Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Scanning optical homodyne detection of high-frequency picoscale resonances in cantilever and tuning fork sensors

Higher harmonic modes in nanoscale silicon cantilevers and microscale quartz tuning forks are detected and characterized using a custom scanning optical homodyne interferometer. Capable of both mass and force sensing, these resonators exhibit high-frequency harmonic motion content with picometer-scale amplitudes detected in a 2.5 MHz bandwidth, driven by ambient thermal radiation. Quartz tuning forks furthermore display both in-plane and out-of-plane harmonics. The first six electronically detected resonances are matched to optically detected and mapped fork eigenmodes. Mass sensing experiments utilizing higher tuning fork modes suggest greater than six times sensitivity enhancement over fundamental mode operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electro-optical Tuning of Fabry-Perot Interferometers

Compact unit operates much faster than conventional piezoelectric scanners. High voltage creates electric field in Pockels cell, changing refractive properties. Cell changes optical path length between mirrors without mechanically moving anything in gap. High voltage varied rapidly to scan interferometer. Voltage applied longitudinally or transversely, depending on type of Pockels cell. New electro-optic scanner scans given range in one-millionth time of piezoelectric scanner - tens to hundreds of nanoseconds per interferometer order. Also reducing size of interferometer.

Schwemmer, G. K.↗

Hyper-Ramsey spectroscopy of optical clock transitions

We present nonstandard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties can be radically suppressed (by two to four orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly benefit from this method. In the latter case, these frequency shifts can be suppressed considerably below a fractional level of 10{sup -17}. Moreover, our approach opens the door for high-precision optical clocks based on direct frequency comb spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

JWST Optical Telescope Element Center of Curvature Test

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) completed element level integration and test programs and were integrated to the next level of assembly called OTE/ISIM (OTIS) at Goddard Space Flight Center (GSFC) in Greenbelt, Maryland in 2016. Before shipping the OTIS to Johnson Space Center (JSC) for optical test at cryogenic temperature a series of vibration and acoustic tests were performed. To help ensure that the OTIS was ready to be shipped to JSC an optical center of curvature (CoC) test was performed to measure changes in the mirror's optical performance to verify that the telescope's primary mirror was not adversely impacted by the environmental testing and help us in understanding potential anomalies identified during the JSC tests. The primary is a 6.5 meter diameter mirror consisting of 18 individual hexagonal segments. Each segment is an off-axis asphere. There are a total of three prescriptions repeated six times each. As part of the CoC test each segment was individually measured using a high-speed interferometer (HSI) designed and built specifically for this test. This interferometer is capable of characterizing both static and dynamic characteristics of the mirrors. The latter capability was used, with the aid of a vibration stinger applying a low-level input force, to measure the dynamic characteristic changes of the PM backplane structure. This paper describes the CoC test setup and both static and dynamic test results.

interferometer↗

Designs of multipass optical configurations based on the use of a cube corner retroreflector in the interferometer

We describe designs of the multipass optical configurations of an interferometer with high spectral resolution with respect to 6, 12, and 24 times more optical passes than the conventional Michelson interferometer. In each design, a movable cube corner retroreflector is combined with a folding reflector group (FRG) as the interferometer's moving combination to implement the multipass optical configuration with the characteristic of surface division. Analyses reveal that when there are 12 or more optical passes, the net effect of the ray's angular deviation of the entire moving combination amounts to only the alignment error of one of the reflectors in the FRG, demonstrating the self-aligning property of the interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated optics for coupled-cavity QED

We present an array of Fabry-Pérot free space microcavities, intended to contain atoms or other quantum emitters, coupled to each other by waveguides resonators on a chip. The concept is highly scalable and offers a unique degree of control, making it a promising platform for quantum simulations. We demonstrate experimentally the basic units of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-accuracy thickness measurement of a transparent plate with the heterodyne central fringe identification technique

In a modified Twyman-Green interferometer, the optical path variation is measured with the heterodyne central fringe identification technique, as the light beam is focused by a displaced microscopic objective on the front/rear surface of the test transparent plate. The optical path length variation is then measured similarly after the test plate is removed. The geometrical thickness of the test plate can be calculated under the consideration of dispersion effect. This method has a wide measurable range and a high accuracy in the measurable range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface topographical changes measured by phase-locked interferometry

An electronic optical laser interferometer capable of resolving depth differences of as low as 30 A and planar displacements of 6000 A was constructed to examine surface profiles of bearing surfaces without physical contact. Topological chemical reactivity was determined by applying a drop of dilute alcoholic hydrochloric acid and measuring the profile of the solid surface before and after application of this probe. Scuffed bearing surfaces reacted much faster than virgin ones but that bearing surfaces exposed to lubricants containing an organic chloride reacted much more slowly. The reactivity of stainless steel plates, heated in a nitrogen atmosphere to different temperatures, were examined later at ambient temperature. The change of surface contour as a result of the probe reaction followed Arrhenius-type relation with respect to heat treatment temperature. The contact area of the plate of a ball/plate sliding elastohydrodynamic contact run on trimethylopropane triheptanoate with or without additives was optically profiled periodically. As scuffing was approached, the change of profile within the contact region changed much more rapidly by the acid probe and assumed a constant high value after scuffing. A nonetching metallurgical phase was found in the scuff mark, which was apparently responsible for the high reactivity.

Lauer, J. L.↗

Suppression of Dephasing due to a Trapping Potential and Atom-Atom Interactions in a Trapped-Condensate Interferometer

We propose and demonstrate a novel trapped-condensate interferometer using optical Bragg diffractions in a harmonic magnetic potential, which can realize a long coherence time with low dephasing. Dephasing of wave packets due to the magnetic potential is canceled by setting the interrogation time equal to the oscillation period of the harmonic potential. The harmonic potential also helps to suppress dephasing due to condensate atom-atom interactions. An interference signal with a fringe contrast of 30% is observed at an interrogation time of 58 ms. For a longer interrogation time about 100 ms, the spatial coherence of the condensate is still maintained with low dephasing, although the interference fringe is washed out by external vibrational noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of a coherence loss of an atomic wave scattered from the optical potential in a Talbot-Lau atom interferometer

A coherence loss of an atomic wave scattered from the optical potential in an interferometer is observed. A Talbot-Lau atom interferometer is developed for that measurement using a laser-cooled lithium atomic beam. The long de Broglie wavelength of slow lithium atoms gives a short Talbot length and makes it possible to construct a small and stable atom interferometer.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diagnostics for fast ignition science (invited)

The ignition concept for electron fast ignition inertial confinement fusion requires sufficient energy be transferred from an {approx}20 ps laser pulse to the compressed fuel via approximately MeV electrons. We have assembled a suite of diagnostics to characterize such transfer, simultaneously fielding absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256 eV; spherically bent crystal imagers at 4.5 and 8 keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung, electron and proton spectrometers (along the same line of sight), and a picosecond optical probe interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following the laser-plasma interactions at extremely high intensities in both planar and conical targets. Together with accurate on-shot laser focal spot and prepulse characterization, these measurements are yielding new insights into energy coupling and are providing critical data for validating numerical particle-in-cell (PIC) and hybrid PIC simulation codes in an area crucial for fast ignition and other applications. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultrahigh intensity laser-plasma interactions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quadrature phase interferometer for high resolution force spectroscopy

In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the cantilever tip and a reference beam reflecting on the static base of the sensor. A design with very low environmental susceptibility and another allowing calibrated measurements on a wide spectral range are described. Both enable a very high resolution (down to 2.5×10{sup −15} m/√(Hz)), illustrated by thermal noise measurements on AFM cantilevers. They present an excellent long-term stability and a constant sensitivity independent of the optical phase of the interferometer. A quick review shows that our precision is equaling or out-performing the best results reported in the literature, but for a much larger deflection range, up to a few μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and numerical study of plastic shear instability under high-speed loading conditions

The behavior of specimens dynamically loaded during the split Hopkinson (Kolsky) bar tests in a regime close to simple shear conditions was studied. The lateral surface of the specimens was investigated in a real-time mode with the aid of a high-speed infra-red camera CEDIP Silver 450M. The temperature field distribution obtained at different time made it possible to trace the evolution of plastic strain localization. The process of target perforation involving plug formation and ejection was examined using a high-speed infra-red camera and a VISAR velocity measurement system. The microstructure of tested specimens was analyzed using an optical interferometer-profilometer and a scanning electron microscope. The development of plastic shear instability regions has been simulated numerically.

36 MATERIALS SCIENCE↗

Reconfigurable and ultra-sensitive in-line Mach-Zehnder interferometer based on the fusion of microfiber and microfluid

A reconfigurable Mach-Zenhnder interferometer (MZI) based on a microfluidic cavity (MFC) constructed by embedding a microfiber between two segments of single-mode fibers with pre-designed lateral offset has been proposed and experimentally demonstrated. The MFC serves as an interference arm with an eccentric annular cross section and allows convenient sample (gas or liquids) replacement procedure. The microfiber works as the other interference arm that provides the proposed device with ease of reconstruction and also enhances the force sensitivity. The re-configurability and the ultra-wide tuning sensitivity range are demonstrated by immersing the MZI constructed with a 484 μm-long-MFC and a microfiber 44 μm in diameter in different droplets. Ultrahigh sensitivities of 34.65 nm/°C (∼88 380 nm/RIU) and −493.7 nm/N (∼−590 pm/με) are experimentally achieved using a droplet with a refractive index of ∼1.44.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of plastic strain localization mechanisms caused by nonequilibrium transitions in mesodefect ensembles under high-speed loading

The behavior of specimens dynamically loaded during split Hopkinson (Kolsky) bar tests in a regime close to simple shear conditions was studied. The lateral surface of the specimens was investigated in-situ using a high-speed infrared camera CEDIP Silver 450M. The temperature field distribution obtained at different time allowed one to trace the evolution of plastic strain localization. The process of target perforation involving plug formation and ejection was examined using a high-speed infrared camera and a VISAR velocity measurement system. The microstructure of tested specimens was analyzed using an optical interferometer-profiler and a scanning electron microscope. The development of plastic shear instability regions has been simulated numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray spectroscopy evidence for plasma shell formation in experiments modeling accretion columns in young stars

Recent achievements in laboratory astrophysics experiments with high-power lasers have allowed progress in our understanding of the early stages of star formation. In particular, we have recently demonstrated the possibility of simulating in the laboratory the process of the accretion of matter on young stars [G. Revet et al., Sci. Adv. 3, e1700982 (2017)]. The present paper focuses on x-ray spectroscopy methods that allow us to investigate the complex plasma hydrodynamics involved in such experiments. We demonstrate that we can infer the formation of a plasma shell, surrounding the accretion column at the location of impact with the stellar surface, and thus resolve the present discrepancies between mass accretion rates derived from x-ray and optical-radiation astronomical observations originating from the same object. In our experiments, the accretion column is modeled by having a collimated narrow (1 mm diameter) plasma stream first propagate along the lines of a large-scale external magnetic field and then impact onto an obstacle, mimicking the high-density region of the stellar chromosphere. A combined approach using steady-state and quasi-stationary models was successfully applied to measure the parameters of the plasma all along its propagation, at the impact site, and in the structure surrounding the impact region. The formation of a hot plasma shell, surrounding the denser and colder core, formed by the incoming stream of matter is observed near the obstacle using x-ray spatially resolved spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗