Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Composite Stiffened Panels: Part I - Stiffness, Thermal Expansion, and Thermal Bending Formulation for Finite Element Analysis

A method is presented for formulating stiffness terms and thermal coefficients of fiber-reinforced composite, stiffened panels for input to finite element analysis (FEA). The method is robust enough to handle panels with general cross sectional shapes, including those which are unsymmetric and/or unbalanced. New thermal coefficients are introduced to quantify panel response from through-the-thickness temperature gradients. Equations are defined for stiffness, thermal expansion, and thermal bending that consider the full complement of membrane, bending, membrane-bending coupling, and transverse shear behavior. A technique of implementing this capability with a single plane of shell finite elements using the MSC/NASTRAN(TradeMark) FEA program is revealed. Finally, an example of a composite, hat-stiffened panel is included to demonstrate errors that occur when an unsymmetric panel is symmetrically formulated as traditionally done. These erroneous values and the correct ones produced from the presented method are listed for the panel's stiffness matrices, thermal expansion and bending vectors, and the forces and moments that are thermally induced from in-plane and through-the-thickness temperature gradients.

Craig S Collier↗

CFD Simulations for Arc-Jet Panel Testing Capability Development Using Semi-Elliptical Nozzles

This paper reports computational simulations in support of arc-jet panel testing capability development using semi-elliptical nozzles in a high enthalpy arc-jet facility at NASA Ames Research Center. Two different semi-elliptical nozzle configurations are proposed for testing panel test articles. Computational fluid dynamics simulations are performed to provide estimates of achievable panel surface conditions and useful test area for each configuration. The present analysis comprises three-dimensional simulations of the nonequilibrium flowfields in the semi-elliptical nozzles, test box and flowfield over the panel test articles. Computations show that useful test areas for the proposed two nozzle options are 20.32 centimeters by 20.32 centimeters (8 inches by 8 inches) and 43.18 centimeters by 43.18 centimeters (17 inches by 17 inches). Estimated values of the maximum cold-wall heat flux and surface pressure are 155 watts per centimeters squared and 39 kilopascals for the smaller panel test option, and 44 watts per centimeters squared and 7 kilopascals for the larger panel test option. Other important properties of the predicted flowfields are presented, and factors that limit the useful test area in the semi-free jet test configuration are discussed.

TPS↗

CFD Simulations for Arc-Jet Panel Testing Capability Development Using Semi-Elliptical Nozzles

This paper reports computational simulations in support of arc-jet panel testing capability development using semi-elliptical nozzles in a high enthalpy arc-jet facility at NASA Ames Research Center. Two different semi-elliptical nozzle configurations are proposed for testing panel test articles. Computational fluid dynamics simulations are performed to provide estimates of achievable panel surface conditions and useful test area for each configuration. The present analysis comprises three-dimensional simulations of the nonequilibrium flowfields in the semi-elliptical nozzles, test box and flowfield over the panel test articles. Computations show that useful test areas for the proposed two nozzle options are 20.32 centimeters by 20.32 centimeters (8 inches by 8 inches) and 43.18 centimeters by 43.18 centimeters (17 inches by 17 inches). Estimated values of the maximum cold-wall heat flux and surface pressure are 155 watts per centimeters squared and 39 kilopascals for the smaller panel test option, and 44 watts per centimeters squared and 7 kilopascals for the larger panel test option. Other important properties of the predicted flowfields are presented, and factors that limit the useful test area in the semi-free jet test configuration are discussed.

CFD↗

AIAA ASCEND 2023 Panel Session Proposal: Community Perspectives on Establishing a Government-Funded National Laboratory in a Commercially-Driven LEO Ecosystem

AIAA ASCEND 2023 Panel Session Proposal: Community Perspectives on Establishing a Government-Funded National Laboratory in a Commercially-Driven LEO Ecosystem Submitted by the NASA Office of Technology, Policy, and Strategy March 8, 2023 Session Format: Panel Session Topic: Expanding and Evolving the Space Economy Session Title: Community Perspectives on Establishing a Government-Funded National Laboratory in a Commercially-Driven LEO Ecosystem Short Session Description: NASA is preparing for the retirement of the ISS and transition of government-sponsored low-Earth orbit (LEO) activities to Commercial LEO Destinations (CLDs), which includes a government-funded national lab. This transition necessitates new models to connect government-funded users of the LEO environment to CLDs. This panel will highlight updates on what may constitute a national laboratory, share perspectives from members of LEO user communities, and open the discussion for additional comments. Requested Session Duration: 90 minutes Extended Session Description: NASA is preparing for the retirement of the ISS and transition of low-Earth orbit (LEO) activities to Commercial LEO Destinations (CLDs), including planning for a national laboratory. This transition necessitates new models for connecting government-funded users of the LEO environment to CLDs. NASA has made progress on models and a stepwise strategy to enable this national laboratory. This session will discuss guiding national strategies and highlight perspectives on what constitutes a national laboratory from current user communities. A NASA panel participant will introduce the rationale for continuing a national laboratory utilizing CLDs and speak on progress-to-date. This includes furthering national priorities to continue a space-based microgravity national laboratory. It also may include a brief overview of a study conducted by NASA which elucidates a trade space of models for a national laboratory and highlights from an interagency working group on microgravity for additional context. A moderator and five panelists representing diverse LEO user communities will then share perspectives on topics relating to this new dynamic ecosystem, expectations for models and activities, and other thoughts on NASA’s progress. Panelists may consist of members from the following communities: NASA, other U.S. government agencies, startups, small businesses, academia, and non-profits. The panel then plans to open discussion to the audience for questions, input, and additional feedback. Session Goal(s)/Outcome(s): By hosting a panel session, NASA aims to accomplish two goals. First, NASA wishes to update the community on progress towards establishing a national laboratory in low-Earth orbit. This includes sharing key perspectives heard from stakeholder communities. The second goal is to highlight the collaborative nature of such an undertaking and to facilitate additional discussion with other current and future users of the LEO community. Participants (not exhaustive): Erica Rodgers; Robyn Gatens

Erica Marie Rodgers Heusinkveld↗

Panelized wall system with foam core insulation

A wall system includes a plurality of wall members, the wall members having a first metal panel, a second metal panel, and an insulating core between the first panel and the second panel. At least one of the first panel and the second panel include ridge portions. The insulating core can be a foam, such as a polyurethane foam. The foam can include at least one opacifier to improve the k-factor of the foam.

42 ENGINEERING↗

Self-supporting roof panel

A self-supporting panel is used to form building components, including roofs that have no independent supports for the panels between the ends of the panels. The panel system includes a base support or structural component having a top face sheet supported by longitudinally load carrying webs and a layer of insulation on the exterior of the face sheet. The insulation spans the entire face sheet to overlie connectors between the edges of adjacent panels when the panels are assembled to form a wall or roof, to eliminate thermal shorts.

Davidson, Jane↗

Towards low-carbon low-energy concrete alternatives: Life cycle assessment of carbonated cementitious material-based precast panels

Cement is responsible for 22 % of all global CO 2 emissions from industrial processes. Technological innovation for developing and deploying of alternative materials will be required to decarbonize the cement industry. Carbonated cementitious materials (CCMs) are building materials that rely on carbon mineralization for their strength. A process-based cradle-to-gate life cycle assessment (LCA) was conducted to evaluate the global warming potential (GWP), cumulative energy demand, and water consumption of a lab-scale CCM-based precast panel compared to a conventional precast concrete panel. Since the CCM process is currently a lab-scale early-stage process, the CCM panel showed higher environmental impacts compared to the conventional panel. However, scenario analyses include mature production process scenarios. In conclusion, a sensitivity analysis revealed that the GWP of CCM can be lowered to below that of the conventional panel using polymers, fillers, low-carbon electricity sources, and optimized carbonation parameters.

36 MATERIALS SCIENCE↗

Recovery of valuable components from waste LCD panel through a dry physical method

Highlights: • This paper aims at harmless treatment and resource recovery of waste LCD panel. • Indium tin oxide (ITO) was enriched from CF and TFT glass through mechanical exfoliation. • Vibrated gas-solid fluidized bed separation was introduced to investigate the separation of polarizing film and glass. •One flowsheet for recycling waste LCD panel synthetically which combine dry methods is proposed. - Abstract: A waste liquid crystal display (LCD) panel was recycled synthetically and cleanly by using dry physical methods, namely, mechanical exfoliation, dry crushing and vibrated gas–solid fluidized bed separation. Results of elemental and phase analyses show that indium and tin contents were enriched greatly in indium tin oxide concentrate obtained from colour filter and thin-film transistor glass. The results of crushing, ash content and scanning electron microscopic analyses show that when the LCD panel was crushed into particles smaller than 0.25 mm, the polarizer film is nearly completely liberated from the glass. Moreover, the results of vibrated gas–solid fluidized bed separation show that gas velocity and separation time are the main factors influencing the separation. The vibration intensity of 6.8, gas velocity of 13.6 cm/s and fluidizing time of 30 s are the optimum operating parameters, and the degree of separation and recovery of polarizing film reached up to 37.69 and 72.3%, respectively. Based on these results, the combination of dry enrichment, dry crushing and dry separation in a flowsheet is proposed for recycling of waste LCD panel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LOW SCATTER, HIGH KILOVOLT, A-SI FLAT PANEL X-RAY DETECTOR

We have been using amorphous silicon (a-Si) flat panel detectors in high energy (>400 kV) cone beam computed tomography (CT) applications for a number of years. We have found that these detectors have a significant amount of internal scatter that degrades the accuracy of attenuation images. The scatter errors cause cupping and streaking artifacts that are practically indistinguishable from beam hardening artifacts. Residual artifacts remain after beam hardening correction and over correction increases noise in CT reconstructions. Another important limitation of existing detectors is that they have a high failure rate, especially when operating at megavolt x-ray energies even with a well collimated beam. Due to the limitations of the current detectors, we decided to design a detector specifically for high energies that has significantly reduced scatter. In collaboration with IMTEC, we have built a prototype amorphous silicon flat panel detector that has both improved imaging response and increased lifetime. LANL's contribution is the ''transparent panel concept''(patent pending), in which structures in the x-ray beam path are either eliminated or made as transparent to x-rays as practical (low atomic number and low areal density). This reduces scatter, makes attenuation measurements more accurate, improves the ability to make corrections for beam hardening, and increases signal to noise ratio in DR images and CT reconstructions. IMTEC's contribution is an improved shielding design that will increase the lifetime of the panel. Preliminary results showing the dramatic reduction in self scatter from the panel will be presented as well as the effect of this improvement on CT images.

36 MATERIALS SCIENCE↗

Automatic outdoor monitoring system for photovoltaic panels

Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. Here, the instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

14 SOLAR ENERGY↗

Analysis of a free-running synchronization artifact correction for MV-imaging with aSi:H flat panels

Purpose: Solid state flat panel electronic portal imaging devices (EPIDs) are widely used for megavolt (MV) photon imaging applications in radiotherapy. In addition to their original purpose in patient position verification, they are convenient to use in quality assurance and dosimetry to verify beam geometry and dose deposition or to perform linear accelerator (linac) calibration procedures. However, native image frames from amorphous silicon (aSi:H) detectors show a range of artifacts which have to be eliminated by proper correction algorithms. When a panel is operated in free-running frame acquisition mode, moving vertical stripes (periodic synchronization artifacts) are a disturbing feature in image frames. Especially for applications in volumetric intensity modulated arc therapy (VMAT) or motion tracking, the synchronization (sync) artifacts are the limiting factor for potential and accuracy since they become even worse at higher frame rates and at lower dose rates, i.e., linac pulse repetition frequencies (PRFs). Methods: The authors introduced a synchronization correction method which is based on a theoretical model describing the interferences of the panel's readout clocking with the linac's dose pulsing. Depending on the applied PRF, a certain number of dose pulses is captured per frame which is readout columnwise, sequentially. The interference of the PRF with the panel readout is responsible for the period and the different gray value levels of the sync stripes, which can be calculated analytically. Sync artifacts can then be eliminated multiplicatively in precorrected frames without additional information about radiation pulse timing. Results: For the analysis, three aSi:H EPIDs of various types were investigated with 6 and 15 MV photon beams at varying PRFs of 25, 50, 100, 200, and 400 pulses per second. Applying the sync correction at panels with gadolinium oxysulfide scintillators improved single frame flood field image quality drastically [improvement of the signal-to-noise ratio (SNR) up to 66.1 dB for 6 MV and 66.0 dB for 15 MV]. Also for the EPID with a caesium iodide scintillator, the noise for the lower PRFs could be reduced (SNR at 6 MV of up to 56.3 dB and at 15 MV up to 46.7 dB). However, the simplistic readout interference model fails at higher PRFs, where image lag and ghosting effects due to trapped charges in the thin film transistor and scintillator postglowing require additional corrections. Conclusions: The presented free-running sync correction method improves SNR of single frames and enables imaging applications, like low-dose rate imaging at increased image frame rates (e.g., to track moving gold fiducials in the lung). Adaptive image guided radiotherapy protocols become even feasible in VMAT plans. Also simultaneous kilovolt and MV imaging applications can benefit from new possibilities of MV scatter removal in x-ray images.

60 APPLIED LIFE SCIENCES↗

Attic Retrofits Using Nail-Base Insulated Panels

This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracking Performance of Upgraded "Polished Panel" Optical Receiver on NASA's 34 Meter Research Antenna

There has been considerable interest in developing and demonstrating a hybrid "polished panel" optical receiver concept that would replace the microwave panels on the Deep Space Network's (DSN) 34 meter antennas with highly polished aluminum panels, thus enabling simultaneous opticaland microwave reception. A test setup has been installed on the 34 meter research antenna at DSS-13 (Deep Space Station 13) at NASA's Goldstone Deep Space Communications Complex in California in order to assess the feasibility of this concept. Here we describe the results of a recent effort todramatically reduce the dimensions of the point-spread function (PSF) generated by a custom polished panel, thus enabling improved optical communications performance. The latest results are compared to the previous configuration in terms of quantifiable PSF improvement. In addition, the performance of acquisition and tracking algorithms designed specifically for the polished panel PSF are evaluated and compared, based on data obtained from real-time tracking of planets and bright stars with the 34 meter research antenna at DSS-13.

optima↗

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗

Novel Human Radiation Exposure Biomarker Panel Applicable for Population Triage

Purpose: To identify a panel of radiation-responsive plasma proteins that could be used in a point-of-care biologic dosimeter to detect clinically significant levels of ionizing radiation exposure. Methods and Materials: Patients undergoing preparation for hematopoietic cell transplantation using radiation therapy (RT) with either total lymphoid irradiation or fractionated total body irradiation were eligible. Plasma was examined from patients with potentially confounding conditions and from normal individuals. Each plasma sample was analyzed for a panel of 17 proteins before RT was begun and at several time points after RT exposure. Paired and unpaired t tests between the dose and control groups were performed. Conditional inference trees were constructed based on panels of proteins to compare the non-RT group with the RT group. Results: A total of 151 patients (62 RT, 41 infection, 48 trauma) were enrolled on the study, and the plasma from an additional 24 healthy control individuals was analyzed. In comparison with to control individuals, tenascin-C was upregulated and clusterin was downregulated in patients receiving RT. Salivary amylase was strongly radiation responsive, with upregulation in total body irradiation patients and slight downregulation in total lymphoid irradiation patients compared with control individuals. A panel consisting of these 3 proteins accurately distinguished between irradiated patients and healthy control individuals within 3 days after exposure: 97% accuracy, 0.5% false negative rate, 2% false positive rate. The accuracy was diminished when patients with trauma, infection, or both were included (accuracy, 74%-84%; false positive rate, 14%-33%, false negative rate: 8%-40%). Conclusions: A panel of 3 proteins accurately distinguishes unirradiated healthy donors from those exposed to RT (0.8-9.6 Gy) within 3 days of exposure. These findings have significant implications in terms of triaging individuals in the case of nuclear or other radiologic events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal planning of the joint placement of photovoltaic panels and green roofs under climate change uncertainty

Photovoltaic (PV) panels directly convert sunlight into electricity; but, sunlight also heats the panels, negatively impacting their efficiency. Green roofs are vegetative layers grown on rooftops, mainly to provide added insulation on the roof to save energy. Green roofs also cool near-surface air temperature. Hence, the joint installation of PV panels and green roofs may potentially lead to higher efficiency of PV panels in certain climates. We develop a two-stage stochastic programming model to optimally place PV panels and green roofs under climate change uncertainty to maximize the overall profit from energy generated and saved. We calibrate the model using the literature, industry reports, and the data from different, at times conflicting, climate projections. We then conduct a case study for a mid-size city in the U.S., perform extensive sensitivity and robustness analyses and provide insights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Interactions Between Shading and Organic Fertilizer Application on Dry-farmed Tomato Grown Between Photovoltaic Panels

Agrivoltaic systems are mixed systems of solar photovoltaic (PV) panels and agricultural production, where shade from the panels can result in lower evapotranspiration for crops, which is of particular interest for dryland agriculture. Dry-farmed tomato (Solanum lycopersicum) production in the Willamette Valley of Oregon has lower total yields and higher rates of blossom-end rot (BER) than irrigated tomato production, resulting in reduced marketable yields. To determine how dry-farmed ‘Early Girl’ tomato performed in an agrivoltaics system, a trial was conducted at the Valley Creek Solar Project (Salem, OR, USA) in 2020, using three different amendment treatments and three levels of shading from the panels. Amendment treatments were 0N (receiving no fertilizer), 84N (receiving 84 kg·ha −1 N), and 168N (receiving 168 kg·ha −1 N), applied as processed chicken manure. Plants were estimated to receive an irradiance factor of 30%, 76%, and 89% for full-shade, partial-shade, and full-sun treatments respectively. There was an interaction between amendment treatments and shading treatments in their effects on unblemished yield (yield of fruit without BER or sunscald). The optimum fertilizer application for full-shade and partial-shade rows was 84N, the optimum for full-sun rows was 0N. Fertilizing these rows at these rates resulted in an unblemished yield for the aisle of 11.1 t·ha −1 , which was lower than unblemished yields reported in previous experiments and trials in open fields. However, these results are from a single location and a single year, and other solar sites may behave more similar to open-field conditions. Shading from the panels increased average fruit weight and decreased incidence of BER and sunscald, suggesting that crops were less drought stressed. This resulted in similar unblemished yields for the full-shade and full-sun plots at 84N and 168N. Applying fertilizer resulted in higher total yields, smaller average fruit weight, increased BER incidence, and decreased sunscald incidence. The results suggest a possible synergy between dry-farmed tomato production and agrivoltaics, although several concerns remain, including difficulties managing the vegetation under panels, rules restricting PVs on high-value agricultural soils, and the possibility of soil compaction during PV installation.

14 SOLAR ENERGY↗

Exterior Insulation Systems Containing Vacuum Insulation Panels Tested Using a Heat Flux Meter Apparatus

A proposed wall system that will provide a high thermal resistance in a relatively thin profile incorporates vacuum insulation panels (VIP) enclosed within closed-cell insulating foam. In addition to providing some additional thermal resistance, the foam protects the vacuum panels during construction and provides a surface appropriate for an adhesive joint on both sides of the foam-VIP unit. Multiple configurations of the composite structure were considered and experimental measurements were sought to provide more information in the final selection. Small sub-sections of each candidate arrangement were prepared and tested in a special-purpose heat flux meter apparatus. Those measurements are described here, along with additional modeling efforts based on these smaller-scale measurements. The focus of the tests reported here is to investigate the impact of vacuum panel size, the type of foam used to encase the vacuum panels, the thickness and shape of the foam sections between panels, and possible adhesive effects. A new procedure was developed to map the heat flux meter measurement results onto full-scale wall designs to predict the system thermal performance. Several potential arrangements of the foam-VIP unit were also evaluated using a finite-difference methodology. The report also evaluates procedures for testing VIPs in a heat flux meter apparatus, and makes some recommendations.

Childs, Kenneth W.↗