels. It is observed that changes in dietary phosphorous level, oophorectomy, adrenalectomy, and simultaneous pragnancy do not reduce bone mineral loss during lactation. The analysis of various hormones to determine the mechanism that triggers bone mineral loss during lactation is presented.

Brommage, R.↗

Two-Layer, Full-Color Electroluminescent Display

Full-color, matrix-addressed electroluminescent display uses three different color phosphors located in two separate, superimposed layers to provide higher brightness, better contrast ratio, and higher resolution. Design used for such transparent, flat-panel display media as thin-film electroluminescent phosphors, liquid crystals, or light-emitting diodes.

Robertson, J. B.↗

Readout techniques for photon-counting microchannel image systems

A comparative evaluation is made of such readout methods for the microchannel plates that are commonly used in EUV, FUV, and X-ray low light level image systems as the (1) phosphor-video, (2) phosphor and binary-mask encoder, (3) direct discrete-position encoder, (4) direct analog amplitude position-encoder systems, and (5) delay-line encoders. Relative advantages and limitations are discussed in the context of low light level space-based astronomy applications. The delay-line technique offers great promise for high-resolution applications where oversampling is mandatory, as in spectroscopy.

Lampton, Michael↗

Mach 6 electroformed nickel nozzle refurbishment: FNAS investigation of ultra-smooth surfaces

The task objective has been to apply a coating of nickel-phosphorous alloy to a laminar flow wind tunnel nozzle by catalytic deposition and then polish and inspect the inside surface using optical device processes. The surface of the nozzle was coated with a nickel-phosphorous alloy of sufficient hardness and corrosion resistance to improve the durability. Due to plating defects that were clearly process related and not inherent, the final polished part was less than the desired quality. Surface finishing processes and lapping media were identified which produced a submicron surface finish on the interior plated surface. Defects apparently manifested by the first plating attempt were repaired using a small brush plating process demonstrating that individual small defects can be repaired. Measurement and analysis by profilometry demonstrated that quantitative control of the surface can be achieved.

Rood, Robert↗

Effects of 1-week head-down tilt bed rest on bone formation and the calcium endocrine system

The -6-deg head-down tilt (HDT) is employed in the study of 8 subjects to determine early responses in human bone and calcium endocrines during spaceflight. The average rates of bone formation in the iliac crest are determined by means of a single-dose labeling schedule and are found to decrease in 6 of the subjects. The decrease varies directly with walking miles, and increased excretion of urinary Ca and Na are observed preceding increased levels of ionized serum calcium on a bed-rest day late in the week. Reduced phosphorous excretions are also followed by increased serum phosphorous on day six, and reductions are noted in parathyroid hormone and vitamin D by the end of the experiment. The data demonstrate the responsiveness of the skeletal system to biomechanical stimuli such as the HDT.

Arnaud, Sara B.↗

Effects of coolant parameters on steady state temperature distribution in phospheric-acid fuel cell electrode

The influence of thermophysical properties and flow rate on the steady-state temperature distribution in a phosphoric-acid fuel cell electrode plate was experimentally investigated. An experimental setup that simulates the operating conditions prevailing in a phosphoric-acid fuel cell stack was used. The fuel cell cooling system utilized three types of coolants to remove excess heat generated in the cell electrode and to maintain a reasonably uniform temperature distribution in the electrode plate. The coolants used were water, engine oil, and air. These coolants were circulated at Reynolds number ranging from 1165 to 6165 for water; 3070 to 6864 for air; and 15 to 79 for oil. Experimental results are presented.

Alkasab, K. A.↗

Electroluminescent Displays Made With Alternative Dopants

Metals and metal fluorides deposited in ZnS to form color phosphors. Single-layer, thin-film electroluminescent display device contains ZnS host layer doped to form green, red, and blue phosphors. Luminescence in chosen colors at chosen intersections between rows and columns produced by application of voltages to appropriate row-and-column pairs of conductors.

Robertson, James B.↗

Chemical Strips Anodic Film From Aluminum

Phosphoric acid solution offers advantages over other stripping solutions. More effective than other strippers and safer to use. Relatively environmentally benign, phosphoric acid stripper ceases its chemical attack so less process control is needed in its use.

Eichinger, Eric C.↗

Development of a hydrogen gas sensor using microfabrication technology

Microfabrication and micromachining technologies are used to produce a hydrogen gas sensor based on a palladium-silver film. The sensor uses a heater that is fabricated by diffusing p-type borones into the substrate, forming a resistance heater. A diode for temperature measurement is produced using p-type boron and n-type phosphor diffused into the substrate. A thickness of the palladium-silver film is approximately 300 arcsec. The hydrogen gas sensor employs the proven palladium-silver diode structure and is surrounded by a phosphor doped resistance heater which can be heated up to a temperature of 250 C. Experimental results show that the sensor is capable of operating over a wide range of hydrogen concentration levels between 0-95 percent without any hysteresis effects.

Liu, Chung-Chiun↗

Effects of cooling system parameters on heat transfer in PAFC stack

Analytical and experimental study for the effects of cooling system parameters on the heat transfer and temperature distribution in the electrode plates of a phosphoric acid fuel-cell has been conducted. An experimental set-up that simulates the operating conditions prevailing in a phosphoric-acid fuel-cell stack was designed and constructed. The set-up was then used to measure the overall heat transfer coefficient, the thermal contact resistance, and the electrode temperature distribution for two different cooling plate configurations. Two types of cooling plate configurations, serpentine and straight, were tested. Air, water, and oil were used as coolants. Measurements for the heat transfer coefficient and the thermal contact resistance were made for various flow rates ranging from 16 to 88 Kg/hr, and stack clamping pressure ranging from O to 3448 Kpa. The experimental results for the overall heat transfer coefficient were utilized to derive mathematical relations for the overall heat transfer coefficient as a function of stack clamping pressure and Reynolds number for the three coolants. The empirically derived formulas were incorporated in a previously developed computer program to predict electrodes temperature distribution and the performance of the stack cooling system. The results obtained were then compared with those available in the literature. The comparison showed maximum deviation of +/- 11%.

Abdul-Aziz, Ali A.↗

Synthesis of low color, atomic oxygen resistant polyimides

The purpose of this project was to develop low color, atomic oxygen resistant polyimides for potential applications on spacecraft in low earth orbit. The material is needed in order to protect satellites and spacecraft from the gases and radiation found at those altitudes. Phosphorous containing polyimides have been shown to be especially resistant to corrosion and weight loss under oxygen plasma. Unfortunately the color of these phosphorous containing polyimides is still too high for them to be good heat insulators. While they are not as effective as teflon, the current material of choice. polyimides are much less dense than teflon and would be especially valuable if they could be made with low color. The approach taken was to synthesize a monomer which would contain the elements needed for giving the final polyimide its desired properties. In particular the monomer should incorporate phosphine or phosphine oxides and have bulky side groups to block any color forming charge transfer structures. The target molecule, 3,5-di-(trifluoromethylphenyl)-bis(3-aminophenyl) phosphine oxide, (containing both a phosphine oxide group and a bulky ditrifluoromethylphenyl group) was synthesized via three reactions in overall yield of 21 percent. In addition, a model compound, bis(3-phenylamine) phenyl phosphine oxide, was synthesized two different ways in order to establish the conditions for the nitration of phosphine oxides and their reduction to the amine. Finally, a trisubstituted phosphine oxide was synthesized. In all, seven phosphorus containing organic compounds were synthesized, purified and characterized. The model compound was reacted with oxydiphthalic anhydride to form a polyamic acid with inherent viscosity of 0.34. This material was cast into a film and heated, forming a normally colored fairly strong polyimide with a Tg of 240 C. The target compound was reacted with 6-fluorodiphthalic anhydride to give a polyamic acid with inherent viscosity of 0.19 and cast to give a heavily cracked colored film with a Tg of 230 C.

MacInnes, Dave↗

Site-Competition Epitaxy for N-Type and P-Type Dopant Control in CVD Sic Epilayers

The use of site-competition epitaxy, which is based on intentional variation of the Si/C ratio during epitaxy, has now been reproduced in numerous national and international laboratories. However, previous reports have only considered dopant incorporation control for epitaxy on the Si-face 6H-SiC(OOO1) substrates. Presented in this paper is the extension of this technique for control of phosphorous incorporation and also a comparison of controlled doping on C-face 6H-SiC(OOO1) versus Si-face 6H-SiC(OOO1) substrates for aluminum, boron, nitrogen, and phosphorous.

Larkin, D. J.↗