Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Status of Technological Advancements for Reducing Aircraft Gas Turbine Engine Pollutant Emissions

Combustor test rig results indicate that substantial reductions from current emission levels of carbon monoxide (CO), total unburned hydrocarbons (THC), oxides of nitrogen (NOx), and smoke are achievable by employing varying degrees of technological advancements in combustion systems. Minor to moderate modifications to existing conventional combustors produced significant reductions in CO and THC emissions at engine low power (idle/taxi) operating conditions but did not effectively reduce NOx at engine full power (takeoff) operating conditions. Staged combusiton techniques were needed to simultaneously reduce the levels of all the emissions over the entire engine operating range (from idle to takeoff). Emission levels that approached or were below the requirements of the 1979 EPA standards were achieved with the staged combustion systems and in some cases with the minor to moderate modifications to existing conventional combustion systems. Results from research programs indicate that an entire new generation of combustor technology with extremely low emission levels may be possible in the future.

Rudey, R. A.↗

Advanced Stirling Convertor Durability Testing: Plans and Interim Results

The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, GRC has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

Meer, David W.↗

Advanced Stirling Convertor Durability Testing: Plans and Interim Results

The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, NASA?s Glenn Research Center (GRC) has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

Meer, Dave↗

Architecture-Based Control of Temperature Gradient-Driven Water Transport in Polymer Electrolyte Fuel Cells

Temperature gradients can move water within the porous media of a polymer electrolyte fuel cell through phase-change-induced (PCI) flow. It is critical to understand PCI flow so that control and distribution of water within a fuel cell can be accomplished. This work investigates the role of architecture, specifically anode land width, on overall cell water content and distribution in the through-plane direction. A specially-designed 4.8 cm 2 fuel cell with precise thermal boundary conditions was imaged with neutrons using two different anode flow field configurations. A new, non-dimensional thermal transport number was developed which quantifies the relative influence of PCI flow on cell water transport. It was found that anode lands larger than the cathode lands cause large thermal gradients that instigate net water flux from the cathode to the anode. An asymmetric configuration with larger anode lands was found to have large changes in water content that were strongly sensitive to cell operating conditions. The thermal transport number developed here enables deduction of the net flux condition based on operating conditions and architecture. This approach enables design of high-performance systems with balanced water management.

25 ENERGY STORAGE↗

Insights into mixing of non-isothermal multi-polymer melts for complex plastics recycling

Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .

Close-clearance impellers↗

Hybrid electric vehicle and method of operating engine of the same

A hybrid electric vehicle (HEV) for multiple operation modes includes: a gasoline diffusion flame (GDF) combustion engine configured to perform gasoline diffusion flame combustion; a motor-generator operatively connected to the GDF combustion engine and configured to selectively drive the HEV with electric power of a battery or generate electric power to charge the battery; and a multi-mode controller including a processor and configured to receive operating conditions of the GDF combustion engine and the motor-generator and define a plurality of mode operating regions based on the received operating conditions. In particular, the plurality of mode operating regions includes: an electric vehicle (EV) only mode operating region, a GDF mode operating region where the GDF combustion engine operates and drives the HEV while the motor-generator stops, and a GDF+EV mode operating region where the motor-generator assists the operation of the GDF combustion engine to drive the HEV.

Bourcier, Mark↗

Universal correlation for falling film evaporation on a horizontal plain tube

Falling film evaporators are widely used in many industrial sectors, such as desalination, refrigeration & air-conditioning, and chemical processes. The heat transfer correlations suitable for wider operating conditions and various refrigerants are useful for designing falling film evaporators. Although many researchers developed the correlation for their own experimental data, there is a limited universal correlation for falling film evaporators. In addition, the dry-out effects were not considered in the available universal correlations. Here, therefore, this study proposes a new correlation for falling film evaporation on a single horizontal plain tube, which includes nucleate boiling, film evaporation, and dry-out effects. The proposed correlation covers a wider range of operating conditions (Heat flux is of 2.5–168kWm -2 , and film Reynolds number is up to 3500), various refrigerants (R134a, R245fa, R1234ze(E), R123, R32, R410A, R290, and R600a), and the large number of experimental data (1101 data in total). The proposed correlation is validated against the available standard correlation with regard to mean absolute deviation (MAD) and R 2 values. The MAD of the new correlation is about 10%, respectively, which is the lowest among other correlations. Similarly, the R 2 showed a value of 0.92, which is the highest compared to the existing correlations. A simplified correlation is also proposed.

42 ENGINEERING↗

Assessing Fuel Cycle Options for Elysium Molten Chloride Salt Fast Reactor from Spent Nuclear Fuel, Plutonium, and Depleted Uranium (Final CRADA Report)

Argonne National Laboratory performed calculations in order to determine the viability of various mode of operation and operating conditions for the reactor designed by Elysium Industry. The reactor description, operating conditions, startup fuel composition, and other relevant information were provided by Elysium to Argonne. The tools currently available at Argonne were used to perform the calculations and provide an assessment for the various cases agreed upon. The results were shared with Elysium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thirty-centimeter-diameter ion milling source

A 30-cm beam diameter ion source has been designed and fabricated for micromachining and sputtering applications. An argon ion current density of 1 mA/cu cm at 500 eV ion energy was selected as a design operating condition. The completed ion source met the design criteria at this operating condition with a uniform and well-collimated beam having an average variation in current density of + or - 5% over the center of 20 cm of the beam. This ion source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. Langmuir probe surveys of the source plasma support the design concepts of a multipole field and a circumferential cathode to enhance plasma uniformity.

Robinson, R. S.↗

A Parameter Identification Method for Helicopter Noise Source Identification and Physics-Based Semi-Empirical Modeling

A new physics-based parameter identification method for rotor harmonic noise sources is developed using an acoustic inverse simulation technique. This new method allows for the identification of individual rotor harmonic noise sources and allows them to be characterized in terms of their individual non-dimensional governing parameters. This new method is applied to both wind tunnel measurements and ground noise measurements of two-bladed rotors. The method is shown to match the parametric trends of main rotor Blade-Vortex Interaction (BVI) noise, allowing accurate estimates of BVI noise to be made for operating conditions based on a small number of measurements taken at different operating conditions.

Greenwood, Eric, II↗

Fundamental Rotorcraft Acoustic Modeling From Experiments (FRAME)

A new methodology is developed for the construction of helicopter source noise models for use in mission planning tools from experimental measurements of helicopter external noise radiation. The models are constructed by employing a parameter identification method to an assumed analytical model of the rotor harmonic noise sources. This new method allows for the identification of individual rotor harmonic noise sources and allows them to be characterized in terms of their individual non-dimensional governing parameters. The method is applied to both wind tunnel measurements and ground noise measurements of two-bladed rotors. The method is shown to match the parametric trends of main rotor harmonic noise, allowing accurate estimates of the dominant rotorcraft noise sources to be made for operating conditions based on a small number of measurements taken at different operating conditions. The ability of this method to estimate changes in noise radiation due to changes in ambient conditions is also demonstrated.

Greenwood, Eric↗

Study to determine operational and performance criteria for STOL aircraft operating in low visibility conditions

The operational and performance criteria for civil CTOL passenger-carrying airplanes landing in low visibilities depend upon the characteristics of the airplane, the nature and use of the ground and airborne guidance and control systems, and the geometry and lighting of the landing field. Based upon these criteria, FAA advisory circulars, airplane and equipment design characteristics, and airline operational and maintenance procedures were formulated. The documents are selected, described, and discussed in relationship to the potential low weather minima operation of STOL aircraft. An attempt is made to identify fundamental differences between CTOL and STOL aircraft characteristics which could impact upon existing CTOL documentation. Further study and/or flight experiments are recommended.

Gorham, J. A.↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 12A - Rotorcraft Flight Envelope Unique Considerations

As noted in Section 12, the term flight envelope is used to refer to the boundaries of aircraft loading and flight conditions within which operation of the aircraft is satisfactory, and beyond which some aspect becomes unacceptable. Each aircraft has its own peculiar set of operating conditions and limitations, and this is particularly true of rotorcraft. In addition to the concerns of the fixed wing aircraft test engineer, the helicopter test engineer has to be concerned with dynamic components such as main and tail rotors and their associated control components, transmissions, noise, vibrations, and environmental factors such as swirling particulates which can cause visual obscuration and/or aircraft erosion when operating in unprepared areas like desert, snow, or over salt water. Operation in the hover/low speed regime is a unique capability and is therefore the forte of the helicopter. This "new" regime has its own envelope concerns. This Section provides a brief overview of some of the considerations when establishing/expanding the flight envelope of a rotorcraft. Types of tests and maneuvers, instrumentation, and special considerations will be discussed. However, the reader must be aware that this Section is far from a complete description of all the factors which must be considered in establishing a rotorcraft flight envelope. Much of the material presented in Section 12 is pertinent to rotorcraft envelope definition.

Michael W Mosher↗

Adaptive Performance Seeking Control Using Fuzzy Model Reference Learning Control and Positive Gradient Control

Performance Seeking Control attempts to find the operating condition that will generate optimal performance and control the plant at that operating condition. In this paper a nonlinear multivariable Adaptive Performance Seeking Control (APSC) methodology will be developed and it will be demonstrated on a nonlinear system. The APSC is comprised of the Positive Gradient Control (PGC) and the Fuzzy Model Reference Learning Control (FMRLC). The PGC computes the positive gradients of the desired performance function with respect to the control inputs in order to drive the plant set points to the operating point that will produce optimal performance. The PGC approach will be derived in this paper. The feedback control of the plant is performed by the FMRLC. For the FMRLC, the conventional fuzzy model reference learning control methodology is utilized, with guidelines generated here for the effective tuning of the FMRLC controller.

Kopasakis, George↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental and Computational Investigation of the Tip Clearance Flow in a Transonic Axial Compressor Rotor

Experimental and computational techniques are used to investigate tip clearance flows in a transonic axial compressor rotor at design and part speed conditions. Laser anemometer data acquired in the endwall region are presented for operating conditions near peak efficiency and near stall at 100% design speed and at near peak efficiency at 60% design speed. The role of the passage shock/leakage vortex interaction in generating endwall blockage is discussed. As a result of the shock/vortex interaction at design speed, the radial influence of the tip clearance flow extends to 20 times the physical tip clearance height. At part speed, in the absence of the shock, the radial extent is only 5 times the tip clearance height. Both measurements and analysis indicate that under part-speed operating conditions a second vortex, which does not originate from the tip leakage flow, forms in the endwall region within the blade passage and exits the passage near midpitch. Mixing of the leakage vortex with primary flow downstream of the rotor at both design and part speed conditions is also discussed.

Suder, Kenneth L.↗