Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fatigability and Blood Flow in the Rat Gastrocnemius-Plantaris-Soleus after Hindlimb Suspension

The purpose of this study was to test the hypothesis that hindlimb suspension increases the fatigability of the soleus during intense contractile activity and determine whether the increased fatigue is associated with a reduced muscle blood flow. Cage-control (C) and 15-day hindlimb-suspended (HS) rats were anesthetized, and either the gastrocnemius-plantaris-soleus (G-P-S) muscle group or the soleus was stimulated (100 Hz, 100-ms trains at 120/min) for 10 min in situ. In the G-P-S preparation, blood flow was measured with radiolabeled microspheres before and at 2 and 10 min of contractile activity. The G-P-S fatigued markedly at this stimulation frequency, and the differences between C and HS animals were not significant until the 9th min of contractile activity. In contrast, the stimulation resulted in faster rates and significantly larger amounts of fatigue in the soleus from HS than from C animals. The atrophied soleus showed significant differences by I min of stimulation (C = 70 +/- 1% vs. HS = 57 +/- 2% of peak train force) and remained different at 10 min (C = 64 +/- 4% vs. HS = 45 +/- 2% peak train force). Relative blood flow to the soleus was similar between groups before and during contractile activity (rest: C = 20 +/- 3 vs. HS= 12 +/- 3; 2 min: C= 128 +/- 6 vs. HS = 118 +/- 4; 10 min: C = 123 +/- 11 vs. HS = 105 +/- 11 ml min(exp -1) 100 g(exp -1)). In conclusion, these results established that 15 days of HS increased the fatigability of the soleus, but the effect was not caused by a reduced muscle blood flow.

McDonald, K. S.↗

Numerical study of three-dimensional separation and flow control at a wing/body junction

The problem of three-dimensional separation and flow control at a wing/body junction has been investigated numerically using a three-dimensional Navier-Stokes code. The numerical code employs an algebraic grid generation technique for generating the grid for unmodified junction and an elliptic grid generation technique for filleted fin junction. The results for laminar flow past a blunt fin/flat plate junction demonstrate that after grid refinement, the computations agree with experiment and reveal a strong dependency of the number of vortices at the junction on Mach number and Reynolds number. The numerical results for pressure distribution, particle paths and limiting streamlines for turbulent flow past a swept fin show a decrease in the peak pressure and in the extent of the separated flow region compared to the laminar case. The results for a filleted juncture indicate that the streamline patterns lose much of their vortical character with proper filleting. Fillets with a radius of three and one-half times the fin leading edge diameter or two times the incoming boundary layer thickness, significantly weaken the usual necklace interaction vortex for the Mach number and Reynolds number considered in the present study.

Ash, Robert L.↗

Convection in a Very Compressible Fluid: Comparison of Simulations With Experiments

The time profile (Delta)T(t) of the temperature difference, measured across a very compressible fluid layer of supercritical He-3 after the start of a heat flow, shows a damped oscillatory behavior before steady state convection is reached. The results for (Delta)T(t) obtained from numerical simulations and from laboratory experiments are compared over a temperature range where the compressibility varies by a factor of approx. = 40. First the steady-state convective heat current j(sup conv) as a function of the Rayleigh number R(alpha) is presented, and the agreement is found to be good. Second, the shape of the time profile and two characteristic times in the transient part of (Delta)T(t) from simulations and experiments are compared, namely: 1) t(sub osc), the oscillatory period and 2) t(sub p), the time of the first peak after starting the heat flow. These times, scaled by the diffusive time tau(sub D) versus R(alpha), are presented. The agreement is good for t(sup osc)/tau(sub D), where the results collapse on a single curve showing a powerlaw behavior. The simulation hence confirms the universal scaling behavior found experimentally. However for t(sub p)/tau(sub D), where the experimental data also collapse on a single curve, the simulation results show systematic departures from such a behavior. A possible reason for some of the disagreements, both in the time profile and in t(sub p) is discussed. In the Appendix a third characteristic time, t(sub m), between the first peak and the first oscillation minimum is plotted and a comparison between the results of experiments and simulations is made.

Meyer, H.↗

Asymptotic behavior of a flat plate wake

An experimental study has been conducted to investigate the far-field, self-similar properties of a flat plate wake. A plane turbulent wake was generated at the trailing edge of a smooth splitter plate separating two legs of a Mixing Layer Wind Tunnel, with both initial boundary layers tripped. For the present study, both legs were operated at a free-steam velocity in the test section of 15 m/s, giving a Reynolds number based on wake momentum thickness of about 1750. Single profile measurements were obtained at five streamwise locations using a Pitot probe for the mean velocity measurements and a single cross-wire probe for the turbulence data, which included statistics up to third order. The mean flow data indicated a self-similar behavior beyond a streamwise distance equivalent to about 350 wake momentum thicknesses. However, the turbulence data show better collapse beyond a distance equivalent to about 500 momentum thicknesses, with all the measured peak Reynolds stresses achieving constant, asymptotic levels. The asymptotic mean flow behavior and peak primary stress levels agree well with theoretical predictions based on a constant eddy viscosity model. The present data also agree reasonably well with previous measurements, of which only one set extends into the self-similar region. Detailed comparisons with previous data are presented and discussed in this report.

Weygandt, James H.↗

Resource Analysis for Deep Direct-Use Feasibility Study in East Texas, Part 2

The National Renewable Energy Laboratory, Southern Methodist University Geothermal Laboratory, Eastman Chemical, Turbine Air Systems, and the Electric Power Research Institute are evaluating the feasibility of using geothermal heat to improve the efficiency of natural gas power plants. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of the Sabine Uplift. Part 2 focus on: 1) Permit report and spreadsheet on Federal, State, and Local agency requirements for a geothermal deep direct-use project in the vicinity of East Texas for Harrison, Gregg, Rusk, and Panola Counties. 2) Evaluation of the Geologic Variability of Travis Peak Formation as a reservoir. 3) Updated Heat Flow Memo with additional references.

15 GEOTHERMAL ENERGY↗

Acute Increase in Hepatic Arterial Flow During TIPS Identified by Intravascular Flow Measurements

The purpose of this study was to investigate alterations of hepatic arterial flow during transjugular intrahepatic portosystemic stent shunt (TIPS) applying intravascular Doppler sonography. This prospective monocenter study included 25 patients with liver cirrhosis (alcohol induced [n = 19], chronic hepatitis associated [n = 3], primary biliary cirrhosis associated [n = 1], and cryptogenic [n = 2]) successfully treated with TIPS. All patients underwent intravascular hepatic arterial flow measurements during TIPS using an endoluminal flow sensor. The average arterial peak velocity (APV) and the maximum arterial peak velocity (MPV) were registered. Twenty-two patients (88%) showed increased APV, one patient (4%) showed unaffected APV, and two patients (8%) showed decreased APV after TIPS. The average portosystemic pressure gradient decreased significantly, from 22.0 {+-} 5.1 mmHg before TIPS to 11.0 {+-} 4.1 mmHg after TIPS (-50.0%; p < 0.0001). The average APV increased significantly, from 41.9 {+-} 17.8 cm/s before TIPS to 60.7 {+-} 19.0 cm/s after TIPS (+44.9%; p < 0.0001). The average MPV increased significantly, from 90.8 {+-} 31.7 cm/s before TIPS to 112.6 {+-} 34.9 cm/s after TIPS (+24.0%; p = 0.0002). These changes in perfusion set in within seconds after TIPS tract formation in all the patients with increased APV. We conclude that TIPS-induced portosystemic decompression leads to a significant increase in hepatic arterial flow. The changes occurred within seconds, suggesting a reflex-like mechanism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study on Tensile Deformation Behavior of TC21 Titanium Alloy

To investigate the tensile deformation behavior of TC21 titanium alloy wires, the isothermal tensile deformation tests were conducted by a Geeble-1500D simulator in the temperature range of 720-880 °C and strain rates of 0.01-10 s{sup −1}. The in situ tensile deformation behavior has been studied by SEM SURPA40. The stress–strain curves indicate that the flow stress has shown an inverse relationship with temperature and a direct relationship with strain rate. The flow stress immediately reached the peak value and, then, gradually decreased due to the dynamic softening induced by dynamic recovery and dynamic recrystallization. According to the hot processing maps, the temperatures ranging from 720 to 760 °C (corresponding to the strain rates of 0.01-0.032 s{sup −1}) and 800-840 °C (corresponding to the strain rates of 0.01-0.056 s{sup −1}) are suitable for processing. The in situ tensile results reveal that the cracks initiated at the pre-fabricated defects with the concentrated stress and mainly propagated in the transgranular mode.

36 MATERIALS SCIENCE↗

Overall and blade-element performance of a transonic compressor stage with multiple-circular-arc blades at tip speed of 419 meters per second

A 50-centimeter-diameter axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested to study the effects of blade shape on efficiency and stall margin. At design speed, peak efficiency of 0.80 occurred at an equivalent weight flow of 29.0 kilograms per second. Measured total pressure ratio and total temperature ratio at peak efficiency were 1.69 and 1.20, respectively. The stall margin at design speed and an equivalent weight flow of 29.0 kilograms per second was 9 percent. The measured stall margin at design weight flow and speed was 15 percent. A comparison of rotor performance made with and without the stator showed a decrease in pressure ratio, peak efficiency, and maximum weight flow with the addition of the stator.

Kovich, G.↗

Analysis of VTR Primary Pump Coastdown

Simulations were performed to evaluate how different flow coastdown rates impact transient results. These simulations were performed with a preliminary SAS4A/SASSYS-1 model of the VTR to assess the advantages and disadvantages of delaying a pump trip following a control rod scram. When the control rods are inserted into the core by the reactor protection system, fission power will drop quickly. Pumps should be tripped soon after to avoid decreasing the power-to-flow ratio too much and preventing thermal shock of components in and above the core. The primary motivation for this report is characterizing the temperatures of these components with various delays between the control rods scramming and the primary pumps tripping. In the simulations with a control rod scram and a delayed pump trip, even if one of the pump coastdown mechanisms fails, a faster pump trip and coastdown is preferable. This can be achieved both by shortening the delay between the scram and trip as well as by decreasing the inertia provided by the coastdown mechanism. Based on the results of these simulations, there is no benefit to delaying when the pumps trip following a control rod scram. In other scenarios, however, a slow flow coastdown rate is preferable. Results from unprotected loss of flow simulations are presented to demonstrate that a slower coastdown reduces how much temperatures increase within the core. An initial flow halving time of between five and seven seconds was predicted to produce peak in-core temperatures with sufficient margins to the limiting criteria. For halving times less than five seconds, peak temperatures significantly reduce margins. For halving times greater than seven seconds in the unprotected loss of flow cases, the resulting peak temperatures are lower, but this leads to unfavorable results for the previous cases with a control rod scram. In order to achieve an acceptable balance between cases with and without a preceding control rod scram, the results presented in this report support an initial flow halving time in the five-to-seven second range, although ongoing PRA analysis could produce results that support a coastdown beyond this range.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser skin friction measurements and CFD comparison of weak-to-strong swept shock/boundary-layer interactions

A joint experimental and computational study of skin friction in weak-to-strong swept shock wave/turbulent boundary-layer interactions has been carried out. A planar shock wave is generated by a sharp fin at angles of attack alpha = 10 deg and 16 deg at M(infinity) = 3 and 16 and 20 deg at M(infinity) = 4. Measurements are made using the Laser Interferometer Skin Friction meter, which optically detects the rate of thinning of an oil film applied to the test surface. The results show a systematic rise in the peak c(f) at the rear part of the interaction, where the separated flow atttaches. For the stronget case studied, this peak is an order of magnitude higher than the incoming freestream c(f)level.

Kim, K.-S.↗

The Effect of Jet Flow Impingement on the Corrosion Products Formed on a Pipeline Steel in Naturally Aerated Sour Brine

Corrosion was generated by the action of a jet impingement flow of sour brine on pipeline steel samples of X70. Flow-assisted corrosion affected nature, number and peak intensity of the chemical species formed as corrosion products. Iron sulfides predominated in static and low flow rate conditions (1.1 m/s), whereas at 2.4 m/s iron oxides were mainly formed, which led to higher corrosion rates and suggested that oxides are less protective than sulfides. On inhibition, imidazoline seems to mitigate oxide formation and support sulfide formation balancing both species on steel surface. Ferrite phase in laminar pearlite was preferentially dissolved with/without inhibitor, and mackinawite (FeS{sub 2}) was formed at every flow rate, angle with and without inhibitor. Theoretical stresses determined by computational flow dynamics for corrosion product removal showed a fair approximation to those proposed in the literature.

36 MATERIALS SCIENCE↗

Evaluation of Thyroid Disorders During Head-and-Neck Radiotherapy by Using Functional Analysis and Ultrasonography

Purpose: To evaluate thyroid function and vascular changes during radiotherapy for patients with head and neck cancer. Methods and Materials: Fifty patients treated with primary or postoperative radiotherapy for various cancers in the head and neck region were prospectively evaluated. The serum samples (triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH], free triiodothyronine [FT3], and free thyroxine [FT4]), the echo level of the thyroid gland, and color Doppler ultrasonography (CDU) parameters of the right inferior thyroid artery (RITA) of the patients were measured before and at regular intervals during radiotherapy. The thyroid gland dose-volume histograms of the patients were derived from their computed tomography-based treatment plans. Results: There was a significant fall in TSH level (p < 0.0001) but an increase in FT4 (p < 0.0001) and T4 (p < 0.022) levels during the radiotherapy course. The threshold dose required to produce significant changes was 12 Gy (Biologically Effective Dose in 2-Gy fractions, BED{sub 2}). There were significant rises in the patients' pulsatility index, resistive index, peak systolic velocity, blood volume flow levels, and RITA diameter (p < 0.0001), as detected by CDU during radiotherapy, compared to those parameters measured before the treatment. Hypoechogenicity and irregular echo patterns (p < 0.0001) were seen during radiotherapy compared to those before treatment. There was significant Pearson's correlation between the CDU parameters and T4, FT4, and TSH levels. Conclusions: Radiation-induced thyroiditis is regarded as primary damage to the thyroid gland. Thyroiditis can subsequently result in hypothyroidism or hyperthyroidism. Our results demonstrated that changes in thyroid vessels occur during radiotherapy delivered to patients. Vessel changes also can be attributed to the late effect of radiation on the thyroid gland. The hypoechogenicity and irregular echo patterns observed in patients may result from the increase in intrathyroidal flow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfacial Reactivity of Silicon Electrodes: Impact of Electrolyte Solvent and Presence of Conductive Carbon

Silicon (Si) is a promising high-capacity material for lithium-ion batteries; however, its limited reversibility hinders commercial adoption. Approaches such as particle and crystallite size reduction, introduction of conductive carbon, and use of different electrolyte solvents have been explored to overcome these electrochemical limitations. Herein, operando isothermal microcalorimetry (IMC) is used to probe the influence of silicon particle size, electrode composition, and electrolyte additives fluoroethylene carbonate and vinylene carbonate on the heat flow during silicon lithiation. In this work, the IMC data are complemented by X-ray photoelectron and Raman spectroscopies to elucidate differences in solid electrolyte interphase (SEI) composition. Nanosized (~50 nm, n-Si) and micrometer-sized (~4 μm, μ-Si) silicon electrodes are formulated with and without amorphous carbon and electrochemically lithiated in ethylene carbonate (EC), fluoroethylene carbonate (FEC), or vinylene carbonate (VC) based electrolytes. Notably, n-Si electrodes generate 53–61% more normalized heat relative to their μ-Si counterparts, consistent with increased surface area and electrode/electrolyte reactivity. Introduction of amorphous carbon significantly alters the heat flow profile where multiple exothermic peaks and increased normalized heat dissipation are observed for all electrolyte types. Notably, the VC-containing electrolyte demonstrates the greatest normalized heat dissipation of the electrode compositions tested showing as much as a 50% increase compared to the EC or FEC counterparts. The results are relevant to the understanding of silicon negative electrode function in the presence of electrolyte additives and provide insight relative to silicon containing cell reactivity and safety.

25 ENERGY STORAGE↗

Effect of local ExB flow shear on the stability of magnetic islands in tokamak plasmas

The influence of local ExB flow shear on a relatively wide, constant-{psi}, magnetic island embedded in a large-aspect-ratio, low-{beta}, circular cross-section tokamak plasma is examined, using a slab approximation to model the magnetic geometry. It is found that there are three separate solution branches characterized by low, intermediate, and high values of the shear. Flow shear is found to have a stabilizing effect on island solutions lying on the low and high shear branches, via a nonlinear modification of the ion polarization term in the Rutherford island width evolution equation, but to have a destabilizing effect on solutions lying on the intermediate shear branch. Moreover, the effect is independent of the sign of the shear. The modification of island stability by local ExB flow shear is found to peak when the magnitude of the shear is approximately v{sub i}/L{sub s}, where v{sub i} is the ion thermal velocity, and L{sub s} the magnetic shear length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermodynamic analysis of the Livermore molecular-dynamics simulations of dislocation-mediated plasticity

Results of recent large-scale molecular dynamics simulations of dislocation-mediated solid plasticity are compared with predictions of the statistical thermodynamic theory of these phenomena. These computational and theoretical analyses are in substantial agreement with each other in both their descriptions of strain-rate-dependent steady plastic flows and of transient stress peaks associated with initially small densities of dislocations. Lastly, the comparisons between the numerical simulations and basic theory reveal inconsistencies in some conventional phenomenological descriptions of solid plasticity.

97 MATHEMATICS AND COMPUTING↗

Near-field acoustical holography and acoustic power analysis of a simulated, highly heated supersonic jet

Although near-field acoustical holography (NAH) and acoustic intensity analysis have previously been used to investigate the apparent jet noise sources produced by military aircraft, explicit connections to supersonic jet characteristics cannot be made due to a lack of information about the exhaust plume. Here, to begin to bridge this gap and better understand the source information yielded by NAH, the current study instead applies NAH to a virtual measurement of the near-field pressures of a highly heated laboratory-scale supersonic jet generated by large-eddy simulation (LES). The holographic reconstructions of the pressure, particle velocity, and acoustic intensity are found to match the LES-generated acoustic field well and are used to calculate the acoustic power of the jet. The jet's calculated overall acoustic power is compared to the free-stream mechanical power, resulting in an acoustic efficiency of 1.5%. Ray-tracing of the acoustic intensity to the jet centerline generates an axial distribution of the acoustic power origin, showing that almost all the power originates from the supersonic portion of the flow and with the distribution peak upstream of the potential core tip. Holographic reconstruction of the pressures along the nozzle lipline captures the general spectral shape of the LES-generated pressures, though it underestimates the amplitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal-Hydraulic Simulations of Single Pin and Assembly Sector for IVG- 1M Reactor

Thermal-hydraulic simulations have been performed using computational fluid dynamics (CFD) for the highly-enriched uranium (HEU) design of the IVG.1M reactor at the Institute of Atomic Energy (IAE) at the National Nuclear Center (NNC) in the Republic of Kazakhstan. Steady-state simulations were performed for both types of fuel assembly (FA), i.e. the FA in rows 1 & 2 and the FA in row 3, as well as for single pins in those FA (600 mm and 800 mm pins). Both single pin calculations and bundle sectors have been simulated for the most conservative operating conditions corresponding to the 10 MW output power, which corresponds to a pin unit cell Reynolds number of only about 7500. Simulations were performed using the commercial code STAR-CCM+ for the actual twisted pin geometry as well as a straight-pin approximation. Various Reynolds-Averaged Navier-Stokes (RANS) turbulence models gave different results, and so some validation runs with a higher-fidelity Large Eddy Simulation (LES) code were performed given the lack of experimental data. These singled out the Realizable Two-Layer k-ε as the most accurate turbulence model for estimating surface temperature. Single-pin results for the twisted case, based on the average flow rate per pin and peak pin power, were conservative for peak clad surface temperature compared to the bundle results. Also the straight-pin calculations were conservative as compared to the twisted pin simulations, as expected, but the single-pin straight case was not always conservative with regard to the straight-pin bundle. This was due to the straight-pin temperature distribution being strongly influenced by the pin orientation, particularly near the outer boundary. The straight-pin case also predicted the peak temperature to be in a different location than the twisted-pin case. This is a limitation of the straight-pin approach. The peak temperature pin was in a different location from the peak power pin in every case simulated, and occurred at an inner pin just before the enrichment change. The 600 mm case demonstrated a peak clad surface temperature of 370.4 K, while the 800 mm case had a temperature of 391.6 K. These temperatures are well below the necessary temperatures for boiling to occur at the rated pressure. Fuel temperatures are also well below the melting point. Future bundle work will include simulations of the proposed low-enriched uranium (LEU) design. Two transient scenarios were also investigated for the single-pin geometries. Both were “model” problems that were focused on pure thermal-hydraulic behavior, and as such were simple power changes that did not incorporate neutron kinetics modeling. The first scenario was a high-power, ramp increase, while the second scenario was a low-power, step increase. A cylindrical RELAP model was also constructed to investigate its accuracy as compared to the higher-fidelity CFD. Comparisons between the two codes showed good agreement for peak temperatures in the fuel and at the cladding surface for both cases. In the step transient, temperatures at four axial levels were also computed. These showed greater but reasonable discrepancy, with RELAP outputting higher temperatures. These results provide some evidence that RELAP can be used with confidence in modeling transients for IVG.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of 1380-foot-per-second tip-speed axial-flow compressor rotor with blade tip solidity of 1.1

The aerodynamic design parameters are presented along with the overall and blade element performance, of an axial-flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.853 and occured at an equivalent weight flow of 65.7lb/sec. The total pressure ratio was 1.68. Design efficiency, weight flow, pressure ratio, and temperature ratio were 0.822, 65.3, 1.65, and 1.187, respectively. Stall margin for design speed was 14 percent based on the weight flows and pressure ratios at peak efficiency and just prior to stall.

Janetzke, D. C.↗